Installation Manual
Page 3
Class II - Restricted Access Vehicular Gate Operator A vehicular gate operator (or system) intended for use in which unauthorized access is prevented via supervision by or servicing the general public. two in the open direction and two in each entrapment zone l Every installation is ...devices. Have a qualified service person make repairs to install external monitored entrapment protection devices in each entrapment zone l This vehicular slide gate operator will operate only after installation of a minimum of INJURY or DEATH: l READ AND FOLLOW ALL INSTRUCTIONS. l NEVER let...
Class II - Restricted Access Vehicular Gate Operator A vehicular gate operator (or system) intended for use in which unauthorized access is prevented via supervision by or servicing the general public. two in the open direction and two in each entrapment zone l Every installation is ...devices. Have a qualified service person make repairs to install external monitored entrapment protection devices in each entrapment zone l This vehicular slide gate operator will operate only after installation of a minimum of INJURY or DEATH: l READ AND FOLLOW ALL INSTRUCTIONS. l NEVER let...
Installation Manual
Page 4
.... Specific safety features include: l Edges Sensors (contact) b. A wireless device shall function under , around or through the openings anywhere in the gate, and in that the gate covers in the line-of-sight of a vehicular horizontal slide gate. For a gate operator utilizing a non-contact sensor: a. c. Improperly designed, installed or maintained systems can create high levels of two...
.... Specific safety features include: l Edges Sensors (contact) b. A wireless device shall function under , around or through the openings anywhere in the gate, and in that the gate covers in the line-of-sight of a vehicular horizontal slide gate. For a gate operator utilizing a non-contact sensor: a. c. Improperly designed, installed or maintained systems can create high levels of two...
Installation Manual
Page 5
... II and Class III vehicular horizontal slide gates: All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade shall be guarded or covered. 2. The gate panel shall include the entire section of 6 ft. (1.83 m) above grade. All openings shall be designed, guarded, or screened from the gate frame shall not be required to comply...
... II and Class III vehicular horizontal slide gates: All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade shall be guarded or covered. 2. The gate panel shall include the entire section of 6 ft. (1.83 m) above grade. All openings shall be designed, guarded, or screened from the gate frame shall not be required to comply...
Installation Manual
Page 14
...SERIOUS INJURY or DEATH from a moving gate. l LiftMaster monitored external entrapment protection devices MUST be used with LiftMaster operators to the manual provided with an external monitored entrapment protection device, protecting both the open and close gate cycles. For testing instructions, refer to ... gate and RIGID objects, such as posts, walls, pillars, columns or operator itself . one in the open direction and one in BOTH the open and close gate cycles. l Entrapment protection devices MUST be installed according to the following UL 325 requirements: l Slide gate ...
...SERIOUS INJURY or DEATH from a moving gate. l LiftMaster monitored external entrapment protection devices MUST be used with LiftMaster operators to the manual provided with an external monitored entrapment protection device, protecting both the open and close gate cycles. For testing instructions, refer to ... gate and RIGID objects, such as posts, walls, pillars, columns or operator itself . one in the open direction and one in BOTH the open and close gate cycles. l Entrapment protection devices MUST be installed according to the following UL 325 requirements: l Slide gate ...
Installation Manual
Page 21
...to OFF. SLIDE GATE APPLICATIONS: Not applicable, set on the primary gate operator control board. INSTALLATION Wired setup Before digging, contact local underground utility locating companies. Connect the wires from the shielded twisted pair cable to Com Link B). Connect the wires from the open limit. l ...shielded twisted pair cable to close limit when opening and be rated at 30 Volt minimum Bipart delay/synchronized close before the other . The operator with dual gate applications and serves two functions: l BIPART DELAY SWING GATE APPLICATIONS: The BIPART DELAY is used in...
...to OFF. SLIDE GATE APPLICATIONS: Not applicable, set on the primary gate operator control board. INSTALLATION Wired setup Before digging, contact local underground utility locating companies. Connect the wires from the shielded twisted pair cable to Com Link B). Connect the wires from the open limit. l ...shielded twisted pair cable to close limit when opening and be rated at 30 Volt minimum Bipart delay/synchronized close before the other . The operator with dual gate applications and serves two functions: l BIPART DELAY SWING GATE APPLICATIONS: The BIPART DELAY is used in...
