..., operating system. Use this chapter for step-bystep instructions and diagrams for installing or replacing components such as the memory, processor, PCI card, and the battery, among other components you may be used with the following accessory items ... of a problem. Chapter 3 provides instructions on the Intel Server Board SE7320SP2 / SE7525GP2. You will also find suggestions for performing troubleshooting activities to http://www.support.intel.com/support/motherboards/server/se7320SP2/ or http://www.support.intel.com/support/motherboards/server/se7525GP2/. In this chapter, you...
..., operating system. Use this chapter for step-bystep instructions and diagrams for installing or replacing components such as the memory, processor, PCI card, and the battery, among other components you may be used with the following accessory items ... of a problem. Chapter 3 provides instructions on the Intel Server Board SE7320SP2 / SE7525GP2. You will also find suggestions for performing troubleshooting activities to http://www.support.intel.com/support/motherboards/server/se7320SP2/ or http://www.support.intel.com/support/motherboards/server/se7525GP2/. In this chapter, you...
User Guide
Page 4
... list of the screen and select the option to manage your Intel® server For drivers http://support.intel.com/support/motherboards/server/SE7320SP2/ Spares and Configuration Guide Tested Hardware and Operating System List Reference Chassis List Supported Processors Supported Memory Power Budget Intel Server Management Driver (for operating system drivers) For firmware and BIOS...
... list of the screen and select the option to manage your Intel® server For drivers http://support.intel.com/support/motherboards/server/SE7320SP2/ Spares and Configuration Guide Tested Hardware and Operating System List Reference Chassis List Supported Processors Supported Memory Power Budget Intel Server Management Driver (for operating system drivers) For firmware and BIOS...
User Guide
Page 11
... the Server Board 21 Hardware Requirements ...22 2 Server Board Installations and Upgrades 23 Before You Begin ...23 Tools and Supplies Needed 23 Installing and Removing Memory 23 Installing DIMMs...23 Removing DIMMs...25 Installing or Replacing the Processor 25 Installing the Processor 26 Removing the Processor 28 Installing a PCI Card ...28... Drive Activity Light Does Not Light 42 CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light 42 Cannot Connect to a Server 42 Intel Server Board SE7320SP2 / SE7525GP2 User Guide 11
... the Server Board 21 Hardware Requirements ...22 2 Server Board Installations and Upgrades 23 Before You Begin ...23 Tools and Supplies Needed 23 Installing and Removing Memory 23 Installing DIMMs...23 Removing DIMMs...25 Installing or Replacing the Processor 25 Installing the Processor 26 Removing the Processor 28 Installing a PCI Card ...28... Drive Activity Light Does Not Light 42 CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light 42 Cannot Connect to a Server 42 Intel Server Board SE7320SP2 / SE7525GP2 User Guide 11
User Guide
Page 13
... Table 2. Table 9. Installing Memory 24 Figure 7. Installing Heat Sink over Processor 27 Figure 9. Table 10. Intel Server Board SE7320SP2 / SE7525GP2 Layout 18 Figure 3. Replacing the Battery 30 Tables Table 1. Table 3. Table 5. Table 7. Server Board SE7320SP2 Features 16 Server Board SE7525GP2 ... Error Messages 47 Beep Codes 48 BIOS Recovery Beep Codes 49 Product Certification Markings 52 Intel Server Board SE7320SP2 / SE7525GP2 User Guide 13 Intel® Server Board SE7320SP2 15 Figure 2. Table 4. Table 6. Back Panel Connectors 20 Figure 5. Table 8. ...
... Table 2. Table 9. Installing Memory 24 Figure 7. Installing Heat Sink over Processor 27 Figure 9. Table 10. Intel Server Board SE7320SP2 / SE7525GP2 Layout 18 Figure 3. Replacing the Battery 30 Tables Table 1. Table 3. Table 5. Table 7. Server Board SE7320SP2 Features 16 Server Board SE7525GP2 ... Error Messages 47 Beep Codes 48 BIOS Recovery Beep Codes 49 Product Certification Markings 52 Intel Server Board SE7320SP2 / SE7525GP2 User Guide 13 Intel® Server Board SE7320SP2 15 Figure 2. Table 4. Table 6. Back Panel Connectors 20 Figure 5. Table 8. ...
