LiftMaster MASTDCBB3 Support and Manuals

Get Help and Manuals for this LiftMaster item

View All Support Options Below
Free LiftMaster MASTDCBB3 manuals!
Problems with LiftMaster MASTDCBB3?

Ask a Question

Popular LiftMaster MASTDCBB3 Manual Pages

MEGA ARM / MEGA ARM TOWER Manual - Page 2

...OPERATION AND MAINTENANCE Important Safety Instructions General Service Shear Pin Replacement Battery ADDITIONAL FEATURES Suggested Loop Sensor Locations Trap Instructions Sequence Access Management System (SAMS) with "Memory" Control Board Layout TROUBLESHOOTING Battery Checkout Gate Not Operating Troubleshooting Chart REPAIR PARTS Part Numbers and Descriptions Parts Shipped Mega Arm Tower Unique...
MEGA ARM / MEGA ARM TOWER Manual - Page 3

... or building such as a factory or loading dock area or other building servicing the general public. CLASS IV - COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR II...UL325 ENTRAPMENT PROTECTION REQUIREMENTS GATE OPERATOR ENTRAPMENT PROTECTION UL325 Installation Class Class I - SAFETY » UL325 MODEL CLASSIFICATIONS UL325 MODEL CLASSIFICATIONS CLASS I & II Slide Gate Operator Primary ...
MEGA ARM / MEGA ARM TOWER Manual - Page 5

...; On 120 Vac installations, unswitched duplex outlet gives convenient supply for the 12-15 foot x 3 inch tubular aluminum barrier arm • Heater option MUST be needed. • Wrench or Socket Set • Phillips Head Screwdriver • C Clamps • Level • Small Screwdriver • T25 Torx Head Screwdriver OPERATOR SPECIFICATIONS This model is 30°...
MEGA ARM / MEGA ARM TOWER Manual - Page 12

...C15 DJ121Ø 1 AUX LIMITS M/S J3 R14 S3 MANUAL R18 Q2 OPEN 1 2 3 4 5 6 7 ...for changing the code setting or replacing the battery. C4...INSTALL THE RECEIVER WIRING THE RECEIVER Contacts 1 and 2 on the J4 terminal strip at HIGH. The receiver is pressed. THERE ARE NO OTHER USER SERVICEABLE PARTS. The jumper must be set...code remotes or passwords in HIGH security mode. SET...
MEGA ARM / MEGA ARM TOWER Manual - Page 13

...OPEN LIMIT (OLS) is 1-1/2 seconds. When S1-8 DIP switch is to the left -hand operation is set to 2-3/8 seconds by DIP switch S1-7. If the Close Loop detects tailgating, the K1 Relay will activate ...(blue wire) and J4-8 (orange wire) (see below). Turn the Limit Cam so the Limit Cam is manually forced UP (OPEN), the barrier arm will run time is reached. When S1-8 DIP switch is in the ...
MEGA ARM / MEGA ARM TOWER Manual - Page 14

...barrier arm. To de-activate this feature turn S2-7 DIP switch to S2-5 DIP switches will set amount of time elapses and the count memory is 32 seconds. S1 S2 1 2345678 1 2345678 ... time the barrier arm remains OPEN. Turning multiple switches ON will resume normal operation after the set the period of time the gate remains opened until the batteries are 4 seconds to allow a...
MEGA ARM / MEGA ARM TOWER Manual - Page 15

...REVERSE DEVICE (IRD) + INSTALL THE BARRIER ARM To .... Keep the remote control away from the gate. Have a qualified service person make repairs to test if the arm is not closing the arm will reverse ...(using the time delay set at S-2 switches 1-5) and then close. Read the owner's manual. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. SAVE THESE INSTRUCTIONS. 15 After any adjustment ...
MEGA ARM / MEGA ARM TOWER Manual - Page 16

...Manual Open switch to CLOSE to the up position. 2. Replace in accordance with a number 6 taper only.) NEVER USE A BOLT AS A TEMPORARY FIX, THIS WILL DAMAGE THE SHAFT AND COLLAR. 1. EVERY 6 MONTHS z EVERY 12 MONTHS ◆ ◆ ◆ EVERY 24 MONTHS z SHEAR PIN REPLACEMENT If gate arm is recommended that support... into operation. BATTERY REPLACEMENT Service Kits are better than...
MEGA ARM / MEGA ARM TOWER Manual - Page 18

