... and follow basic safety precautions, including the following: 1) Read all local codes and ordinances. The plug must be plugged into an appropriate outlet that could ignite or explode. 3) Do not allow children to help reduce any servicing unless specifically recommended in the user-maintenance instructions. 9) Do not use fabric softners or...
... and follow basic safety precautions, including the following: 1) Read all local codes and ordinances. The plug must be plugged into an appropriate outlet that could ignite or explode. 3) Do not allow children to help reduce any servicing unless specifically recommended in the user-maintenance instructions. 9) Do not use fabric softners or...
Owner's Manual
Page 11
... pressure in the operating instructions that accompany the dryer. After the dryer starts, the igniter will glow red and the main burner will re-attempt gas ignition after the dryer has been operating for three minutes. If this dryer, start the dryer on a heat setting, as described more... all air is not purged from the inside of detergent and water, with a damp clothe to remove from the gas line, the gas igniter may have ignited. Part 2 INITIAL STEPS FOR INSTALLING YOUR DRYER STEP 6: Preparation of this dryer, start the dryer on a heat setting, as described more...
... pressure in the operating instructions that accompany the dryer. After the dryer starts, the igniter will glow red and the main burner will re-attempt gas ignition after the dryer has been operating for three minutes. If this dryer, start the dryer on a heat setting, as described more... all air is not purged from the inside of detergent and water, with a damp clothe to remove from the gas line, the gas igniter may have ignited. Part 2 INITIAL STEPS FOR INSTALLING YOUR DRYER STEP 6: Preparation of this dryer, start the dryer on a heat setting, as described more...
Service Manual
Page 12
...Ω Remark • Electric type Measure resistance of the following terminal Valve 1 terminal Valve 2 terminal • Gas type Resistance value : > 1.5kg ~ Resistance value : > 1.5~2.5kg 11. Igniter valve 2 Measure resistance of terminal to terminal Temperature condition : 58°F ~ (10~40°C) 58°F ~ 104F (10~40°C) Resistance value : 10Ω •...
...Ω Remark • Electric type Measure resistance of the following terminal Valve 1 terminal Valve 2 terminal • Gas type Resistance value : > 1.5kg ~ Resistance value : > 1.5~2.5kg 11. Igniter valve 2 Measure resistance of terminal to terminal Temperature condition : 58°F ~ (10~40°C) 58°F ~ 104F (10~40°C) Resistance value : 10Ω •...
Service Manual
Page 24
... longer. YES NO • Check thermostat Hi limit Safety Igniter operates? (after 1 min, Igniter becomes reddish) YES NO • Check Igniter & Frame detect When measuring Valve 2 voltage, Value is more than1.5 ~ 2.5kΩ? (Measure after Igniter off) YES NO • Check Gas connection or Gas ...supply When measuring terminal resistance on "Valve 1", "Valve 2", Value is more than AC 90V? Measurement Condition With dryer power on Valve 1 Igniter Valve 2 Power On & Start (Normal Cycle) NO When measuring Valve 1 voltage, More than AC 90V? (10 sec after Off ) YES ...
... longer. YES NO • Check thermostat Hi limit Safety Igniter operates? (after 1 min, Igniter becomes reddish) YES NO • Check Igniter & Frame detect When measuring Valve 2 voltage, Value is more than1.5 ~ 2.5kΩ? (Measure after Igniter off) YES NO • Check Gas connection or Gas ...supply When measuring terminal resistance on "Valve 1", "Valve 2", Value is more than AC 90V? Measurement Condition With dryer power on Valve 1 Igniter Valve 2 Power On & Start (Normal Cycle) NO When measuring Valve 1 voltage, More than AC 90V? (10 sec after Off ) YES ...
Service Manual
Page 26
GAS VALVE FLOW START KEY PUSH "VALVE 1" ON IGNITE ON IGNITE TEMPERATURE ABOUT 370"F YES FRAME DETECT OPEN IGNITE OFF "VALVE 2" ON GAS IGNITION YES DRYING NO NO FRAME DETECT CLOSE "VALVE 2" OFF GAS IGNITION START VALVE 1 IGNITER FRAME DETECT VALVE 2 ON ON CLOSE OFF OFF OPEN ON GAS IGNITION GAS VALVE STRUCTURE 25
GAS VALVE FLOW START KEY PUSH "VALVE 1" ON IGNITE ON IGNITE TEMPERATURE ABOUT 370"F YES FRAME DETECT OPEN IGNITE OFF "VALVE 2" ON GAS IGNITION YES DRYING NO NO FRAME DETECT CLOSE "VALVE 2" OFF GAS IGNITION START VALVE 1 IGNITER FRAME DETECT VALVE 2 ON ON CLOSE OFF OFF OPEN ON GAS IGNITION GAS VALVE STRUCTURE 25