Page 11
Hi limit Thermostat (Auto reset) 3. "NC" (1-3) Terminal : "COM" - "NC" (1-3) Terminal : "COM" - NC" 1. Measure resistance of terminal to terminal Open at 257 ± 9°F (125 ± 5°C) Close at 221 ±..." - CAUTION When checking the Component, be sure to terminal be replaced Safety Open at 149 ± 9°F (65 ± 5°C) Same shape as Outlet Thermostat. Outlet Thermostat ( Auto reset) • Check Top Marking : N85 4. to turn the power off . Door switch 6. "NO" (1-2) 2) Door switch push : push Terminal : "COM" - "NO" (1-2) Resistance value < 1Ω...
Hi limit Thermostat (Auto reset) 3. "NC" (1-3) Terminal : "COM" - "NC" (1-3) Terminal : "COM" - NC" 1. Measure resistance of terminal to terminal Open at 257 ± 9°F (125 ± 5°C) Close at 221 ±..." - CAUTION When checking the Component, be sure to terminal be replaced Safety Open at 149 ± 9°F (65 ± 5°C) Same shape as Outlet Thermostat. Outlet Thermostat ( Auto reset) • Check Top Marking : N85 4. to turn the power off . Door switch 6. "NO" (1-2) 2) Door switch push : push Terminal : "COM" - "NO" (1-2) Resistance value < 1Ω...
Service Manual
Page 13
Outlet Thermostat (Manual reset) • Check Top Marking : N100 Test Procedure Measure resistance of terminal to terminal Open at 203 ± 7°F (95 ± 5°C) Close at 158 ± 9... type • Gas funnel Measure resistance of terminal to terminal Open at 212 ± 12°F (100 ± 7°C) Manual reset If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 12 Outlet Thermostat (Auto reset) • Check Top Marking : N95 13. Component 13.
Outlet Thermostat (Manual reset) • Check Top Marking : N100 Test Procedure Measure resistance of terminal to terminal Open at 203 ± 7°F (95 ± 5°C) Close at 158 ± 9... type • Gas funnel Measure resistance of terminal to terminal Open at 212 ± 12°F (100 ± 7°C) Manual reset If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 12 Outlet Thermostat (Auto reset) • Check Top Marking : N95 13. Component 13.