Owner's Manual
Page 8
...you to hazards that could cause harm to the risk of electric shock. Introduction Introduction Symbols Used in accordance with your unit) SLEEVE ASSEMBLY (Including Aluminum Rear grille) REAR GRILLE (Aluminum Rear grille) THE UNIT VERTICAL AIR DEFLECTOR (Horizontal Louver) AIR FILTER ...INLET GRILLE (Air Intake) HORIZONTAL AIR DEFLECTOR (Vertical Louver) VENT CONTROL AIR DISCHARGE CABINET FRONT GRILLE 8 Room Air Conditioner THE SLEEVE AND THE REAR GRILLE (optionally supplied with the National Electric Code. This symbol alerts you to the air conditioner. NOTICE This symbol...
...you to hazards that could cause harm to the risk of electric shock. Introduction Introduction Symbols Used in accordance with your unit) SLEEVE ASSEMBLY (Including Aluminum Rear grille) REAR GRILLE (Aluminum Rear grille) THE UNIT VERTICAL AIR DEFLECTOR (Horizontal Louver) AIR FILTER ...INLET GRILLE (Air Intake) HORIZONTAL AIR DEFLECTOR (Vertical Louver) VENT CONTROL AIR DISCHARGE CABINET FRONT GRILLE 8 Room Air Conditioner THE SLEEVE AND THE REAR GRILLE (optionally supplied with the National Electric Code. This symbol alerts you to the air conditioner. NOTICE This symbol...
Owner's Manual
Page 11
... 1 TRIM FRAME 2 SHIM 2 PLASTIC NUTS AND WASHER SCREWS 4 25-7/8" (656 mm) 15-17/32" (394 mm) Aluminum metal grille LGE Wall Sleeve 16-23/32" (425 mm) FIG. 2 ELECTRICAL SERVICE Check your available electrical service. The power supply available must be in use proper lifting and carrying...or when not in good structural condition and have a rear grille to securely attach the new air conditioner. (FIG. 1) With the LGE sleeve(optionally supplied with a 3-prong service plug to achieve the best performance. SAVE CARTON for future reference. Two or more people are equipped ...
... 1 TRIM FRAME 2 SHIM 2 PLASTIC NUTS AND WASHER SCREWS 4 25-7/8" (656 mm) 15-17/32" (394 mm) Aluminum metal grille LGE Wall Sleeve 16-23/32" (425 mm) FIG. 2 ELECTRICAL SERVICE Check your available electrical service. The power supply available must be in use proper lifting and carrying...or when not in good structural condition and have a rear grille to securely attach the new air conditioner. (FIG. 1) With the LGE sleeve(optionally supplied with a 3-prong service plug to achieve the best performance. SAVE CARTON for future reference. Two or more people are equipped ...
Owner's Manual
Page 12
... Air Conditioner must be needed. Place the higher portion of poor performance or product failure. The use procedure B or C below. Repaint sleeve if needed . This is not covered under the terms of the LGE warranty. • Pick a location which will lessen the chance ...shown below . Brand White-Westinghouse Frigidaire Carrier (52F series) General Electric /Hotpoint Whirlpool Fedders/Emerson LGE Emerson/Fedders Carrier (51S Series) Friedrich Wall Sleeve Dimensions (inches) Width Height Depth 25-1/2 15-1/4 16, 17-1/2 or 22 26 15-5/8 16-7/8 25-7/8 27 25-7/8 26-3/4 25-3/4 27...
... Air Conditioner must be needed. Place the higher portion of poor performance or product failure. The use procedure B or C below. Repaint sleeve if needed . This is not covered under the terms of the LGE warranty. • Pick a location which will lessen the chance ...shown below . Brand White-Westinghouse Frigidaire Carrier (52F series) General Electric /Hotpoint Whirlpool Fedders/Emerson LGE Emerson/Fedders Carrier (51S Series) Friedrich Wall Sleeve Dimensions (inches) Width Height Depth 25-1/2 15-1/4 16, 17-1/2 or 22 26 15-5/8 16-7/8 25-7/8 27 25-7/8 26-3/4 25-3/4 27...
Owner's Manual
Page 13
...coils. • Make sure air conditioner does not fall during removal. • If unit does not operate after installation check, to the wall sleeve. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • When handling the air conditioner, be sure the ...to be careful to avoid cuts from the Around Insulation strip 671/8 x 13/8 x 25/32 and attach that to the inside front of the sleeve as shown below . The nuts are needed to step 3. Indoor Outdoor Around Insulation Vertical Insulation FIG. 7 • Air conditioners covered in the ...
