DC Gate Operators Overview Brochure Manual
Page 2
... and return gate to maximize solar performance. • Common Control Board User Interface simplifies installation and troubleshooting. • Diagnostic 2 Digit LED Display speeds installation and troubleshooting by providing more cycles or days of standby time than ever before. • Security+ 2.0™...can tailor the performance for 120V or 230V single phase (LA500DC, CSL24VDC, CSW24VDC). © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTCOMP 6/14 Expansion board is extremely power efficient at open or close limits. • Quick ...
... and return gate to maximize solar performance. • Common Control Board User Interface simplifies installation and troubleshooting. • Diagnostic 2 Digit LED Display speeds installation and troubleshooting by providing more cycles or days of standby time than ever before. • Security+ 2.0™...can tailor the performance for 120V or 230V single phase (LA500DC, CSL24VDC, CSW24VDC). © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTCOMP 6/14 Expansion board is extremely power efficient at open or close limits. • Quick ...
RSW12U Installation Manual
Page 3
... ONLY 18 INSTALL THE COVER 20 ADJUSTMENT 21 LIMIT AND FORCE ADJUSTMENT 21 PROGRAMMING 23 REMOTE CONTROLS (NOT PROVIDED 23 LIFTMASTER INTERNET GATEWAY (NOT PROVIDED 24 ERASE ALL CODES 24 ERASE LIMITS 24 TO REMOVE AND ERASE MONITORED ENTRAPMENT PROTECTION DEVICES...LOCKS ...28 MISCELLANEOUS WIRING 28 MAINTENANCE 29 IMPORTANT SAFETY INFORMATION 29 MAINTENANCE CHART 29 BATTERIES 29 TROUBLESHOOTING 30 DIAGNOSTIC CODES 30 CONTROL BOARD LEDS 33 TROUBLESHOOTING CHART 34 APPENDIX 36 DUAL GATE SETTINGS 36 INSTALLATION TYPES 37 DETERMINE LOCATION FOR CONCRETE PAD ...
... ONLY 18 INSTALL THE COVER 20 ADJUSTMENT 21 LIMIT AND FORCE ADJUSTMENT 21 PROGRAMMING 23 REMOTE CONTROLS (NOT PROVIDED 23 LIFTMASTER INTERNET GATEWAY (NOT PROVIDED 24 ERASE ALL CODES 24 ERASE LIMITS 24 TO REMOVE AND ERASE MONITORED ENTRAPMENT PROTECTION DEVICES...LOCKS ...28 MISCELLANEOUS WIRING 28 MAINTENANCE 29 IMPORTANT SAFETY INFORMATION 29 MAINTENANCE CHART 29 BATTERIES 29 TROUBLESHOOTING 30 DIAGNOSTIC CODES 30 CONTROL BOARD LEDS 33 TROUBLESHOOTING CHART 34 APPENDIX 36 DUAL GATE SETTINGS 36 INSTALLATION TYPES 37 DETERMINE LOCATION FOR CONCRETE PAD ...
RSW12U Installation Manual
Page 27
... power is restored or batteries voltage increases. • Option select switch set to automatically close the gate. The TTC is in the Troubleshooting section. 11 DIAGNOSTICS Display: The diagnostics code display will close the gate after the operator type, example "1.2". 12 BACKDRIVE Switch: Not...8226; Constant pressure on the control board prior to 180 seconds, 0 seconds is reset by a "12" which indicates the operator type as RSW12U. See Force Adjustment section. 9 TEST BUTTONS: The TEST BUTTONS will remain open or close photoelectric sensors (IR's). 8 REVERSAL FORCE dial: The...
... power is restored or batteries voltage increases. • Option select switch set to automatically close the gate. The TTC is in the Troubleshooting section. 11 DIAGNOSTICS Display: The diagnostics code display will close the gate after the operator type, example "1.2". 12 BACKDRIVE Switch: Not...8226; Constant pressure on the control board prior to 180 seconds, 0 seconds is reset by a "12" which indicates the operator type as RSW12U. See Force Adjustment section. 9 TEST BUTTONS: The TEST BUTTONS will remain open or close photoelectric sensors (IR's). 8 REVERSAL FORCE dial: The...
RSW12U Installation Manual
Page 32
TROUBLESHOOTING To protect against fire: • Replace ONLY with "01" and going up to code "20". DIAGNOSTIC CODES NOTE: When cycling or disconnecting power (ac/dc) ...
TROUBLESHOOTING To protect against fire: • Replace ONLY with "01" and going up to code "20". DIAGNOSTIC CODES NOTE: When cycling or disconnecting power (ac/dc) ...
RSW12U Installation Manual
Page 33
... system. If not, disconnect all power, wait 15 seconds, then reconnect power (reboot). Make sure you do NOT have a 12V battery on a 12V system. LiftMaster Plug-in . If a code is NOT a single 12V battery on the battery. If issue continues, replace main control board. Exit Loop Error Shadow Loop Error... Second Operator Communication Check the second operator for power. Pass-point not detected (Arm 2) Brownout occurred AC/DC board supply dipped below allowable level. TROUBLESHOOTING DIAGNOSTIC CODES continued... Pass-point not detected (Arm 1) Check yellow pass-point wiring.
... system. If not, disconnect all power, wait 15 seconds, then reconnect power (reboot). Make sure you do NOT have a 12V battery on a 12V system. LiftMaster Plug-in . If a code is NOT a single 12V battery on the battery. If issue continues, replace main control board. Exit Loop Error Shadow Loop Error... Second Operator Communication Check the second operator for power. Pass-point not detected (Arm 2) Brownout occurred AC/DC board supply dipped below allowable level. TROUBLESHOOTING DIAGNOSTIC CODES continued... Pass-point not detected (Arm 1) Check yellow pass-point wiring.
