Owners Manual
Page 1
Invacare® Homecare Beds 5411IVC, 5410IVC, 5311IVC, 5310IVC, 5307IVC, 5411LowIVC, 5410LowIVC en User Manual This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.
Invacare® Homecare Beds 5411IVC, 5410IVC, 5311IVC, 5310IVC, 5307IVC, 5411LowIVC, 5410LowIVC en User Manual This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.
Owners Manual
Page 3
... the Casters 23 4.8 Assembling the Universal Bed Ends 24 4.9 Installing Low Bed Ends 25 4.9.1 Installing the Casters onto the Low Bed Ends 25 4.10 Assembling/Installing/Removing Drive Shaft 26 4.11 Inspecting the Bed 27 4.11.1 Installing/Removing Cable Lock ... Installing/Removing the Pendant 30 4.12 Storing the Bed 30 5 Operation 31 5.1 Bed Operation and Component Overview 31 5.2 Operating Full Electric Bed 33 5.3 Operating the Semi-Electric Bed 34 5.3.1 Using the Emergency Crank 35 5.4 Operating the Manual Bed 36 5.5 Optional Bed Rails 36 6 Maintenance 38 6.1 Service Life 38...
... the Casters 23 4.8 Assembling the Universal Bed Ends 24 4.9 Installing Low Bed Ends 25 4.9.1 Installing the Casters onto the Low Bed Ends 25 4.10 Assembling/Installing/Removing Drive Shaft 26 4.11 Inspecting the Bed 27 4.11.1 Installing/Removing Cable Lock ... Installing/Removing the Pendant 30 4.12 Storing the Bed 30 5 Operation 31 5.1 Bed Operation and Component Overview 31 5.2 Operating Full Electric Bed 33 5.3 Operating the Semi-Electric Bed 34 5.3.1 Using the Emergency Crank 35 5.4 Operating the Manual Bed 36 5.5 Optional Bed Rails 36 6 Maintenance 38 6.1 Service Life 38...
Owners Manual
Page 4
...avoided, will result in death or serious injury. Gives useful tips, recommendations and information for efficient, trouble-free use. 1.2 Intended Use The bed is intended to be used in home care and long term care facilities. 4 1114836-H-05 WARNING! - Refer to provide different positions for... definitions of the signal words. Invacare® Homecare Beds 1 General 1.1 Symbols Signal words are used in this manual and apply to hazards or unsafe practices which , if not avoided, ...
...avoided, will result in death or serious injury. Gives useful tips, recommendations and information for efficient, trouble-free use. 1.2 Intended Use The bed is intended to be used in home care and long term care facilities. 4 1114836-H-05 WARNING! - Refer to provide different positions for... definitions of the signal words. Invacare® Homecare Beds 1 General 1.1 Symbols Signal words are used in this manual and apply to hazards or unsafe practices which , if not avoided, ...
Owners Manual
Page 5
... Full Electric 5410IVC, 5411IVC SHIPPING WEIGHT WEIGHT CAPACITY OCCUPANT SAFE WORKING LOAD OVERALL LENGTH OVERALL WIDTH SPLIT SPRING TO ENDS HEAD FOOT ADJUSTMENT RANGE DECK BED END COMPONENTS 176.5 lbs (80.1 kg) 350 lbs (159 kg) 450 lbs (204 kg) 88 in (223.4 cm) 36 in (91.4 ... Label 1117179 Rev B located on the gearbox (not shown). Unplug product before storing. DO NOT power wash or steam clean. P/N 1116654 Underside of bed shown. Disinfect and wash all connection ports are not damaged and that all components. 4. Make sure all electrical parts (motors, junction box and pendant)...
... Full Electric 5410IVC, 5411IVC SHIPPING WEIGHT WEIGHT CAPACITY OCCUPANT SAFE WORKING LOAD OVERALL LENGTH OVERALL WIDTH SPLIT SPRING TO ENDS HEAD FOOT ADJUSTMENT RANGE DECK BED END COMPONENTS 176.5 lbs (80.1 kg) 350 lbs (159 kg) 450 lbs (204 kg) 88 in (223.4 cm) 36 in (91.4 ... Label 1117179 Rev B located on the gearbox (not shown). Unplug product before storing. DO NOT power wash or steam clean. P/N 1116654 Underside of bed shown. Disinfect and wash all connection ports are not damaged and that all components. 4. Make sure all electrical parts (motors, junction box and pendant)...
