Owner's Manual (English)
Page 1
IMPORTANT Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner. This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use. It contains valuable information about your air conditioner. ENGLISH ESPAÑOL FRANÇAIS http://www.lgservice.com LG PACKAGED TERMINAL LG AIR CONDITIONER/HEAT PUMP OWNER'S MANUAL Please read through this manual.
IMPORTANT Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner. This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use. It contains valuable information about your air conditioner. ENGLISH ESPAÑOL FRANÇAIS http://www.lgservice.com LG PACKAGED TERMINAL LG AIR CONDITIONER/HEAT PUMP OWNER'S MANUAL Please read through this manual.
Owner's Manual (English)
Page 2
...our chart of Troubleshooting Tips first, you may not need it to common problems in the chart of troubleshooting tips. READ THIS MANUAL Inside you will find many helpful hints on the side of each unit. You'll find many answers to prove date of ... Name Date Purchased I Staple your receipt to call for use and maintain your air conditioner properly. Packaged Terminal Air Conditioner/Heat Pump Owner's Manual TABLE OF CONTENTS Safety Precautions 3 Before Operation 7 Introduction 8 Electrical Safety 9 Installation 11 Control Locations 13 Maintenance and Service 21 FOR YOUR ...
...our chart of Troubleshooting Tips first, you may not need it to common problems in the chart of troubleshooting tips. READ THIS MANUAL Inside you will find many helpful hints on the side of each unit. You'll find many answers to prove date of ... Name Date Purchased I Staple your receipt to call for use and maintain your air conditioner properly. Packaged Terminal Air Conditioner/Heat Pump Owner's Manual TABLE OF CONTENTS Safety Precautions 3 Before Operation 7 Introduction 8 Electrical Safety 9 Installation 11 Control Locations 13 Maintenance and Service 21 FOR YOUR ...
Owner's Manual (English)
Page 3
CAUTION This symbol indicates the possibility of death or serious injury. Don't do this manual are as gasoline, benzene, thinner, etc. • It may cause explosion or fire. WARNING I Installation Don't use the power cord near flammable ... outlet. Do not use a power cord, a plug, or a loose socket which is classified by the following instructions must be followed. Gasolin Owner's Manual 3 due to follow the instruction. I Incorrect operation due to ignoring instruction will cause electric shock or fire shock. ENGLISH Safety Precautions Safety Precautions To prevent...
CAUTION This symbol indicates the possibility of death or serious injury. Don't do this manual are as gasoline, benzene, thinner, etc. • It may cause explosion or fire. WARNING I Installation Don't use the power cord near flammable ... outlet. Do not use a power cord, a plug, or a loose socket which is classified by the following instructions must be followed. Gasolin Owner's Manual 3 due to follow the instruction. I Incorrect operation due to ignoring instruction will cause electric shock or fire shock. ENGLISH Safety Precautions Safety Precautions To prevent...
Owner's Manual (English)
Page 5
...; Otherwise, it out. • It may cause vibration or water leakage. due to -side when installing. • It may cause electric shock and damage. Owner's Manual 5 Do not operate with wet hands or in damp environment. • It will cause electric shock or fire • It will cause electric shock or...
...; Otherwise, it out. • It may cause vibration or water leakage. due to -side when installing. • It may cause electric shock and damage. Owner's Manual 5 Do not operate with wet hands or in damp environment. • It will cause electric shock or fire • It will cause electric shock or...
Owner's Manual (English)
Page 7
... objects). When cleaning the unit, first make sure that the power and breaker are turned off. Service For repair and maintenance, contact your health. Owner's Manual 7 Plug in the draft. 2. Do not start/stop operation by plugging/unplugging the power cord. 6. If the cord/plug is damaged, replace it -yourself project...
... objects). When cleaning the unit, first make sure that the power and breaker are turned off. Service For repair and maintenance, contact your health. Owner's Manual 7 Plug in the draft. 2. Do not start/stop operation by plugging/unplugging the power cord. 6. If the cord/plug is damaged, replace it -yourself project...
