EDS-MD - Product Brief
Page 1
With Lantronix' proprietary Secure Com Port Redirector™ virtualization software, existing serial port applications can be affected. EDS-MD Highlights: > UL and IEC-60601 compliance provides port isolation to protect connected medical devices > Securely connect any medical ... device servers over the Internet with a Gigabit (10/100/1000Mpbs) network interface. EDS-MD boasts 4, 8 or 16 individually isolated RS-232 serial ports with the highest level of sensitive information to EDS-MD and encrypted at both ends of the communication, allowing the transport of security. Virtual...
With Lantronix' proprietary Secure Com Port Redirector™ virtualization software, existing serial port applications can be affected. EDS-MD Highlights: > UL and IEC-60601 compliance provides port isolation to protect connected medical devices > Securely connect any medical ... device servers over the Internet with a Gigabit (10/100/1000Mpbs) network interface. EDS-MD boasts 4, 8 or 16 individually isolated RS-232 serial ports with the highest level of sensitive information to EDS-MD and encrypted at both ends of the communication, allowing the transport of security. Virtual...
EDS-MD - Product Brief
Page 2
... C22.2; Specifications subject to 921 Kbps > Part Number EDSOR04P-01 EDSOR08P-01 EDSOR16P-01 > Description EDS-MD 4-PORT DEVICE SERVER, ROHS EDS-MD 8-PORT DEVICE SERVER, ROHS EDS-MD 16-PORT DEVICE SERVER, ROHS • ESD Protection - 15kV • Circuit and port isolation - ...Electrical Equipment > Power • Input: IEC60320 C14 receptacle without notice. and Lantronix are registered trademarks, and EDS-MD, Secure Com Port Redirector and DeviceInstaller are the property of Lantronix, Inc. EDS-MD Features > Standards Ordering Information • IEEE 802.3 • IEEE 802...
... C22.2; Specifications subject to 921 Kbps > Part Number EDSOR04P-01 EDSOR08P-01 EDSOR16P-01 > Description EDS-MD 4-PORT DEVICE SERVER, ROHS EDS-MD 8-PORT DEVICE SERVER, ROHS EDS-MD 16-PORT DEVICE SERVER, ROHS • ESD Protection - 15kV • Circuit and port isolation - ...Electrical Equipment > Power • Input: IEC60320 C14 receptacle without notice. and Lantronix are registered trademarks, and EDS-MD, Secure Com Port Redirector and DeviceInstaller are the property of Lantronix, Inc. EDS-MD Features > Standards Ordering Information • IEEE 802.3 • IEEE 802...
EDS-MD - Product Brief (A4 Format)
Page 1
With Lantronix' proprietary Secure Com Port Redirector™ virtualization software, existing serial port applications can be affected. Virtual COM ports can work with EDS-MD without any code modifications. EDS-MD Highlights: > UL and IEC-60601 compliance provides port isolation to protect connected medical ... of EDS-MD is simple with industrystandard management tools including Web, CLI and XML. Going above and beyond the IEC-60601 requirement, EDS-MD provides galvanic isolation on all ports to ensure the highest levels of safety. EDS-MD boasts 4, 8 or 16 individually ...
With Lantronix' proprietary Secure Com Port Redirector™ virtualization software, existing serial port applications can be affected. Virtual COM ports can work with EDS-MD without any code modifications. EDS-MD Highlights: > UL and IEC-60601 compliance provides port isolation to protect connected medical ... of EDS-MD is simple with industrystandard management tools including Web, CLI and XML. Going above and beyond the IEC-60601 requirement, EDS-MD provides galvanic isolation on all ports to ensure the highest levels of safety. EDS-MD boasts 4, 8 or 16 individually ...
EDS-MD - Product Brief (A4 Format)
Page 2
.... 601.1: 1990; and Lantronix are registered trademarks, and EDS-MD, Secure Com Port Redirector and DeviceInstaller are the property of Lantronix, Inc. up • Onboard Thermal Sensor > Part Number EDSOR04P-01-R > Description EDS-MD 4-PORT DEVICE SERVER, ROHS > Physical Interface 4/8/16 RJ45 (DTE) Serial Connectors EDSOR08P-01-R EDSOR16P-01-R EDS-MD 8-PORT DEVICE SERVER, ROHS EDS-MD 16-PORT DEVICE SERVER, ROHS...
