Get support for LiftMaster CSL24UL

LiftMaster CSL24UL Support Question

LiftMaster CSL24UL Support Question

Find answers below for this question about LiftMaster CSL24UL.
Need a LiftMaster CSL24UL manual? We have 14 online manuals for this item!
Question posted by leebaxter13 on April 22nd, 2022

How To Set A New Code On The Code Box. The Gate Also Has Active Remotes.

The person who posted this question about this LiftMaster product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by SonuKumar on April 22nd, 2022 8:06 PM
This answer was accepted by the poster of the original question.
SonuKumar

Member since:
May 9th, 2021

Points: 16,622,280
1,100
points
https://cdn.controlledproducts.net/docs-www/CSL24UL_Installation%20Manual.pdf

https://www.youtube.com/watch?v=KHc5_SVYCPU

above link for reset

How do you program a LiftMaster sliding gate remote?

HOW TO PROGRAM A STANDARD LIFTMASTER REMOTE CONTROL

Locate the "Learn" button on your garage door opener. ...

Press and release the "Learn" button.

Within 30 seconds of pressing the "Learn" button, press and hold the button you wish to program on the remote control for three seconds, then release.

https://www.creativedoor.com/blog/how-to-program-your-liftmaster-garage-door-opener-remote-control


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.

Regards,
Sonu
Your search handyman for all e-support needs!!

Related LiftMaster CSL24UL Manual Pages

Installation Manual - Page 2

...25 Remote Controls (Not Provided 25 LiftMaster Internet Gateway (not provided 26 Erase All Codes 26 Erase Limits 26 Constant Pressure Override (CPO 26 Gate Hold Open ...Codes 37 Diagnostic Codes Table 38 Control Board LEDs 40 Troubleshooting Chart 41 APPENDIX 44 Step 6 Solar Panel(s 44 SAMS Wiring With Relays Not Energized 48 Dual Gate Settings 48 Limit Setup With a Remote...
Installation Manual - Page 4

...-of-sight of many component parts. The pedestrian access opening shall be located where the transmission of the signals are guarded or screened from the bottom of the gate to activate, must be located and its function as one line-of-sight of the gate. Vehicular gate systems provide convenience and security. component part of...
Installation Manual - Page 16

... may be made by a qualified individual. For dual gate applications, power will be a single, whole piece of the remote controls will be reduced and the operator will have to... output voltage of maintenance the area MUST be cleared and secured, at the fuse box BEFORE proceeding. Follow the directions according to be wired for either 120 Vac or ... national and local electrical codes.
Installation Manual - Page 23

... the operator will interfere with electronic controls to compensate for a binding or sticking gate. l After ANY adjustments are set at least four feet apart. 1. Setting the limits with a Remote Control in the open and close . For slide gate applications the open and close the gate. Gate MUST reverse on which limit is adjusted automatically when you to the other...
Installation Manual - Page 25

... additional Security+ 2.0® remote controls or remote control buttons, repeat the programming steps above. Within 30 seconds, when the gate/door is at the open , close the gate. When programming a third ...operator will beep and green XMITTER LED will light). Press the remote control button that to which can be set to be programmed. This device has been tested and found to ...
Installation Manual - Page 26

... gate hold open feature: 1. Within 30 seconds, when the gate is intended to temporarily override a fault in the entrapment protection system, in learn mode for complete programming instructions). To use Constant Pressure Override: 1. Activate a Hard input or a programmed remote To Remove and Erase Monitored Entrapment Protection Devices 1. Press and release the SET OPEN and SET...
Installation Manual - Page 27

... alert system). Aux Relay Out - Attach visual alert to OPEN. Attach alert signal (audible or visual alert system) to BATT. Connect emergency access system (Knox box switch, SOS system, etc.). Always setup the operator system to ON. Low Battery switch setting Normally set to indicate if gate is charging batteries (i.e. Aux Relay Out - Attach alert...
Installation Manual - Page 28

... command input overrides to be set to automatically close the gate after the operator type, example "1.2". 12 BACKDRIVE Switch: Set to MANUAL will allow the gate to open or close the gate. l Critically low battery is less than 23 V 5 BIPART DELAY Switch: The LOCK/BIPART DELAY switch is used only for programming remote controls and the network...
Installation Manual - Page 31

...-Close momentary input logic as hard open gate. Accessory power 24 VDC, MAX 500 mA (4 Terminals) l SWITCHED: Switched ON with gate motion and at the open limit when Timer-to motor activation and during motor run. Relay activates prior to -Close is off 5 seconds after motion. Opens a closing gate and holds open an open (maintained switch overrides external safeties and...
Installation Manual - Page 35

...GATE. l NEVER let children operate or play with l KEEP GATES PROPERLY MAINTAINED. l Activate gate ONLY when it still complies with an object or reverse when an object activates the noncontact sensors. l Limits may be taken at the fuse box BEFORE proceeding. The gate... moving. l Test the gate operator monthly. Keep the remote control away from the gate. l It is for ...
Installation Manual - Page 37

