Service Manual
Page 1
MODELS: LDC24370ST /00 LDC24370SW /00 LBC24360ST / 00 LBC24360SW /00 REFRIGERATOR SERVICE MANUAL CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
MODELS: LDC24370ST /00 LDC24370SW /00 LBC24360ST / 00 LBC24360SW /00 REFRIGERATOR SERVICE MANUAL CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
Service Manual
Page 2
... in the freezer with wet hands. COMPRESSOR ELECTRICAL 12 4-1 Compressor Freezer Drawer model 12 4-2 Compressor Freezer Swing model 13 4-3 PTC-Starter 13 4-4 OLP (Overload Protector 14 5. COMPONENT TESTING INFORMATION 39 11. To prevent electric shock, unplug before servicing your refrigerator. 1. Service on the refrigerator should be performed by a qualified technician. DISASSEMBLY 6 3-1 Removing and replacing...
... in the freezer with wet hands. COMPRESSOR ELECTRICAL 12 4-1 Compressor Freezer Drawer model 12 4-2 Compressor Freezer Swing model 13 4-3 PTC-Starter 13 4-4 OLP (Overload Protector 14 5. COMPONENT TESTING INFORMATION 39 11. To prevent electric shock, unplug before servicing your refrigerator. 1. Service on the refrigerator should be performed by a qualified technician. DISASSEMBLY 6 3-1 Removing and replacing...
Service Manual
Page 3
SPECIFICATIONS GENERAL FEATURES MODELS FREEZER REFRIGERATOR SPECIFICATIONS Color Dimensions (W*D*H) Net Weight Capacity Refrigerant Climate class Rated Rating Cooling System Temperature Control Defrosting System Insulation Compressor Evaporator Condenser Lubricanting ...Tray Vegetable Pantry Basket, Quantity Lamp Shelf Ice Maker Ice Tray & Bank Tray Drawer (F/U) Tray Drawer (F/C) Tray Drawer (F/L) LDC24370ST /00 LDC24370SW /00 LBC24360ST / 00 LBC24360SW /00 Stainless Steel Stainless Super White Stainless Steel (32 3/4 x 34 7/8 x 69 7/8)in 248.5 lb 24cuft R134a Temperate (N) ...
SPECIFICATIONS GENERAL FEATURES MODELS FREEZER REFRIGERATOR SPECIFICATIONS Color Dimensions (W*D*H) Net Weight Capacity Refrigerant Climate class Rated Rating Cooling System Temperature Control Defrosting System Insulation Compressor Evaporator Condenser Lubricanting ...Tray Vegetable Pantry Basket, Quantity Lamp Shelf Ice Maker Ice Tray & Bank Tray Drawer (F/U) Tray Drawer (F/C) Tray Drawer (F/L) LDC24370ST /00 LDC24370SW /00 LBC24360ST / 00 LBC24360SW /00 Stainless Steel Stainless Super White Stainless Steel (32 3/4 x 34 7/8 x 69 7/8)in 248.5 lb 24cuft R134a Temperate (N) ...
Service Manual
Page 8
If necessary, remove top shelf or shelves. 3-6-1 Refrigerator Compartment Lamp 1) Unplug refrigerator power cord from connector. 4) Replace the LED assembly. 3-8 MAIN PWB 1) Loosen 3 screws on the PWB cover. Unplug refrigerator power cord form outlet. 2. Grasp the cover Lamp,pull the cover downward. 2) Remove... the PWB cover 3) Disconnect wire harness and replace the main PWB in the reverse order of refrigerator light. 3-7 MULTI DUCT 1. 3-6 LAMP Unplug Refrigerator, or disconnect power at the circuit breaker. Disconnect the lead wire on the bottom position. 3) Remove the...