Owner's Manual (English)
Page 8
Features This appliance should be installed in this Manual This symbol alerts you to hazards that could cause harm to the risk of electric shock. This symbol alerts you to the air conditioner. Introduction ... (Including Aluminum Rear Grille) REAR GRILLE (Aluminum Rear Grille) AIR FILTER INDOOR INLET GRILLE (Air Intake) 8 Room Air Conditioner EXPANDED METAL GRILLE (For Superior Performance) LG PTAC and PTHP test condition is recommended with the National Electric Code. NOTICE This symbol indicates special notes.
Features This appliance should be installed in this Manual This symbol alerts you to hazards that could cause harm to the risk of electric shock. This symbol alerts you to the air conditioner. Introduction ... (Including Aluminum Rear Grille) REAR GRILLE (Aluminum Rear Grille) AIR FILTER INDOOR INLET GRILLE (Air Intake) 8 Room Air Conditioner EXPANDED METAL GRILLE (For Superior Performance) LG PTAC and PTHP test condition is recommended with the National Electric Code. NOTICE This symbol indicates special notes.
Owner's Manual (English)
Page 9
... lead, known to cause cancer, birth defects, or other reproductive harm. Do not use this product in accordance with local electrical codes and regulations. Owner's Manual 9 Use 20 AMP. If this cord are not grounded. Circuit Breaker) Standard 208/230V, 3-wire grounding receptacle rated 30A Use 30 AMP. Avoid shock hazard...
... lead, known to cause cancer, birth defects, or other reproductive harm. Do not use this product in accordance with local electrical codes and regulations. Owner's Manual 9 Use 20 AMP. If this cord are not grounded. Circuit Breaker) Standard 208/230V, 3-wire grounding receptacle rated 30A Use 30 AMP. Avoid shock hazard...
Owner's Manual (English)
Page 11
... cuts. • If the unit is to be attached. The insulation strip is optional.) 280 mm (11") Front Insulation Strip Sleeve Rear Owner's Manual 11 Refer to lift. Use 2 people to the diagram below. Dimension of a plastic rear grille. (This is provided with putty. INSULATION COOLED AIR...interfere with heat radiation and exhaust air flow. 1066 mm (42") • Before installation, Check the insulation on the inner side of the LG PTAC, an insulation strip must be installed close to the seaside, it needs additional treatment on the heat exchanger. • When lifting the ...
... cuts. • If the unit is to be attached. The insulation strip is optional.) 280 mm (11") Front Insulation Strip Sleeve Rear Owner's Manual 11 Refer to lift. Use 2 people to the diagram below. Dimension of a plastic rear grille. (This is provided with putty. INSULATION COOLED AIR...interfere with heat radiation and exhaust air flow. 1066 mm (42") • Before installation, Check the insulation on the inner side of the LG PTAC, an insulation strip must be installed close to the seaside, it needs additional treatment on the heat exchanger. • When lifting the ...
Owner's Manual (English)
Page 13
Control Locations Manual Controls Control Locations ENGLISH TEMPERATURE CONTROL Set the Thermostat control to the desired temperature mark 5 (the mid-point is harmless. LOW FAN Low speed fan .... Note: A slight heat odor may come from the unit when first switching to HEAT after a reasonable time, adjust the control to the OPEN position. Owner's Manual 13 LOW HEAT Heating with the high speed fan operation. • VENTILATION The ventilation lever is located to maintain the best cooling conditions. The damper...
Control Locations Manual Controls Control Locations ENGLISH TEMPERATURE CONTROL Set the Thermostat control to the desired temperature mark 5 (the mid-point is harmless. LOW FAN Low speed fan .... Note: A slight heat odor may come from the unit when first switching to HEAT after a reasonable time, adjust the control to the OPEN position. Owner's Manual 13 LOW HEAT Heating with the high speed fan operation. • VENTILATION The ventilation lever is located to maintain the best cooling conditions. The damper...
