Website:http://www.LGservice.com [For U.S.A] www.lg.ca [For Canada] ELECTRIC & GAS DRYER SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLES CORRECTLY BEFORE OFFERING SERVICE. MODEL : DLE5911W DLE2511W DLE5932W DLE5932S DLE2532W DLE0332W DLG5911W DLG2511W DLG5932W DLG5932S DLG2532W DLG0332W
Website:http://www.LGservice.com [For U.S.A] www.lg.ca [For Canada] ELECTRIC & GAS DRYER SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLES CORRECTLY BEFORE OFFERING SERVICE. MODEL : DLE5911W DLE2511W DLE5932W DLE5932S DLE2532W DLE0332W DLG5911W DLG2511W DLG5932W DLG5932S DLG2532W DLG0332W
Service Manual
Page 4
... 4 MOISTURE SENSOR 20 9-5. TEST 6 HEATER SWITCH TEST - SPECIFICATIONS ...4 2. COMPONENT TESTING INFORMATION 10 6. OUT ...14 8. ELECTRIC TYPE 22 9-7. GAS TYPE 23 10. EXPLODED VIEW ...32 12-1. CONTROL PANEL & PLATE ASSEMBLY 32 12-2. COLUMBUS DRYER CYCLE PROCESS 9 5. TEST 1 120VAC ELECTRICAL SUPPLY 17 9-2. MEASURE WITH POWER OFF 18 9-3. CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS 24...
... 4 MOISTURE SENSOR 20 9-5. TEST 6 HEATER SWITCH TEST - SPECIFICATIONS ...4 2. COMPONENT TESTING INFORMATION 10 6. OUT ...14 8. ELECTRIC TYPE 22 9-7. GAS TYPE 23 10. EXPLODED VIEW ...32 12-1. CONTROL PANEL & PLATE ASSEMBLY 32 12-2. COLUMBUS DRYER CYCLE PROCESS 9 5. TEST 1 120VAC ELECTRICAL SUPPLY 17 9-2. MEASURE WITH POWER OFF 18 9-3. CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS 24...
Service Manual
Page 5
... On / Off Sensor Moisture Temperature Equipped Equipped Electro sensor Thermistor Reversible Door Adopted Drum Stainless Steel Dryer Rack Equipped Child lock Equipped Interior Light Equipped Product (WXHXD) Packing (WXHXD) 27" x 42... Levels 5 5 3 Audible End of Programs 9 9 5 No. 1 SPECIFICATIONS ITEM DLE5932W DLE5932S DLE2532W DLG5932W DLG5932S DLG2532W REMARK Material & Finishes Color Top Plate Door Trim White Porcelain Silver Titanium...(26A) ELECTRICITY CONSUMPTION MOTOR HEATER LAMP 250W (4.5A) 5400W (22.5A) 15W (125mA) AC 120V AC 240V ( ELECTRIC TYPE) AC...
... On / Off Sensor Moisture Temperature Equipped Equipped Electro sensor Thermistor Reversible Door Adopted Drum Stainless Steel Dryer Rack Equipped Child lock Equipped Interior Light Equipped Product (WXHXD) Packing (WXHXD) 27" x 42... Levels 5 5 3 Audible End of Programs 9 9 5 No. 1 SPECIFICATIONS ITEM DLE5932W DLE5932S DLE2532W DLG5932W DLG5932S DLG2532W REMARK Material & Finishes Color Top Plate Door Trim White Porcelain Silver Titanium...(26A) ELECTRICITY CONSUMPTION MOTOR HEATER LAMP 250W (4.5A) 5400W (22.5A) 15W (125mA) AC 120V AC 240V ( ELECTRIC TYPE) AC...
Service Manual
Page 18
... Controller and "WH3- Check if the voltage measured between Connector "RD3- " (Black) linked to Controller. (LED, Display off) Measurement Condition With Dryer Power On; YES NO • Check the fuse or circuit breaker. N(White) L (Black) L (Led) YES Check if the Controller wire... "(White) is 110V ~ 125V? • Check if Power NO Cord is properly connected. Connector linked to and avoid an electric shock. Test 1 120VAC Electrical supply Caution When measuring power, be sure to wear insulated gloves, to Controller. Does Power Cord N( Natural) line match to...
... Controller and "WH3- Check if the voltage measured between Connector "RD3- " (Black) linked to Controller. (LED, Display off) Measurement Condition With Dryer Power On; YES NO • Check the fuse or circuit breaker. N(White) L (Black) L (Led) YES Check if the Controller wire... "(White) is 110V ~ 125V? • Check if Power NO Cord is properly connected. Connector linked to and avoid an electric shock. Test 1 120VAC Electrical supply Caution When measuring power, be sure to wear insulated gloves, to Controller. Does Power Cord N( Natural) line match to...
Service Manual
Page 21
... Controller. Normal Condition Table 2. Is the measurement within the range of Table 2 NO when measuring the voltage in Electric load, is resistance below 1Ω? YES • Replace Control and Check. Measurement Condition Turn the Dryer's Power Off, then measure resistance. linking connector. Take 6pin Connector from Washing Machine Damp Dry 10% ~ Dried...
... Controller. Normal Condition Table 2. Is the measurement within the range of Table 2 NO when measuring the voltage in Electric load, is resistance below 1Ω? YES • Replace Control and Check. Measurement Condition Turn the Dryer's Power Off, then measure resistance. linking connector. Take 6pin Connector from Washing Machine Damp Dry 10% ~ Dried...
Service Manual
Page 24
... • Check thermostat Hi limit Safety Igniter operates? (after Off ) YES • Change Valve NO • Harness check • Controller change 23 Measurement Condition With dryer power on Valve 1 Igniter Valve 2 Power On & Start (Normal Cycle) NO When measuring Valve 1 voltage, More than AC 90V? (10 sec after Igniter off) YES... detect When measuring Valve 2 voltage, Value is more than AC 90V? Gas Type Caution When measuring power, be sure to wear insulated gloves, to avoid electric shock. Trouble Symptom While operating, Heating will not work.
... • Check thermostat Hi limit Safety Igniter operates? (after Off ) YES • Change Valve NO • Harness check • Controller change 23 Measurement Condition With dryer power on Valve 1 Igniter Valve 2 Power On & Start (Normal Cycle) NO When measuring Valve 1 voltage, More than AC 90V? (10 sec after Igniter off) YES... detect When measuring Valve 2 voltage, Value is more than AC 90V? Gas Type Caution When measuring power, be sure to wear insulated gloves, to avoid electric shock. Trouble Symptom While operating, Heating will not work.