Service Manual - Page 1
MODEL : DLE5911W DLE2511W DLE5932W DLE5932S DLE2532W DLE0332W
DLG5911W DLG2511W DLG5932W DLG5932S DLG2532W DLG0332W Website:http://www.LGservice.com [For U.S.A] www.lg.ca [For Canada]
ELECTRIC & GAS DRYER SERVICE MANUAL
CAUTION
READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLES CORRECTLY BEFORE OFFERING SERVICE.
Service Manual - Page 3
... to work well after performing the necessary checks.
Avoid touching electronic parts or terminal contacts; IMPORTANT SAFETY NOTICE
The information in this service guide is intended for diagnosis or test purposes, disconnect the power immediately after repair is required for use any phone in your building. WARNING ! If electrical power is finished, but failure may appear...
Service Manual - Page 4
... ASSEMBLY 32 12-2. INSTALLATION INSTRUCTIONS 6 4. CONTROL LAY - TEST 2 THERMISTOR TEST --- MEASURE WITH POWER OFF 18 9-3. ELECTRIC TYPE 22 9-7. COLUMBUS DRYER CYCLE PROCESS 9 5. GAS TYPE 23 10. REPLACEMENT PARTS LIST 36
3 CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS 24 11. DRUM & MOTOR ASSEMBLY : GAS TYPE 35 13. OUT ...14 8. SPECIFICATIONS ...4 2. CABINET & DOOR ASSEMBLY...
Service Manual - Page 5
...of Dry Option
5
5
5
No. Weight (lbs): Net / Gross
126 / 144
No. 1 SPECIFICATIONS
ITEM
DLE5932W DLE5932S DLE2532W DLG5932W DLG5932S DLG2532W
REMARK
Material & Finishes
Color Top Plate Door Trim
White Porcelain
Silver
Titanium Porcelain Chrome
White Painted White
POWER SUPPLY
120V / 240V 60Hz (26A)
ELECTRICITY CONSUMPTION
MOTOR HEATER LAMP
250W (4.5A) 5400W (22.5A) 15W (125mA...
Service Manual - Page 6
2 FEATURES AND BENEFITS
DLE5911W / DLG5911W DLE2511W / DLG2511W DLE5932W / DLG5932W / DLE5932S / DLG5932S DLE2532W / DLG2532W
5
Service Manual - Page 10
...177;5°C
Speed dry (High) - 25min Saturation (70±5°C) (5min) (47±5°C)
Manual Dry **
Freshen Up
(Medium High)
-
20min Saturation (66±5°C) (5min) (47±5...cycle
* Sense dry : "Dry Level" is set by users. ** Manual dry : "Temperature control" is set by users.
9 4 COLUMBUS DRYER CYCLE PROCESS
Cycle
Default
Conditions of operation and termination
Drying...
Service Manual - Page 17
... test 4
Gas valve See test 7
See test 5 Off automatically after 5 minutes
During check, If the door is increasing.
Displays Moisture Sensor Operation: If moisture sensor is open may trip the Thermostat attached to the Heater, therefore do not activate it manually. (Do not press the door switch to operate the heater while the...
Service Manual - Page 18
... Terminal Block and Power Cord
are connected (Check Plug ). NO
- YES
Replace controIler.
17 Trouble Symptom No power was applied to Terminal Center N(Natural) line?
• Reconnect the controller.
Check if the voltage measured between Connector "RD3- Check the outlet, is
disconnected.
N(White)
L (Black)
L (Led)
YES
Check if the Controller wire is the voltage 110V ~ 125V...
Service Manual - Page 20
... is closed . NO
YES
• Replace Control. (Relay check)
• Check Controller connector.
• Replace Outlet • Thermostat.
(Refer to 'Component')
• Check Idler Assembly. • Drum Belt cuts off • Drum Belt takes off , and do voltage discharge. (When discharging, contact the metal plug of Power cord with earth line.)
Trouble Symptom Drum will not rotate...
Service Manual - Page 21
...of Power cord with earth line.)
Trouble Symptom Degree of dryness does not match ... of Table 2
NO
when measuring the voltage in Electric load, is resistance below 1Ω? IMC Ratio and...Dryer's Power Off, then measure resistance. Take 6pin Connector from Washing Machine
Damp Dry
10% ~ Dried clothes 205 ~ 240
Over 4.0V
Completely-dried clothes
20 YES
• Replace Control and Check...
Service Manual - Page 22
... After turning Dryer Power Off, measure resistance. Check if
resistance is closed . NO
• Door switch Check (Refer to Component testing.)
Measure while Door is closed . Measure while Door is 300~60Ω between "BL2- YES
• Door switch Check (Refer to Component testing.)
• Check Lamp. (When opening Door, Drum motor and
Trouble Symptom Heater...
Service Manual - Page 23
...; Replace TH3 (HI-Limit Thermostat). YES
Check Controller. Measurement Condition After turning Power off , and do voltage discharge. (When discharging, contact the metal plug of measured
resistance is below 18 ~ 22Ω?
2. Check Motor. Test 6 Heater switch test -
Check if the value of Power cord with earth line.)
Trouble Symptom
While operating, Heating will not work. Electric...
Service Manual - Page 24
Trouble Symptom
While operating, Heating will not work.
YES
NO
• Check thermostat Hi limit Safety
Igniter operates? (after 1 min, Igniter becomes reddish)
YES
NO
• Check Igniter & Frame detect
When measuring Valve 2 voltage, Value is more than1.5 ~ 2.5kΩ? (Measure after Igniter off)
YES
NO
• Check Gas connection or Gas supply
When measuring terminal ...
Service Manual - Page 25
..., Natural Gas mode is on sale as a Service
Part to authorized servicers only.
10 CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS)
!
Gas type Orifice P/No Marking Shape Natural Gas 4948EL4001B NCU Propane Gas 4948EL4002B PCU
Kit contents : Orifice (Dia. = 1.613mm, for Propane Gas) : Replace Label : Instruction sheet
24 STEP 1 : VALVE SETTING
Full open "Change screw"
STEP 2 : ORIFICE...
LG DLE5932S Reviews