User Guide
Page 14
...and Installing the System Cover 26 Removing the System Cover 26 Installing the System Cover 27 Removing and Installing the Processor Air Duct 28 Removing the Processor Air Duct 28 Installing the Processor Air Duct 30 Installing and Removing Memory 31 Installing ...Intel® RMM NIC .. 56 Installing the Intel® RMM and Intel® RMM NIC 56 Removing the Intel® RMM and Intel® RMM NIC 57 Replacing the Backplane Board 58 Removing the Backplane Board 58 Installing the Backplane Board 59 Installing and Removing the Server Board 62 xiv Intel® Server System SR1500AL...
...and Installing the System Cover 26 Removing the System Cover 26 Installing the System Cover 27 Removing and Installing the Processor Air Duct 28 Removing the Processor Air Duct 28 Installing the Processor Air Duct 30 Installing and Removing Memory 31 Installing ...Intel® RMM NIC .. 56 Installing the Intel® RMM and Intel® RMM NIC 56 Removing the Intel® RMM and Intel® RMM NIC 57 Replacing the Backplane Board 58 Removing the Backplane Board 58 Installing the Backplane Board 59 Installing and Removing the Server Board 62 xiv Intel® Server System SR1500AL...
User Guide
Page 19
... Components 13 Figure 10. Installing the Memory 32 Figure 24. Removing PCI Riser Assembly from the Server System 45 Figure 37. Active Backplane Components 12 Figure 9. Installing the Server System Cover 28 Figure 20. Installing the PCI-X* Riser Card into Carrier 41 Figure 33. List of Figures Figure 1. Intel® Integrated Server System SR1500AL 3 Figure 2. ChassisComponents 6 Figure 3. BIOS Select...
... Components 13 Figure 10. Installing the Memory 32 Figure 24. Removing PCI Riser Assembly from the Server System 45 Figure 37. Active Backplane Components 12 Figure 9. Installing the Server System Cover 28 Figure 20. Installing the PCI-X* Riser Card into Carrier 41 Figure 33. List of Figures Figure 1. Intel® Integrated Server System SR1500AL 3 Figure 2. ChassisComponents 6 Figure 3. BIOS Select...
User Guide
Page 26
...(430 mm) wide • 27.25 inches (692 mm) deep • 31 pounds (14.1 kg) - Table 2. Intel® Server System SR1500AL Feature Summary Feature Dimensions Server Board Processor Memory Chipset Peripheral Interfaces I /O Controller Hub External connections: • Stacked PS/2* ports for keyboard and mouse • RJ45 Serial... 16 MB DDR SDRAM Intel® 82563EB dual port controller for up to 32 GB DDR2 533/667 MHz FBDIMM memory Intel® 5000P chipset, consisting of the server system. max chassis weight Intel® Server Board S5000PAL Support for up to two Dual-Core Intel®...
...(430 mm) wide • 27.25 inches (692 mm) deep • 31 pounds (14.1 kg) - Table 2. Intel® Server System SR1500AL Feature Summary Feature Dimensions Server Board Processor Memory Chipset Peripheral Interfaces I /O Controller Hub External connections: • Stacked PS/2* ports for keyboard and mouse • RJ45 Serial... 16 MB DDR SDRAM Intel® 82563EB dual port controller for up to 32 GB DDR2 533/667 MHz FBDIMM memory Intel® 5000P chipset, consisting of the server system. max chassis weight Intel® Server Board S5000PAL Support for up to two Dual-Core Intel®...
User Guide
Page 52
... and the AC power cable(s) into the server. 30 Intel® Server System SR1500AL User's Guide Do not remove memory air deflector. Use caution not to reveal underside (see letter "B") by sliding slotted holes off duct pins. Install the server system cover. See the figure below. The front...precautions at the beginning of the air duct should contact the fan module. See ""Safety Information". 2. Remove the server system cover. For instructions, see "Installing the System Cover". 8. only if two processors are installed: remove air dam (see letter "A"). 5. Place the processor air...
... and the AC power cable(s) into the server. 30 Intel® Server System SR1500AL User's Guide Do not remove memory air deflector. Use caution not to reveal underside (see letter "B") by sliding slotted holes off duct pins. Install the server system cover. See the figure below. The front...precautions at the beginning of the air duct should contact the fan module. See ""Safety Information". 2. Remove the server system cover. For instructions, see "Installing the System Cover". 8. only if two processors are installed: remove air dam (see letter "A"). 5. Place the processor air...
User Guide
Page 53
...the Processor Air Duct Installing and Removing Memory The silkscreen on the board for the DIMMs displays DIMM A1, DIMM A2, DIMM B1, DIMM B2, DIMM C1, DIMM C2, DIMM D1 and DIMM D2 starting from the server. 4. Intel® Server System SR1500AL User's Guide 31 TP02202 Figure 22.... Locate the DIMM sockets (see "Removing the System Cover". 5. Turn off the server. 3. Turn off all peripheral devices connected to the list of tested DIMMs....