.... 601.1: 1990; and Lantronix are registered trademarks, and EDS-MD, Secure Com Port Redirector and DeviceInstaller are the property of Lantronix, Inc. up • Onboard Thermal Sensor > Part Number EDSOR04P-01-R > Description EDS-MD 4-PORT DEVICE SERVER, ROHS > Physical Interface 4/8/16 RJ45 (DTE) Serial Connectors EDSOR08P-01-R EDSOR16P-01-R EDS-MD 8-PORT DEVICE SERVER, ROHS EDS-MD 16-PORT DEVICE SERVER, ROHS...
EDS-MD - User Guide
Page 3
... of Figures 12 List of Tables 13 1: Using This Guide 15 Purpose and Audience 15 Summary of Chapters 15 Safety Information 16 Cover 16 Power Plug 16 Input Supply 16 Grounding 16 Fuses 16 Battery 17 Wall Mounting 17 Port Connections 17 Equipment Classifications 18 Environmental Conditions for Transportation and Storage 18 Cleaning Instructions 18 Electromagnetic... 20 Troubleshooting Capabilities 21 Configuration Methods 21 Addresses and Port Numbers 21 Hardware Address 21 IP Address 21 Port Numbers 22 Product Information Label 22 EDS-MD User Guide 3
... of Figures 12 List of Tables 13 1: Using This Guide 15 Purpose and Audience 15 Summary of Chapters 15 Safety Information 16 Cover 16 Power Plug 16 Input Supply 16 Grounding 16 Fuses 16 Battery 17 Wall Mounting 17 Port Connections 17 Equipment Classifications 18 Environmental Conditions for Transportation and Storage 18 Cleaning Instructions 18 Electromagnetic... 20 Troubleshooting Capabilities 21 Configuration Methods 21 Addresses and Port Numbers 21 Hardware Address 21 IP Address 21 Port Numbers 22 Product Information Label 22 EDS-MD User Guide 3
EDS-MD - User Guide
Page 4
...EDS-MD4/8/16 Device Servers 23 Package Contents 23 User-Supplied Items 23 Identifying Hardware Components 23 Serial Ports 24 Ethernet Port 24 LEDs 24 Reset to Default Button 25 To restore factory default settings 25 Technical Specification 26 Installing the EDS-MD 27 Finding a Suitable Location 27 Connect the EDS-MD... to one or more serial devices 27 4: Using DeviceInstaller 28 Accessing EDS-MD Using DeviceInstaller 28 Device Detail Summary 28 5: ...
...EDS-MD4/8/16 Device Servers 23 Package Contents 23 User-Supplied Items 23 Identifying Hardware Components 23 Serial Ports 24 Ethernet Port 24 LEDs 24 Reset to Default Button 25 To restore factory default settings 25 Technical Specification 26 Installing the EDS-MD 27 Finding a Suitable Location 27 Connect the EDS-MD... to one or more serial devices 27 4: Using DeviceInstaller 28 Accessing EDS-MD Using DeviceInstaller 28 Device Detail Summary 28 5: ...
EDS-MD - User Guide
Page 11
...(VIP) Counters 83 To View VIP Counters 83 Using Web Manager 83 Using the CLI 83 Using XML 83 15: Branding the EDS-MD4/8/16 84 Web Manager Customization 84 Short and Long Name Customization 85 To Customize Short or Long Names 85 Using Web Manager 85 Using the... Support 86 Appendix B: Binary to Hexadecimal Conversions 87 Converting Binary to Hexadecimal 87 Conversion Table 87 Scientific Calculator 87 Appendix C: Compliance 89 Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts 93 Cables and Adapters 93 Adapters and Serial Port Pinouts 94 EDS-MD User Guide 11
...(VIP) Counters 83 To View VIP Counters 83 Using Web Manager 83 Using the CLI 83 Using XML 83 15: Branding the EDS-MD4/8/16 84 Web Manager Customization 84 Short and Long Name Customization 85 To Customize Short or Long Names 85 Using Web Manager 85 Using the... Support 86 Appendix B: Binary to Hexadecimal Conversions 87 Converting Binary to Hexadecimal 87 Conversion Table 87 Scientific Calculator 87 Appendix C: Compliance 89 Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts 93 Cables and Adapters 93 Adapters and Serial Port Pinouts 94 EDS-MD User Guide 11
EDS-MD - User Guide
Page 15
... guide provides the information needed to Hexadecimal Conversions Appendix C: Compliance Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts Description Main features of the three models. Instructions for system integrators who are commonly referred to as either EDS-MD4/8/16 or as EDS-MD when mentioned within a description equally applicable to any of the product and...