...BETWEEN THE OPERATORS 1. See Mega Arm Options Parts List Close Loop Trap Close Loop Trap Close... 0 is open output (NO) of the second operator (J5 - Set switch bank S1 to the operator. 3. Connect the Normally open , ...replacing the neutral (Black) wire to the common of the K1 relay on the trap operator. ADDITIONAL FEATURES » TRAP INSTRUCTIONS TRAP INSTRUCTIONS INSTALL...
MEGA ARM / MEGA ARM TOWER Manual - Page 19

... will keep the other operators common and open signal was sent to store input counts via a car crossing the MEGA ARM's close loop. OPERATION A one set of 30 VOLTS at the other operator reaches its K1 relay sending an open the COMMON and NORMALLY CLOSED contact on the MEGA ARM. Run...
MEGA ARM / MEGA ARM TOWER Manual - Page 20

...Drivers On Close Limit Sensor Obstruction Sense (IRD and MRT) Relay Indicator Relay (Optional) 1 1 J2 AUX LIMITS M/S J3 R14 D8 D1Ø R18 S1 S2 1 2345678 1 2345678 R1 R12 R17 R16 MANUAL... F3 WARNING FOR R62 CONTINUOUS PROTECTION AGAINST FIRE DX1 REPLACE ONLY WITH THE SAME TYPE AND RATING OF FUSE D26...closed during service of operator. Reader, Push Button Aux Open / Reset (Pulse...
MEGA ARM / MEGA ARM TOWER Manual - Page 21

TROUBLESHOOTING » BATTERY CHECKOUT + GATE NOT OPERATING WARNING - DISCONNECT BATTERIES AND AC POWER BEFORE SERVICING ANY MECHANICAL OR MOVING COMPONENTS. NOTE: Batteries should be checked ... mode switch 8 on S2 is 27.5 Vdc with batteries not connected (set with R63, shown on the Control Board Layout page). Check fuse F4 Replace if blown. No No Yes Is the AC PWR LED on now? Yes...
MEGA ARM / MEGA ARM TOWER Manual - Page 22

... 10 MA010 Gate Arm Bracket 11 MA011 Magnet 12 MA012 Cam Arm 13 MA013 Shear Pin PARTS SHIPPED ITEM MEGA ARM Operator Controller Operator Cover Installation and Service Manual Arm Bolts with Washers Nylon Nuts 7AH Batteries ITEM PART NUMBER 14 MA014 15 MA015 16 MA016 17 MA017 19 MA019 * MA020 * MA021 * MA022 * MA023 * 73A3...
MEGA ARM / MEGA ARM TOWER Manual - Page 23

... 12' x 4" diameter, yellow (requires MA031). Model MA028 REPLACEMENT PAD 14' x 4", yellow. Model MA116 ALUMINUM GATE ARM 15' x 3" with yellow/black stripes. Model MA033 PVC ARM: 9' (Only for all 15' arms. Model MA117 ALUMINUM GATE ARM White, 15' x 3" (requires MA117). Model SP8 REPLACEMENT ARM TUBE Model SP8 TUBE REPLACEMENT PAD Yellow. Model SP8 PAD 23 Model UN201 SLIP CLUTCH OPTION For...
MEGA ARM / MEGA ARM TOWER Manual - Page 24

..., operation without notice. 01-60162G HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION SIMPLY DIAL OUR TOLL FREE NUMBER: 1-800-528-2806 www.liftmaster.com WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART NAME • MODEL NUMBER ADDRESS ORDERS TO: THE CHAMBERLAIN GROUP, INC. Freight...

LiftMaster MASTDCBB3 Reviews

Do you have an experience with the LiftMaster MASTDCBB3 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for LiftMaster yet.

Ask a New Question
Use the box below to post a new question about LiftMaster MASTDCBB3.
Manuals / Documents
Download any of our LiftMaster MASTDCBB3 manuals for free!

We have the following 1 documents available for the LiftMaster MASTDCBB3:
  • MEGA ARM / MEGA ARM TOWER Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LiftMaster Manuals

Find free LiftMaster MASTDCBB3 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LiftMaster Reviews

View thousands of LiftMaster MASTDCBB3 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LiftMaster customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LiftMaster customer service rankings, employee comments and much more from our sister site.