User Guide
Page 16
... x4 PCI-Express; Server Board SE7320SP2 Features Feature Description Processors Memory Chipset Support for two Intel® Xeon™ processors in two 604-pin Intel Xeon processor sockets with an 800 MHz system bus Four 184-pin DDR SDRAM Dual Inline Memory Module (DIMM) sockets Support for up to 8 GB Registered ECC system memory Support for single...
... x4 PCI-Express; Server Board SE7320SP2 Features Feature Description Processors Memory Chipset Support for two Intel® Xeon™ processors in two 604-pin Intel Xeon processor sockets with an 800 MHz system bus Four 184-pin DDR SDRAM Dual Inline Memory Module (DIMM) sockets Support for up to 8 GB Registered ECC system memory Support for single...
User Guide
Page 17
...Intel/AMI BIOS with support for one x4 PCI-Express; Server Board SE7525GP2 Features Feature Description Processors Memory Chipset Support for two Intel® Xeon™ processors in two 604-pin Intel Xeon... processor sockets with an 800 MHz system bus Four 184-pin DDR SDRAM Dual Inline Memory Module (DIMM) sockets Support for up to 8 GB Registered ECC system memory... symmetrical flash memory Support... One Intel®...Management Leadership Technologies Intel Server Management ...
...Intel/AMI BIOS with support for one x4 PCI-Express; Server Board SE7525GP2 Features Feature Description Processors Memory Chipset Support for two Intel® Xeon™ processors in two 604-pin Intel Xeon... processor sockets with an 800 MHz system bus Four 184-pin DDR SDRAM Dual Inline Memory Module (DIMM) sockets Support for up to 8 GB Registered ECC system memory... symmetrical flash memory Support... One Intel®...Management Leadership Technologies Intel Server Management ...
User Guide
Page 22
...Xeon processor are : 128Mb, 256Mb, 512Mb, 1Gb and 2Gb. Memory DIMM technologies supported are not supported for either DDR266 or DDR333 memory. For a complete list of supported DIMMs, see the links under "Additional Information and Software." However, for qualified DIMMs approved by Intel. The mixing of DDR266 and DDR333 memory is required. Intel Server Board SE7320SP2... / SE7525GP2 User Guide 22 Both server boards are paired with DIMMs on server boards SE7320SP2 and SE7525GP2....
...Xeon processor are : 128Mb, 256Mb, 512Mb, 1Gb and 2Gb. Memory DIMM technologies supported are not supported for either DDR266 or DDR333 memory. For a complete list of supported DIMMs, see the links under "Additional Information and Software." However, for qualified DIMMs approved by Intel. The mixing of DDR266 and DDR333 memory is required. Intel Server Board SE7320SP2... / SE7525GP2 User Guide 22 Both server boards are paired with DIMMs on server boards SE7320SP2 and SE7525GP2....
User Guide
Page 23
Turn off all peripheral devices connected to the server. For DIMM population rules, see "Memory." See your server product, pay close attention to the processor socket. Locate the DIMM sockets. See Figure 6. DIMM2A is the socket closest to... ESD precautions at the beginning of the board. Installing DIMMs To install DIMMs, follow these steps: 1. Turn off the server. 3. Remove the server's cover. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 23 Tools and Supplies Needed Phillips* (cross head) screwdriver (#1 bit and #2 bit) Needle nosed pliers ...
Turn off all peripheral devices connected to the server. For DIMM population rules, see "Memory." See your server product, pay close attention to the processor socket. Locate the DIMM sockets. See Figure 6. DIMM2A is the socket closest to... ESD precautions at the beginning of the board. Installing DIMMs To install DIMMs, follow these steps: 1. Turn off the server. 3. Remove the server's cover. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 23 Tools and Supplies Needed Phillips* (cross head) screwdriver (#1 bit and #2 bit) Needle nosed pliers ...