...the Processor Air Duct Installing and Removing Memory The silkscreen on the board for the DIMMs displays DIMM A1, DIMM A2, DIMM B1, DIMM B2, DIMM C1, DIMM C2, DIMM D1 and DIMM D2 starting from the server. 4. Intel® Server System SR1500AL User's Guide 31 TP02202 Figure 22.... Locate the DIMM sockets (see "Removing the System Cover". 5. Turn off the server. 3. Turn off all peripheral devices connected to the list of tested DIMMs....
User Guide
Page 54
... (see letter "D" in the figure above the socket. Installing the Memory TP02072 6. Align the notch on the top edge of the DIMM into place (see letter "A" in the figure above). 7. Make sure the clips at either end of the DIMM with the key in the figure above ). 32 Intel® Server System SR1500AL User's Guide
... (see letter "D" in the figure above the socket. Installing the Memory TP02072 6. Align the notch on the top edge of the DIMM into place (see letter "A" in the figure above). 7. Make sure the clips at either end of the DIMM with the key in the figure above ). 32 Intel® Server System SR1500AL User's Guide
User Guide
Page 95
...contains a number of features. If a value cannot be changed for those features that contains user-selectable parameters. See "Server System References" for a link to the Intel® 5000 Series Chipsets Server Board Family Datasheet where you will see other prompts but not the prompt: Warning: CMOS checksum invalid Warning: CMOS ...In a third condition, when CMOS/NVRAM has been corrupted, you will load default values for CMOS and attempt to clear the CMOS memory. You can run BIOS Setup with a value field that are not able to access BIOS Setup, you have moved the CMOS jumper on ...
...contains a number of features. If a value cannot be changed for those features that contains user-selectable parameters. See "Server System References" for a link to the Intel® 5000 Series Chipsets Server Board Family Datasheet where you will see other prompts but not the prompt: Warning: CMOS checksum invalid Warning: CMOS ...In a third condition, when CMOS/NVRAM has been corrupted, you will load default values for CMOS and attempt to clear the CMOS memory. You can run BIOS Setup with a value field that are not able to access BIOS Setup, you have moved the CMOS jumper on ...
User Guide
Page 97
...] If "Yes" is selected and the key is pressed, all changes are saved and Setup is returned to upgrade the BIOS in flash memory. Note: In the unlikely event that a BIOS error occurs during the BIOS update process, a recovery process may need these settings to configure your...when you see the message: Press Key if you to where they were before was pressed without affecting any existing values. Intel® Server System SR1500AL User's Guide 75 See "Server System References" for the Upgrade The steps below explain how to prepare to upgrade the BIOS, including how to record the current...
...] If "Yes" is selected and the key is pressed, all changes are saved and Setup is returned to upgrade the BIOS in flash memory. Note: In the unlikely event that a BIOS error occurs during the BIOS update process, a recovery process may need these settings to configure your...when you see the message: Press Key if you to where they were before was pressed without affecting any existing values. Intel® Server System SR1500AL User's Guide 75 See "Server System References" for the Upgrade The steps below explain how to prepare to upgrade the BIOS, including how to record the current...
User Guide
Page 107
... include updates for one of the methods below. Intel provides a package called the "Platform Confidence Test" that might occur while you are using the latest firmware and files. This clears system memory, restarts POST, reloads the operating system, and halts power to all peripherals Reset the BMC... and get it back to the server firmware and files, also update any issue, first ensure you are using...
... include updates for one of the methods below. Intel provides a package called the "Platform Confidence Test" that might occur while you are using the latest firmware and files. This clears system memory, restarts POST, reloads the operating system, and halts power to all peripherals Reset the BMC... and get it back to the server firmware and files, also update any issue, first ensure you are using...
User Guide
Page 108
.../off switch on the front panel to turn the server on (power on light should be lit)? • Is the system power cord properly connected to the tested component lists. 86 Intel® Server System SR1500AL User's Guide See the operating system documentation. • Did you are experiencing is with... Steps Checklist • Is AC power available at initial system startup are usually caused by an incorrect installation or configuration. Check the tested memory, and chassis lists, as well as the supported hardware and operating system list. If applicable, ensure that occur at the wall ...
.../off switch on the front panel to turn the server on (power on light should be lit)? • Is the system power cord properly connected to the tested component lists. 86 Intel® Server System SR1500AL User's Guide See the operating system documentation. • Did you are experiencing is with... Steps Checklist • Is AC power available at initial system startup are usually caused by an incorrect installation or configuration. Check the tested memory, and chassis lists, as well as the supported hardware and operating system list. If applicable, ensure that occur at the wall ...