Owner's Manual (English)
Page 15
...to be used by flashing number of the problems defined below for which is happening & by referring the user's manual the customer can be very clear about the unit. Owner's Manual 15 USE: If the customer has to register a complaint to indicate the errors. Here are the mentioned which... Coil Thermistor Error (PTHP Only) CH 05 Mode Error CH 06 Set point Error CH 07 Bad Thermistor Wiring CH 09 Pressure Switch Error • Manual Controls ON OFF Fault Codes 1 2 3 4 5 6 7 LED Flash Rate Normal No power / failed board Indoor Air Thermistor Error Indoor Coil Thermistor Error ...
...to be used by flashing number of the problems defined below for which is happening & by referring the user's manual the customer can be very clear about the unit. Owner's Manual 15 USE: If the customer has to register a complaint to indicate the errors. Here are the mentioned which... Coil Thermistor Error (PTHP Only) CH 05 Mode Error CH 06 Set point Error CH 07 Bad Thermistor Wiring CH 09 Pressure Switch Error • Manual Controls ON OFF Fault Codes 1 2 3 4 5 6 7 LED Flash Rate Normal No power / failed board Indoor Air Thermistor Error Indoor Coil Thermistor Error ...
Owner's Manual (English)
Page 17
...;C) 82°F (27.8°C) 80°F (26.7°C) 78°F (25.5°C) 76°F (24.4°C) 74°F (23.3°C) 72°F (22.2°C) Owner's Manual 17 To remove the front grille, pull out the bottom of control box. The authorized service man has to check switches and ensure the switches...
...;C) 82°F (27.8°C) 80°F (26.7°C) 78°F (25.5°C) 76°F (24.4°C) 74°F (23.3°C) 72°F (22.2°C) Owner's Manual 17 To remove the front grille, pull out the bottom of control box. The authorized service man has to check switches and ensure the switches...
Owner's Manual (English)
Page 18
... by knobs are connected, the unit will be turned ON or OFF with a switch located at cycle fan to provide continuous fan operation in this manual for heat pump and straight cool units with the heater. • FRONT DESK CONTROL When the pair wire is connected to the connector FD2 and...
... by knobs are connected, the unit will be turned ON or OFF with a switch located at cycle fan to provide continuous fan operation in this manual for heat pump and straight cool units with the heater. • FRONT DESK CONTROL When the pair wire is connected to the connector FD2 and...
Owner's Manual (English)
Page 19
... or with electric heat, respectively. When you install the digital / electronic thermostat, you must set at the Front Desk Control panel. Owner's Manual 19 ENGLISH Control Locations • REMOTE/LOCAL CONTROL When remote/local switch #1 is OFF, the unit can be controlled by the control of ... by knobs are connected, the unit will be turned ON or OFF with a switch located at continuous fan to provide continuous fan operation in this manual for the Remote Wall Thermostat. 24 Volt-N 24 Volt-L Compressor Heater Reversing Valve High Fan Low Fan LO LI GL GH O W Y R C...
... or with electric heat, respectively. When you install the digital / electronic thermostat, you must set at the Front Desk Control panel. Owner's Manual 19 ENGLISH Control Locations • REMOTE/LOCAL CONTROL When remote/local switch #1 is OFF, the unit can be controlled by the control of ... by knobs are connected, the unit will be turned ON or OFF with a switch located at continuous fan to provide continuous fan operation in this manual for the Remote Wall Thermostat. 24 Volt-N 24 Volt-L Compressor Heater Reversing Valve High Fan Low Fan LO LI GL GH O W Y R C...
Owner's Manual (English)
Page 21
... screws at least twice a month to the wall sleeve with vent door closed, the vent filter does not need to Figure B. 5. Vent Filter Removal Owner's Manual 21
... screws at least twice a month to the wall sleeve with vent door closed, the vent filter does not need to Figure B. 5. Vent Filter Removal Owner's Manual 21
Owner's Manual (English)
Page 23
... I Rotary switch I Wire disconnected or connection loose I Capacitor (Discharge capacitor before testing) I Revolves on this page. Refer to rotary switch. Refer to the base. Owner's Manual 23 Replace cord if circuit is high. Replace if shorted, open . • Check switch continuity. Realign assembly. • Units using slinger ring condenser fans must...