User Guide
Page 24
...Attach the AC power cord. Position the DIMM above the socket. Reconnect or replace any external components you needed to disconnect. 13. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 24 Make sure the clips at either end of the DIMM into place. Replace the server's cover. Make...remove. 12. Insert the bottom edge of the DIMM socket(s) are firmly in place. 11. Align the small notch in Figure 6). 9. Installing Memory TP00684 6. Reconnect any internal components you needed to the open position. 7. Holding the DIMM by the edges, remove it from its anti-static ...
...Attach the AC power cord. Position the DIMM above the socket. Reconnect or replace any external components you needed to disconnect. 13. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 24 Make sure the clips at either end of the DIMM into place. Replace the server's cover. Make...remove. 12. Insert the bottom edge of the DIMM socket(s) are firmly in place. 11. Align the small notch in Figure 6). 9. Installing Memory TP00684 6. Reconnect any internal components you needed to the open position. 7. Holding the DIMM by the edges, remove it from its anti-static ...
User Guide
Page 32
You will need these settings to run SETUP 2. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 32 Review also any release notes in flash memory. Boot the computer and press when you to upgrade the BIOS in the release notes file that a BIOS error occurs during the BIOS update process, ...
You will need these settings to run SETUP 2. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 32 Review also any release notes in flash memory. Boot the computer and press when you to upgrade the BIOS in the release notes file that a BIOS error occurs during the BIOS update process, ...
User Guide
Page 33
...values. If you selected option 2, to manually update the BIOS or to update the flash memory, you can either select "Update Flash Memory From a File" or "Update System BIOS": Update Flash Memory From a File: When prompted for a diskette that is the new version as follows: ...the BIOS update process! If you downloaded. Press . The system will then reboot. 4. Remove the diskette from the diskette drive. 6. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 33 The system will then reboot. 5. Boot the system with two options. While in the directory into the ...
...values. If you selected option 2, to manually update the BIOS or to update the flash memory, you can either select "Update Flash Memory From a File" or "Update System BIOS": Update Flash Memory From a File: When prompted for a diskette that is the new version as follows: ...the BIOS update process! If you downloaded. Press . The system will then reboot. 4. Remove the diskette from the diskette drive. 6. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 33 The system will then reboot. 5. Boot the system with two options. While in the directory into the ...
User Guide
Page 34
...using the F9 key, the system may function erratically. ✏ NOTE You may encounter a CMOS Checksum error or other problem after reboot. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 34 If this process. Press F10 and to select the correct .lng file. Changing the BIOS Language You can ...remove the diskette. The computer will reboot and the changes will take effect. Re-enter the values you want to flash the new language into memory, select Continue with the bootable diskette in drive A. If you enter Setup, check your settings, save your settings, and exit Setup. Boot...
...using the F9 key, the system may function erratically. ✏ NOTE You may encounter a CMOS Checksum error or other problem after reboot. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 34 If this process. Press F10 and to select the correct .lng file. Changing the BIOS Language You can ...remove the diskette. The computer will reboot and the changes will take effect. Re-enter the values you want to flash the new language into memory, select Continue with the bootable diskette in drive A. If you enter Setup, check your settings, save your settings, and exit Setup. Boot...
User Guide
Page 37
... configuration. See "Additional Information and Software" for assistance. Press: Reset button Power off and then on your diagnostics. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 37 If you are unable to the manufacturer's documentation that may help with them. If the ...to this : Soft boot reset to perform reset your system, such as video drivers, network drivers, and SCSI drivers. Clear system memory, restart POST, and reload the operating system. Hardware failure is with Newly Installed Application Software." To do this software. First Steps ...
... configuration. See "Additional Information and Software" for assistance. Press: Reset button Power off and then on your diagnostics. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 37 If you are unable to the manufacturer's documentation that may help with them. If the ...to this : Soft boot reset to perform reset your system, such as video drivers, network drivers, and SCSI drivers. Clear system memory, restart POST, and reload the operating system. Hardware failure is with Newly Installed Application Software." To do this software. First Steps ...
User Guide
Page 38
...). 4. CAUTION Turn off the system and any external peripheral devices. If the operating system normally loads from a CD-ROM disk. 6. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 38 Check the tested memory, and chassis lists, as well as the supported hardware and operating system list. Refer to the operating system documentation. Did...