If necessary, remove top shelf or shelves. 3-6-1 Refrigerator Compartment Lamp 1) Unplug refrigerator power cord from connector. 4) Replace the LED assembly. 3-8 MAIN PWB 1) Loosen 3 screws on the PWB cover. Unplug refrigerator power cord form outlet. 2. Grasp the cover Lamp,pull the cover downward. 2) Remove... the PWB cover 3) Disconnect wire harness and replace the main PWB in the reverse order of refrigerator light. 3-7 MULTI DUCT 1. 3-6 LAMP Unplug Refrigerator, or disconnect power at the circuit breaker. Disconnect the lead wire on the bottom position. 3) Remove the...
Service Manual
Page 12
... from the evaporator of disassembly 12 The trip occurs if it is above the target value, decrease the target volt by part number and model number. Use only approved substitute parts. 4-1-3 REMOVE THE COVER PTC 4-1-4 Compressor protection logic Since linear Comp conducts linear reciprocating motion, we ... ON, the Trip occurs. - Lock Piston Trip If stroke is under 5mm even if the current is set in reverse order of the refrigerator and compresses this gas to protect compressor mechanical part and drive from any liquid. It then delivers the gas to the condenser. 4-1-2 Note...
... from the evaporator of disassembly 12 The trip occurs if it is above the target value, decrease the target volt by part number and model number. Use only approved substitute parts. 4-1-3 REMOVE THE COVER PTC 4-1-4 Compressor protection logic Since linear Comp conducts linear reciprocating motion, we ... ON, the Trip occurs. - Lock Piston Trip If stroke is under 5mm even if the current is set in reverse order of the refrigerator and compresses this gas to protect compressor mechanical part and drive from any liquid. It then delivers the gas to the condenser. 4-1-2 Note...
Service Manual
Page 13
...different electrical ratings. The PTC starter and OLP (overload protector) are used for starting device for the Motor. 4-3-2 Role of the refrigerator and compresses this gas to the Particular Compressor in damage to the compressor. The correct OLP must be properly attached to prevent damage... allowed to cool before the compressor can restart. (2) The PTC device generates heat during operation. Replace parts by part number and model number. These features are attached to restart until the PTC device has cooled. Since the compressor is manufactured to tolerances of the ...
...different electrical ratings. The PTC starter and OLP (overload protector) are used for starting device for the Motor. 4-3-2 Role of the refrigerator and compresses this gas to the Particular Compressor in damage to the compressor. The correct OLP must be properly attached to prevent damage... allowed to cool before the compressor can restart. (2) The PTC device generates heat during operation. Replace parts by part number and model number. These features are attached to restart until the PTC device has cooled. Since the compressor is manufactured to tolerances of the ...
Service Manual
Page 19
... CON7. Result & SVC Action 2 1-. For example, 23㏀ indicates -4°F. 19 Result 0Ω Short OFF Open Other Normal SVC Action Change the sensor Replace the refrigerator Check the Temp and resistance (Table-1) Temperature Result -22°F / -30°C 40.5 ~ 38.5 ㏀ -13°F / -25°C 30.5 ~ 28.5 ㏀ -4°F / -20°...
... CON7. Result & SVC Action 2 1-. For example, 23㏀ indicates -4°F. 19 Result 0Ω Short OFF Open Other Normal SVC Action Change the sensor Replace the refrigerator Check the Temp and resistance (Table-1) Temperature Result -22°F / -30°C 40.5 ~ 38.5 ㏀ -13°F / -25°C 30.5 ~ 28.5 ㏀ -4°F / -20°...
Service Manual
Page 20
... CON7. 2-. Check resistance between wires White to White. Result & SVC Action Result 0Ω Short OFF Open Other Normal SVC Action Change the sensor Replace the refrigerator Check the Temp and resistance (Table-2) Temperature Result 23°F / -5°C 38.5 ~ 36.5 ㏀ 32°F / 0°C 30.5 ~ 29.5 ㏀ 41°F /...;F / 15°C 16 ~15.5 ㏀ ※ The sensor is determined by the temperature. For example, 30㏀ indicates 32°F. 20 7-2 Refrigerator Sensor Error (rS E) No Checking flow 1 Check for loose connection in CON7. 2 1-.
