Page 4
...areas free from service or discarded, remove the door to the drying compartment. • Do not allow children to play on the appliance. Part 1 IMPORTANT WARRANTY AND SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USE WARNING For your safety, the information in this manual. • Do not ...exposed to cooking oils in your appliance, follow basic precautions, including the following : This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects, or other flammable or explosive substances as they give off vapors that ...
...areas free from service or discarded, remove the door to the drying compartment. • Do not allow children to play on the appliance. Part 1 IMPORTANT WARRANTY AND SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USE WARNING For your safety, the information in this manual. • Do not ...exposed to cooking oils in your appliance, follow basic precautions, including the following : This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects, or other flammable or explosive substances as they give off vapors that ...
Owner's Manual
Page 9
...• Use as few elbow joints as possible. • Clean old ducts before installing this ducting will cause undesirable drying performance. Part 3 INITIAL STEPS FOR INSTALLING YOUR DRYER STEP 3 Connecting the Exhaust and Venting System. Detach and remove the knockout that the exhaust ...desired venting direction (Right side not available on Exhaust Requirements and Maintenance. Pre-assemble 4" elbow with the above recommendations, then a UL-listed flexible metal transition duct may be vented to make a connection with 4" duct. IMPORTANT: To reduce the risk of exhaust duct must ...
...• Use as few elbow joints as possible. • Clean old ducts before installing this ducting will cause undesirable drying performance. Part 3 INITIAL STEPS FOR INSTALLING YOUR DRYER STEP 3 Connecting the Exhaust and Venting System. Detach and remove the knockout that the exhaust ...desired venting direction (Right side not available on Exhaust Requirements and Maintenance. Pre-assemble 4" elbow with the above recommendations, then a UL-listed flexible metal transition duct may be vented to make a connection with 4" duct. IMPORTANT: To reduce the risk of exhaust duct must ...
Owner's Manual
Page 10
...should be connected to green ground connector. • Securely tighten all connections between the dryer and your house is appropriate for gas leaks with . Part 3 INITIAL STEPS FOR INSTALLING YOUR DRYER STEP 4 Connection of the burner B.T.U rating indicated on the model/serial rating plate. Use 1/2" pipe. 5.... in fire or electrical shock. For LP (Liquefied Petroleum) gas connection, refer to your local codes). 4. Use only a new U.L. listed No. 10 (copper wire only) three conductor power supply cord kit rated 240 Volts (minimum) 30 Amperes and labeled as noted below,...
...should be connected to green ground connector. • Securely tighten all connections between the dryer and your house is appropriate for gas leaks with . Part 3 INITIAL STEPS FOR INSTALLING YOUR DRYER STEP 4 Connection of the burner B.T.U rating indicated on the model/serial rating plate. Use 1/2" pipe. 5.... in fire or electrical shock. For LP (Liquefied Petroleum) gas connection, refer to your local codes). 4. Use only a new U.L. listed No. 10 (copper wire only) three conductor power supply cord kit rated 240 Volts (minimum) 30 Amperes and labeled as noted below,...
Owner's Manual
Page 14
...in wiring so dryer can cause serious injury to dryer is fifteen feet (4.50 m) or less in length, use U.L. (Underwriters Laboratories) listed No. 8 A.W.G. f) The method of wiring the dryer is provided Inside the dryer cabinet. Please contact a qualified electrician to check ...the wiring and grounding must select the method by local codes. If over fifteen feet (4.50 m), use U.L. (Underwriters Laboratories) listed No. 10 A.W.G. Part 5 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS Following are included in the following pages. e) The power cord (pigtail) connection between wall ...
...in wiring so dryer can cause serious injury to dryer is fifteen feet (4.50 m) or less in length, use U.L. (Underwriters Laboratories) listed No. 8 A.W.G. f) The method of wiring the dryer is provided Inside the dryer cabinet. Please contact a qualified electrician to check ...the wiring and grounding must select the method by local codes. If over fifteen feet (4.50 m), use U.L. (Underwriters Laboratories) listed No. 10 A.W.G. Part 5 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS Following are included in the following pages. e) The power cord (pigtail) connection between wall ...
Owner's Manual
Page 15
... of the wire under the screw of covering material from 3 other wires. and be sure that the strain relief screw is tightened. Part 5 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS Review the following options to determine the appropriate electrical connection for your home: 4-wire receptacle (NEMA type14...30R) Use the instructions at this section if your home has a 4-wire receptacle (NEMA type 14-30R) and you will be using a UL listed, 120/240 volt minimum, 30 amp, dryer power supply cord. 4-wire connection : Direct wire Important : Grounding through the neutral conductor is prohibited ...
... of the wire under the screw of covering material from 3 other wires. and be sure that the strain relief screw is tightened. Part 5 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS Review the following options to determine the appropriate electrical connection for your home: 4-wire receptacle (NEMA type14...30R) Use the instructions at this section if your home has a 4-wire receptacle (NEMA type 14-30R) and you will be using a UL listed, 120/240 volt minimum, 30 amp, dryer power supply cord. 4-wire connection : Direct wire Important : Grounding through the neutral conductor is prohibited ...
Specification
Page 2
...T Y 1 Year Labor and Parts UPC CODE DLE0442W 048231 008730 DLG0452W 048231 008747 WDP2W 048231 008334 Design and specifications are periodically tumbled without heat to "set it and go". LoDecibel™ Quiet System LG dryers feature advanced technology that makes them . LG ELECTRONICS INC. 1000 Sylvan Ave...Top Painted Transparent Glass Window Door Door Rim Chrome Cabinet Painted Steel Control Panel Plastic Colors White ELECTRICAL Ratings UL Listed Requirements Gas: 120V, 15 Amps Electric: 120/240V, 30 Amps Type Gas (DLG0452)/Electric (DLE0442) OPTIONS ...
...T Y 1 Year Labor and Parts UPC CODE DLE0442W 048231 008730 DLG0452W 048231 008747 WDP2W 048231 008334 Design and specifications are periodically tumbled without heat to "set it and go". LoDecibel™ Quiet System LG dryers feature advanced technology that makes them . LG ELECTRONICS INC. 1000 Sylvan Ave...Top Painted Transparent Glass Window Door Door Rim Chrome Cabinet Painted Steel Control Panel Plastic Colors White ELECTRICAL Ratings UL Listed Requirements Gas: 120V, 15 Amps Electric: 120/240V, 30 Amps Type Gas (DLG0452)/Electric (DLE0442) OPTIONS ...