Service Manual
Page 1
MODEL : DLE5911W DLE2511W DLE5932W DLE5932S DLE2532W DLE0332W DLG5911W DLG2511W DLG5932W DLG5932S DLG2532W DLG0332W Website:http://www.LGservice.com [For U.S.A] www.lg.ca [For Canada] ELECTRIC & GAS DRYER SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLES CORRECTLY BEFORE OFFERING SERVICE.
MODEL : DLE5911W DLE2511W DLE5932W DLE5932S DLE2532W DLE0332W DLG5911W DLG2511W DLG5932W DLG5932S DLG2532W DLG0332W Website:http://www.LGservice.com [For U.S.A] www.lg.ca [For Canada] ELECTRIC & GAS DRYER SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLES CORRECTLY BEFORE OFFERING SERVICE.
Service Manual
Page 3
...appliance. - handle electronic control assembly by individuals possessing adequate backgrounds of electrical, electronic, and mechanical experience. WHAT TO DO IF YOU SMELL GAS: Do not try to a green ground connection point or unpainted metal in anti-static bag, observe above instructions. 2 Clear the room..., building or area of this product. If you cannot reach your gas supplier, call your building. RECONNECT ALL GROUNDING DEVICES If grounding wires, screws, straps, clips, nuts, or washers used to complete a ...
...appliance. - handle electronic control assembly by individuals possessing adequate backgrounds of electrical, electronic, and mechanical experience. WHAT TO DO IF YOU SMELL GAS: Do not try to a green ground connection point or unpainted metal in anti-static bag, observe above instructions. 2 Clear the room..., building or area of this product. If you cannot reach your gas supplier, call your building. RECONNECT ALL GROUNDING DEVICES If grounding wires, screws, straps, clips, nuts, or washers used to complete a ...
Service Manual
Page 4
...SWITCH TEST 21 9-6. ELECTRIC TYPE 22 9-7. CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS 24 11. REPLACEMENT PARTS LIST 36 3 CONTENTS 1. COMPONENT TESTING INFORMATION 10 6. WIRING DIAGRAM ...15 9. GAS TYPE 23 10. DRUM & MOTOR ASSEMBLY : GAS TYPE 35 13. DIAGNOSTIC TEST ...16 9-1. ...MEASURE WITH POWER OFF 18 9-3. SPECIFICATIONS ...4 2. TEST 7 GAS VALVE TEST - DISASSEMBLY INSTRUCTIONS 26 12. EXPLODED VIEW ......
...SWITCH TEST 21 9-6. ELECTRIC TYPE 22 9-7. CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS 24 11. REPLACEMENT PARTS LIST 36 3 CONTENTS 1. COMPONENT TESTING INFORMATION 10 6. WIRING DIAGRAM ...15 9. GAS TYPE 23 10. DRUM & MOTOR ASSEMBLY : GAS TYPE 35 13. DIAGNOSTIC TEST ...16 9-1. ...MEASURE WITH POWER OFF 18 9-3. SPECIFICATIONS ...4 2. TEST 7 GAS VALVE TEST - DISASSEMBLY INSTRUCTIONS 26 12. EXPLODED VIEW ......
Service Manual
Page 5
... / 240V 60Hz (26A) ELECTRICITY CONSUMPTION MOTOR HEATER LAMP 250W (4.5A) 5400W (22.5A) 15W (125mA) AC 120V AC 240V ( ELECTRIC TYPE) AC 120V GAS VALVE 13W (110mA) X 2 AC 120V ( GAS TYPE) CONTROL TYPE Electronic DRUM CAPACITY 7.3 cu.ft. Weight (lbs): Net / Gross 126 / 144 No. of Dry Option 5 5 5 No. of Dry Levels...
... / 240V 60Hz (26A) ELECTRICITY CONSUMPTION MOTOR HEATER LAMP 250W (4.5A) 5400W (22.5A) 15W (125mA) AC 120V AC 240V ( ELECTRIC TYPE) AC 120V GAS VALVE 13W (110mA) X 2 AC 120V ( GAS TYPE) CONTROL TYPE Electronic DRUM CAPACITY 7.3 cu.ft. Weight (lbs): Net / Gross 126 / 144 No. of Dry Option 5 5 5 No. of Dry Levels...
Service Manual
Page 9
... rear of dryer 4 Black Iron Pipe Shorter than 20' (6.1 m) - Make sure you do not damage the pipe thread when removing the cap. 3. Certified Connector) 2 1/8" N.P.T. Connect Gas Supply Pipe (Gas Dryer ONLY) For further assistance, refer to gas supply pipe using a new flexible stainless steel connector. 4. Make certain your laundry room. For L.P. (Liquefied Petroleum...
... rear of dryer 4 Black Iron Pipe Shorter than 20' (6.1 m) - Make sure you do not damage the pipe thread when removing the cap. 3. Certified Connector) 2 1/8" N.P.T. Connect Gas Supply Pipe (Gas Dryer ONLY) For further assistance, refer to gas supply pipe using a new flexible stainless steel connector. 4. Make certain your laundry room. For L.P. (Liquefied Petroleum...
Service Manual
Page 12
... terminal to terminal Open at 370°F ((Maximum) Close at 320°F Resistance value ∞ Resistance value < 1Ω • Gas type 11 Heater 8. Frame Detect Measure resistance of terminal to terminal Temperature condition : 58°F ~ (10~40°C) 58°F... : 10Ω • Heater case Hi limit • Electric type • See Page 13 10. Gas valve valve 1 Measure resistance of terminal to terminal Resistance value : 100~800Ω • Gas type 12. Motor Test Procedure Measure resistance of the following terminal Terminal : 1 (COM) - 2 Terminal :...