Owners Manual
Page 6
Invacare® Homecare Beds Semi-Electric Single Crank Hi/Lo 5310IVC, 5311IVC SHIPPING WEIGHT WEIGHT CAPACITY OCCUPANT SAFE WORKING LOAD OVERALL LENGTH OVERALL WIDTH SPLIT SPRINGS TO ENDS HEAD FOOT ADJUSTMENT RANGE DECK BED END COMPONENTS 172 lbs (78.0 kg) 350 lbs (159 kg) 450 lbs (204 kg) 88 in (223.4 cm)...cm) ± 2 in to 23 in (58.3 cm) ± 2 in 26 ¼ in (66.7 cm) to 33 ¾ in (85.7 cm) Head Spring, Universal Bed Ends, Foot Spring Two Motors Manual Single Crank-Hi/Lo 5307IVC SHIPPING WEIGHT WEIGHT CAPACITY OCCUPANT SAFE WORKING LOAD OVERALL LENGTH OVERALL WIDTH SPLIT SPRINGS...
Invacare® Homecare Beds Semi-Electric Single Crank Hi/Lo 5310IVC, 5311IVC SHIPPING WEIGHT WEIGHT CAPACITY OCCUPANT SAFE WORKING LOAD OVERALL LENGTH OVERALL WIDTH SPLIT SPRINGS TO ENDS HEAD FOOT ADJUSTMENT RANGE DECK BED END COMPONENTS 172 lbs (78.0 kg) 350 lbs (159 kg) 450 lbs (204 kg) 88 in (223.4 cm)...cm) ± 2 in to 23 in (58.3 cm) ± 2 in 26 ¼ in (66.7 cm) to 33 ¾ in (85.7 cm) Head Spring, Universal Bed Ends, Foot Spring Two Motors Manual Single Crank-Hi/Lo 5307IVC SHIPPING WEIGHT WEIGHT CAPACITY OCCUPANT SAFE WORKING LOAD OVERALL LENGTH OVERALL WIDTH SPLIT SPRINGS...
Owners Manual
Page 7
Accessories are subject to change . Contact Dealer or Invacare for current list DESCRIPTION MODEL NUMBER WEIGHT BED RAIL, FULL 6629 28 lbs (12.7 kg) 6629P 28 lbs (12.7 kg) BED RAIL, HALF LENGTH 6630DS 24 lbs (10.9 kg) ASSIST RAIL 6632 24 lbs (10.9 kg) TRAPEZE 7740A 30 lbs (...5185 30 lbs (13.6 kg) 5185XL 30 lbs (13.6 kg) 1114836-H-05 Overview Accessories are subject to 1060 hpa 7 Contact Dealer or Invacare for current list DESCRIPTION MODEL NUMBER WEIGHT MATTRESS Solace Series, Softform Series 23-31 lbs (10.4-14.1 kg) varies depending on model microAir Series...
Accessories are subject to change . Contact Dealer or Invacare for current list DESCRIPTION MODEL NUMBER WEIGHT BED RAIL, FULL 6629 28 lbs (12.7 kg) 6629P 28 lbs (12.7 kg) BED RAIL, HALF LENGTH 6630DS 24 lbs (10.9 kg) ASSIST RAIL 6632 24 lbs (10.9 kg) TRAPEZE 7740A 30 lbs (...5185 30 lbs (13.6 kg) 5185XL 30 lbs (13.6 kg) 1114836-H-05 Overview Accessories are subject to 1060 hpa 7 Contact Dealer or Invacare for current list DESCRIPTION MODEL NUMBER WEIGHT MATTRESS Solace Series, Softform Series 23-31 lbs (10.4-14.1 kg) varies depending on model microAir Series...