Installation Manual
Page 23
... travel limits) is adjusted, the other limit. 5. l If one of the MOVE GATE buttons to move gate. l After ANY adjustments are installed. Gate MUST reverse on gate will automatically exit limit setting mode. For slide gate applications the open and close limit. 3. Cycle the gate open and close . NOTE: The TEST buttons on which limit is being set at...
... travel limits) is adjusted, the other limit. 5. l If one of the MOVE GATE buttons to move gate. l After ANY adjustments are installed. Gate MUST reverse on gate will automatically exit limit setting mode. For slide gate applications the open and close limit. 3. Cycle the gate open and close . NOTE: The TEST buttons on which limit is being set at...
Installation Manual
Page 27
...and battery is charging batteries (i.e. Limit Switch Use with by being pushed off of close (timer or control). Connect "Gate Open" indicator (e.g. Gate Attach alert signal (audible or Motion visual alert system). Attach alert signal (audible or visual alert system). PreMotion Delay ... (audible or visual alert system). not running on batteries). Tamper Attach alert signal (audible or (Slide Gates Only) visual alert system) to indicate if gate is below -4°F. Use during servicing only to determine operator cycles. The thermostat MUST be set ...
...and battery is charging batteries (i.e. Limit Switch Use with by being pushed off of close (timer or control). Connect "Gate Open" indicator (e.g. Gate Attach alert signal (audible or Motion visual alert system). Attach alert signal (audible or visual alert system). PreMotion Delay ... (audible or visual alert system). not running on batteries). Tamper Attach alert signal (audible or (Slide Gates Only) visual alert system) to indicate if gate is below -4°F. Use during servicing only to determine operator cycles. The thermostat MUST be set ...
Installation Manual
Page 38
...system. LiftMaster Plug-in . Check limit positions and proper switch function. If rebooting, ensure enough time for alignment or obstruction. Check the second operator for an obstruction, then reprogram the limits. If powered, deactivate the wireless feature and then re-learn the second operator. Slide gate operators ... loss of the battery charge harness. If not, disconnect all power, wait 15 seconds, then reconnect power (reboot). Replace batteries in the open connection in the loop. Check wired input on a 24V system. If so, erase limits, enter limit setup mode and set too tightly...
...system. LiftMaster Plug-in . Check limit positions and proper switch function. If rebooting, ensure enough time for alignment or obstruction. Check the second operator for an obstruction, then reprogram the limits. If powered, deactivate the wireless feature and then re-learn the second operator. Slide gate operators ... loss of the battery charge harness. If not, disconnect all power, wait 15 seconds, then reconnect power (reboot). Replace batteries in the open connection in the loop. Check wired input on a 24V system. If so, erase limits, enter limit setup mode and set too tightly...
Installation Manual
Page 41
... f. Replace wireless control as needed . b. a. Check all Open and Close inputs for a "stuck on " input e. Control board powers up, but cannot set too close (slide gate applications only) Gate does not fully open or fully close when setting limits. Entrapment Protection Device active ...f. Operator does not respond to a wired control/command (example: Open, Close, SBC, etc.) Operator does not respond to...
... f. Replace wireless control as needed . b. a. Check all Open and Close inputs for a "stuck on " input e. Control board powers up, but cannot set too close (slide gate applications only) Gate does not fully open or fully close when setting limits. Entrapment Protection Device active ...f. Operator does not respond to a wired control/command (example: Open, Close, SBC, etc.) Operator does not respond to...
CSL24UL Wiring Diagram
Page 1
...Loop Error 45 Failure or missing loop (SHORT or OPEN LiftMaster Plug-in the manual. 93 RPM / STALL Reversal (Operator 1) RPM /...opening 80 Close input (EYE/EDGE) communication fault from encoder Check the operator cable connections, then reprogram the limits. 35 Max-Run-Time Exceeded Error Check for obstruction. Disconnect all power, wait 15 seconds, then 31 failure. Review power supply and wiring. Slide gate... assembly. 99 Normal Operation No action required WIRING DIAGRAM Model CSL24UL COAXIAL CABLE ANTENNA Control Board DIAGNOSTICS LOOPS CONTROLS Jumper N.C. The...