...). 4. CAUTION Turn off the system and any external peripheral devices. If the operating system normally loads from a CD-ROM disk. 6. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 38 Check the tested memory, and chassis lists, as well as the supported hardware and operating system list. Refer to the operating system documentation. Did...
User Guide
Page 40
...137; Make sure the chassis standoffs are using a switch box, is it turned on ? If you are installed only below mounting holes. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 40 If successful, add the cards back in one at a time with a reboot between each addition. Make...a time with a reboot between each addition. Make sure the memory DIMMs comply with the system requirements. Make sure the memory DIMMs have been populated according to the system requirements. Remove the memory DIMMs and re-seat them. Make sure the processor(s) comply with...
...137; Make sure the chassis standoffs are using a switch box, is it turned on ? If you are installed only below mounting holes. Intel Server Board SE7320SP2 / SE7525GP2 User Guide 40 If successful, add the cards back in one at a time with a reboot between each addition. Make...a time with a reboot between each addition. Make sure the memory DIMMs comply with the system requirements. Make sure the memory DIMMs have been populated according to the system requirements. Remove the memory DIMMs and re-seat them. Make sure the processor(s) comply with...
User Guide
Page 46
... Management software to turn off or S5) On = Power on Off = Power is listed below. No action required. S3) Intel Server Board SE7320SP2 / SE7525GP2 User Guide 46 A table of these LEDs with a description of board Front center board Front center board 1" behind processor socket Front left ...warning Location Control panel and board rear left corner Control panel and board rear left corner Color Blue Green or Amber ATA activity Control panel Memory fault 1-6 POST code 1-4 (LSB, bit1, bit2, MSB) Fan Pack Fault CPU 1 & 2 Fan Fault CPU 1 & 2 Fault 5v Standby Power...
... Management software to turn off or S5) On = Power on Off = Power is listed below. No action required. S3) Intel Server Board SE7320SP2 / SE7525GP2 User Guide 46 A table of these LEDs with a description of board Front center board Front center board 1" behind processor socket Front left ...warning Location Control panel and board rear left corner Control panel and board rear left corner Color Blue Green or Amber ATA activity Control panel Memory fault 1-6 POST code 1-4 (LSB, bit1, bit2, MSB) Fan Pack Fault CPU 1 & 2 Fan Fault CPU 1 & 2 Fault 5v Standby Power...
User Guide
Page 47
... The battery may have either been corrupted or the battery has failed. The display type is correct. CMOS memory may be updated. Run Setup to be losing power. DMA Error Error during the memory test. Keyboard Error Error in CMOS. A: Drive Error No response from corresponding drive. CMOS Checksum Bad The CMOS... trying to access diskette drive controller. NVRAM was unable to set correct values. Make sure keyboard is selected correctly. ATAPI Incompatible Sec Master Drive - continued Intel Server Board SE7320SP2 / SE7525GP2 User Guide 47
... The battery may have either been corrupted or the battery has failed. The display type is correct. CMOS memory may be updated. Run Setup to be losing power. DMA Error Error during the memory test. Keyboard Error Error in CMOS. A: Drive Error No response from corresponding drive. CMOS Checksum Bad The CMOS... trying to access diskette drive controller. NVRAM was unable to set correct values. Make sure keyboard is selected correctly. ATAPI Incompatible Sec Master Drive - continued Intel Server Board SE7320SP2 / SE7525GP2 User Guide 47
User Guide
Page 48
.... A parity error occurred on an off-board card. A parity error occurred in onboard memory. User must enter Setup. not used ) 10 CMOS Shutdown register test error 11 Invalid BIOS (such as, POST module not found) Intel Server Board SE7320SP2 / SE7525GP2 User Guide 48 This error is followed by an address. This error is...
.... A parity error occurred on an off-board card. A parity error occurred in onboard memory. User must enter Setup. not used ) 10 CMOS Shutdown register test error 11 Invalid BIOS (such as, POST module not found) Intel Server Board SE7320SP2 / SE7525GP2 User Guide 48 This error is followed by an address. This error is...