Owner's Manual
Page 2
...you review our chart of each unit. If you may not need to call for use and maintain your air conditioner properly. Just a little preventive care on your air conditioner. Hardware Installation 5. A CAUTION • Contact the authorized service technician for repair or maintenance of this ... do notplay with the air conditioner. Common Issues ____jor Your Records Write the modeland serialnumbers here: Model # Serial # You can save you will find them on a label on how to common problems in the chart of troubleshooting tips. Window-Type Air Conditioner Owner's Manual TABLE OF...
...you review our chart of each unit. If you may not need to call for use and maintain your air conditioner properly. Just a little preventive care on your air conditioner. Hardware Installation 5. A CAUTION • Contact the authorized service technician for repair or maintenance of this ... do notplay with the air conditioner. Common Issues ____jor Your Records Write the modeland serialnumbers here: Model # Serial # You can save you will find them on a label on how to common problems in the chart of troubleshooting tips. Window-Type Air Conditioner Owner's Manual TABLE OF...
Owner's Manual
Page 4
... with windows opened may cause wetting of indoor and soaking of household furniture. ® Do not place obstacles around the absorption inlet or output. • Doing so may cause failure of gas • Doing so may otherwise occur. ® Do not use . • If the previous air conditioner damaged ... the power is off d the cord is not pinched. • Treating the power cord carelessly poses a danger of property. If the liquid from air conditioner. • It contains contaminants that the cord is unplugged. • Since the fan rotates at high speed during operation, it out. •...
... with windows opened may cause wetting of indoor and soaking of household furniture. ® Do not place obstacles around the absorption inlet or output. • Doing so may cause failure of gas • Doing so may otherwise occur. ® Do not use . • If the previous air conditioner damaged ... the power is off d the cord is not pinched. • Treating the power cord carelessly poses a danger of property. If the liquid from air conditioner. • It contains contaminants that the cord is unplugged. • Since the fan rotates at high speed during operation, it out. •...
Owner's Manual
Page 11
... vertical opening of 12" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of the air conditioner. Sash Window Offset Sill Exterior How to 393/8"(1000mm) 12 (305mm) min. This will greatly reduce the cooling efficiency of outside... air will force condensed water to flow to the window stool. a===0 ■ 26"(660mm) to Install th Unit ip To prevent vibration and noise, make sure the unit is installed securely ...
... vertical opening of 12" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of the air conditioner. Sash Window Offset Sill Exterior How to 393/8"(1000mm) 12 (305mm) min. This will greatly reduce the cooling efficiency of outside... air will force condensed water to flow to the window stool. a===0 ■ 26"(660mm) to Install th Unit ip To prevent vibration and noise, make sure the unit is installed securely ...
Owner's Manual
Page 12
... for installation must be blown from the air conditioner in FIG. 1. If air conditioner is very important. How to Install 1.) Cut the FOAM STRIP (ITEM G) to blow the cold air into the area you to fit the underside of the window sash. Good installation with pencil on Page...ITEM G) FIG. 1 ?) Mark center line with special attention to the proper position of the air conditioner. Windows used for possible shipping damage. When cooling more than one room, installation location is blocked by a storm window frame, see Step 7 and 8 on the center of the inner sill, as shown in a...
... for installation must be blown from the air conditioner in FIG. 1. If air conditioner is very important. How to Install 1.) Cut the FOAM STRIP (ITEM G) to blow the cold air into the area you to fit the underside of the window sash. Good installation with pencil on Page...ITEM G) FIG. 1 ?) Mark center line with special attention to the proper position of the air conditioner. Windows used for possible shipping damage. When cooling more than one room, installation location is blocked by a storm window frame, see Step 7 and 8 on the center of the inner sill, as shown in a...
Owner's Manual
Page 13
...OF SUPPORT BRACKET (ITEM A) SCREW (ITEM D) INNER WINDOW SILL 1125.4mm) CENTER LINE OF WINDOW ADJUSTMENT SLOT LEVELING BOLT (ITEMB or C) FIG. 3 4) INSTALL THE AIR CONDITIONER IN THE WINDOW • Carefully lift the air conditioner and slide it into the open window. Personal injury or property damage may result in personal...careful not to securely install support bracket may result if unit falls from window if window sash is raised after unit is inserted in the pocket under base fan, and that the air conditioner will feel unit drop securely in top channel of support bracket. Hold...
...OF SUPPORT BRACKET (ITEM A) SCREW (ITEM D) INNER WINDOW SILL 1125.4mm) CENTER LINE OF WINDOW ADJUSTMENT SLOT LEVELING BOLT (ITEMB or C) FIG. 3 4) INSTALL THE AIR CONDITIONER IN THE WINDOW • Carefully lift the air conditioner and slide it into the open window. Personal injury or property damage may result in personal...careful not to securely install support bracket may result if unit falls from window if window sash is raised after unit is inserted in the pocket under base fan, and that the air conditioner will feel unit drop securely in top channel of support bracket. Hold...
Owner's Manual
Page 14
... room, as shown in FIG.7. • Install the L bracket to prevent window from being raised which may result in unit falling. 7) IF AIR CONDITIONER IS BLOCKED BY STORM WINDOW FRAME • If storm window presents interference, fasten a 2"(51mm) wide wood strip to the window width. See FIG. 8. Top of wood strip should be thick enough to...
... room, as shown in FIG.7. • Install the L bracket to prevent window from being raised which may result in unit falling. 7) IF AIR CONDITIONER IS BLOCKED BY STORM WINDOW FRAME • If storm window presents interference, fasten a 2"(51mm) wide wood strip to the window width. See FIG. 8. Top of wood strip should be thick enough to...
Owner's Manual
Page 15
...the inner sill. SASH WINDOW - WINDOW FRAME -1 WOOD STRIP 19/32"(15mm) INNER SILL OUTER SILL FIG. 9 REMOVAL FROM WINDOW • Turn off and unplug the air conditioner. • Unscrew the side screws that you the sash. • Lift the air conditioner from the window and remove the foam strip... from between the windows. • Remove the support bracket from sharp ...
...the inner sill. SASH WINDOW - WINDOW FRAME -1 WOOD STRIP 19/32"(15mm) INNER SILL OUTER SILL FIG. 9 REMOVAL FROM WINDOW • Turn off and unplug the air conditioner. • Unscrew the side screws that you the sash. • Lift the air conditioner from the window and remove the foam strip... from between the windows. • Remove the support bracket from sharp ...
Specification
Page 1
On/Off ENJOY A COOL VIEW The LG 6,000 BTU Low Profile Window Air Conditioner is easy to use installation kit so you can have the unit power off when you leave and turn on before you to cool down ... The slim and attractive low-profile design frees up you air conditioner with our easy-to-use and allows you return, automatically. This window unit comes with ease. Featuring a programmable 12 hour timer, you can set up more of your home. AIR CONDITIONER LP6011ER Low Profile Air Conditioner HIGHLIGHTS Low Profile Design Easy-to-Use Installation Kit Electronic...
On/Off ENJOY A COOL VIEW The LG 6,000 BTU Low Profile Window Air Conditioner is easy to use installation kit so you can have the unit power off when you leave and turn on before you to cool down ... The slim and attractive low-profile design frees up you air conditioner with our easy-to-use and allows you return, automatically. This window unit comes with ease. Featuring a programmable 12 hour timer, you can set up more of your home. AIR CONDITIONER LP6011ER Low Profile Air Conditioner HIGHLIGHTS Low Profile Design Easy-to-Use Installation Kit Electronic...