...Loop Error 45 Failure or missing loop (SHORT or OPEN LiftMaster Plug-in the manual. 93 RPM / STALL Reversal (Operator 1) RPM /...opening 80 Close input (EYE/EDGE) communication fault from encoder Check the operator cable connections, then reprogram the limits. 35 Max-Run-Time Exceeded Error Check for obstruction. Disconnect all power, wait 15 seconds, then 31 failure. Review power supply and wiring. Slide gate... assembly. 99 Normal Operation No action required WIRING DIAGRAM Model CSL24UL COAXIAL CABLE ANTENNA Control Board DIAGNOSTICS LOOPS CONTROLS Jumper N.C. The...
CSL24UL Product Data Sheet
Page 1
...LiftMaster.com DIAGNOSTIC DISPLAY LED diagnostic display WIRELESS DUAL-GATE COMMUNICATION Eliminates expensive conduit costs and unsightly driveway scars POSILOCK® Automatically powers the operator and returns a gate to the closed position when gate is pushed off of closed limit FIRE DEPARTMENT COMPLIANT Allows gate to auto open... MyQ app MONITORED SAFETY INPUTS 6 inputs (main and expansion board) SOLAR-POWER CAPABILITIES Yes. in . CSL24UL SLIDE GATE OPERATOR SECTION 32 31 00 KEY FEATURES BATTERY BACKUP Up to 24 days of AC power or battery depletion...
...LiftMaster.com DIAGNOSTIC DISPLAY LED diagnostic display WIRELESS DUAL-GATE COMMUNICATION Eliminates expensive conduit costs and unsightly driveway scars POSILOCK® Automatically powers the operator and returns a gate to the closed position when gate is pushed off of closed limit FIRE DEPARTMENT COMPLIANT Allows gate to auto open... MyQ app MONITORED SAFETY INPUTS 6 inputs (main and expansion board) SOLAR-POWER CAPABILITIES Yes. in . CSL24UL SLIDE GATE OPERATOR SECTION 32 31 00 KEY FEATURES BATTERY BACKUP Up to 24 days of AC power or battery depletion...
CSL24UL Product Guide
Page 1
... SIGNAL TO VIRTUALLY ELIMINATE INTERFERENCE AND OFFER EXTENDED RANGE. MANUAL DISCONNECT WHEN UNLOCKED ALLOWS GATE TO BE OPEN E D M A NUA L LY. PRODUCT GUIDE CSL24UL 24VDC HIGH-TRAFFIC COMMERCIAL SLIDE GATE OPERATOR SAFETY ADD-ONS: MONITORED THROUGHBEAM PHOTO EYES Enhanced through the myQ App. ...S E A ND A N T I A B IL IT Y. range: 90 ft. MONITORED WIRELESS EDGE KIT Low-energy Bluetooth® connection between a LiftMaster Monitored Resistive Edge and the gate operator; range: 50 ft. Test equipment regularly and follow safety instructions. max. INTERNET GATEWAY Connects myQ-enabled...
... SIGNAL TO VIRTUALLY ELIMINATE INTERFERENCE AND OFFER EXTENDED RANGE. MANUAL DISCONNECT WHEN UNLOCKED ALLOWS GATE TO BE OPEN E D M A NUA L LY. PRODUCT GUIDE CSL24UL 24VDC HIGH-TRAFFIC COMMERCIAL SLIDE GATE OPERATOR SAFETY ADD-ONS: MONITORED THROUGHBEAM PHOTO EYES Enhanced through the myQ App. ...S E A ND A N T I A B IL IT Y. range: 90 ft. MONITORED WIRELESS EDGE KIT Low-energy Bluetooth® connection between a LiftMaster Monitored Resistive Edge and the gate operator; range: 50 ft. Test equipment regularly and follow safety instructions. max. INTERNET GATEWAY Connects myQ-enabled...
