Refer to the solar cycle chart for more details. Manual
Page 1
... be cleaned regularly to the operator control board. LA412 Solar Gate Access System Daily Cycle Chart The LA412 Solar Gate Access System utilizes the innovative EverCharge® Power Management System to the gate operator via batteries. Power is not supported in climates where temperatures ...°F. Optional external power reserve model BIGBTYKIT (80Ah battery not included) or extra large control box model LA412CONTXLM (with 33Ah battery) recommended for operating a gate while minimizing power consumption at all other times. LA412 not supported/available in an open area clear of...
... be cleaned regularly to the operator control board. LA412 Solar Gate Access System Daily Cycle Chart The LA412 Solar Gate Access System utilizes the innovative EverCharge® Power Management System to the gate operator via batteries. Power is not supported in climates where temperatures ...°F. Optional external power reserve model BIGBTYKIT (80Ah battery not included) or extra large control box model LA412CONTXLM (with 33Ah battery) recommended for operating a gate while minimizing power consumption at all other times. LA412 not supported/available in an open area clear of...
LA412 Manual
Page 5
... the operator without consulting the wiring diagram. SOLAR PANEL INSTALLATION To avoid SERIOUS INJURY or DEATH: • Disconnect ALL electric and battery power BEFORE performing ANY service or maintenance. • DO NOT connect solar panel(s) when power supply is adjusted, the other underground... time the unit may explode. To reduce the risk of battery in fire. ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. • DO NOT use ONLY LiftMaster part 29-NP712 for disposal instructions. SAFETY » IMPORTANT SAFETY...
... the operator without consulting the wiring diagram. SOLAR PANEL INSTALLATION To avoid SERIOUS INJURY or DEATH: • Disconnect ALL electric and battery power BEFORE performing ANY service or maintenance. • DO NOT connect solar panel(s) when power supply is adjusted, the other underground... time the unit may explode. To reduce the risk of battery in fire. ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. • DO NOT use ONLY LiftMaster part 29-NP712 for disposal instructions. SAFETY » IMPORTANT SAFETY...
LA412 Manual
Page 6
... travel . • ALWAYS keep remote controls out of reach of same type and rating. 5 For continued protection against fire and electrocution: • DISCONNECT power and battery BEFORE installing or servicing operator. Failure to adjust and retest the gate operator properly can be seen clearly, is properly adjusted, and there are no...
... travel . • ALWAYS keep remote controls out of reach of same type and rating. 5 For continued protection against fire and electrocution: • DISCONNECT power and battery BEFORE installing or servicing operator. Failure to adjust and retest the gate operator properly can be seen clearly, is properly adjusted, and there are no...
LA412 Manual
Page 7
....4" (95 cm) 53.5" (136 cm) CARTON INVENTORY This operator comes with 2 Batteries Moving Gate Can Cause Injury or Death KEEP CLEAR! If your application requires the gate to -Open Bracket Model LA412 (1) Model LA412-S (2) Gate Bracket Model LA412 (1) Model LA412-S (2) Post Bracket Model LA412 (1) Model LA412-S (2) 12V 10W Solar Panel Model SOLPNL10W12V (1) Cable Ties (4) Standard Control Box...
....4" (95 cm) 53.5" (136 cm) CARTON INVENTORY This operator comes with 2 Batteries Moving Gate Can Cause Injury or Death KEEP CLEAR! If your application requires the gate to -Open Bracket Model LA412 (1) Model LA412-S (2) Gate Bracket Model LA412 (1) Model LA412-S (2) Post Bracket Model LA412 (1) Model LA412-S (2) 12V 10W Solar Panel Model SOLPNL10W12V (1) Cable Ties (4) Standard Control Box...
LA412 Manual
Page 9
...!umpiedrrusirGGsaofeyatrratoneteruaowos.vearepmereashnriiyCeaDcntlpaegmeea.rtsonaavhttoeeenClhagetyaanttauernasyonrece Hinge Post Bracket Operator Operator Cable Antenna Solar Panel (Facing South) Control Box with Batteries Solar Panel (Facing South) Hinge Post Bracket Gate Bracket PVC Conduit (not provided) to protect the ...string trimmers. INSTALLATION » OVERVIEW OF TYPICAL INSTALLATION LEFT-HAND GATE Warning Sign Antenna Control Box with Batteries Photoelectric Sensors 1gw2a1ir2ueWgGiareeuge PVC Conduit (not provided) to protect the power cable for solar and low voltage ...
