IC-314 User Guide
Page 5
... Print Driver software in Mac OS X 21 3 Calibration...23 Calibration overview...23 Creating calibration tables with the Konica Minolta Intelligent Quality Optimizer 24 Creating calibration tables with the X-Rite i1/iSis/i1iO spectrophotometer 26 Connecting the X-Rite i1...table 32 Creating calibration tables with the Konica Minolta FD-9 spectrophotometer 37 Using the Konica Minolta FD-9 spectrophotometer to create a calibration table 38 Creating calibration tables with the Konica Minolta FD-5/FD-7 spectrophotometer 40 Connecting the Konica Minolta FD‑5/FD‑7 spectrophotometer to...
... Print Driver software in Mac OS X 21 3 Calibration...23 Calibration overview...23 Creating calibration tables with the Konica Minolta Intelligent Quality Optimizer 24 Creating calibration tables with the X-Rite i1/iSis/i1iO spectrophotometer 26 Connecting the X-Rite i1...table 32 Creating calibration tables with the Konica Minolta FD-9 spectrophotometer 37 Using the Konica Minolta FD-9 spectrophotometer to create a calibration table 38 Creating calibration tables with the Konica Minolta FD-5/FD-7 spectrophotometer 40 Connecting the Konica Minolta FD‑5/FD‑7 spectrophotometer to...
IC-314 User Guide
Page 34
... list, select the tray from which you want to create calibration tables. 24 Chapter 3-Calibration Creating calibration tables with the Konica Minolta Intelligent Quality Optimizer This section describes how to use the Konica Minolta Intelligent Quality Optimizer to print. Requirements: ● The Print queue must be enabled and the printer must be connected to...
... list, select the tray from which you want to create calibration tables. 24 Chapter 3-Calibration Creating calibration tables with the Konica Minolta Intelligent Quality Optimizer This section describes how to use the Konica Minolta Intelligent Quality Optimizer to print. Requirements: ● The Print queue must be enabled and the printer must be connected to...
IC-314 User Guide
Page 35
... Media Types, or choose Select and select the respective media types to which you want the calibration table to save the calibration results with the Konica Minolta Intelligent Quality Optimizer 25 4. Click Finish. Note: The Number of copies and Engine Calibration options are not available when using the Intelligent Quality Optimizer to...
... Media Types, or choose Select and select the respective media types to which you want the calibration table to save the calibration results with the Konica Minolta Intelligent Quality Optimizer 25 4. Click Finish. Note: The Number of copies and Engine Calibration options are not available when using the Intelligent Quality Optimizer to...
IC-314 User Guide
Page 47
...you want the calibration results saved As default name or select Save as described in the text box. Click Finish. Creating calibration tables with the Konica Minolta FD-9 spectrophotometer 37 14. In the Apply to area, choose if you want the calibration table to apply to All Media Types, or choose...to the next job that prints, provided that was calibrated, unless you want the calibration table to apply. 16. Creating calibration tables with the Konica Minolta FD-9 spectrophotometer This section describes how to use the paper stock that the job ticket is programmed to use the...
...you want the calibration results saved As default name or select Save as described in the text box. Click Finish. Creating calibration tables with the Konica Minolta FD-9 spectrophotometer 37 14. In the Apply to area, choose if you want the calibration table to apply to All Media Types, or choose...to the next job that prints, provided that was calibrated, unless you want the calibration table to apply. 16. Creating calibration tables with the Konica Minolta FD-9 spectrophotometer This section describes how to use the paper stock that the job ticket is programmed to use the...
IC-314 User Guide
Page 48
... will be prompted to choose which FD-9 device to finish before proceeding further. ● Make sure that FD-9 is selected. 38 Chapter 3-Calibration Using the Konica Minolta FD-9 spectrophotometer to create a calibration table Requirements: ● Your FD-9 spectrophotometer must be in Ready mode.
... will be prompted to choose which FD-9 device to finish before proceeding further. ● Make sure that FD-9 is selected. 38 Chapter 3-Calibration Using the Konica Minolta FD-9 spectrophotometer to create a calibration table Requirements: ● Your FD-9 spectrophotometer must be in Ready mode.
IC-314 User Guide
Page 49
... dpi. 6. You can follow the process from the printer. 7. Collect the chart from the display window on the FD-9 spectrophotometer. Creating calibration tables with the Konica Minolta FD-9 spectrophotometer 39 3. In the Tray list, select the tray from which you want to print.
... dpi. 6. You can follow the process from the printer. 7. Collect the chart from the display window on the FD-9 spectrophotometer. Creating calibration tables with the Konica Minolta FD-9 spectrophotometer 39 3. In the Tray list, select the tray from which you want to print.
IC-314 User Guide
Page 50
...Calibration 8. Click Finish. The new calibration table is saved and applied to the next job that prints, provided that was calibrated. Connecting the Konica Minolta FD‑5/FD‑7 spectrophotometer to the IC-314 print controller Before you want the calibration table to create calibration tables. In the Save...the calibration table to apply to All Media Types, or choose Select and select the respective media types to which you connect the Konica Minolta FD‑5/FD‑7 spectrophotometer to the IC-314 print controller, make sure that it has been calibrated and set according to ...