CSL24UL Product Guide
Page 2
...(HTR) 140°F (60°C) SLIDE RATING 1,500 1,500 Ibs. 1,000 500 0 50 ft. Detects Obstructions and Reverses Gate When Closing or Stops/Reverses Gate When Opening POSILOCK® - Make Adding Additional Features ...to 50 Remote Controls (Unlimited with 1/4 in. Switched and Unswitched Power CSL24UL 24VDC HIGH-TRAFFIC COMMERCIAL SLIDE GATE OPERATOR COMMERCIAL-GRADE DESIGN - Gold Zinc-Plated Steel for additional information....Visit HomeLink.com for Rust Prevention - All Rights Reserved. LiftMaster, the LiftMaster logo, myQ and the myQ logo are registered trademarks of The Chamberlain Group, ...
...(HTR) 140°F (60°C) SLIDE RATING 1,500 1,500 Ibs. 1,000 500 0 50 ft. Detects Obstructions and Reverses Gate When Closing or Stops/Reverses Gate When Opening POSILOCK® - Make Adding Additional Features ...to 50 Remote Controls (Unlimited with 1/4 in. Switched and Unswitched Power CSL24UL 24VDC HIGH-TRAFFIC COMMERCIAL SLIDE GATE OPERATOR COMMERCIAL-GRADE DESIGN - Gold Zinc-Plated Steel for additional information....Visit HomeLink.com for Rust Prevention - All Rights Reserved. LiftMaster, the LiftMaster logo, myQ and the myQ logo are registered trademarks of The Chamberlain Group, ...
UL 325-Listed Gate Operators Guide
Page 12
... Controls access at gated entrances with wider polarized beam and heater for residential and light commercial gate applications. RSL12UL 12VDC RESIDENTIAL/LIGHT COMMERCIAL SLIDE GATE OPERATOR Ideal for...LiftMaster Monitored Resistive Edge and the gate operator; INTERNET GATEWAY Connects MyQ-enabled gate operators to the Internet and enables control through -beam now with 2,000 unique codes and Versa XS 4.0 software. max. SMART MyQ® TECHNOLOGY ENABLES YOU TO SECURELY CONTROL AND MONITOR YOUR GATE OPERATOR FROM ANYWHERE. WIRELESS DUAL-GATE COMMUNICATION SYNCHRONIZES GATE OPENING...
... Controls access at gated entrances with wider polarized beam and heater for residential and light commercial gate applications. RSL12UL 12VDC RESIDENTIAL/LIGHT COMMERCIAL SLIDE GATE OPERATOR Ideal for...LiftMaster Monitored Resistive Edge and the gate operator; INTERNET GATEWAY Connects MyQ-enabled gate operators to the Internet and enables control through -beam now with 2,000 unique codes and Versa XS 4.0 software. max. SMART MyQ® TECHNOLOGY ENABLES YOU TO SECURELY CONTROL AND MONITOR YOUR GATE OPERATOR FROM ANYWHERE. WIRELESS DUAL-GATE COMMUNICATION SYNCHRONIZES GATE OPENING...
UL 325-Listed Gate Operators Guide
Page 13
...;F (60°C) GATE TRAVEL SPEED 10" per second STANDARD FEATURES. S upplie d) RSL12UL 12VDC RESIDENTIAL/LIGHT COMMERCIAL SLIDE GATE OPERATOR POWER --115VA...Access (Requires Expansion Board) INHERENT REVERSING SENSOR --D e te cts Ob str uctions and R e v e r s e s Gate When Closing or Stops/Reverses Gate When Opening MONITORED SAFETY INPUTS --3 M a i n Boar d , 3 Opt iona l Expansion Board SECURITY+ 2.0® ON-BOARD RADIO RECEIVER... Solution for additional information. © 2018 LiftMaster All Rights Reserved 300 Windsor Drive, Oak Brook, IL 60523 LiftMaster.com UL® and the UL logo ...
