Owners Manual
Page 1
For more information regarding Invacare products, parts, and services, please visit www.invacare.com User: Before using this product, read this manual and save for future reference. Operator's Manual Platinum™ Series XL, 5, 10 Oxygen Concentrators Standard, with SensO2®and HomeFill® Invacare 5 with SensO2 Model IRC5LXO2 Invacare 10 with SensO2 Model IRC10LXO2 Invacare 5 Model IRC5LX Invacare 10 Model IRC10LX Dealer: This manual MUST be given to the end user.
For more information regarding Invacare products, parts, and services, please visit www.invacare.com User: Before using this product, read this manual and save for future reference. Operator's Manual Platinum™ Series XL, 5, 10 Oxygen Concentrators Standard, with SensO2®and HomeFill® Invacare 5 with SensO2 Model IRC5LXO2 Invacare 10 with SensO2 Model IRC10LXO2 Invacare 5 Model IRC5LX Invacare 10 Model IRC10LX Dealer: This manual MUST be given to the end user.
Owners Manual
Page 2
... maintenance, and cleaning. Platinum™ Series 2 Part No 1118353 Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer ...or technical personnel before attempting to use this equipment ‐ otherwise, injury or damage may occur. ƽ ACCESSORIES WARNING Invacare products are many different types of these instructions and any available optional equipment without first completely reading and understanding these devices ...
... maintenance, and cleaning. Platinum™ Series 2 Part No 1118353 Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer ...or technical personnel before attempting to use this equipment ‐ otherwise, injury or damage may occur. ƽ ACCESSORIES WARNING Invacare products are many different types of these instructions and any available optional equipment without first completely reading and understanding these devices ...
Owners Manual
Page 3
Units without SensO2 22 Initial Startup of Burns, Electrocution, Fire or Injury to Persons 8 Operating Information 9 Radio Frequency Interference 9 SECTION 2-FEATURES 11 SECTION 3-HANDLING 12 Unpacking 12 Inspection 12 Storage 12 SECTION 4-TYPICAL PRODUCT PARAMETERS 13 SECTION 5-OPERATING INSTRUCTIONS ....... 16 Introduction 16 Select a Location 16 Set-Up 17 Plug in Power Cord 17 Connect Humidifier (If So Prescribed 17 Power Switch 19 Flowrate 20 Front Panel Indicators - TABLE OF CONTENTS TABLE OF CONTENTS ACCESSORIES 2 REGISTER YOUR PRODUCT 4 SPECIAL NOTES 5 LABEL ...
Units without SensO2 22 Initial Startup of Burns, Electrocution, Fire or Injury to Persons 8 Operating Information 9 Radio Frequency Interference 9 SECTION 2-FEATURES 11 SECTION 3-HANDLING 12 Unpacking 12 Inspection 12 Storage 12 SECTION 4-TYPICAL PRODUCT PARAMETERS 13 SECTION 5-OPERATING INSTRUCTIONS ....... 16 Introduction 16 Select a Location 16 Set-Up 17 Plug in Power Cord 17 Connect Humidifier (If So Prescribed 17 Power Switch 19 Flowrate 20 Front Panel Indicators - TABLE OF CONTENTS TABLE OF CONTENTS ACCESSORIES 2 REGISTER YOUR PRODUCT 4 SPECIAL NOTES 5 LABEL ...
Owners Manual
Page 4
Any registration information you submit will only be used by Invacare Corporation and protected as required by applicable laws and regulations. Safeguarding your registration. TABLE OF CONTENTS TABLE OF CONTENTS SECTION 6-MAINTENANCE 23 ...the Humidifier 24 SECTION 7-TROUBLESHOOTING GUIDE ......... 26 NOTES 28 LIMITED WARRANTY 30 REGISTER YOUR PRODUCT The benefits of your product. 3. Register ONLINE at warranty.invacare.com Please have your model number and purchase date available to complete your investment. 2. Platinum™ Series 4 Part No 1118353 Ensuring long-term ...
Any registration information you submit will only be used by Invacare Corporation and protected as required by applicable laws and regulations. Safeguarding your registration. TABLE OF CONTENTS TABLE OF CONTENTS SECTION 6-MAINTENANCE 23 ...the Humidifier 24 SECTION 7-TROUBLESHOOTING GUIDE ......... 26 NOTES 28 LIMITED WARRANTY 30 REGISTER YOUR PRODUCT The benefits of your product. 3. Register ONLINE at warranty.invacare.com Please have your model number and purchase date available to complete your investment. 2. Platinum™ Series 4 Part No 1118353 Ensuring long-term ...
