CSW200501U Setup and Operation Manual - Page 1
ELITE SERIES COMMERCIAL HIGH-TRAFFIC
AC GATE OPERATORS
SETUP AND OPERATION MANUAL
Model SL3000U
SL3000101U
1 HP Single Phase
SL3000103U
1 HP Three Phase
SL3000501U
1/2 HP Single Phase
Model CSW200U
CSW200101U
1 HP Single Phase
CSW200103U
1 HP Three Phase
CSW200501U
1/2 HP Single Phase
LiftMaster 845 Larch Avenue Elmhurst, IL 60126-1196
CSW200501U Setup and Operation Manual - Page 2
... ERASE ALL MONITORED ENTRAPMENT PROTECTION AND VEHICLE DETECTION DEVICES.....17
SETTINGS
18
GATE OPERATOR SETUP EXAMPLES 18
DUAL GATE SETTINGS 19
WIRING
19
SAMS WIRING WITH RELAYS NOT ENERGIZED 19
FIELD WIRING 20
MAINTENANCE
21
MAINTENANCE 21
TROUBLESHOOTING
22
DIAGNOSTIC CODES 22
OPERATOR ALARM 25
ACCESSORIES
26
REPAIR PARTS
27
SL3000U 27
CSW200U 28
WARRANTY
29
1
CSW200501U Setup and Operation Manual - Page 3
... MUST NOT be cleared and secured, at the fuse box BEFORE proceeding. Read the owner's manual.
SAFETY
SAFETY SYMBOL AND SIGNAL WORD REVIEW
When you see this manual and follow all safety instructions.
• DO NOT attempt repair or service of your gate and/or the gate operator if you do not comply with a rigid...
CSW200501U Setup and Operation Manual - Page 7
...refer to Programming). The BIPART DELAY is installed on the left side of the drive...-TO-CLOSE dial to the desired setting (0 to the Troubleshooting section. ON The operator with the...firmware version, and codes. The firmware version will slide to the right when opening. For more information about the codes refer to 180 seconds). CONTROL BOARD
LEARN BUTTON
The LEARN button is factory set...
CSW200501U Setup and Operation Manual - Page 8
...limit positions. 2. Ensure that the gate is used to view the code history (refer to the Troubleshooting section). The gate should have enough force to reach both the ... the TEST BUTTONS. 2. TEST BUTTONS
Used to operate the gate (OPEN, STOP and CLOSE).
The force setting is opening or closing E1 (single entrapment) E2 (double entrapment) OFF state Accessory overload protector opened
7 If...
CSW200501U Setup and Operation Manual - Page 11
... WITH CORRESPONDING SWITCHES Page 11
OPEN CLOSE
EXIT FAIL SWITCH
If the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, faults are ignored (EXIT loop is deactivated it causes an opening or ...to -Close).
10 EXPANSION BOARD REFERENCE
PLUG-IN LOOP DETECTOR INPUTS For Plug-In Loop Detectors (Model LOOPDETLM)
SHADOW INTERUPT EXIT
OPEN CLOSE
POWER
1
EYE ONLY
2
EYE/ EDGE
3
EYE/ ...
CSW200501U Setup and Operation Manual - Page 12
...energized during gate motion. For an additional audible or being Energizes if gate is manually tampered with barrier gate).
Com
AUX Relay 1 N.O. Use with SAMS (Sequenced...out the cycle count (cycle count is on the control board).
Cycle count displayed is 163,000.). After servicing, set all three LED's blink 1,000,000's (e.g. 1 LED blinks 3 times, 2 LED blinks 6 times, ...
CSW200501U Setup and Operation Manual - Page 13
... TERMINALS
FUNCTIONALITY
WIRING EXAMPLE
Open or Close Direction Photoelectric Sensors, the functionality is based on the switch settings (located next to the terminals)
Switch set to CLOSE: gate reverses fully when it hits obstruction
Switch set to OPEN: gate reverses 4 seconds when it hits obstruction
1
EYE ONLY
2
EYE/ EDGE
3
EYE/ EDGE
COM
SBC...
CSW200501U Setup and Operation Manual - Page 15
... operator has error number 50 (maximum run distance), repeat steps 1-4 to set at this cycle.
ADJUSTMENT
To reduce the risk of SEVERE INJURY or DEATH:
• Without a properly installed safety reversal ...the STOP test button when the desired OPEN limit is closed.
2. Model SL3000U
Limit Nuts
14
Limit Switches
Model CSW200U
Limit Cams
Open Limit Switch
Close Limit Switch
NOTE: The ...
CSW200501U Setup and Operation Manual - Page 16
...If the gate does not reverse off the solid object, reduce the force setting by turning the force control slightly counter-clockwise. To erase the limits, ...test.
3. After any adjustments are made, test the operator:
1. The gate should have enough force to be set.
15
Ensure that the gate is equipped with the solid object. ADJUSTMENT
OBSTRUCTION TEST
The operator is stopping at...
CSW200501U Setup and Operation Manual - Page 19
... with SAMS (Sequence Access Management System). light). Use during servicing only to know when system is manually tampered with by being pushed off of close limit. Typically not required.
SETTINGS
GATE OPERATOR SETUP EXAMPLES
The following are example setups for gate that delays upon opening . Your specific site requirements may be different. For DUAL-GATE site...
CSW200501U Setup and Operation Manual - Page 21
...OR (Not Provided)
PLUG-IN LOOP DETECTOR Model LOOPDETLM
EXPANSION BOARD
POWER
NOTE: These switches determine if the corresponding photoelectric sensor or edge sensor will function.
For continued protection against fire and electrocution: • DISCONNECT power BEFORE installing or servicing operator.
WIRING
To protect against fire: • Replace ONLY with fuse of each...
CSW200501U Setup and Operation Manual - Page 22
... be tightened.
Using a digital voltmeter, verify that while at the operator. DESCRIPTION
TASK
Entrapment Protection Devices Warning Signs Manual Disconnect Drive Chain and Sprockets Belt and Pulley Gate Accessories Electrical Chassis Mounting Bolts Operator
Check and test for proper operation...power to the
operator is suggested that the incoming voltage to the operator before servicing.
CSW200501U Setup and Operation Manual - Page 24
... the control board just replaced? If so, erase limits, enter limit setup mode and set limits. Loop Error - May be a short in the loop, or an open connection in the loop. LiftMaster Plug-in Loop Detector only) or an open connection in the loop. May be a short in the code history and some are less...
CSW200501U Setup and Operation Manual - Page 30
...factory-rebuilt parts at no cost to you and returned pre-paid and insured, to our service center for warranty repair. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN ...COVER ANY PROBLEMS CAUSED BY INTERFERENCE. You will be repaired or replaced with the instructions regarding installation, operation, maintenance and testing.
Products returned to Seller for warranty repair, which ...
LiftMaster CSW200101U Reviews
Do you have an experience with the LiftMaster CSW200101U that you would like to share?
Earn 750 points for your review!
We have not received any reviews for LiftMaster yet.
Earn 750 points for your review!