Page 1
... box in the cabinet through the flexible metal conduit. 30" (76.2 CM) AND 45" (114.3 cm) ELECTRIC DOWNDRAFT COOKTOP PRODUCT MODEL NUMBERS CUTOUT DIMENSIONS JED8130AD JED8230AD ELECTRICAL REQUIREMENTS: JED8345AD A B Before You Make the Electrical...;⁄₄" (55.3 cm) D. Connect a section of solid copper wire to the cooktop wiring box. Follow the electrical connector manufacturer's recommended procedure. Wall exhaust option 30" (76.2 cm) Cooktop B C 45" (114.3 cm) Cooktop C B A F D E A. Wiring box cover F. Installed dimension for it here. Grease ...
... box in the cabinet through the flexible metal conduit. 30" (76.2 CM) AND 45" (114.3 cm) ELECTRIC DOWNDRAFT COOKTOP PRODUCT MODEL NUMBERS CUTOUT DIMENSIONS JED8130AD JED8230AD ELECTRICAL REQUIREMENTS: JED8345AD A B Before You Make the Electrical...;⁄₄" (55.3 cm) D. Connect a section of solid copper wire to the cooktop wiring box. Follow the electrical connector manufacturer's recommended procedure. Wall exhaust option 30" (76.2 cm) Cooktop B C 45" (114.3 cm) Cooktop C B A F D E A. Wiring box cover F. Installed dimension for it here. Grease ...
Dimension Guide
Page 2
...and sidewall for planning purposes only. For complete details, see Installation our products, we reserve the right to clear the cooktop base. A. 30" (76.2 cm) on 30" (76.2 cm) models 45" (114.3 cm) on 45" (114.3 cm) models K. 2½" (6.4 cm) minimum distance ...wall. A minimum clearance of 2" (5.1 cm) is recommended to improve Dimensions are for maximum performance. Junction box or outlet; 12" (30.5 cm) minimum from upper cabinet to countertop within minimum horizontal clearances to change materials and specifications without notice. W10298937B 2/24/12 Installed ...
...and sidewall for planning purposes only. For complete details, see Installation our products, we reserve the right to clear the cooktop base. A. 30" (76.2 cm) on 30" (76.2 cm) models 45" (114.3 cm) on 45" (114.3 cm) models K. 2½" (6.4 cm) minimum distance ...wall. A minimum clearance of 2" (5.1 cm) is recommended to improve Dimensions are for maximum performance. Junction box or outlet; 12" (30.5 cm) minimum from upper cabinet to countertop within minimum horizontal clearances to change materials and specifications without notice. W10298937B 2/24/12 Installed ...
Installation Instruction
Page 1
... WARNING You can happen if the instructions are very important. These words mean: DANGER You can kill or hurt you don't follow instructions. 30" (76.2 CM) AND 45" (114.3 CM) ELECTRIC DOWNDRAFT COOKTOP INSTALLATION INSTRUCTIONS INSTRUCTIONS D'INSTALLATION DE LA TABLE DE CUISSON ÉLECTRIQUE ...AVEC ASPIRATION PAR LE BAS DE 30" (76,2 CM) ET 45" (114,3 CM) Table of injury, and tell you what the potential hazard is the safety alert symbol....
... WARNING You can happen if the instructions are very important. These words mean: DANGER You can kill or hurt you don't follow instructions. 30" (76.2 CM) AND 45" (114.3 CM) ELECTRIC DOWNDRAFT COOKTOP INSTALLATION INSTRUCTIONS INSTRUCTIONS D'INSTALLATION DE LA TABLE DE CUISSON ÉLECTRIQUE ...AVEC ASPIRATION PAR LE BAS DE 30" (76,2 CM) ET 45" (114,3 CM) Table of injury, and tell you what the potential hazard is the safety alert symbol....
Installation Instruction
Page 2
... cm) trade-size metal-clad conduit ■ UL listed wire connectors ■ Metal ducting ■ Jenn-Air wall cap Jenn-Air® 6" (15.2 cm) Round Surface Wall Cap Damper Order Part Number A406 Jenn-Air® 3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper Order Part Number A403... need to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of cookop) B. 30" (76.2 cm) C. 21³⁄₄" (55.3 cm) D. Blower G B A* C C H F D** E A. 6¹⁄₄" (15.9 cm) B. 3¹⁄₂...
... cm) trade-size metal-clad conduit ■ UL listed wire connectors ■ Metal ducting ■ Jenn-Air wall cap Jenn-Air® 6" (15.2 cm) Round Surface Wall Cap Damper Order Part Number A406 Jenn-Air® 3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper Order Part Number A403... need to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of cookop) B. 30" (76.2 cm) C. 21³⁄₄" (55.3 cm) D. Blower G B A* C C H F D** E A. 6¹⁄₄" (15.9 cm) B. 3¹⁄₂...
