Owners Manual
Page 13
... exhaust duct can be warm after completing all steps in Gas Dryers Close the door to the dryer drum/drying compartment and, after the dryer has been operating for proper installation of the Dryer. Confirming Heat Source in this manual for three minutes. Effective dryer operation requires appropriate dryer airflow. Prior to the first use of this appliance...
... exhaust duct can be warm after completing all steps in Gas Dryers Close the door to the dryer drum/drying compartment and, after the dryer has been operating for proper installation of the Dryer. Confirming Heat Source in this manual for three minutes. Effective dryer operation requires appropriate dryer airflow. Prior to the first use of this appliance...
Owners Manual
Page 19
... of air and sediment before tightening connection between gas supply and dryer, purge remaining air until odor of gas is insoluble in excess of a qualified person include licensed heating personnel, authorized gas company personnel, and authorized service personnel. • Failure to your area, the gas supply and service for gas dryers. ! Your laundry room must have a qualified person...
... of air and sediment before tightening connection between gas supply and dryer, purge remaining air until odor of gas is insoluble in excess of a qualified person include licensed heating personnel, authorized gas company personnel, and authorized service personnel. • Failure to your area, the gas supply and service for gas dryers. ! Your laundry room must have a qualified person...
Owners Manual
Page 28
...dryer gas shutoff are both fully open. 3.Problem:There are actually stains that the dryer's plug is securely and completely pushed into the laundry room's power outlet Check your dryer to Do • Is the fuse blown, or is blown or the circuit breaker tripped, the dryer might tumble but not heat...'s fuse box / circuit breaker box and replace the fuse or reset the circuit breaker. (IMPORTANT: electric dryers generally use two fuses or breakers.) 2.Problem:My Dryer Doesn 't Heat Question What to dry only clean items, because dirty items can soil clean clothes placed in the same load...
...dryer gas shutoff are both fully open. 3.Problem:There are actually stains that the dryer's plug is securely and completely pushed into the laundry room's power outlet Check your dryer to Do • Is the fuse blown, or is blown or the circuit breaker tripped, the dryer might tumble but not heat...'s fuse box / circuit breaker box and replace the fuse or reset the circuit breaker. (IMPORTANT: electric dryers generally use two fuses or breakers.) 2.Problem:My Dryer Doesn 't Heat Question What to dry only clean items, because dirty items can soil clean clothes placed in the same load...
Owners Manual
Page 29
... of a pair of pants, and this paper, tissue, or similar material can cause excess lint in my clothes after drying. • Did you overload your dryer? • Did you properly sort your larger load into smaller loads. Divide your load of dried clothes. Sometimes a person might catch lint (such as a... exhaust ducts and lint filer. 27 Over-drying a load of laundry can cause static to the manual section on the heat setting, the type of heat used (electric, natural or LP gas), the size of the load, the type of fabrics, the wetness of the clothes and the condition of laundry. It...
... of a pair of pants, and this paper, tissue, or similar material can cause excess lint in my clothes after drying. • Did you overload your dryer? • Did you properly sort your larger load into smaller loads. Divide your load of dried clothes. Sometimes a person might catch lint (such as a... exhaust ducts and lint filer. 27 Over-drying a load of laundry can cause static to the manual section on the heat setting, the type of heat used (electric, natural or LP gas), the size of the load, the type of fabrics, the wetness of the clothes and the condition of laundry. It...
Service Manual
Page 27
Measurement Condition With dryer power on Valve 1 Igniter Valve 2 Power On & Start (Normal Cycle) NO When measuring Valve 1 voltage, More than AC 90V? (10 sec after Igniter off) YES NO • Check Gas connection or Gas supply When measuring terminal resistance on "Valve 1", "Valve 2", Value is more...? (after Off ) YES • Change Valve NO • Harness check • Controller change 26 Test 7 GAS Valve test - Trouble Symptom While operating, Heating will not work. Gas Type Caution When measuring power, be sure to wear insulated gloves, to avoid electric shock.
Measurement Condition With dryer power on Valve 1 Igniter Valve 2 Power On & Start (Normal Cycle) NO When measuring Valve 1 voltage, More than AC 90V? (10 sec after Igniter off) YES NO • Check Gas connection or Gas supply When measuring terminal resistance on "Valve 1", "Valve 2", Value is more...? (after Off ) YES • Change Valve NO • Harness check • Controller change 26 Test 7 GAS Valve test - Trouble Symptom While operating, Heating will not work. Gas Type Caution When measuring power, be sure to wear insulated gloves, to avoid electric shock.