User Guide
Page 110
...Does Not Light Check the following: • Did you press the power-on the bottom of the power supply, next to the system requirements. • Remove the memory DIMMs and re-seat them . • Make sure the chassis standoffs are installed only below in one , is not detected.... • Make sure the processor(s) comply with application software. • The bootable CD-ROM is it turned on the back of the server board and cause a short. 88 Intel® Server System SR1500AL User's Guide Specific Problems and Corrective Actions This section provides possible solutions for help.
...Does Not Light Check the following: • Did you press the power-on the bottom of the power supply, next to the system requirements. • Remove the memory DIMMs and re-seat them . • Make sure the chassis standoffs are installed only below in one , is not detected.... • Make sure the processor(s) comply with application software. • The bootable CD-ROM is it turned on the back of the server board and cause a short. 88 Intel® Server System SR1500AL User's Guide Specific Problems and Corrective Actions This section provides possible solutions for help.
User Guide
Page 111
...a reboot between each addition. • Make sure the memory DIMMs comply with the system requirements. • Make sure the memory DIMMs have been populated according to the system requirements. • Remove the memory DIMMs and re-seat them . Reboot the system for help. Verify that the video controller board is useful... properly installed? If you hear. If successful, add the cards back in cards and see if the video returns. Intel® Server System SR1500AL User's Guide 89 Verify that the video works using an add-in and turned on the screen after you reboot the...
...a reboot between each addition. • Make sure the memory DIMMs comply with the system requirements. • Make sure the memory DIMMs have been populated according to the system requirements. • Remove the memory DIMMs and re-seat them . Reboot the system for help. Verify that the video controller board is useful... properly installed? If you hear. If successful, add the cards back in cards and see if the video returns. Intel® Server System SR1500AL User's Guide 89 Verify that the video works using an add-in and turned on the screen after you reboot the...
User Guide
Page 116
A table of these beep codes to Take Memory error. Please note that can aid in sleep stats S0 Press ID LED button or use is bing used, the server board may be faulty. 94 Intel® Server System SR1500AL User's Guide Reseat the memory or replace the DIMMs with a description of error ...conditions. If the error still occurs, contact your system. If the beep codes are not generated after the ...
A table of these beep codes to Take Memory error. Please note that can aid in sleep stats S0 Press ID LED button or use is bing used, the server board may be faulty. 94 Intel® Server System SR1500AL User's Guide Reseat the memory or replace the DIMMs with a description of error ...conditions. If the error still occurs, contact your system. If the beep codes are not generated after the ...
User Guide
Page 124
USB Port USB Port Diagnostic LEDs Back edge of memory OFF Programming timing parameters in the memory controller G Configuring memory parameters in the memory controller OFF Optimizing memory controller settings G Initializing memory, such as ECC init OFF Testing memory 102 Intel® Server System SR1500AL User's Guide Diagnostic LED POST Code Decoder Checkpoint Diagnostic LED Decoder Description G=Green, R=Red, A=Amber MSB LSB...
USB Port USB Port Diagnostic LEDs Back edge of memory OFF Programming timing parameters in the memory controller G Configuring memory parameters in the memory controller OFF Optimizing memory controller settings G Initializing memory, such as ECC init OFF Testing memory 102 Intel® Server System SR1500AL User's Guide Diagnostic LED POST Code Decoder Checkpoint Diagnostic LED Decoder Description G=Green, R=Red, A=Amber MSB LSB...
User Guide
Page 127
... Exiting Sleep state A R R R Operating system has requested EFI to close boot services (ExitBootServices ( ) has been called) A R R A Operating system has switched to virtual address mode (SetVirtualAddressMap ( ) has been called) Intel® Server System SR1500AL User's Guide 105 Table 12. Diagnostic LED POST... (PEI) Core 0xE0h 0xE2h 0xE1h 0xE3h R R R OFF Started dispatching early initialization modules (PEIM) R R A OFF Initial memory found, configured, and installed correctly R R R G Reserved for initialization module use (PEIM) R R A G Reserved for ...
... Exiting Sleep state A R R R Operating system has requested EFI to close boot services (ExitBootServices ( ) has been called) A R R A Operating system has switched to virtual address mode (SetVirtualAddressMap ( ) has been called) Intel® Server System SR1500AL User's Guide 105 Table 12. Diagnostic LED POST... (PEI) Core 0xE0h 0xE2h 0xE1h 0xE3h R R R OFF Started dispatching early initialization modules (PEIM) R R A OFF Initial memory found, configured, and installed correctly R R R G Reserved for initialization module use (PEIM) R R A G Reserved for ...