...;F (60°C) GATE TRAVEL SPEED 10" per second STANDARD FEATURES. S upplie d) RSL12UL 12VDC RESIDENTIAL/LIGHT COMMERCIAL SLIDE GATE OPERATOR POWER --115VA...Access (Requires Expansion Board) INHERENT REVERSING SENSOR --D e te cts Ob str uctions and R e v e r s e s Gate When Closing or Stops/Reverses Gate When Opening MONITORED SAFETY INPUTS --3 M a i n Boar d , 3 Opt iona l Expansion Board SECURITY+ 2.0® ON-BOARD RADIO RECEIVER... Solution for additional information. © 2018 LiftMaster All Rights Reserved 300 Windsor Drive, Oak Brook, IL 60523 LiftMaster.com UL® and the UL logo ...
UL 325-Listed Gate Operators Guide
Page 16
...-TRAVEL REVERSAL EXTEND OPERATOR HARDWARE LIFE. MONITORED WIRELESS EDGE KIT Low-energy Bluetooth® connection between a LiftMaster Monitored Resistive Edge and the gate operator; range: 130 ft.* MONITORED SAFETY ENTRAPMENT EDGES Full line of Standby Power IGHLIGHT INCLUDED ACCESSORIES: ...RESISTIVE EDGE Pressure-sensitive edge stops and/or reverses gate when obstructed. FIRE DEPARTMENT COMPLIANCE ALLOWS GATE TO AUTO-OPEN UPON LOSS OF AC POWER OR BATTERY DEPLETION. PRODUCT GUIDE CSL24UL 24VDC HIGH-TRAFFIC COMMERCIAL SLIDE GATE OPERATOR SAFETY ADD-ONS: MONITORED THROUGHBEAM PHOTO EYES...
...-TRAVEL REVERSAL EXTEND OPERATOR HARDWARE LIFE. MONITORED WIRELESS EDGE KIT Low-energy Bluetooth® connection between a LiftMaster Monitored Resistive Edge and the gate operator; range: 130 ft.* MONITORED SAFETY ENTRAPMENT EDGES Full line of Standby Power IGHLIGHT INCLUDED ACCESSORIES: ...RESISTIVE EDGE Pressure-sensitive edge stops and/or reverses gate when obstructed. FIRE DEPARTMENT COMPLIANCE ALLOWS GATE TO AUTO-OPEN UPON LOSS OF AC POWER OR BATTERY DEPLETION. PRODUCT GUIDE CSL24UL 24VDC HIGH-TRAFFIC COMMERCIAL SLIDE GATE OPERATOR SAFETY ADD-ONS: MONITORED THROUGHBEAM PHOTO EYES...
UL 325-Listed Gate Operators Guide
Page 17
...CSL24UL 24VDC HIGH-TRAFFIC COMMERCIAL SLIDE GATE OPERATOR TEMPERATURE SPECIFICATIONS WITHOUT HEATER -4°F (-20°C) WITHOUT HEATER 140°F (60°C) WITH HEATER (HTR) -40°F (-40°C) WITH HEATER (HTR) 140°F (60°C) SLIDE...REVERSING SENSOR --De te cts Ob str uctions and R e v e r s e s Gate When Closing or Stops/Reverses Gate When Opening POSILOCK® --Auto ma tically Clos es t he G a te Whe n It Is ...t eel for additional information. © 2018 LiftMaster All Rights Reserved 300 Windsor Drive, Oak Brook, IL 60523 LiftMaster.com UL® and the UL logo are ...
...CSL24UL 24VDC HIGH-TRAFFIC COMMERCIAL SLIDE GATE OPERATOR TEMPERATURE SPECIFICATIONS WITHOUT HEATER -4°F (-20°C) WITHOUT HEATER 140°F (60°C) WITH HEATER (HTR) -40°F (-40°C) WITH HEATER (HTR) 140°F (60°C) SLIDE...REVERSING SENSOR --De te cts Ob str uctions and R e v e r s e s Gate When Closing or Stops/Reverses Gate When Opening POSILOCK® --Auto ma tically Clos es t he G a te Whe n It Is ...t eel for additional information. © 2018 LiftMaster All Rights Reserved 300 Windsor Drive, Oak Brook, IL 60523 LiftMaster.com UL® and the UL logo are ...