Owners Manual
Page 5
Failure to the following table for definitions of the room in which , if not avoided, could result in personal injury or property damage. SIGNAL WORD DANGER WARNING CAUTION MEANING Danger indicates an imminently hazardous situation which , if not avoided, may result in property damage or minor injury or both. NOTICE The information contained in this device. Textiles and other sources of ignition out of the signal words. Caution indicates a potentially hazardous situation which , if not avoided, will result in death or serious injury. Keep all matches, lighted cigarettes ...
Failure to the following table for definitions of the room in which , if not avoided, could result in personal injury or property damage. SIGNAL WORD DANGER WARNING CAUTION MEANING Danger indicates an imminently hazardous situation which , if not avoided, may result in property damage or minor injury or both. NOTICE The information contained in this device. Textiles and other sources of ignition out of the signal words. Caution indicates a potentially hazardous situation which , if not avoided, will result in death or serious injury. Keep all matches, lighted cigarettes ...
Owners Manual
Page 6
... order of a physician, or any other practitioner licensed by the law of the State in the event of a power outage, alarm condition or mechanical failure. Invacare recommends an alternate source of supplemental oxygen in which he/she practices to be used as an oxygen supplement and is not considered life supporting...
... order of a physician, or any other practitioner licensed by the law of the State in the event of a power outage, alarm condition or mechanical failure. Invacare recommends an alternate source of supplemental oxygen in which he/she practices to be used as an oxygen supplement and is not considered life supporting...
Owners Manual
Page 7
LABEL LOCATION LABEL LOCATION IRC5LX and IRC10LX HomeFill II Compatible Operating Instructions (See Operator's Manual) Alarms (See Operator's Manual) I/O WARNING - CAUTION - Refer servicing to qualified service personnel. Keep ALL sources ...
LABEL LOCATION LABEL LOCATION IRC5LX and IRC10LX HomeFill II Compatible Operating Instructions (See Operator's Manual) Alarms (See Operator's Manual) I/O WARNING - CAUTION - Refer servicing to qualified service personnel. Keep ALL sources ...
Owners Manual
Page 8
DO NOT come in another room at least 7 ft from static electricity created by Invacare. DO NOT place or store product where it has been dropped or damaged, or dropped into water, call qualified technician for examination and repair. If ...
DO NOT come in another room at least 7 ft from static electricity created by Invacare. DO NOT place or store product where it has been dropped or damaged, or dropped into water, call qualified technician for examination and repair. If ...
Owners Manual
Page 9
Invacare recommends that each concentrator be on the power cord. Additional monitoring or attention may be required for patients using this device who are unable to ... move or relocate concentrator by IEC/EN 60601‐1‐2. Shorter periods of 30 minutes at a time. SECTION 1-GENERAL GUIDELINES Operating Information For optimum performance, Invacare recommends that Crush‐Proof oxygen tubing be used near children or physically‐challenged individuals.
Invacare recommends that each concentrator be on the power cord. Additional monitoring or attention may be required for patients using this device who are unable to ... move or relocate concentrator by IEC/EN 60601‐1‐2. Shorter periods of 30 minutes at a time. SECTION 1-GENERAL GUIDELINES Operating Information For optimum performance, Invacare recommends that Crush‐Proof oxygen tubing be used near children or physically‐challenged individuals.
Owners Manual
Page 10
To determine if the emissions from the Platinum is connected. Platinum™ Series 10 Part No 1118353 In such rare cases, interference may experience interference from even the low levels of electromagnetic emissions permitted by one of the following measures: • Reposition, relocate, or increase the separation between the equipment. Connect the equipment into an outlet on a circuit different from that to which the other device(s) stops, then the Platinum is causing the interference. If the interference with the other device(s) is causing the interference, turn the Platinum ...
To determine if the emissions from the Platinum is connected. Platinum™ Series 10 Part No 1118353 In such rare cases, interference may experience interference from even the low levels of electromagnetic emissions permitted by one of the following measures: • Reposition, relocate, or increase the separation between the equipment. Connect the equipment into an outlet on a circuit different from that to which the other device(s) stops, then the Platinum is causing the interference. If the interference with the other device(s) is causing the interference, turn the Platinum ...
Owners Manual
Page 11
For more information about the HomeFill, contact your Invacare dealer. When not in use, the plug provided with the HomeFill home oxygen compressor. IOH200 Power Cord Outlet Fitting NOTE: This outlet fitting is to ...
For more information about the HomeFill, contact your Invacare dealer. When not in use, the plug provided with the HomeFill home oxygen compressor. IOH200 Power Cord Outlet Fitting NOTE: This outlet fitting is to ...
Owners Manual
Page 12
Check for any obvious damage to FIGURE 3.1. 1. Remove all the components from the carton. Carefully remove all loose packing from Invacare. DO NOT place objects on top of the oxygen concentrator for storage until use of the concentrator is to be used immediately, retain containers and ...