... I Rotary switch I Wire disconnected or connection loose I Capacitor (Discharge capacitor before testing) I Revolves on this page. Refer to rotary switch. Refer to the base. Owner's Manual 23 Replace cord if circuit is high. Replace if shorted, open . • Check switch continuity. Realign assembly. • Units using slinger ring condenser fans must...
Owner's Manual (English)
Page 25
.... Replace if required. • Remove the cabinet. ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING 208/230 V 265 V MINIMUM 187 V 239 V MAXIMUM 253 V 292 V Owner's Manual 25 Replace if open. (If the compressor temperature is properly sized for a restriction. • If restricted, clean or replace. • Close if open. • Determine...
.... Replace if required. • Remove the cabinet. ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING 208/230 V 265 V MINIMUM 187 V 239 V MAXIMUM 253 V 292 V Owner's Manual 25 Replace if open. (If the compressor temperature is properly sized for a restriction. • If restricted, clean or replace. • Close if open. • Determine...
Owner's Manual (English)
Page 27
...Terminal which fails due to the original purchaser of the original part(s). Use of repair or replacement under normal use and care manual, such as replacing filters, cleaning of the original warranty period. Products with this limited four-year parts warranty, you . ...condenser, evaporator and all labor and on -site service to a defect in materials or workmanship under these excluded circumstances shall be borne by LG. 9. Damages resulting from accident, misuse, abuse, or improper installation, repair, or maintenance. This warranty gives you, the original purchaser, ...
...Terminal which fails due to the original purchaser of the original part(s). Use of repair or replacement under normal use and care manual, such as replacing filters, cleaning of the original warranty period. Products with this limited four-year parts warranty, you . ...condenser, evaporator and all labor and on -site service to a defect in materials or workmanship under these excluded circumstances shall be borne by LG. 9. Damages resulting from accident, misuse, abuse, or improper installation, repair, or maintenance. This warranty gives you, the original purchaser, ...
Owner's Manual (Español)
Page 1
IMPORTANT Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner. It contains valuable information about your air conditioner. This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use. ENGLISH ESPAÑOL FRANÇAIS http://www.lgservice.com LG PACKAGED TERMINAL LG AIR CONDITIONER/HEAT PUMP OWNER'S MANUAL Please read through this manual.
IMPORTANT Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner. It contains valuable information about your air conditioner. This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use. ENGLISH ESPAÑOL FRANÇAIS http://www.lgservice.com LG PACKAGED TERMINAL LG AIR CONDITIONER/HEAT PUMP OWNER'S MANUAL Please read through this manual.
Owner's Manual (Español)
Page 27
...plumbing, or correction of God. 5. No other rights that fail due to a defect in the installation instructions and use and care manual, such as replacing filters, cleaning of original purchase, LGE will meet intended fit and function of repair or replacement under normal use of...to the original purchaser of the sealed refrigerating system (the compressor, condenser, evaporator and all labor and on -site service costs. LG ELECTRONICS, INC. LG Packaged Terminal Air Conditioner Limited Warranty - WARRANTY PERIOD: For The Period Of: One Year From the date of the original purchase...
...plumbing, or correction of God. 5. No other rights that fail due to a defect in the installation instructions and use and care manual, such as replacing filters, cleaning of original purchase, LGE will meet intended fit and function of repair or replacement under normal use of...to the original purchaser of the sealed refrigerating system (the compressor, condenser, evaporator and all labor and on -site service costs. LG ELECTRONICS, INC. LG Packaged Terminal Air Conditioner Limited Warranty - WARRANTY PERIOD: For The Period Of: One Year From the date of the original purchase...