RSW12U Installation Manual
Page 34
...YES YES YES YES 32 OPEN EYE/EDGE held more than 3 minutes CLOSE EYE/INTERRUPT held more than 3 minutes obstruction. LiftMaster System Installed System Informational External Entrapment Protection Inherent Entrapment Protection Code 60 61 62 63 64 65 66 67 68 69 70...of monitoring Check wireless edge inputs. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board; TROUBLESHOOTING DIAGNOSTIC CODES continued... OPEN EYE/EDGE held more than 3 minutes Wireless edge triggered more than 3 minutes Check wired input for alignment...
...YES YES YES YES 32 OPEN EYE/EDGE held more than 3 minutes CLOSE EYE/INTERRUPT held more than 3 minutes obstruction. LiftMaster System Installed System Informational External Entrapment Protection Inherent Entrapment Protection Code 60 61 62 63 64 65 66 67 68 69 70...of monitoring Check wireless edge inputs. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board; TROUBLESHOOTING DIAGNOSTIC CODES continued... OPEN EYE/EDGE held more than 3 minutes Wireless edge triggered more than 3 minutes Check wired input for alignment...
RSW12U Installation Manual
Page 35
TROUBLESHOOTING CONTROL BOARD LEDS STATUS LEDS INPUT OFF POWER ON OFF state AC charger or Solar power available BATT OFF CHARGING ON Not charging Three stage ...
TROUBLESHOOTING CONTROL BOARD LEDS STATUS LEDS INPUT OFF POWER ON OFF state AC charger or Solar power available BATT OFF CHARGING ON Not charging Three stage ...
RSW12U Installation Manual
Page 36
... wireless controls or devices. Charge batteries by AC or solar power or replace batteries. 34 Charge batteries by AC or solar power or replace batteries. TROUBLESHOOTING TROUBLESHOOTING CHART SYMPTOM POSSIBLE CAUSES SOLUTIONS Operator does not a) No power to control board a) Check AC and battery power run and error code b) Open fuse b) Check...
... wireless controls or devices. Charge batteries by AC or solar power or replace batteries. 34 Charge batteries by AC or solar power or replace batteries. TROUBLESHOOTING TROUBLESHOOTING CHART SYMPTOM POSSIBLE CAUSES SOLUTIONS Operator does not a) No power to control board a) Check AC and battery power run and error code b) Open fuse b) Check...
RSW12U Installation Manual
Page 37
... obstruction test and perform the proper force adjustment that opens first) a) Pre-warning is needed gate's path does not cause gate to Wiring Diagrams). 35 TROUBLESHOOTING TROUBLESHOOTING CHART continued... b) Replace defective photoelectric sensor. Retest that activating edge sensor causes moving gate to shut off alarm and reset the operator. a) Incorrect photoelectric sensor...
... obstruction test and perform the proper force adjustment that opens first) a) Pre-warning is needed gate's path does not cause gate to Wiring Diagrams). 35 TROUBLESHOOTING TROUBLESHOOTING CHART continued... b) Replace defective photoelectric sensor. Retest that activating edge sensor causes moving gate to shut off alarm and reset the operator. a) Incorrect photoelectric sensor...
RSW12U Installation Manual
Page 38
...and COM wires does not activate Solenoid, then replace Solenoid lock or Solenoid wiring (refer to the primary operator. TROUBLESHOOTING TROUBLESHOOTING CHART continued... MAIN CONTROL BOARD FEATURE Timer-toClose Bi-Part Delay Switch PRIMARY OPERATOR Set the TTC dial to desired ... last) Tandem Mode: OFF Synchronized Close: ON ACCESSORY PRIMARY OPERATOR Remote Controls Program remote controls 1 to 50 to Wiring Diagrams). LiftMaster Program to primary Monitor operator. Check that Solenoid has power (do not power solenoid from obstructions (trees, buildings, etc.) a)...
...and COM wires does not activate Solenoid, then replace Solenoid lock or Solenoid wiring (refer to the primary operator. TROUBLESHOOTING TROUBLESHOOTING CHART continued... MAIN CONTROL BOARD FEATURE Timer-toClose Bi-Part Delay Switch PRIMARY OPERATOR Set the TTC dial to desired ... last) Tandem Mode: OFF Synchronized Close: ON ACCESSORY PRIMARY OPERATOR Remote Controls Program remote controls 1 to 50 to Wiring Diagrams). LiftMaster Program to primary Monitor operator. Check that Solenoid has power (do not power solenoid from obstructions (trees, buildings, etc.) a)...
RSW12U Sell Sheet Manual
Page 1
...-TAILGATE Prevents unauthorized access. 12VDC Residential/Light Commercial Swing Gate Operator RSW12U FEATURES LED DIAGNOSTIC DISPLAY Simplifies installation and troubleshooting. SYNCHRONIZED CLOSE Simultaneously closes gates. COVER High-density, UV-resistant polycarbonate 2-piece cover for best performance on battery backup. ©2015 LiftMaster. RECOMMENDED CAPACITIES Rated for applications requiring a large number of remote controls...
...-TAILGATE Prevents unauthorized access. 12VDC Residential/Light Commercial Swing Gate Operator RSW12U FEATURES LED DIAGNOSTIC DISPLAY Simplifies installation and troubleshooting. SYNCHRONIZED CLOSE Simultaneously closes gates. COVER High-density, UV-resistant polycarbonate 2-piece cover for best performance on battery backup. ©2015 LiftMaster. RECOMMENDED CAPACITIES Rated for applications requiring a large number of remote controls...