Check for any obvious damage to FIGURE 3.1. 1. Remove all the components from the carton. Carefully remove all loose packing from Invacare. DO NOT place objects on top of the oxygen concentrator for storage until use of the concentrator is to be used immediately, retain containers and ...
Owners Manual
Page 13
Up to 13,129 ft (4000 meters) below 90% efficiency Platinum 10 - From 4,000 ft (1230 meters) to 4,000 ft (1230 meters) above sea level without degradation of concentration levels. From 6,000 ft (1828 meters) to 13,129 ft (4000 meters) below 90% efficiency *Oxygen Output Concentration Levels: All 5LXO2/5LX models 87% to 95.6% for flows ranging 0.5 to 5 L/min and all 10LXO2/10LX models 87% to 95.6% for flows ranging 2 L to 6,000 ft (1828 meters) above sea level without degradation of concentration levels. SECTION 4-TYPICAL PRODUCT PARAMETERS SECTION 4-TYPICAL PRODUCT PARAMETERS...
Up to 13,129 ft (4000 meters) below 90% efficiency Platinum 10 - From 4,000 ft (1230 meters) to 4,000 ft (1230 meters) above sea level without degradation of concentration levels. From 6,000 ft (1828 meters) to 13,129 ft (4000 meters) below 90% efficiency *Oxygen Output Concentration Levels: All 5LXO2/5LX models 87% to 95.6% for flows ranging 0.5 to 5 L/min and all 10LXO2/10LX models 87% to 95.6% for flows ranging 2 L to 6,000 ft (1828 meters) above sea level without degradation of concentration levels. SECTION 4-TYPICAL PRODUCT PARAMETERS SECTION 4-TYPICAL PRODUCT PARAMETERS...
Owners Manual
Page 14
...; 3/8 in (46.7 cm ± 1 cm) 26 3/8 in ± 3/8 in (67.0 cm ± 1 cm) 14 3/8 in ± 3/8 in maximum recommended flow when back pressure of the Invacare Pediatric Flowmeter IRCPF16 Accessory. Platinum 10 - 2 L/min to 10 L/min Platinum 5 - 0 L/min to 0.5 L/min, Platinum 10 - 0 L/min to 5 L/min For flowrates less than 1 L/min, we...
...; 3/8 in (46.7 cm ± 1 cm) 26 3/8 in ± 3/8 in (67.0 cm ± 1 cm) 14 3/8 in ± 3/8 in maximum recommended flow when back pressure of the Invacare Pediatric Flowmeter IRCPF16 Accessory. Platinum 10 - 2 L/min to 10 L/min Platinum 5 - 0 L/min to 0.5 L/min, Platinum 10 - 0 L/min to 5 L/min For flowrates less than 1 L/min, we...
Owners Manual
Page 15
SECTION 4-TYPICAL PRODUCT PARAMETERS Operating Ambient Temperature: Exhaust: Oxygen Output Temperature: Cabinet: Regulatory Listing: Electrical: Placement: Tubing: Relative Humidity: Time of Crush-Proof Tubing (DO NOT pinch). No closer than three inches from any wall, furniture, draperies, or similar surfaces. 7 ft cannula with high flow cannula at 20-60% relative humidity Platinum 5 and XL: Less than Ambient + 8°F (+4.4°C) Impact Resistant flame-retardant plastic cabinet that conforms to UL 94-V0 Double Insulated Product ETL certified complying with UL 1097 ETL certified to ...
SECTION 4-TYPICAL PRODUCT PARAMETERS Operating Ambient Temperature: Exhaust: Oxygen Output Temperature: Cabinet: Regulatory Listing: Electrical: Placement: Tubing: Relative Humidity: Time of Crush-Proof Tubing (DO NOT pinch). No closer than three inches from any wall, furniture, draperies, or similar surfaces. 7 ft cannula with high flow cannula at 20-60% relative humidity Platinum 5 and XL: Less than Ambient + 8°F (+4.4°C) Impact Resistant flame-retardant plastic cabinet that conforms to UL 94-V0 Double Insulated Product ETL certified complying with UL 1097 ETL certified to ...
Owners Manual
Page 16
He/She should be blocked. Keep unit at least 3 inches away from walls, draperies, furniture, and the like . You may be located in a closet. Platinum™ Series 16 Part No 1118353 This owner's manual will tell you about your concentrator and will show you use your oxygen concentrator. Select a Location ƽ WARNING NEVER block the air openings of the product or place it on its casters. The air intake of the unit should be most convenient. Clinical studies have documented that separates oxygen from room air. It provides high concentration of oxygen ...