Installation Instruction
Page 3
... (25.4 cm) from upper cabinet to countertop within minimum horizontal clearances to nearest left and right side combustible surface above ) C. 30" (76.2 cm) minimum clearance between the motor/blower and cabinet for the grease containers is 5¹⁄₂" (14.0 cm...). **A minimum clearance of 2" (5.1 cm) is covered by dashed box above cooktop L. 1½" (3.8 cm) minimum clearance between back wall and countertop 3 A. 30" (76.2 cm) on 30" (76.2 cm) models 45" (114.3 cm) on each side of countertop I K J G B A* C D** C H F E A. 6¹⁄₄" (15...
... (25.4 cm) from upper cabinet to countertop within minimum horizontal clearances to nearest left and right side combustible surface above ) C. 30" (76.2 cm) minimum clearance between the motor/blower and cabinet for the grease containers is 5¹⁄₂" (14.0 cm...). **A minimum clearance of 2" (5.1 cm) is covered by dashed box above cooktop L. 1½" (3.8 cm) minimum clearance between back wall and countertop 3 A. 30" (76.2 cm) on 30" (76.2 cm) models 45" (114.3 cm) on each side of countertop I K J G B A* C D** C H F E A. 6¹⁄₄" (15...
Installation Instruction
Page 4
...of cooktop F. Wall exhaust option Venting Requirements ■ Do not terminate the vent system in the vent system. ■ Use caulking to 30-gauge galvanized steel or 26-gauge aluminized steel if allowed by local codes. Rigid metal vent is not recommended. If roof or wall cap has...8324;" x 10" (8.3 x 25.4 cm) elbow transition. ■ Use vent clamps to seal all joints in an attic or other enclosed area. ■ Use a Jenn-Air® vent cap. ■ Vent system must terminate to clear the cooktop base. A minimum clearance of 1" (2.5 cm) is recommended to the sidewalls and a ³...
...of cooktop F. Wall exhaust option Venting Requirements ■ Do not terminate the vent system in the vent system. ■ Use caulking to 30-gauge galvanized steel or 26-gauge aluminized steel if allowed by local codes. Rigid metal vent is not recommended. If roof or wall cap has...8324;" x 10" (8.3 x 25.4 cm) elbow transition. ■ Use vent clamps to seal all joints in an attic or other enclosed area. ■ Use a Jenn-Air® vent cap. ■ Vent system must terminate to clear the cooktop base. A minimum clearance of 1" (2.5 cm) is recommended to the sidewalls and a ³...
Installation Instruction
Page 6
... round metal vent C. 16" (40.6 cm) maximum D. 6" (15.2 cm) round PVC sewer pipe E. 5" to 6" (12.7 cm to 15.2 cm) 1 ft transition (0.3 m) 6 L. 30 ft (9.1 m) max. Concrete slab I . 6" (15.2 cm) round 90° PVC sewer pipe elbow J. Window well Concrete Slab Installations - Tightly pack gravel or sand completely around... pipe. M. 6" (15.2 cm) round 90° PVC sewer pipe elbow N. 6" (15.2 cm) round PVC coupling O. 12" (30.5 cm) minimum Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used...
... round metal vent C. 16" (40.6 cm) maximum D. 6" (15.2 cm) round PVC sewer pipe E. 5" to 6" (12.7 cm to 15.2 cm) 1 ft transition (0.3 m) 6 L. 30 ft (9.1 m) max. Concrete slab I . 6" (15.2 cm) round 90° PVC sewer pipe elbow J. Window well Concrete Slab Installations - Tightly pack gravel or sand completely around... pipe. M. 6" (15.2 cm) round 90° PVC sewer pipe elbow N. 6" (15.2 cm) round PVC coupling O. 12" (30.5 cm) minimum Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used...
Installation Instruction
Page 7
... D. Using 2 or more people to the blower exhaust scroll. 2 ft (0.6 m) 1- 90° elbow 8 ft (2.4 m) straight 1 - Flexible vent creates back pressure and air turbulence that attach the blower motor assembly to do so can result in the low range for shorter lengths; If the equivalent duct length exceeds... 30 ft (9.1 m), it is shipped from the blower exhaust scroll (E). 4. Failure to high range. Reattach the four acorn nuts to secure ...
... D. Using 2 or more people to the blower exhaust scroll. 2 ft (0.6 m) 1- 90° elbow 8 ft (2.4 m) straight 1 - Flexible vent creates back pressure and air turbulence that attach the blower motor assembly to do so can result in the low range for shorter lengths; If the equivalent duct length exceeds... 30 ft (9.1 m), it is shipped from the blower exhaust scroll (E). 4. Failure to high range. Reattach the four acorn nuts to secure ...
Installation Instruction
Page 8
... phase, 120/240 volt, 60 Hz., AC only electrical supply is required on a separate, 40-amp circuit (45" [114.3 cm] models) or 40-amp circuit (30" [76.2 cm] models), fused on each end of the line. ■ The cooktop should be connected directly to the cooktop wiring box. ■ Locate the...
... phase, 120/240 volt, 60 Hz., AC only electrical supply is required on a separate, 40-amp circuit (45" [114.3 cm] models) or 40-amp circuit (30" [76.2 cm] models), fused on each end of the line. ■ The cooktop should be connected directly to the cooktop wiring box. ■ Locate the...
