... ever to install and use. Built to 9 uses KPW250 The best features of Nortek Security & Control LLC. SLEEK WIRELESS DESIGN. RELIABLE PERFORMANCE. Ideal for larger commercial applications. • Programs to all LiftMaster Gate and Commercial Door Operators • Enables flexible setup for 1 to deliver unbeatable performance in tough environments, LiftMaster® Wireless Keypads enable a more modern, streamlined access solution that can be set for multiple users with 250 permanent PINs and...
... ever to install and use. Built to 9 uses KPW250 The best features of Nortek Security & Control LLC. SLEEK WIRELESS DESIGN. RELIABLE PERFORMANCE. Ideal for larger commercial applications. • Programs to all LiftMaster Gate and Commercial Door Operators • Enables flexible setup for 1 to deliver unbeatable performance in tough environments, LiftMaster® Wireless Keypads enable a more modern, streamlined access solution that can be set for multiple users with 250 permanent PINs and...
LiftMaster KPW Sell Sheet Manual
Page 3
... Pedestal (PED42) • 42 in. steel Universal Receiver (850LM) • Security+ 2.0 Technology • 3 channels for residential gate access, including solar gate applications, as well as smaller commercial door and gate applications. • Designed to work exclusively with Security+ 2.0® • Enables flexible setup with most gate and commercial door operators Allows for removal of a single PIN while maintaining full access for other users • Enclosed in . square pipe • Black...
... Pedestal (PED42) • 42 in. steel Universal Receiver (850LM) • Security+ 2.0 Technology • 3 channels for residential gate access, including solar gate applications, as well as smaller commercial door and gate applications. • Designed to work exclusively with Security+ 2.0® • Enables flexible setup with most gate and commercial door operators Allows for removal of a single PIN while maintaining full access for other users • Enclosed in . square pipe • Black...
LiftMaster KPW Sell Sheet Manual
Page 4
... Temporary PINs KPW5 • LiftMaster Security+ 2.0 - High-Impact Polycarbonate Back Housing KPW5: High-Impact Polycarbonate Front Cover and Back Housing One Year Limited Non-Volatile (Codes Saved When Battery Replaced) Compatible for Surface Mount or Standard Pedestal Mount (4 x 4 in.) Up to 95% (Non-Condensing) Weatherization Electronics Meet NEMA 4X Water Protection Requirements Housing Meets or Exceeds NEMA 3R Enclosure Warranty Memory Mounting Operating Range KPW250...
... Temporary PINs KPW5 • LiftMaster Security+ 2.0 - High-Impact Polycarbonate Back Housing KPW5: High-Impact Polycarbonate Front Cover and Back Housing One Year Limited Non-Volatile (Codes Saved When Battery Replaced) Compatible for Surface Mount or Standard Pedestal Mount (4 x 4 in.) Up to 95% (Non-Condensing) Weatherization Electronics Meet NEMA 4X Water Protection Requirements Housing Meets or Exceeds NEMA 3R Enclosure Warranty Memory Mounting Operating Range KPW250...
LiftMaster KPW Compatibility Chart Manual
Page 1
... Logic 3.0 N/A Any Commercial Door Operator with 412HM Receiver Installed N/A N/A 109020, 109920, 109950, 302850†, 302101 LiftMaster Commercial Receivers STAR1000, 850LM, 860LM 312HM 412HM N/A KPW5 Security+ 2.0 Gate Operators with On-Board Receiver Security+ 2.0 (Tri-Band 310/315/ 390 MHz) Security+ 2.0 Gate Operators with 850LM Receiver Installed CAME Gate Operators Security+ 2.0 Gate Operators with On-Board Receiver (Intro 2014/Q1 2015) Security+ 2.0 Gate Operators (UL 325 New Compliance) Launching in Q4 2015 *Multi-Code is a registered trademark of Nortek Security & Control...
... Logic 3.0 N/A Any Commercial Door Operator with 412HM Receiver Installed N/A N/A 109020, 109920, 109950, 302850†, 302101 LiftMaster Commercial Receivers STAR1000, 850LM, 860LM 312HM 412HM N/A KPW5 Security+ 2.0 Gate Operators with On-Board Receiver Security+ 2.0 (Tri-Band 310/315/ 390 MHz) Security+ 2.0 Gate Operators with 850LM Receiver Installed CAME Gate Operators Security+ 2.0 Gate Operators with On-Board Receiver (Intro 2014/Q1 2015) Security+ 2.0 Gate Operators (UL 325 New Compliance) Launching in Q4 2015 *Multi-Code is a registered trademark of Nortek Security & Control...
KPW5 Manual
Page 1
... pressed. A long tone will sound. The Wireless Commercial Keypad is accidentally entered, an error tone will sound. If an invalid PIN or partial PIN is compatible with one 9V Lithium battery, instructions, and two keys. OVERVIEW Wireless Commercial Keypad Models KPW5 and KPW250 The Wireless Commercial Keypad comes with the brands of commercial door and gate operators listed in the table below. MODEL KPW5 KPW250 FREQUENCY AND ENCRYPTION LiftMaster Security+ 2.0™ Default Tri-band 390 MHz...