... terminal to terminal Open at 370°F ((Maximum) Close at 320°F Resistance value ∞ Resistance value < 1Ω • Gas type 11 Heater 8. Frame Detect Measure resistance of terminal to terminal Temperature condition : 58°F ~ (10~40°C) 58°F... : 10Ω • Heater case Hi limit • Electric type • See Page 13 10. Gas valve valve 1 Measure resistance of terminal to terminal Resistance value : 100~800Ω • Gas type 12. Motor Test Procedure Measure resistance of the following terminal Terminal : 1 (COM) - 2 Terminal :...
Service Manual
Page 13
... at 203 ± 7°F (95 ± 5°C) Close at 158 ± 9°F (70 ± 5°C) Check result Resistance value ∞ Continuity < 1Ω Remark • Gas type • Gas funnel Measure resistance of terminal to terminal Open at 212 ± 12°F (100 ± 7°C) Manual reset If thermal fuse is open must...
... at 203 ± 7°F (95 ± 5°C) Close at 158 ± 9°F (70 ± 5°C) Check result Resistance value ∞ Continuity < 1Ω Remark • Gas type • Gas funnel Measure resistance of terminal to terminal Open at 212 ± 12°F (100 ± 7°C) Manual reset If thermal fuse is open must...
Service Manual
Page 17
...power up Defective LED Thermistor open ) ACTIVATING THE DIAGNOSTIC TEST MODE 1. ELECTRIC TYPE : Heater runs GAS TYPE : GAS Valve runs (Display the Temperature of Inside drum.) ELECTRIC TYPE Motor + Heater 1 + Heater 2 (5400W) GAS TYPE Motor Type Current Temp. (5 ~ 70) In normal state if displayed temp. This TEST ...should be in Standby (unit plugged in, display off beep sound See test 3 See test 4 Gas valve See test 7 See test 5 Off automatically after 5 minutes During check, If the door is below 180, in 4min : 113°F (45°...
...power up Defective LED Thermistor open ) ACTIVATING THE DIAGNOSTIC TEST MODE 1. ELECTRIC TYPE : Heater runs GAS TYPE : GAS Valve runs (Display the Temperature of Inside drum.) ELECTRIC TYPE Motor + Heater 1 + Heater 2 (5400W) GAS TYPE Motor Type Current Temp. (5 ~ 70) In normal state if displayed temp. This TEST ...should be in Standby (unit plugged in, display off beep sound See test 3 See test 4 Gas valve See test 7 See test 5 Off automatically after 5 minutes During check, If the door is below 180, in 4min : 113°F (45°...
Service Manual
Page 24
... time takes longer. Measurement Condition With dryer power on "Valve 1", "Valve 2", Value is more than1.5 ~ 2.5kΩ? (Measure after Igniter off) YES NO • Check Gas connection or Gas supply When measuring terminal resistance on Valve 1 Igniter Valve 2 Power On & Start (Normal Cycle) NO When measuring Valve 1 voltage, More than AC 90V...
... time takes longer. Measurement Condition With dryer power on "Valve 1", "Valve 2", Value is more than1.5 ~ 2.5kΩ? (Measure after Igniter off) YES NO • Check Gas connection or Gas supply When measuring terminal resistance on Valve 1 Igniter Valve 2 Power On & Start (Normal Cycle) NO When measuring Valve 1 voltage, More than AC 90V...
Service Manual
Page 25
.... Warning After Natural Gas Setting, applying Propane Gas Orifice or wrong use of Natural Gas Orifice will result in fire. Gas type Orifice P/No Marking Shape Natural Gas 4948EL4001B NCU Propane Gas 4948EL4002B PCU Kit contents : Orifice (Dia. = 1.613mm, for Propane Gas) : Replace Label : Instruction sheet 24 Replace Natural Gas orifice with Propane Gas orifice. Propane Gas Orifice is set...
.... Warning After Natural Gas Setting, applying Propane Gas Orifice or wrong use of Natural Gas Orifice will result in fire. Gas type Orifice P/No Marking Shape Natural Gas 4948EL4001B NCU Propane Gas 4948EL4002B PCU Kit contents : Orifice (Dia. = 1.613mm, for Propane Gas) : Replace Label : Instruction sheet 24 Replace Natural Gas orifice with Propane Gas orifice. Propane Gas Orifice is set...
Service Manual
Page 26
GAS VALVE FLOW START KEY PUSH "VALVE 1" ON IGNITE ON IGNITE TEMPERATURE ABOUT 370"F YES FRAME DETECT OPEN IGNITE OFF "VALVE 2" ON GAS IGNITION YES DRYING NO NO FRAME DETECT CLOSE "VALVE 2" OFF GAS IGNITION START VALVE 1 IGNITER FRAME DETECT VALVE 2 ON ON CLOSE OFF OFF OPEN ON GAS IGNITION GAS VALVE STRUCTURE 25
GAS VALVE FLOW START KEY PUSH "VALVE 1" ON IGNITE ON IGNITE TEMPERATURE ABOUT 370"F YES FRAME DETECT OPEN IGNITE OFF "VALVE 2" ON GAS IGNITION YES DRYING NO NO FRAME DETECT CLOSE "VALVE 2" OFF GAS IGNITION START VALVE 1 IGNITER FRAME DETECT VALVE 2 ON ON CLOSE OFF OFF OPEN ON GAS IGNITION GAS VALVE STRUCTURE 25