Owners Manual
Page 8
...completely reading and understanding these instructions and any additional instructional material such as user manuals, service manuals or instruction sheets supplied with Invacare bed products. 8 1114836-H-05 "Qualified Technician Only" sections are damaged or if product is not working properly. THE INFORMATION CONTAINED IN... allow others to the user and/or caregiver. - Do not use . Risk Of Death, Injury, Or Damage Improper use of NON-Invacare bed accessories may cause injury or damage. - Continued use of Death, Injury or Damage To avoid injury or product damage: - Check ALL ...
...completely reading and understanding these instructions and any additional instructional material such as user manuals, service manuals or instruction sheets supplied with Invacare bed products. 8 1114836-H-05 "Qualified Technician Only" sections are damaged or if product is not working properly. THE INFORMATION CONTAINED IN... allow others to the user and/or caregiver. - Do not use . Risk Of Death, Injury, Or Damage Improper use of NON-Invacare bed accessories may cause injury or damage. - Continued use of Death, Injury or Damage To avoid injury or product damage: - Check ALL ...
Owners Manual
Page 10
... any extremities protrude over the side or between the raised bed frame components at www.invacare.com for additional safety information. 10 1114836-H-05 Using the bed on these functions. - DO NOT move under the bed: - Be aware of the bed, ALWAYS lock the casters. The bed is not stable. DANGER! When transferring into or out...
... any extremities protrude over the side or between the raised bed frame components at www.invacare.com for additional safety information. 10 1114836-H-05 Using the bed on these functions. - DO NOT move under the bed: - Be aware of the bed, ALWAYS lock the casters. The bed is not stable. DANGER! When transferring into or out...
Owners Manual
Page 11
..., Injury, Or Damage To avoid fire hazards and tubing entanglement: - To avoid patient entrapment: - The Invacare mattress MUST fit firmly against the bed frame AND bed side rails to bed height. - Read and understand the User Manual prior to using nasal or masked type oxygen administering equipment, the... routed and secured properly to ensure that the tubing does not become entangled and/or severed during normal operation of manual/electric bed. - When using the Invacare bed and bed rails. Risk Of Death, Injury, Or Damage To avoid fire hazards, injury or damage: - DO NOT use , make...
..., Injury, Or Damage To avoid fire hazards and tubing entanglement: - To avoid patient entrapment: - The Invacare mattress MUST fit firmly against the bed frame AND bed side rails to bed height. - Read and understand the User Manual prior to using nasal or masked type oxygen administering equipment, the... routed and secured properly to ensure that the tubing does not become entangled and/or severed during normal operation of manual/electric bed. - When using the Invacare bed and bed rails. Risk Of Death, Injury, Or Damage To avoid fire hazards, injury or damage: - DO NOT use , make...
Owners Manual
Page 12
...to mattress compression. - Risk of Death or Injury An increased risk of Non-Invacare mattresses. Read and understand the instructions or label provided with Invacare beds at all times. 12 DANGER! Invacare recommends that the mattress be replaced. 1114836-H-05 DANGER! If you do not ...securely in place before using. Otherwise, individuals may become trapped between the bed, mattress, and/or bed rail. To avoid injury, ensure that the side rails are used with mattress. - Invacare® Homecare Beds WARNING! Risk Of Injury Or Damage To avoid injury or damage from misuse...
...to mattress compression. - Risk of Death or Injury An increased risk of Non-Invacare mattresses. Read and understand the instructions or label provided with Invacare beds at all times. 12 DANGER! Invacare recommends that the mattress be replaced. 1114836-H-05 DANGER! If you do not ...securely in place before using. Otherwise, individuals may become trapped between the bed, mattress, and/or bed rail. To avoid injury, ensure that the side rails are used with mattress. - Invacare® Homecare Beds WARNING! Risk Of Injury Or Damage To avoid injury or damage from misuse...
Owners Manual
Page 13
... to the user manuals for beds and rails for moving the electric bed. - Invacare manuals are not interchangeable. If there is exerted on the bed rails. Replacement mattresses and bed side rails with a manual/electric bed, the bed rails DO NOT fall under each bed rail product entry to Bed Safety", published by the bed frame manufacturer are available at...
... to the user manuals for beds and rails for moving the electric bed. - Invacare manuals are not interchangeable. If there is exerted on the bed rails. Replacement mattresses and bed side rails with a manual/electric bed, the bed rails DO NOT fall under each bed rail product entry to Bed Safety", published by the bed frame manufacturer are available at...