...!umpiedrrusirGGsaofeyatrratoneteruaowos.vearepmereashnriiyCeaDcntlpaegmeea.rtsonaavhttoeeenClhagetyaanttauernasyonrece Hinge Post Bracket Operator Operator Cable Antenna Solar Panel (Facing South) Control Box with Batteries Solar Panel (Facing South) Hinge Post Bracket Gate Bracket PVC Conduit (not provided) to protect the ...string trimmers. INSTALLATION » OVERVIEW OF TYPICAL INSTALLATION LEFT-HAND GATE Warning Sign Antenna Control Box with Batteries Photoelectric Sensors 1gw2a1ir2ueWgGiareeuge PVC Conduit (not provided) to protect the power cable for solar and low voltage ...
LA412 Manual
Page 10
... trimmers. INSTALLATION » OVERVIEW OF TYPICAL INSTALLATION DUAL GATE Solar Panel (Facing South) Antenna Warning Sign Hinge Post Bracket Gate Bracket Gate 1 Control Box with Batteries Operator Cable Gate 2 Junction Box Extension Cable Photoelectric Sensors PVC Conduit (not provided) to reduce the risk of entrapment or obstruction exists at either the...
... trimmers. INSTALLATION » OVERVIEW OF TYPICAL INSTALLATION DUAL GATE Solar Panel (Facing South) Antenna Warning Sign Hinge Post Bracket Gate Bracket Gate 1 Control Box with Batteries Operator Cable Gate 2 Junction Box Extension Cable Photoelectric Sensors PVC Conduit (not provided) to reduce the risk of entrapment or obstruction exists at either the...
LA412 Manual
Page 18
... control box. 2 Disconnect the reset button, alarm, and coaxial connector. 3 Loosen screws to remove the control board and mounting bracket. 4 Remove the control board. 5 Remove batteries and set aside. 6 Select mounting holes and knock out using a screwdriver and hammer. 7 Secure the control box to mounting surface using the appropriate hardware (not...
... control box. 2 Disconnect the reset button, alarm, and coaxial connector. 3 Loosen screws to remove the control board and mounting bracket. 4 Remove the control board. 5 Remove batteries and set aside. 6 Select mounting holes and knock out using a screwdriver and hammer. 7 Secure the control box to mounting surface using the appropriate hardware (not...
LA412 Manual
Page 19
INSTALLATION » STANDARD CONTROL BOX INSTALL THE CONTROL BOARD NOTE: Make sure the battery leads are on the left side of the control box and not pinched. 1 Attach the antenna. 2 Reinstall the batteries, control board, alarm and reset button. 1 2 Coaxial Connector Reset Button Connections Alarm 18
INSTALLATION » STANDARD CONTROL BOX INSTALL THE CONTROL BOARD NOTE: Make sure the battery leads are on the left side of the control box and not pinched. 1 Attach the antenna. 2 Reinstall the batteries, control board, alarm and reset button. 1 2 Coaxial Connector Reset Button Connections Alarm 18
LA412 Manual
Page 26
...and weather conditions may vary from solar chart for using a single 10W solar panel in conjunction with a 10 foot (3 m) cable. The LA412 Solar Gate Operator is not supported in northern climates where temperatures reach below 32° F. This is based upon the average solar radiation ...and the temperature effects on batteries in the given regions. Solar panels should be cleaned on gate construction and installation. They are approximations and do not account for the...
...and weather conditions may vary from solar chart for using a single 10W solar panel in conjunction with a 10 foot (3 m) cable. The LA412 Solar Gate Operator is not supported in northern climates where temperatures reach below 32° F. This is based upon the average solar radiation ...and the temperature effects on batteries in the given regions. Solar panels should be cleaned on gate construction and installation. They are approximations and do not account for the...
LA412 Manual
Page 27
...° (solar panel(s) sits more vertical). 26 TIP: Wire runs should be kept as short as possible. If the panel(s) is not casting a shadow, the battery is critical to west. Solar Panel (Facing South) Control Box TIP: The area around the solar panel(s) should be clear of shadows or obstructions to...
...° (solar panel(s) sits more vertical). 26 TIP: Wire runs should be kept as short as possible. If the panel(s) is not casting a shadow, the battery is critical to west. Solar Panel (Facing South) Control Box TIP: The area around the solar panel(s) should be clear of shadows or obstructions to...
LA412 Manual
Page 29
... if the solar panel is correctly installed and the sun is no other way to connector on the left-hand side of the control box. Batteries do not perform well in transformer or a separate solar panel, but not both. 1 Solar Panel Control Board 2 3 AC PWR/ SOLAR J4 Red 5 Black 4 ...watertight connector and pull the cable through until it could be replaced every 3 years. Leave the AC PWR/SOLAR earth ground connection open. NOTES: Batteries will blink). There is shining (the diagnostic LED will degrade over time depending on the cable. 5 Attach the solar panel wires to AC ...