...Calibration 8. Click Finish. The new calibration table is saved and applied to the next job that prints, provided that was calibrated. Connecting the Konica Minolta FD‑5/FD‑7 spectrophotometer to the IC-314 print controller Before you want the calibration table to create calibration tables. In the Save...the calibration table to apply to All Media Types, or choose Select and select the respective media types to which you connect the Konica Minolta FD‑5/FD‑7 spectrophotometer to the IC-314 print controller, make sure that it has been calibrated and set according to ...
IC-314 User Guide
Page 51
... the IC-314 print controller. In the following procedure the instrument is turned OFF before the USB cable is installed. Creating calibration tables with the Konica Minolta FD-5/FD-7 spectrophotometer 41 The USB cable can be connected and disconnected even when the instrument's power is ON. Turn off the FD‑5/FD...
... the IC-314 print controller. In the following procedure the instrument is turned OFF before the USB cable is installed. Creating calibration tables with the Konica Minolta FD-5/FD-7 spectrophotometer 41 The USB cable can be connected and disconnected even when the instrument's power is ON. Turn off the FD‑5/FD...
IC-314 User Guide
Page 52
...-314 print controller for the instrument, the measuring button can be connected to the USB port on the IC-314 print controller. Using the Konica Minolta FD‑5/FD‑7 spectrophotometer to create a calibration table Requirements: ● Your FD‑5/FD‑7 spectrophotometer must be warmed up.... on the instrument's LCD screen. If this time the instrument's control buttons and measuring button are ready to use the Konica Minolta FD‑5/FD‑7 spectrophotometer to the IC-314 print controller, the instrument automatically enters communication mode and Communicating...
...-314 print controller for the instrument, the measuring button can be connected to the USB port on the IC-314 print controller. Using the Konica Minolta FD‑5/FD‑7 spectrophotometer to create a calibration table Requirements: ● Your FD‑5/FD‑7 spectrophotometer must be warmed up.... on the instrument's LCD screen. If this time the instrument's control buttons and measuring button are ready to use the Konica Minolta FD‑5/FD‑7 spectrophotometer to the IC-314 print controller, the instrument automatically enters communication mode and Communicating...
IC-314 User Guide
Page 53
... icon on the FD‑5/ FD‑7, as the device. From the Measuring device list, select FD-5 or FD‑7. b. Creating calibration tables with the Konica Minolta FD-5/FD-7 spectrophotometer 43 1. Correctly set the device on the White Calibration plate that has the same pairing number as follows: a. To enable the IC...
... icon on the FD‑5/ FD‑7, as the device. From the Measuring device list, select FD-5 or FD‑7. b. Creating calibration tables with the Konica Minolta FD-5/FD-7 spectrophotometer 43 1. Correctly set the device on the White Calibration plate that has the same pairing number as follows: a. To enable the IC...
IC-314 User Guide
Page 55
... . b. Note: Make sure that has nothing printed on the chart in the order in the ruler grooves and align the specimen measuring port with the Konica Minolta FD-5/FD-7 spectrophotometer 45 that the device can measure each separation on it touches the ruler's opening to measure. Always start and finish scanning from...
... . b. Note: Make sure that has nothing printed on the chart in the order in the ruler grooves and align the specimen measuring port with the Konica Minolta FD-5/FD-7 spectrophotometer 45 that the device can measure each separation on it touches the ruler's opening to measure. Always start and finish scanning from...
IC-314 User Guide
Page 57
... the calibration table to all paper types, as , and enter a name for the calibration table in the next step. 12. Creating calibration tables with the Konica Minolta FD-5/FD-7 spectrophotometer 47 Notes: ● If, at any stage, the scanning does not complete properly, click Reset and scan again. ● If an error...
... the calibration table to all paper types, as , and enter a name for the calibration table in the next step. 12. Creating calibration tables with the Konica Minolta FD-5/FD-7 spectrophotometer 47 Notes: ● If, at any stage, the scanning does not complete properly, click Reset and scan again. ● If an error...
IC-314 User Guide
Page 64
.... Place it as part of Black ramp tints. 12. Running automatic calibration with the color and quality adjustment package The Creo server participates in the Konica Minolta Automatic Color Quality Adjustment Package procedure, which is not supported as a PDF, if required. 13. Run the calibration procedure again, and if the problem persists...
.... Place it as part of Black ramp tints. 12. Running automatic calibration with the color and quality adjustment package The Creo server participates in the Konica Minolta Automatic Color Quality Adjustment Package procedure, which is not supported as a PDF, if required. 13. Run the calibration procedure again, and if the problem persists...
