Owners Manual 3
Page 13
... have not been designed or tested as a weight training apparatus, Invacare shall not be liable for protection against possible shock hazards and fire. Part No. 1148076 13 Pronto® M51™ Base with the National Electrical Code. DO NOT use the wheelchair if the joystick boot is the... connected. This provides the end user or his /her assistant sufficient time to prematurely rust or may damage the upholstery. Weight Training Invacare does not recommend the use only a three‐wire extension cord having the same or higher electrical rating as a weight training apparatus...
... have not been designed or tested as a weight training apparatus, Invacare shall not be liable for protection against possible shock hazards and fire. Part No. 1148076 13 Pronto® M51™ Base with the National Electrical Code. DO NOT use the wheelchair if the joystick boot is the... connected. This provides the end user or his /her assistant sufficient time to prematurely rust or may damage the upholstery. Weight Training Invacare does not recommend the use only a three‐wire extension cord having the same or higher electrical rating as a weight training apparatus...
Owners Manual 3
Page 23
...10065; Ensure no excessive drag or pull to the Electronics Manual supplied with SureStep® Part No. 1148076 23 Pronto® M51™ Base with each wheelchair. Replace if necessary. ❑ Ensure wheelchair rolls straight (no excessive side movement or binding occurs...on the wheelchair. ❑ Ensure casters are free of debris. Troubleshooting Guide NOTE: For additional troubleshooting information and explanation of error codes, refer to one side). ❑ Inspect charger AC power cord for damage. SECTION 4-SAFETY INSPECTION/TROUBLESHOOTING Inspect/Adjust Weekly ❑...
...10065; Ensure no excessive drag or pull to the Electronics Manual supplied with SureStep® Part No. 1148076 23 Pronto® M51™ Base with each wheelchair. Replace if necessary. ❑ Ensure wheelchair rolls straight (no excessive side movement or binding occurs...on the wheelchair. ❑ Ensure casters are free of debris. Troubleshooting Guide NOTE: For additional troubleshooting information and explanation of error codes, refer to one side). ❑ Inspect charger AC power cord for damage. SECTION 4-SAFETY INSPECTION/TROUBLESHOOTING Inspect/Adjust Weekly ❑...
Owners Manual 3
Page 26
... PLUGGED IN displays. Pronto® M51™ Base with SureStep® 26 Part No. 1148076 Refer to Replacing Batteries on . Contact Invacare/Dealer for service. Wrong type of the reverse, forward, left or right limits (Error codes E01, E02, E03 or E04)....the wheelchair does not drive. Check that battery cables are connected properly. Contact Invacare/Dealer for service. Contact Invacare/Dealer for service. Contact Invacare/Dealer for service. Battery charger connected (Error code E28). ƽ SPM Battery Fault displays and the Batteries need to charge...
... PLUGGED IN displays. Pronto® M51™ Base with SureStep® 26 Part No. 1148076 Refer to Replacing Batteries on . Contact Invacare/Dealer for service. Wrong type of the reverse, forward, left or right limits (Error codes E01, E02, E03 or E04)....the wheelchair does not drive. Check that battery cables are connected properly. Contact Invacare/Dealer for service. Contact Invacare/Dealer for service. Contact Invacare/Dealer for service. Battery charger connected (Error code E28). ƽ SPM Battery Fault displays and the Batteries need to charge...
Owners Manual 3
Page 27
... 55. Poor battery terminal connection. Have terminals cleaned. Part No. 1148076 27 Pronto® M51™ Base with the control module (Error code E200). Recalibrate the joystick (joystick throw procedure). Replace the controller if necessary. The Proportional or... malfunction. PROBABLE CAUSE The joystick neutral test has failed (Error code E18). fault during a previous turn-off - Battery failure. Contact Dealer/Invacare for Service. Batteries not charged. Contact Dealer/Invacare for service. Electrical malfunction. even after recharging. SOLUTIONS Release the...
... 55. Poor battery terminal connection. Have terminals cleaned. Part No. 1148076 27 Pronto® M51™ Base with the control module (Error code E200). Recalibrate the joystick (joystick throw procedure). Replace the controller if necessary. The Proportional or... malfunction. PROBABLE CAUSE The joystick neutral test has failed (Error code E18). fault during a previous turn-off - Battery failure. Contact Dealer/Invacare for Service. Batteries not charged. Contact Dealer/Invacare for service. Electrical malfunction. even after recharging. SOLUTIONS Release the...
Owners Manual 3
Page 32
..., is charging. Charger/Programming Input The charger/programming input is pushed from the upright (neutral) position, the faster the wheelchair or seat moves. Pronto® M51™ Base with SureStep® 32 Part No. 1148076 To adjust the speed, perform one of the following steps: i. The smaller bars in 20% Increments..., simply release the joystick. Joystick The joystick has proportional drive control, meaning that the further the joystick is located at the front of the flash codes and what they indicate. Service Indicator The AMBER service indicator will light.
..., is charging. Charger/Programming Input The charger/programming input is pushed from the upright (neutral) position, the faster the wheelchair or seat moves. Pronto® M51™ Base with SureStep® 32 Part No. 1148076 To adjust the speed, perform one of the following steps: i. The smaller bars in 20% Increments..., simply release the joystick. Joystick The joystick has proportional drive control, meaning that the further the joystick is located at the front of the flash codes and what they indicate. Service Indicator The AMBER service indicator will light.