... if the solar panel is correctly installed and the sun is no other way to connector on the left-hand side of the control box. Batteries do not perform well in transformer or a separate solar panel, but not both. 1 Solar Panel Control Board 2 3 AC PWR/ SOLAR J4 Red 5 Black 4 ...watertight connector and pull the cable through until it could be replaced every 3 years. Leave the AC PWR/SOLAR earth ground connection open. NOTES: Batteries will blink). There is shining (the diagnostic LED will degrade over time depending on the cable. 5 Attach the solar panel wires to AC ...
LA412 Manual
Page 34
... and or Industry Canada (IC) rules, adjustment or modifications of products. All previous codes are prohibited, except for changing the code setting or replacing the battery. NOTICE: To comply with an obstruction. Make sure the rubber seal around the cover is intact and close the gate. 2 Test the limits by making...
... and or Industry Canada (IC) rules, adjustment or modifications of products. All previous codes are prohibited, except for changing the code setting or replacing the battery. NOTICE: To comply with an obstruction. Make sure the rubber seal around the cover is intact and close the gate. 2 Test the limits by making...
LA412 Manual
Page 35
... extended period of the remote control button will close the gate. HOLD OPEN) When the Timer-to normal operation. RESET RESET Reset Button SLEEP MODE (BATTERY CONSERVATION) The operator enters sleep mode 10 seconds after the last command is given. Reset the control board by remote control or SBC on . The...
... extended period of the remote control button will close the gate. HOLD OPEN) When the Timer-to normal operation. RESET RESET Reset Button SLEEP MODE (BATTERY CONSERVATION) The operator enters sleep mode 10 seconds after the last command is given. Reset the control board by remote control or SBC on . The...
LA412 Manual
Page 36
... do some "house cleaning" of the operator and the area around the operator. DESCRIPTION External Entrapment Protection System Manual Release Gate Accessories Electrical Mounting Hardware Batteries Operator Warning Signs TASK Check and test for proper operation Check and test for proper operation Inspect for wear or damage Check all for proper...
... do some "house cleaning" of the operator and the area around the operator. DESCRIPTION External Entrapment Protection System Manual Release Gate Accessories Electrical Mounting Hardware Batteries Operator Warning Signs TASK Check and test for proper operation Check and test for proper operation Inspect for wear or damage Check all for proper...
LA412 Manual
Page 37
... with fuse of same type and rating. 1. Loop Inputs 8. Alarm Output 14. To protect against fire and electrocution: • DISCONNECT power and battery BEFORE installing or servicing operato.r For continued protection against fire: • Replace ONLY with fuse of same type and rating. 23 1 Fault Alarm Automatic... 7 R9 C64 MOV2 R4 C2 J24 J23 3ØA 32V 3ØA 32V J21 D16 15 U2 R22 JU2 DB1 OPTIONAL GROUND ROD 14 NOTE: Batteries MUST 8 be connected to operate. Learn Xmitter 18. Secondary Gate Jog 21. Primary Gate Jog 19. Fuses (20 Amp) 36 Open Photo 5. ...
... with fuse of same type and rating. 1. Loop Inputs 8. Alarm Output 14. To protect against fire and electrocution: • DISCONNECT power and battery BEFORE installing or servicing operato.r For continued protection against fire: • Replace ONLY with fuse of same type and rating. 23 1 Fault Alarm Automatic... 7 R9 C64 MOV2 R4 C2 J24 J23 3ØA 32V 3ØA 32V J21 D16 15 U2 R22 JU2 DB1 OPTIONAL GROUND ROD 14 NOTE: Batteries MUST 8 be connected to operate. Learn Xmitter 18. Secondary Gate Jog 21. Primary Gate Jog 19. Fuses (20 Amp) 36 Open Photo 5. ...
LA412 Manual
Page 38
...Operator is connected between the COM and STOP input on the control board. Stop is an NC (normally closed) input. 3 FLASHES LOW BATTERY VOLTAGE Battery voltage is below . Check the green and white wires on the motor arm to move the arm. Press the LEARN LIMITS button and...then pause signifying it has found a potential issue. TROUBLESHOOTING » DIAGNOSTIC CHART Your gate operator is programmed with same type and rating. • Batteries are no longer capable of holding a charge due to Gate 1 arm. The diagnostic LED will reverse if an obstruction is encountered. 9-11 FLASHES...