IC-314 User Guide
Page 98
... or in file submission mode. 88 Chapter 7-Managing color IPDS and AFP color management Note: The IPDS and AFP workflows are available only with the Konica Minolta FD-5/FD-7 or FD-9 Note: You can override the CMOCA settings and make additional adjustments to the Color Management Object Content Architecture (CMOCA), as the...
... or in file submission mode. 88 Chapter 7-Managing color IPDS and AFP color management Note: The IPDS and AFP workflows are available only with the Konica Minolta FD-5/FD-7 or FD-9 Note: You can override the CMOCA settings and make additional adjustments to the Color Management Object Content Architecture (CMOCA), as the...
IC-314 User Guide
Page 99
... Using the i1iO Automated Scanning Table to measure a color chart and create a profile on page 93 Using the Konica Minolta FD‑9 spectrophotometer to measure a color chart and create a profile on page 95 Using the Konica Minolta FD-5/FD-7 spectrophotometer to measure a color chart and create a profile on page 100 Creating a profile from existing...
... Using the i1iO Automated Scanning Table to measure a color chart and create a profile on page 93 Using the Konica Minolta FD‑9 spectrophotometer to measure a color chart and create a profile on page 95 Using the Konica Minolta FD-5/FD-7 spectrophotometer to measure a color chart and create a profile on page 100 Creating a profile from existing...
IC-314 User Guide
Page 105
... ● The press must be calibrated. ● Make sure that the Profiling Tool automatically created based on the screening method. 18. Using the Konica Minolta FD‑9 spectrophotometer to save the measurement file and load it at a later time, locate a folder and in the Save in box, type a... name for the profile, or keep the name that your spectrophotometer is calibrated. Using the Konica Minolta FD‑9 spectrophotometer to the Profile Manager area in the Resource Center. 19. Click Create Profile. To define the location for saving the ...
... ● The press must be calibrated. ● Make sure that the Profiling Tool automatically created based on the screening method. 18. Using the Konica Minolta FD‑9 spectrophotometer to save the measurement file and load it at a later time, locate a folder and in the Save in box, type a... name for the profile, or keep the name that your spectrophotometer is calibrated. Using the Konica Minolta FD‑9 spectrophotometer to the Profile Manager area in the Resource Center. 19. Click Create Profile. To define the location for saving the ...
IC-314 User Guide
Page 110
... device until you hear a beep indicating that has the same pairing number as follows: 1. 100 Chapter 7-Managing color Using the Konica Minolta FD-5/FD-7 spectrophotometer to measure a color chart and create a profile Requirements: ● The press must already be calibrated. ● The... Konica Minolta FD-5/FD-7 spectrophotometer must be connected to the Target Mask. 3. Correctly set the device on the White Calibration plate that the calibration...
... device until you hear a beep indicating that has the same pairing number as follows: 1. 100 Chapter 7-Managing color Using the Konica Minolta FD-5/FD-7 spectrophotometer to measure a color chart and create a profile Requirements: ● The press must already be calibrated. ● The... Konica Minolta FD-5/FD-7 spectrophotometer must be connected to the Target Mask. 3. Correctly set the device on the White Calibration plate that the calibration...
IC-314 User Guide
Page 111
... chart. 3. d. Place the color measurement chart on the left side of the chart that you want to measure a color chart and create a profile using the Konica Minolta FD-5/FD-7 spectrophotometer. 1. Click Measure and perform the following actions: a. a. c.
... chart. 3. d. Place the color measurement chart on the left side of the chart that you want to measure a color chart and create a profile using the Konica Minolta FD-5/FD-7 spectrophotometer. 1. Click Measure and perform the following actions: a. a. c.
IC-314 User Guide
Page 125
... or failed. If the report indicates that the validation has failed, it . The Validation tool supports the following devices: ● Konica Minolta Intelligent Quality Optimizer ● Konica Minolta FD-9 spectrophotometer ● Konica Minolta FD-7 spectrophotometer ● Konica Minolta FD-5 spectrophotometer ● X-Rite i1 spectrophotometer ● X-Rite iSis spectrophotometer To achieve the best color match the print engine must...
... or failed. If the report indicates that the validation has failed, it . The Validation tool supports the following devices: ● Konica Minolta Intelligent Quality Optimizer ● Konica Minolta FD-9 spectrophotometer ● Konica Minolta FD-7 spectrophotometer ● Konica Minolta FD-5 spectrophotometer ● X-Rite i1 spectrophotometer ● X-Rite iSis spectrophotometer To achieve the best color match the print engine must...
IC-314 User Guide
Page 244
... of halftone text and graphics. Auto image adjustment-Activates the printer's Auto image adjustment feature for Position only or for example, bolded text. If the Konica Minolta Auto image inspection kit the Auto inspection mode drop-down list becomes available, enabling you can select from: ● Off: (Default) Apply no proof or...
... of halftone text and graphics. Auto image adjustment-Activates the printer's Auto image adjustment feature for Position only or for example, bolded text. If the Konica Minolta Auto image inspection kit the Auto inspection mode drop-down list becomes available, enabling you can select from: ● Off: (Default) Apply no proof or...