... CON7. 2-. Check resistance between wires White to White. Result & SVC Action Result 0Ω Short OFF Open Other Normal SVC Action Change the sensor Replace the refrigerator Check the Temp and resistance (Table-2) Temperature Result 23°F / -5°C 38.5 ~ 36.5 ㏀ 32°F / 0°C 30.5 ~ 29.5 ㏀ 41°F /...;F / 15°C 16 ~15.5 ㏀ ※ The sensor is determined by the temperature. For example, 30㏀ indicates 32°F. 20 7-2 Refrigerator Sensor Error (rS E) No Checking flow 1 Check for loose connection in CON7. 2 1-.
Service Manual
Page 21
... Orange. 1-. Check resistance between wires Red to Orange. Result & SVC Action Result 0Ω Short OFF Open Other Normal SVC Action Change the sensor Replace the refrigerator Check the Temp and resistance (Table-1) Temperature Result -22°F / -30°C 40.5 ~ 38.5 ㏀ -13°F / -25°C 30.5 ~ 28.5 ㏀ -4°F / -20°...
... Orange. 1-. Check resistance between wires Red to Orange. Result & SVC Action Result 0Ω Short OFF Open Other Normal SVC Action Change the sensor Replace the refrigerator Check the Temp and resistance (Table-1) Temperature Result -22°F / -30°C 40.5 ~ 38.5 ㏀ -13°F / -25°C 30.5 ~ 28.5 ㏀ -4°F / -20°...
Service Manual
Page 22
Check the wires Orange to Brown. Result 0Ω Short OFF Open Other Normal SVC Action Change the sensor Replace the refrigerator Check the Temp and resistance (Table-3) 2.- Check for a loose connection. (2) 2 1. For example, 23㏀ indicates -4°F. 22 Check resistance between wires Brown to Orange. Temperature ...
Check the wires Orange to Brown. Result 0Ω Short OFF Open Other Normal SVC Action Change the sensor Replace the refrigerator Check the Temp and resistance (Table-3) 2.- Check for a loose connection. (2) 2 1. For example, 23㏀ indicates -4°F. 22 Check resistance between wires Brown to Orange. Temperature ...
Service Manual
Page 30
Check voltage between wires Black to Gray/Red . 8-2 Refrigerator room LED Lamp doesn't work No Checking flow 1 Check the Refrigerator door switch. Check for loose connection in CON5. 2-. Status Normal Push S/W Result 0 Other Infinity Other SVC Action Go to the 3 Change door Switch Go to ...
Check voltage between wires Black to Gray/Red . 8-2 Refrigerator room LED Lamp doesn't work No Checking flow 1 Check the Refrigerator door switch. Check for loose connection in CON5. 2-. Status Normal Push S/W Result 0 Other Infinity Other SVC Action Go to the 3 Change door Switch Go to ...
Service Manual
Page 35
REFERENCE 9-1 TEST MODE and Removing TPA 1. How to remove Terminal Position Assurance (TPA) After measure the values, you push the test button on the Main PCB, the refrigerator will be enter the TEST MODE. * 1 time : Comp / Damper / All FAN on (All things displayed) Main PCB * 2 times : Damper closed (22 22 displayed) * 3 times : Forced defrost mode (33 33 displayed) 2. How to make TEST MODE If you should put in the TPA again. 35 9.
REFERENCE 9-1 TEST MODE and Removing TPA 1. How to remove Terminal Position Assurance (TPA) After measure the values, you push the test button on the Main PCB, the refrigerator will be enter the TEST MODE. * 1 time : Comp / Damper / All FAN on (All things displayed) Main PCB * 2 times : Damper closed (22 22 displayed) * 3 times : Forced defrost mode (33 33 displayed) 2. How to make TEST MODE If you should put in the TPA again. 35 9.