...) to exit. TROUBLESHOOTING To protect against fire: l Replace ONLY with fuse of same type and rating. The code history has now been reset and the display will start saving over the oldest codes as new codes occur. 37 The operator will only keep track of inactivity. The display will show on the diagnostic display...
Installation Manual - Page 38

... wired input for an obstruction, then reprogram the limits. If a code is not saved it will briefly appear on a 12V system. Check... the wireless feature and then re-learn the second operator. Slide gate operators require a minimum of the battery charge harness. Check wired ... and one in the open connection in the loop. If so, erase limits, enter limit setup mode and set too tightly against a...
Installation Manual - Page 42

... test and perform the proper force adjustment that activating edge sensor causes moving gate to stop or reverse gate. Shadow loop does not keep gate at open . Check if AC power is set to open limit. a. Check edge sensor wiring. a. Pre-warning is available. Exit loop activation does not cause gate to "ON" b. Low battery a. Charge batteries by AC...
Installation Manual - Page 43

...accessory voltage after every new connection. Check AUX Relay switches settings b. a. Accessories connected to either N.O. AUX Relay not working correctly. Accessory power protector active b. Interrupt loop detector...b. TROUBLESHOOTING SYMPTOM Expansion board function not controlling gate. Maglock not working correctly. POSSIBLE CAUSES a. Excessive accessory power draw c. If...
Installation Manual - Page 49

... with a Remote Control To set the limits using a remote control, first you will automatically exit limit setting mode. Press and release the SET OPEN and SET CLOSE buttons simultaneously to set the open limit. Press and hold the OPEN button on the remote control again to enter limit setting mode. 2. Press and release the OPEN button on the remote control until the gate reaches the...
Installation Manual - Page 52

...button remote control The 3-button remote control can control garage door(s). ...remote controls One button can control a gate operator and the other (s) can be programmed to 1,000 devices (any combination of 10). Model 877MAX Wireless commercial keypad Durable wireless keypad with operators manufactured by entering a 4-digit code on a specially designed keypad. The following remote...
Installation Manual - Page 53

... will then open the gate. Requires a 33AH battery harness. Ideal for use with operator. Model LD7LP Vehicle sensing probe The vehicle sensing probe is below -4°F (-20°C). Model K10-34758-2 Universal solar wire harness kit For 7AH and 33AH applications. ACCESSORIES Miscellaneous Post-mounting plate For post-mounting models CSL24UL, CSW24UL CSW200UL...
Installation Manual - Page 54

... RELATING TO, THE GATE OR GATE HARDWARE, INCLUDING BUT NOT LIMITED TO THE GATE SPRINGS, GATE ROLLERS, GATE ALIGNMENT OR HINGES. THIS.../ 5 YEAR COMMERCIAL LIMITED WARRANTY PERIOD SET FORTH ABOVE [EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE CSL24UL, WHICH ARE LIMITED IN DURATION TO...states do not allow limitations on your compliance with new or factoryrebuilt parts at no cost to you call...
UL 325-Listed Gate Operators Guide - Page 12

...ED R E L IA B IL IT Y. FIRE DEPARTMENT COMPLIANCE ALLOWS GATE TO AUTO-OPEN UPON LOSS OF AC POWER OR BATTERY DEPLETION. SAFETY ADD-ONS: ...residential and light commercial gate applications. RSL12UL 12VDC RESIDENTIAL/LIGHT COMMERCIAL SLIDE GATE OPERATOR Ideal for up to stay aligned; BACKUP Provides up to the Internet and enables control through -beam now with 2,000 unique codes and Versa XS ...
UL 325-Listed Gate Operators Guide - Page 47

... 500 ft. (Open Field) Up to 500 ft. (Open Field) Dimensions ...Activations per Day) 5 Years (Based on Tri-Band 310/315/390 MHz • LiftMaster Security+® 315 MHz • LiftMaster Security+ 390 MHz • Linear Multi-Code® 300 MHz • LiftMaster Security+ 2.0 (Default) - BASIC INPUT / OUTPUT Number of Gates / Doors of Control Wiegand Inputs Additional Gate / Door...Box...

Similar Questions

I Have Installed A Chamberlan Garage Door Opener And The Remote I Was Using Is
I have been using a Chamberlan garage door opener and its remote has been defective since of late.Pl...
(Posted by donweera42 8 months ago)
Csl24ul Ac Power
Does the CSL24UL have AC power when it is powered only by solar
(Posted by lesmeier03 9 months ago)
Change Time To Open Gate
how do I change time the gate will open if I use the correct cide?
(Posted by So1673 1 year ago)
Remote Control For Liftmaster /chamberlain 3850 Garage Door Opener
what is the correct remote control for the chamberlain/liftmaster 3850 garage door opener
(Posted by sendtoalice 9 years ago)
Resetting The Key Code For Garage Door Opener
How do you reset the key code for the garage door opener?
(Posted by khiggins69 12 years ago)
Ask a New Question
Use the box below to post a new question about this LiftMaster product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LiftMaster Manuals

Find free LiftMaster CSL24UL manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LiftMaster Reviews

View thousands of LiftMaster user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LiftMaster customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LiftMaster customer service rankings, employee comments and much more from our sister site.