Owners Manual
Page 14
... NOT change the plug in any manner. Risk of portable communications equipment in any way. Caution should be influenced by Radio Frequency Interference (RFI). - Invacare® Homecare Beds Electrical WARNING! To avoid injury or product damage, when using damaged parts: - If it still does not fit, contact a qualified electrician to use of...
... NOT change the plug in any manner. Risk of portable communications equipment in any way. Caution should be influenced by Radio Frequency Interference (RFI). - Invacare® Homecare Beds Electrical WARNING! To avoid injury or product damage, when using damaged parts: - If it still does not fit, contact a qualified electrician to use of...
Owners Manual
Page 15
...accessories, mattress, occupant and any time. - This product should not be used adjacent to or stacked with other than one person on the bed at any other objects positioned on raised head or foot sections of accessories, transducers, cords and cables other equipment and that your entire body... weight is necessary, this bed - Body weight should be observed to verify normal operation in the configuration in such a way that if adjacent or stacked use of the...
...accessories, mattress, occupant and any time. - This product should not be used adjacent to or stacked with other than one person on the bed at any other objects positioned on raised head or foot sections of accessories, transducers, cords and cables other equipment and that your entire body... weight is necessary, this bed - Body weight should be observed to verify normal operation in the configuration in such a way that if adjacent or stacked use of the...
Owners Manual
Page 16
... attached to use of Non-Invacare bed rails. To avoid injury, ensure that the Invacare bed rails are used with Invacare beds at all times. 16 1114836-H-05 Fall hazard exists due to the bed while entering or exiting. Non-Invacare mattresses are potentially incompatible with Invacare beds. - Non-Invacare bed rails are potentially incompatible with Invacare beds. - Invacare® Homecare Beds 3.2 Operating Information DANGER! DANGER...
... attached to use of Non-Invacare bed rails. To avoid injury, ensure that the Invacare bed rails are used with Invacare beds at all times. 16 1114836-H-05 Fall hazard exists due to the bed while entering or exiting. Non-Invacare mattresses are potentially incompatible with Invacare beds. - Non-Invacare bed rails are potentially incompatible with Invacare beds. - Invacare® Homecare Beds 3.2 Operating Information DANGER! DANGER...
Owners Manual
Page 17
... Servicing Double-Insulated Products Protection to a power outage or an electronic malfunction, an emergency crank is on and could be harmful to the bed. - Replacement parts for disposal. WARNING! The product does not generate waste or residue in accordance with the individual product marking for a... manufacturer that are routed and secured properly. - Risk of life. 17 A double-insulated product is to be identical to raise the bed. Ensure all drive shafts, free of the system, and is marked with the Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19...
... Servicing Double-Insulated Products Protection to a power outage or an electronic malfunction, an emergency crank is on and could be harmful to the bed. - Replacement parts for disposal. WARNING! The product does not generate waste or residue in accordance with the individual product marking for a... manufacturer that are routed and secured properly. - Risk of life. 17 A double-insulated product is to be identical to raise the bed. Ensure all drive shafts, free of the system, and is marked with the Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19...
Owners Manual
Page 18
... In case of cartons shipped with damaged parts could lead to the bed malfunctioning, causing injury to the Homecare Beds are marked accordingly. - Set-up 4.1 Receiving WARNING! If shortage occurs, IMMEDIATELY contact Invacare Customer Service department at the facility to check off items as they are... or Damage To avoid damage or personal injury: - DO NOT attempt to operate bed controls prior to have the truck driver sign the copy acknowledging the count. 4. Invacare® Homecare Beds 4 Set-up and Assembly instructions MUST be performed by qualified technicians only. 1.
... In case of cartons shipped with damaged parts could lead to the bed malfunctioning, causing injury to the Homecare Beds are marked accordingly. - Set-up 4.1 Receiving WARNING! If shortage occurs, IMMEDIATELY contact Invacare Customer Service department at the facility to check off items as they are... or Damage To avoid damage or personal injury: - DO NOT attempt to operate bed controls prior to have the truck driver sign the copy acknowledging the count. 4. Invacare® Homecare Beds 4 Set-up and Assembly instructions MUST be performed by qualified technicians only. 1.