... guide provides the information needed to Hexadecimal Conversions Appendix C: Compliance Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts Description Main features of the three models. Instructions for system integrators who are commonly referred to as either EDS-MD4/8/16 or as EDS-MD when mentioned within a description equally applicable to any of the product and...
EDS-MD - User Guide
Page 16
...help protect the product from sudden, transient increases and decreases in the presence of the EDS-MD. Note: Unit is no user-serviceable parts inside. EDS-MD User Guide 16 Do not operate the EDS-MD if the housing is not suitable for use a power cord with a power cord for... to the branch circuit. Input Supply Check nameplate ratings to Lantronix. Grounding Maintain reliable grounding of supply circuits that should be followed when installing and operating the EDS-MD. 1: Using This Guide Safety Information This section describes the safety precautions ...
...help protect the product from sudden, transient increases and decreases in the presence of the EDS-MD. Note: Unit is no user-serviceable parts inside. EDS-MD User Guide 16 Do not operate the EDS-MD if the housing is not suitable for use a power cord with a power cord for... to the branch circuit. Input Supply Check nameplate ratings to Lantronix. Grounding Maintain reliable grounding of supply circuits that should be followed when installing and operating the EDS-MD. 1: Using This Guide Safety Information This section describes the safety precautions ...
EDS-MD - User Guide
Page 20
...family. Patient Monitoring Devices Glucose Analyzers Infusion Pumps Protocol Support The EDS-MD4/8/16 device server contains a full-featured IP stack. EDS-MD models are complete networkenabling solutions. Hardware/Software handshaking capability. Custom/standard baud rates up to 921600 ... and cross-over cables are OK to use) Serial Ports: 4 to 16 ports depending on model (EDS-MD4, EDS-MD8 or EDS-MD16), electrically isolated from one another and other circuits. EDS-MD User Guide 20 Supported protocols include: ARP, UDP, TCP, ICMP, DHCP...
...family. Patient Monitoring Devices Glucose Analyzers Infusion Pumps Protocol Support The EDS-MD4/8/16 device server contains a full-featured IP stack. EDS-MD models are complete networkenabling solutions. Hardware/Software handshaking capability. Custom/standard baud rates up to 921600 ... and cross-over cables are OK to use) Serial Ports: 4 to 16 ports depending on model (EDS-MD4, EDS-MD8 or EDS-MD16), electrically isolated from one another and other circuits. EDS-MD User Guide 20 Supported protocols include: ARP, UDP, TCP, ICMP, DHCP...
EDS-MD - User Guide
Page 21
... XML is also referred to users and administrators. This address references the specific unit. Configuration Methods After installation, the EDS-MD4/8/16 requires configuration. EDS-MD User Guide 21 For the unit to an IP network must have a unique IP address. Available from the CLI ...View all settings easily through a web browser using the Lantronix Web Manager. (See "Configuration Using Web Manager" on page 30.) DeviceInstaller: Configure the IP address and related settings and view current settings on the EDS-MD4, EDS-MD8 and EDS-MD16 using a Graphical User Interface (GUI) on ...
... XML is also referred to users and administrators. This address references the specific unit. Configuration Methods After installation, the EDS-MD4/8/16 requires configuration. EDS-MD User Guide 21 For the unit to an IP network must have a unique IP address. Available from the CLI ...View all settings easily through a web browser using the Lantronix Web Manager. (See "Configuration Using Web Manager" on page 30.) DeviceInstaller: Configure the IP address and related settings and view current settings on the EDS-MD4, EDS-MD8 and EDS-MD16 using a Graphical User Interface (GUI) on ...
EDS-MD - User Guide
Page 22
... Serial Number (MAC Address) Manufacturing Date Code Note: The hardware address on the product type. Figure 2-1 EDS-MD Product Label Bar Code Serial Number Part Number SN: XXXXXXXXXXXXX PN: XXXXXXXXXXXXX Made In: XXXXXXX Rev: XXX YYWWW Revision Manufacturing Date Code.../8/16: TCP Port 22: SSH Server (Command Mode configuration) TCP Port 23: Telnet Server (Command Mode configuration) TCP Port 80: HTTP (Web Manager configuration) TCP Port 21: FTP UDP Port 30718: LDP (Lantronix Discovery Protocol) port TCP/UDP Port...
