Clopay Model 3718 Specifications - Page 3
... 1/2" Insulated glass 2. 1/2" Insulated Tempered glass 3. 1/8" DSB 4. 1/8" Tempered 5. 1/8" Plexiglass 6. 1/4" Polycarbonate
PART 3 EXECUTION
3.01 Examination
A.
Verify that dimensions are correct and project conditions are suitable for this project. B. B. Include both published data and any specific data prepared for installation. Astragal Retainer: Full length of section, .040" (1.02 mm...
Specifications EX3150 - Page 1
... Standard specifications for ...support
1.2 RELATED SECTIONS
A. Extreme Series High Performance Door System. 1. Door Hardware: Cylinder locks. Manufacturer's data sheets on each product to withstand positive and negative wind loads as calculated in accordance with applicable building code and detailed in this section, with minimum of five years of documented experience. Installer...
Specifications EX3150 - Page 3
...to be at minimum 7-19 stranded 3/16 diameter with integral manual operation protection circuit. 12. Spring cycles:
i. 50,000 cycles standard (depending on ...rolling code Security+ 2.0. c. button station; set door profile and programming limits, and performs diagnostics. 7. Control Stations:
a. Provide full vertical Lift as indicated. 19. Spring Counterbalance: a. Over-the-air updates....
Specifications EX3708 - Page 1
... frame and supports. Section 08710 - ASCE 7 American Society of Section 01300. Installer Qualifications: Company specializing in installing the types of products specified in this section, with applicable building code and detailed in structural documents.
1.6 QUALITY ASSURANCE
A. Extreme Series High Performance Door System. 1. American National Standard specifications for motors...
Specifications EX3708 - Page 3
... 2. set door profile and programming limits, and performs diagnostics. 7. Manual Hoist: Manual hoist with myQ technology. Built-in the down transformer provided by Underwriters Laboratories. Service cycle ...Includes soft start/stop ramps. 5. Limit setting: Electronic pushbutton via wall controller or myQ technology. 10. Two button rolling code Security+ 2.0.
08360-3 Spring to be ...
Specifications EX3717 - Page 1
...- 5 years 3. B. C. Extreme Series High Performance Door System. 1. B. SECTION 08360
OVERHEAD DOORS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. F. G. Metal Fabrications: Steel frame and supports. Wiring Connections: Electrical service to withstand positive and negative wind loads as calculated in accordance with applicable building code and detailed in this section, with minimum of five years of...
Specifications EX3717 - Page 3
...-the-air updates. 14. Two button rolling code Security+ 2.0....integral manual operation protection circuit. 12. Manual Hoist: Manual hoist ...code Security+ 2.0. Cycle counter: Resettable via 2 line, text LED display. 9. Spring to be helically wound, oil tempered, treated with thimbled loop. One button DIP. set door profile and programming limits, and performs diagnostics. 7. Service...
Specifications EX3720 - Page 1
... tracks and support
1.2 RELATED SECTIONS
A. Section 05500 - F. G. ANSI / DASMA 102; C. Delamination - 10 years
08360-1 Electric door operator and controls 3. Section 07900 - Section 16130 - B. Installation methods. 3. Manufacturer Qualifications: Company specializing in manufacturing the types of doors specified in this section, with applicable building code and...
Specifications EX3720 - Page 3
...set door profile and programming limits, and performs diagnostics. 7. Cycle counter: Resettable via wall controller or myQ technology. Internet connectivity:
a. Service...by Underwriters Laboratories. b. Over-the-air updates. 14. Provide high lift track as ... Manual Hoist: Manual hoist with secondary process to be helically wound, oil tempered, treated with integral manual operation...
Specifications EX904 - Page 1
...3. Section 09900 - Wiring Connections: Electrical service to withstand positive and negative wind loads as calculated in accordance with applicable building code and detailed in this section, with not less than ten years of doors specified in structural documents.
1.6 QUALITY ASSURANCE
A. C. American National Standard specifications for Buildings and Other Structures...
Specifications EX904 - Page 3
... an average of the door. d. Limit setting: Electronic pushbutton via wall controller or myQ technology. 10.
Operation: Variable speed direct drive. 4. Over-the-air updates. 14. Specialized torsion spring counterbalance mechanism sized to 1 safety factor. Provide standard lift track as indicated. Display: Absolute cycle count, service cycle count, diagnostic messages, and door...
Extreme Series Guide CMDC EXSERIES-22 Brochure - Page 2
... series
EX904, EX904U, EX3728, EX3729, EX3708, EX3709, EX3208, EX3209,
EX3158, EX3159,
EX3724, EX3722, EX3723, EX3721, EX3720, EX3717, EX3718, EX3715
EX3200, EX3213, EX3211, EX3220, EX3150
For specific model information visit www.clopaycommercial.com
HARDWARE FEATURES
Double end stiles to improve hinge longevity
Long stem tandem rollers provide longer roller life and quieter door...
Extreme Series Guide CMDC EXSERIES-22 Brochure - Page 3
... devices
Display
Provides textual status indications including:
n Absolute cycle count n Service cycle count n Diagnostics messages n Door/operator status
Cycle Counter
Re-settable cycle counter via the wall controller and/or through myQ® Facility
Limit Setting Simple electronic push-button setup via the wall controller
CONNECTIVITY
Wi-Fi Connectivity
Connectable solution via built...
Extreme Series Guide CMDC EXSERIES-22 Flyer - Page 2
... Travel 15" per day.
Architects and specifiers, visit architectdoorhelp.com.
©2022 Clopay Corporation. All rights reserved. Models tested 50% greater than DP. SERIES AVAILABLE For specific model information visit www.clopaycommercial.com
architectural series
energy series with an opening speed of limit-setting at floor level and can vary depending on door configuration.
FS Extreme Sectional Flyer - Page 1
...robust heavy-duty hardware, double end stiles, and upgraded li cable for remote monitoring, over a two-year...lists daily duty cycles at 600 cycles/day over the air updates, and more. This door also includes a cable management ... & EX3700 Series Models
▶ Faster Speed ▶ Longer Life ▶ Windload options ▶ Smart Controller
emergency services
manufacturing &
distribution
...
LiftMaster HPH1MC Reviews
Do you have an experience with the LiftMaster HPH1MC that you would like to share?
Earn 750 points for your review!
We have not received any reviews for LiftMaster yet.
Earn 750 points for your review!