Owners Manual
Page 19
... Assembly in two pieces D • One Hand Crank E 1114836-H-05 D B 1. Foot Spring Section carton includes: • One Foot Spring C (electric beds include pendent, junction box with power cord, and head, foot and hi/lo [full electric only] motors with cables) . • One emergency crank handle... (electric beds ONLY). 3. Remove any loose packing from the carton B. 2. Remove any loose packing A from the carton A. 2. Head Spring Section carton includes: ...
... Assembly in two pieces D • One Hand Crank E 1114836-H-05 D B 1. Foot Spring Section carton includes: • One Foot Spring C (electric beds include pendent, junction box with power cord, and head, foot and hi/lo [full electric only] motors with cables) . • One emergency crank handle... (electric beds ONLY). 3. Remove any loose packing from the carton B. 2. Remove any loose packing A from the carton A. 2. Head Spring Section carton includes: ...
Owners Manual
Page 20
... the following and contact a qualified technician or Invacare if any of the following : • Two Universal Low Bed Ends. • Four Casters (two locking and two non-locking casters). • One Drive Shaft Assembly in position B (outer bed legs), the height range is 12 to 23...taken from floor C to 20 inches. • With casters installed in two pieces. Ensure that the connectors are damaged. - Invacare® Homecare Beds Optional Low Bed End Kit This kit includes the following issues are present: - Pendant covering is missing or damaged. Motor cables have cuts or damage...
... the following and contact a qualified technician or Invacare if any of the following : • Two Universal Low Bed Ends. • Four Casters (two locking and two non-locking casters). • One Drive Shaft Assembly in position B (outer bed legs), the height range is 12 to 23...taken from floor C to 20 inches. • With casters installed in two pieces. Ensure that the connectors are damaged. - Invacare® Homecare Beds Optional Low Bed End Kit This kit includes the following issues are present: - Pendant covering is missing or damaged. Motor cables have cuts or damage...
Owners Manual
Page 21
Remove the foot spring section B of the bed from each other. 7. For set-up 6. Hook the top head spring center mounting latch A to secure the mounting latches and rivets. 9. Place the foot spring ... are on your right. 1114836-H-05 8. Remove the head spring section (5000 IVC) A of the bed from the packing carton. 2. 4.4 Assembling the Head and Foot Spring Sections Set-up purposes, the motors on the semi-electric (5890IVC and 5891IVC) and full electric (5490IVC and 5491IVC) foot springs as well as the crank...
Remove the foot spring section B of the bed from each other. 7. For set-up 6. Hook the top head spring center mounting latch A to secure the mounting latches and rivets. 9. Place the foot spring ... are on your right. 1114836-H-05 8. Remove the head spring section (5000 IVC) A of the bed from the packing carton. 2. 4.4 Assembling the Head and Foot Spring Sections Set-up purposes, the motors on the semi-electric (5890IVC and 5891IVC) and full electric (5490IVC and 5491IVC) foot springs as well as the crank...
Owners Manual
Page 22
Invacare® Homecare Beds 4.5 Assembling the Spring Fabric 4.6 Adjusting and Reconnecting the Head Section Pull Tube 1. Connect the spring fabric A together with hitch pin E. 22 1114836-H-05 Connect the ... pull tube shaft C manually until the spring button "clicks" into the lift arm slot H. b. Replace the grommet/washer F. Lift the head spring C away from the bed frame to give slack to the lift arm of the foot spring, remove the hitch pin E and grommet/washer F from the side frame of the...
Invacare® Homecare Beds 4.5 Assembling the Spring Fabric 4.6 Adjusting and Reconnecting the Head Section Pull Tube 1. Connect the spring fabric A together with hitch pin E. 22 1114836-H-05 Connect the ... pull tube shaft C manually until the spring button "clicks" into the lift arm slot H. b. Replace the grommet/washer F. Lift the head spring C away from the bed frame to give slack to the lift arm of the foot spring, remove the hitch pin E and grommet/washer F from the side frame of the...