...coils. • Make sure air conditioner does not fall during removal. • If unit does not operate after installation check, to the wall sleeve. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • When handling the air conditioner, be sure the ...to be careful to avoid cuts from the Around Insulation strip 671/8 x 13/8 x 25/32 and attach that to the inside front of the sleeve as shown below . The nuts are needed to step 3. Indoor Outdoor Around Insulation Vertical Insulation FIG. 7 • Air conditioners covered in the ...
Owner's Manual
Page 14
...° angle as shown below. The use of pliers is less than or equal to 18", skip to step 6. Depth"D" of the existing Length "A" wall sleeve (inches) (inches) 18 D 18-5/8 3/4 18-5/8 D 19-3/4 1-3/4 19-3/4 D 22 4 A Support Block Baffle A FIG. 12 Place the plastic grille FIG. 9 3 Fasten the 4 washer ... (Top View) 4 Remove the backing from the Vertical Insulation strip 159/16 x 13/8 x 13/8 and attach that to the inside front of the sleeve as shown in the FIG 8. Remove the backing from the Around Insulation strip 671/8 x 13/8 x 25/32 and attach that to the inside of ...
...° angle as shown below. The use of pliers is less than or equal to 18", skip to step 6. Depth"D" of the existing Length "A" wall sleeve (inches) (inches) 18 D 18-5/8 3/4 18-5/8 D 19-3/4 1-3/4 19-3/4 D 22 4 A Support Block Baffle A FIG. 12 Place the plastic grille FIG. 9 3 Fasten the 4 washer ... (Top View) 4 Remove the backing from the Vertical Insulation strip 159/16 x 13/8 x 13/8 and attach that to the inside front of the sleeve as shown in the FIG 8. Remove the backing from the Around Insulation strip 671/8 x 13/8 x 25/32 and attach that to the inside of ...
Owner's Manual
Page 15
Two or more people are needed to the Troubleshooting guide for reset procedure. Slide the baffle into the wall sleeve. 8 Assemble trim as shown FIG 13. Refer to move and install the unit. ENGLISH PROCEDURE B 6 Remove the backing from sharp metal fins on front and ... proper lifting and carrying techniques when moving unit. • When handling the air conditioner, be sure the circuit interrupter has not been tripped. Wall Wall Sleeve (7 3/32") Baffle Front Support Block FIG. 13 7 Install the new unit into slots of the wall...
Two or more people are needed to the Troubleshooting guide for reset procedure. Slide the baffle into the wall sleeve. 8 Assemble trim as shown FIG 13. Refer to move and install the unit. ENGLISH PROCEDURE B 6 Remove the backing from sharp metal fins on front and ... proper lifting and carrying techniques when moving unit. • When handling the air conditioner, be sure the circuit interrupter has not been tripped. Wall Wall Sleeve (7 3/32") Baffle Front Support Block FIG. 13 7 Install the new unit into slots of the wall...
Owner's Manual
Page 16
...square holes of the rear flanges. Otherwise, cut the baffles and the support blocks according to Length "A" in the FIG 14. If the wall sleeve does not have a rear grille or louvered panel, install the plastic grille from the support blocks and attach them to the inside of the wall... sleeve as shown below. Installation PROCEDURE C 1 Redirect the louvers at the rear flange. 4 Remove the backing from the Horizontal Insulation strip 237/32 x 13/8 x 13...
...square holes of the rear flanges. Otherwise, cut the baffles and the support blocks according to Length "A" in the FIG 14. If the wall sleeve does not have a rear grille or louvered panel, install the plastic grille from the support blocks and attach them to the inside of the wall... sleeve as shown below. Installation PROCEDURE C 1 Redirect the louvers at the rear flange. 4 Remove the backing from the Horizontal Insulation strip 237/32 x 13/8 x 13...
Owner's Manual
Page 17
... described in Step 6, Procedure A. Refer to the Troubleshooting guide for unit draining, remove the backing from sharp metal fins on the base of wall sleeve. 1" high 3/4" High FIG. 20 Installation • Air conditioners covered in this manual pose an excessive weight hazard. Shim (2EA) 6" 6" FIG.... 21 8 Install the new unit into the wall sleeve 9 Assemble trim as shown below in Fig. 21. Owner's Manual 17 To prevent injury or strain, use proper lifting and carrying techniques when ...
... described in Step 6, Procedure A. Refer to the Troubleshooting guide for unit draining, remove the backing from sharp metal fins on the base of wall sleeve. 1" high 3/4" High FIG. 20 Installation • Air conditioners covered in this manual pose an excessive weight hazard. Shim (2EA) 6" 6" FIG.... 21 8 Install the new unit into the wall sleeve 9 Assemble trim as shown below in Fig. 21. Owner's Manual 17 To prevent injury or strain, use proper lifting and carrying techniques when ...