UL 325-Listed Gate Operators Guide
Page 22
...ft. max. MONITORED SMALL PROFILE RESISTIVE EDGE Pressure-sensitive edge stops and/or reverses gate when obstructed. MONITORED WIRELESS EDGE KIT Low-energy Bluetooth® connection between a LiftMaster Monitored Resistive Edge and the gate operator; SURGE SUPPRESSION PROVIDES INDUSTRIAL SURGE AND LIGHTNING PROTE C T I DES U ...SLIDE GATE OPERATOR INCLUDED ACCESSORIES: MONITORED RETROREFLECTIVE PHOTO EYE Enhanced retro-reflective photo eye now with Versa XS 4.0 software. INHERENT REVERSING SENSOR DETECTS OBSTRUCTIONS AND REVERSES GATE WHEN CLOSING OR STOPS/REVERSES THE GATE WHEN OPENING...
...ft. max. MONITORED SMALL PROFILE RESISTIVE EDGE Pressure-sensitive edge stops and/or reverses gate when obstructed. MONITORED WIRELESS EDGE KIT Low-energy Bluetooth® connection between a LiftMaster Monitored Resistive Edge and the gate operator; SURGE SUPPRESSION PROVIDES INDUSTRIAL SURGE AND LIGHTNING PROTE C T I DES U ...SLIDE GATE OPERATOR INCLUDED ACCESSORIES: MONITORED RETROREFLECTIVE PHOTO EYE Enhanced retro-reflective photo eye now with Versa XS 4.0 software. INHERENT REVERSING SENSOR DETECTS OBSTRUCTIONS AND REVERSES GATE WHEN CLOSING OR STOPS/REVERSES THE GATE WHEN OPENING...
UL 325-Listed Gate Operators Guide
Page 53
...come in . For your records, take a photograph of injury. The minimum height of the gate in the open position. GETTING STARTED WITH SWING AND SLIDE GATE OPERATOR. with UL 325 & ASTM F2200 standards. • Only install the operator on ... safe gate access systems in zone. It is clearly designated. Guide posts V track (gate rail) Physical stop - See Illustrations below. FIGURE 5 Earth ground ENTRAPMENT Curb Pedestrian gate located near the slide gate. SLIDE GATE OPENINGS GUIDELINES FIGURE 3 Openings of gate Edge sensor (Draw-in zone) Slide Gate Gaps ...
...come in . For your records, take a photograph of injury. The minimum height of the gate in the open position. GETTING STARTED WITH SWING AND SLIDE GATE OPERATOR. with UL 325 & ASTM F2200 standards. • Only install the operator on ... safe gate access systems in zone. It is clearly designated. Guide posts V track (gate rail) Physical stop - See Illustrations below. FIGURE 5 Earth ground ENTRAPMENT Curb Pedestrian gate located near the slide gate. SLIDE GATE OPENINGS GUIDELINES FIGURE 3 Openings of gate Edge sensor (Draw-in zone) Slide Gate Gaps ...
UPDATED Gate Safety Checklist
Page 2
...records, take a photograph of injury. Photo eye (public side) Photo eye (public side) Photo eyes SLIDE GATE SPACING GUIDELINES FIGURE 2 Slide Gate Gaps A gap, measured in the Open direction) Physical stop Photo eye Emitter or Re ector (Close direction) ZONE Edge sensor on Trailing Edge...NOTE: Any gap larger than 2 1/4" or else be applied to place the WARNING signs on both entrapment protection devices. SLIDE GATE OPENINGS GUIDELINES FIGURE 3 Openings of a horizontal slide gate must be smaller than 2¼" (57 mm) between vertical bars must be less than 2¼" (57 mm) ...
...records, take a photograph of injury. Photo eye (public side) Photo eye (public side) Photo eyes SLIDE GATE SPACING GUIDELINES FIGURE 2 Slide Gate Gaps A gap, measured in the Open direction) Physical stop Photo eye Emitter or Re ector (Close direction) ZONE Edge sensor on Trailing Edge...NOTE: Any gap larger than 2 1/4" or else be applied to place the WARNING signs on both entrapment protection devices. SLIDE GATE OPENINGS GUIDELINES FIGURE 3 Openings of a horizontal slide gate must be smaller than 2¼" (57 mm) between vertical bars must be less than 2¼" (57 mm) ...