... pressed. A long tone will sound. The Wireless Commercial Keypad is accidentally entered, an error tone will sound. If an invalid PIN or partial PIN is compatible with one 9V Lithium battery, instructions, and two keys. OVERVIEW Wireless Commercial Keypad Models KPW5 and KPW250 The Wireless Commercial Keypad comes with the brands of commercial door and gate operators listed in the table below. MODEL KPW5 KPW250 FREQUENCY AND ENCRYPTION LiftMaster Security+ 2.0™ Default Tri-band 390 MHz...
KPW5 Manual
Page 2
... maximum number of PINs is required (factory default code: 888888) to any of inactivity, the keypad will remain in programming mode. INSTALLATION To prevent possible SERIOUS INJURY or DEATH from the mounting plate. 3. Mount the mounting plate to the desired surface and secure with remote controls. • Activate gate or door ONLY when it can be put into programming mode prior to operate the Wireless Commercial Keypad. Mounting plate 4. Remove the battery cover using a Phillips screw driver. The keypad...
... maximum number of PINs is required (factory default code: 888888) to any of inactivity, the keypad will remain in programming mode. INSTALLATION To prevent possible SERIOUS INJURY or DEATH from the mounting plate. 3. Mount the mounting plate to the desired surface and secure with remote controls. • Activate gate or door ONLY when it can be put into programming mode prior to operate the Wireless Commercial Keypad. Mounting plate 4. Remove the battery cover using a Phillips screw driver. The keypad...
KPW5 Manual
Page 3
... Step 4. Enter program mode: (Master Code) # 2 Set frequency and encryption (KPW250 only): • LiftMaster Security+ 315 MHz - Within 30 seconds - NOTE: When entering the DIP Switch sequence 3 beeps will sound if an incorrect number of entries is in the "up" or "on the operator. 5. PROGRAM TO OPERATOR Program to LiftMaster Operator NOTE: The Master Code and a PIN need to Linear Multi-Code Receiver KPW250 ONLY 1. Press 03 # 1 #. Press the Learn Button on " (CLOSED)position place...
... Step 4. Enter program mode: (Master Code) # 2 Set frequency and encryption (KPW250 only): • LiftMaster Security+ 315 MHz - Within 30 seconds - NOTE: When entering the DIP Switch sequence 3 beeps will sound if an incorrect number of entries is in the "up" or "on the operator. 5. PROGRAM TO OPERATOR Program to LiftMaster Operator NOTE: The Master Code and a PIN need to Linear Multi-Code Receiver KPW250 ONLY 1. Press 03 # 1 #. Press the Learn Button on " (CLOSED)position place...
KPW5 Manual
Page 4
... program mode 2. Set Temporary PIN 3. Press and hold RESET button on the control board for 6 seconds, a long tone sounds indicating the Master Code has been reset. All settings will not operate any previously programmed operators until they are reprogrammed. Press and hold the RESET button on the control board for 30 seconds. Enter program mode 2. Exit Program Mode Keystroke Combination * (Master Code) # 05 # (New temporary 4-digit PIN) # (New temporary 4-digit PIN) # Number of uses (9 maximum) # * * # Indicator Long tone Long tone Keypad backlight will turn...
... program mode 2. Set Temporary PIN 3. Press and hold RESET button on the control board for 6 seconds, a long tone sounds indicating the Master Code has been reset. All settings will not operate any previously programmed operators until they are reprogrammed. Press and hold the RESET button on the control board for 30 seconds. Enter program mode 2. Exit Program Mode Keystroke Combination * (Master Code) # 05 # (New temporary 4-digit PIN) # (New temporary 4-digit PIN) # Number of uses (9 maximum) # * * # Indicator Long tone Long tone Keypad backlight will turn...
KPW5 Manual
Page 5
... on Stuck button. Key press turns on Battery may cause undesired operation. PIN won 't learn . PIN already learned. Learn a new PIN. Tested to add a new pin. frequency and encryption (see page 3). Erase a PIN to Comply with the key. 5. To replace the battery: 1. Dispose of this product that it is programmed to the Program the keypad to match the operator's program to the mounting plate and lock with FCC Standards FOR HOME OR OFFICE USE. PIN won 't learn . LiftMaster.com...
... on Stuck button. Key press turns on Battery may cause undesired operation. PIN won 't learn . PIN already learned. Learn a new PIN. Tested to add a new pin. frequency and encryption (see page 3). Erase a PIN to Comply with the key. 5. To replace the battery: 1. Dispose of this product that it is programmed to the Program the keypad to match the operator's program to the mounting plate and lock with FCC Standards FOR HOME OR OFFICE USE. PIN won 't learn . LiftMaster.com...