... Serial Number (MAC Address) Manufacturing Date Code Note: The hardware address on the product type. Figure 2-1 EDS-MD Product Label Bar Code Serial Number Part Number SN: XXXXXXXXXXXXX PN: XXXXXXXXXXXXX Made In: XXXXXXX Rev: XXX YYWWW Revision Manufacturing Date Code.../8/16: TCP Port 22: SSH Server (Command Mode configuration) TCP Port 23: Telnet Server (Command Mode configuration) TCP Port 80: HTTP (Web Manager configuration) TCP Port 21: FTP UDP Port 30718: LDP (Lantronix Discovery Protocol) port TCP/UDP Port...
EDS-MD - User Guide
Page 23
... support the RS-232C (EIA-232) standard. All devices attached to the EDS-MD4/8/16. Identifying Hardware Components Figure 3-1 shows the front of the Lantronix cables and adapters you need the following items: One EDS-MD device server (an EDS-MD4, EDS-MD8 or EDS-MD16) One RJ45 CAT 5E cable (part number 500-207-R) for...
... support the RS-232C (EIA-232) standard. All devices attached to the EDS-MD4/8/16. Identifying Hardware Components Figure 3-1 shows the front of the Lantronix cables and adapters you need the following items: One EDS-MD device server (an EDS-MD4, EDS-MD8 or EDS-MD16) One RJ45 CAT 5E cable (part number 500-207-R) for...
EDS-MD - User Guide
Page 24
... port LEDs indicate Speed, Activity, Power, and Status. LED Steady Green Off Table 3-3 System LEDs on the back of the EDS-MD shows the connection of the EDS-MD4/8/16 provides a network interface via the "Main 1" RJ45 port. Ethernet Port The back panel of the attached Ethernet network. The... EDS-MD4/8/16 can connect to operate at 10/100/1000Base-T. or full-duplex). Otherwise by default, the EDS-MD auto-negotiates the connection to 921600 baud. Unit powered down or not operational. The Speed...
... port LEDs indicate Speed, Activity, Power, and Status. LED Steady Green Off Table 3-3 System LEDs on the back of the EDS-MD shows the connection of the EDS-MD4/8/16 provides a network interface via the "Main 1" RJ45 port. Ethernet Port The back panel of the attached Ethernet network. The... EDS-MD4/8/16 can connect to operate at 10/100/1000Base-T. or full-duplex). Otherwise by default, the EDS-MD auto-negotiates the connection to 921600 baud. Unit powered down or not operational. The Speed...
EDS-MD - User Guide
Page 25
... button. The firmware restores factory default settings to -default button for a minimum of 25 seconds. 3. 3: Installation of EDS-MD4/8/16 Device Servers LED Green Red Off Table 3-4 Serial Indicator LEDs on the Top of EDS-MD Description Indicates there is located on the side of the housing, accessible with a paper clip or other similar...
... button. The firmware restores factory default settings to -default button for a minimum of 25 seconds. 3. 3: Installation of EDS-MD4/8/16 Device Servers LED Green Red Off Table 3-4 Serial Indicator LEDs on the Top of EDS-MD Description Indicates there is located on the side of the housing, accessible with a paper clip or other similar...
EDS-MD - User Guide
Page 26
... 2 of USB-A Host, USB 2.0, Full Speed only 0.5 A 1.5 KVAC 1.5 KVAC Options of EDS-MD4/8/16 Device Servers Technical Specification Category NETWORK INTERFACE Ethernet Ports Left LED Indicator Right LED Indicator Isolation from internal ... Full duplex IEEE 802.3x flow control Half-duplex back pressure flow control See Table 3-5. 3: Installation of 4-port, 8-port, 16-port RS232 Serial Ports DTE via RJ45 connectors Selectable from adjacent port Reset-to 921600 bps Characters: 7 or 8 data bits Stop... IEC60320 C14 receptacle with no power switch 100-240 VAC, 50/60 HZ, 0.4M EDS-MD User Guide 26
... 2 of USB-A Host, USB 2.0, Full Speed only 0.5 A 1.5 KVAC 1.5 KVAC Options of EDS-MD4/8/16 Device Servers Technical Specification Category NETWORK INTERFACE Ethernet Ports Left LED Indicator Right LED Indicator Isolation from internal ... Full duplex IEEE 802.3x flow control Half-duplex back pressure flow control See Table 3-5. 3: Installation of 4-port, 8-port, 16-port RS232 Serial Ports DTE via RJ45 connectors Selectable from adjacent port Reset-to 921600 bps Characters: 7 or 8 data bits Stop... IEC60320 C14 receptacle with no power switch 100-240 VAC, 50/60 HZ, 0.4M EDS-MD User Guide 26
EDS-MD - User Guide
Page 27
See Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts (on the wall. If using AC power, do not use . 3. Power up the serial devices. Attach a CAT 5 serial cable between the EDS-MD Ethernet port and your serial device. Connect an Ethernet cable between the EDS-MD and your Ethernet network. 4. EDS-MD User Guide 27 Power off...
See Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts (on the wall. If using AC power, do not use . 3. Power up the serial devices. Attach a CAT 5 serial cable between the EDS-MD Ethernet port and your serial device. Connect an Ethernet cable between the EDS-MD and your Ethernet network. 4. EDS-MD User Guide 27 Power off...
EDS-MD - User Guide
Page 28
... Settings Name DHCP Device Name Description Name identifying the EDS-MD. Select the EDS-MD4/8/16 unit by Lantronix that discovers, configures, upgrades and manages Lantronix Device Servers. The current EDS-MD4/8/16 configuration appears. On the right page, click the Device...wizard prompts. (If prompted to the folder icon. Accessing EDS-MD Using DeviceInstaller Note: Make note of available Lantronix EDS-MD4/8/16 devices appears. 5. Click Start -> All Programs -> Lantronix -> DeviceInstaller -> DeviceInstaller. 3. EDS-MD User Guide 28 Device Detail Summary Note: The settings are...
... Settings Name DHCP Device Name Description Name identifying the EDS-MD. Select the EDS-MD4/8/16 unit by Lantronix that discovers, configures, upgrades and manages Lantronix Device Servers. The current EDS-MD4/8/16 configuration appears. On the right page, click the Device...wizard prompts. (If prompted to the folder icon. Accessing EDS-MD Using DeviceInstaller Note: Make note of available Lantronix EDS-MD4/8/16 devices appears. 5. Click Start -> All Programs -> Lantronix -> DeviceInstaller -> DeviceInstaller. 3. EDS-MD User Guide 28 Device Detail Summary Note: The settings are...
EDS-MD - User Guide
Page 30
...3. All changes take place the next time the web page is "PASS." Open a standard web browser. Lantronix supports the latest version of the EDS-MD4/8/16 in nonvolatile memory and is available on the DeviceInstaller window. The Device Status web page displays configuration, network ...EDS-MD4, EDS-MD8 and EDS-MD16 using DeviceInstaller (see the EDS-MD Quick Start Guide) or automatically by selecting the Web Configuration tab on any web page. The unit's configuration is stored in the address bar. The IP address may have been assigned manually using Web Manager, the Lantronix...
...3. All changes take place the next time the web page is "PASS." Open a standard web browser. Lantronix supports the latest version of the EDS-MD4/8/16 in nonvolatile memory and is available on the DeviceInstaller window. The Device Status web page displays configuration, network ...EDS-MD4, EDS-MD8 and EDS-MD16 using DeviceInstaller (see the EDS-MD Quick Start Guide) or automatically by selecting the Web Configuration tab on any web page. The unit's configuration is stored in the address bar. The IP address may have been assigned manually using Web Manager, the Lantronix...
EDS-MD - User Guide
Page 33
...settings for the query port. 69 RSS Lets you change current Really Simple Syndication (RSS) settings. 56 SSH Lets you must reboot the EDS-MD4/8/16 for the File 53 Transfer Protocol (FTP) server. Some pages are read-only, while others let you reboot the unit, this operation... every web page. Shows statistics and lets you browse the file system to the Lantronix home page. A menu bar on the network. 50 HTTP Shows HyperText Transfer Protocol (HTTP) statistics and lets you upload an existing certificate or create a new self-signed certificate. 61 EDS-MD User Guide 33
...settings for the query port. 69 RSS Lets you change current Really Simple Syndication (RSS) settings. 56 SSH Lets you must reboot the EDS-MD4/8/16 for the File 53 Transfer Protocol (FTP) server. Some pages are read-only, while others let you reboot the unit, this operation... every web page. Shows statistics and lets you browse the file system to the Lantronix home page. A menu bar on the network. 50 HTTP Shows HyperText Transfer Protocol (HTTP) statistics and lets you upload an existing certificate or create a new self-signed certificate. 61 EDS-MD User Guide 33