...Operator is connected between the COM and STOP input on the control board. Stop is an NC (normally closed) input. 3 FLASHES LOW BATTERY VOLTAGE Battery voltage is below . Check the green and white wires on the motor arm to move the arm. Press the LEARN LIMITS button and...then pause signifying it has found a potential issue. TROUBLESHOOTING » DIAGNOSTIC CHART Your gate operator is programmed with same type and rating. • Batteries are no longer capable of holding a charge due to Gate 1 arm. The diagnostic LED will reverse if an obstruction is encountered. 9-11 FLASHES...
LA412 Manual
Page 39
...(SBC) COMMAND. NOTE: The RESET button may need to be connected for the operator to be above 11.5 V. Check battery connections and battery voltage to operate. With the motor housing still disconnected, enter the Learn Limits mode and verify that the Safety LEDs (OPEN... the arm moves freely. Check wiring for the operator to operate. TROUBLESHOOTING » TROUBLESHOOTING CHART OPERATOR DOES NOT RUN. Check battery connections and battery voltage to verify operator will respond. • Bad control board. If either is interfering with both gates swing easily. Lubricate ...
...(SBC) COMMAND. NOTE: The RESET button may need to be connected for the operator to be above 11.5 V. Check battery connections and battery voltage to operate. With the motor housing still disconnected, enter the Learn Limits mode and verify that the Safety LEDs (OPEN... the arm moves freely. Check wiring for the operator to operate. TROUBLESHOOTING » TROUBLESHOOTING CHART OPERATOR DOES NOT RUN. Check battery connections and battery voltage to verify operator will respond. • Bad control board. If either is interfering with both gates swing easily. Lubricate ...
LA412 Manual
Page 40
...clear of any obstructions. • The Interrupt loop or Shadow loop is flashing. Replace control board. • Obstruction sensed. Check battery connections and battery voltage to desired delay. • Gate opened by a force obstruction reversal. Check the open /close photoelectric sensors, shadow loop, or...-to the control board. • Remote control not learned. ALARM IS BEEPING 3 TIMES ON A COMMAND • Low battery. Replace battery if required. Disconnect the arms and verify that the Safety loop and Shadow loop are properly connected to -Close is continuously ...
...clear of any obstructions. • The Interrupt loop or Shadow loop is flashing. Replace control board. • Obstruction sensed. Check battery connections and battery voltage to desired delay. • Gate opened by a force obstruction reversal. Check the open /close photoelectric sensors, shadow loop, or...-to the control board. • Remote control not learned. ALARM IS BEEPING 3 TIMES ON A COMMAND • Low battery. Replace battery if required. Disconnect the arms and verify that the Safety loop and Shadow loop are properly connected to -Close is continuously ...
LA412 Manual
Page 41
... hardware 4 40 ITEM PART # DESCRIPTION QTY 1 K1A6426-1 Control Board with 3 Mounting Bracket 1 2 K23-19380 Reset Switch 1 7 3 K74-34392 Antenna 1 4 29-NP712 Battery 1 5 K76-19446 Alarm 1 4 5 6 SOLPNL10W12V Solar Panel 2 Not Shown LA412-CONT Complete Control Box K1A6636 Receiver Module - 315 MHz K1A6636-1 Receiver Module - 390 MHz (optional) 1 K76-35600 Reset Switch (XLM Control...
... hardware 4 40 ITEM PART # DESCRIPTION QTY 1 K1A6426-1 Control Board with 3 Mounting Bracket 1 2 K23-19380 Reset Switch 1 7 3 K74-34392 Antenna 1 4 29-NP712 Battery 1 5 K76-19446 Alarm 1 4 5 6 SOLPNL10W12V Solar Panel 2 Not Shown LA412-CONT Complete Control Box K1A6636 Receiver Module - 315 MHz K1A6636-1 Receiver Module - 390 MHz (optional) 1 K76-35600 Reset Switch (XLM Control...
LA412 Manual
Page 42
...INFORMATION: PART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP, INC. Country Club Road Tucson, AZ 85706 WARRANTY POLICY LIFTMASTER TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. You will void this product. Some states do not allow limitations on your compliance...NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, OR REPLACEMENT OF BATTERIES. This limited warranty gives you specific legal rights, and you may not apply to you and returned pre-paid and insured, ...
...INFORMATION: PART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP, INC. Country Club Road Tucson, AZ 85706 WARRANTY POLICY LIFTMASTER TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. You will void this product. Some states do not allow limitations on your compliance...NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, OR REPLACEMENT OF BATTERIES. This limited warranty gives you specific legal rights, and you may not apply to you and returned pre-paid and insured, ...