He/She should be blocked. Keep unit at least 3 inches away from walls, draperies, furniture, and the like . You may be located in a closet. Platinum™ Series 16 Part No 1118353 This owner's manual will tell you about your concentrator and will show you use your oxygen concentrator. Select a Location ƽ WARNING NEVER block the air openings of the product or place it on its casters. The air intake of the unit should be most convenient. Clinical studies have documented that separates oxygen from room air. It provides high concentration of oxygen ...
Owners Manual
Page 17
... Humidifier (If So Prescribed) ƽ WARNING DO NOT overfill humidifier. DO NOT reverse the oxygen input and output connections. For Platinum 10, recommended humidifiers are : Invacare 3260, 003‐40, or 006‐40. This plug will travel through the cannula back to the level indicated by the manufacturer. 2. If the...
... Humidifier (If So Prescribed) ƽ WARNING DO NOT overfill humidifier. DO NOT reverse the oxygen input and output connections. For Platinum 10, recommended humidifiers are : Invacare 3260, 003‐40, or 006‐40. This plug will travel through the cannula back to the level indicated by the manufacturer. 2. If the...
Owners Manual
Page 18
Refer to the inlet filter. The humidifier adapter is securely fastened. Remove the filter access door located on the side of the filter access door and gently pry the filter access door open. Pull up and remove the humidifier bottle adapter. Place the humidifier bottle in FIGURE 5.3. 6. Plate Groove (Insert Flat Head Screwdriver Here) Filter Access Door DETAIL "A" DETAIL "B" Humidifier Bottle Adapter DETAIL "C" Filter Access Door Humidifier Bottle Adapter FIGURE 5.3 Attaching the Humidifier Bottle Adapter Platinum™ Series 18 Part No 1118353 Insert a flathead ...
Refer to the inlet filter. The humidifier adapter is securely fastened. Remove the filter access door located on the side of the filter access door and gently pry the filter access door open. Pull up and remove the humidifier bottle adapter. Place the humidifier bottle in FIGURE 5.3. 6. Plate Groove (Insert Flat Head Screwdriver Here) Filter Access Door DETAIL "A" DETAIL "B" Humidifier Bottle Adapter DETAIL "C" Filter Access Door Humidifier Bottle Adapter FIGURE 5.3 Attaching the Humidifier Bottle Adapter Platinum™ Series 18 Part No 1118353 Insert a flathead ...
Owners Manual
Page 19
Attach the cannula/patient supply tubing to FIGURE 5.5 on for one second, indicating that oxygen is functioning properly. Press power switch to oxygen outlet connector on position. On/Off (I/O) Power Switch FIGURE 5.5 Power Switch Part No 1118353 19 Platinum™ Series SECTION 5-OPERATING INSTRUCTIONS 7. Attach oxygen tubing from the humidifier bottle to on the oxygen concentrator (FIGURE 5.4). 8. All the panel lights and the audible alarm will come on page 19. 1. After assembly, ensure that the unit is flowing through the cannula. Oxygen Tubing Oxygen Outlet ...
Attach the cannula/patient supply tubing to FIGURE 5.5 on for one second, indicating that oxygen is functioning properly. Press power switch to oxygen outlet connector on position. On/Off (I/O) Power Switch FIGURE 5.5 Power Switch Part No 1118353 19 Platinum™ Series SECTION 5-OPERATING INSTRUCTIONS 7. Attach oxygen tubing from the humidifier bottle to on the oxygen concentrator (FIGURE 5.4). 8. All the panel lights and the audible alarm will come on page 19. 1. After assembly, ensure that the unit is flowing through the cannula. Oxygen Tubing Oxygen Outlet ...
Owners Manual
Page 20
If the flowrate on the flowmeter unless a change the L/min setting on the flowmeter ever falls below 0.5 L/min for Platinum 5 (1 L/min for Platinum 10) for more than about one minute, the LOW FLOW alarm will go off. After rated flow is a rapid beeping of some accessories such as the pediatric flowstand and the HomeFill compressor will deactivate the Low Flow Alarm. Never set the flow greater than 10L/min on the IRC10. ƽ WARNING DO NOT change has been prescribed by your physician or therapist. Next, turn the flow knob until the ball rises to the line. Flow Knob ...
If the flowrate on the flowmeter unless a change the L/min setting on the flowmeter ever falls below 0.5 L/min for Platinum 5 (1 L/min for Platinum 10) for more than about one minute, the LOW FLOW alarm will go off. After rated flow is a rapid beeping of some accessories such as the pediatric flowstand and the HomeFill compressor will deactivate the Low Flow Alarm. Never set the flow greater than 10L/min on the IRC10. ƽ WARNING DO NOT change has been prescribed by your physician or therapist. Next, turn the flow knob until the ball rises to the line. Flow Knob ...