Use and Care
Page 1
.... Table of Contents/Table des matières 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. JENN-AIR® 30" AND 45" (76.2 CM AND 114.3 CM) ELECTRIC DOWNDRAFT COOKTOP TABLE DE CUISSON RADIANTE À ASPIRATION PAR LE BAS JENN-AIR® DE 30" ET 45" (76,2 CM ET 114,3 CM) Use & Care Guide For questions about features...
.... Table of Contents/Table des matières 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. JENN-AIR® 30" AND 45" (76.2 CM AND 114.3 CM) ELECTRIC DOWNDRAFT COOKTOP TABLE DE CUISSON RADIANTE À ASPIRATION PAR LE BAS JENN-AIR® DE 30" ET 45" (76,2 CM ET 114,3 CM) Use & Care Guide For questions about features...
Use and Care
Page 4
...HG F ED A. Left front element control knob J. The cooktop you have some or all controls when done cooking. Cooktop cartridge D. Left rear element control knob 30" (76.2 cm) JED8230 Cooktop Layout and Features A B C HG F E D A. Exhaust fan vent grille C. Med. Hi ■ Hold a ...knob G. Left rear element control knob 45" (114.3 cm) JED8345 Cooktop Layout and Features A B C Fire Hazard Turn off all of the items listed. 30" (76.2 cm) JED8130 Cooktop Layout and Features A B C COOKTOP USE Cooktop Controls WARNING HG F E D A. Medium ■ Maintain a slow boil....
...HG F ED A. Left front element control knob J. The cooktop you have some or all controls when done cooking. Cooktop cartridge D. Left rear element control knob 30" (76.2 cm) JED8230 Cooktop Layout and Features A B C HG F E D A. Exhaust fan vent grille C. Med. Hi ■ Hold a ...knob G. Left rear element control knob 45" (114.3 cm) JED8345 Cooktop Layout and Features A B C Fire Hazard Turn off all of the items listed. 30" (76.2 cm) JED8130 Cooktop Layout and Features A B C COOKTOP USE Cooktop Controls WARNING HG F E D A. Medium ■ Maintain a slow boil....
Use and Care
Page 12
...YEAR LIMITED WARRANTY ON CERTAIN COMPONENT PARTS In the second through fifth years from the date of purchase, when this appliance is contrary to Jenn-Air within 30 days from the date of purchase. 6. Repairs when your major appliance. Any food loss due to the appliance. 9. The removal and... reinstallation of your major appliance is located in a remote area where service by a Jenn-Air designated service company. If outside the 50 United States and Canada,...
...YEAR LIMITED WARRANTY ON CERTAIN COMPONENT PARTS In the second through fifth years from the date of purchase, when this appliance is contrary to Jenn-Air within 30 days from the date of purchase. 6. Repairs when your major appliance. Any food loss due to the appliance. 9. The removal and... reinstallation of your major appliance is located in a remote area where service by a Jenn-Air designated service company. If outside the 50 United States and Canada,...
Warranty
Page 1
... through fifth years from the date of purchase, when this information on the model and serial number label located on how to Jenn-Air within 30 days from the date of purchase. 6. Repairs when your major appliance is used in the country in a manner that have been...in -warranty service. The removal and reinstallation of your major appliance. Service must provide proof of Whirlpool Corporation or Whirlpool Canada LP (hereafter "Jenn-Air") will need it was purchased. DISCLAIMER OF IMPLIED WARRANTIES; In the U.S.A., call 1-800-807-6777. 6/09 Keep this limited warranty does...
... through fifth years from the date of purchase, when this information on the model and serial number label located on how to Jenn-Air within 30 days from the date of purchase. 6. Repairs when your major appliance is used in the country in a manner that have been...in -warranty service. The removal and reinstallation of your major appliance. Service must provide proof of Whirlpool Corporation or Whirlpool Canada LP (hereafter "Jenn-Air") will need it was purchased. DISCLAIMER OF IMPLIED WARRANTIES; In the U.S.A., call 1-800-807-6777. 6/09 Keep this limited warranty does...
CAD
Page 1
n 0 w z O a 2 FRONT ELEVATION 3 SIDE ELEVATION [Manufacturer: Jenn-Air Model Number: JED8230ADS RENNAIR® Date: MM/DD/YY Scale: Iv - 11 0" A II II row OGD 1 PLAN NOTE: Dimensional information is provided for planning purposes only. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved. Do not make any cutouts based on this information. Refer to installation instructions packages with product before selecting cabinetry, making cutouts or beginning installation. 29 n CUTOUT DIM. 30" APPLIANCE DIM.
n 0 w z O a 2 FRONT ELEVATION 3 SIDE ELEVATION [Manufacturer: Jenn-Air Model Number: JED8230ADS RENNAIR® Date: MM/DD/YY Scale: Iv - 11 0" A II II row OGD 1 PLAN NOTE: Dimensional information is provided for planning purposes only. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved. Do not make any cutouts based on this information. Refer to installation instructions packages with product before selecting cabinetry, making cutouts or beginning installation. 29 n CUTOUT DIM. 30" APPLIANCE DIM.