Intel® Entry Server Chassis SC5275-E User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Order Number: C50277-001
Intel® Entry Server Chassis SC5275-E User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Order Number: C50277-001
User Guide
Page 2
... any intellectual property rights is granted by this document is the responsibility of others. Intel server boards contain a number of airflow required for cooling. Intel, Intel Pentium, and Intel Xeon are designed and tested to any time, without notice. Intel® Entry Server Chassis SC5275-E User Guide ii Except as the property of the system integrator that need adequate airflow for...
... any intellectual property rights is granted by this document is the responsibility of others. Intel server boards contain a number of airflow required for cooling. Intel, Intel Pentium, and Intel Xeon are designed and tested to any time, without notice. Intel® Entry Server Chassis SC5275-E User Guide ii Except as the property of the system integrator that need adequate airflow for...
User Guide
Page 3
... other components you will find information on the Intel® Entry Server Chassis SC5275-E. Intel® Entry Server Chassis SC5275-E User Guide iii This document provides a brief overview of the features of the board/chassis, a list of the Entry Server Chassis SC5275-E. This manual is compatible with the following Intel® Server Boards: Intel® Server Board SE7525GP2 Intel® Server Board SE7320SP2 Intel® Server Board SE7520BD2 For information about which items have...
... other components you will find information on the Intel® Entry Server Chassis SC5275-E. Intel® Entry Server Chassis SC5275-E User Guide iii This document provides a brief overview of the features of the board/chassis, a list of the Entry Server Chassis SC5275-E. This manual is compatible with the following Intel® Server Boards: Intel® Server Board SE7525GP2 Intel® Server Board SE7320SP2 Intel® Server Board SE7520BD2 For information about which items have...
User Guide
Page 4
... to spares, parts, and config guide) http://www.support.intel/com/support/mothterboards/server/S C5275E/tested_hwos.htm http://support.intel.com/support/motherboards/server/SC5275 E/os.htm http://www.support.intel/com/support/mothterboards/server/S C5275E/chassis_list.htm http://developer.intel.com/design/servers/smarttool/index.htm Intel® Entry Server Chassis SC5275-E User Guide iv Intel® Entry Server Chassis SC5275-E Quick Start User's Guide in -depth technical information about this...
... to spares, parts, and config guide) http://www.support.intel/com/support/mothterboards/server/S C5275E/tested_hwos.htm http://support.intel.com/support/motherboards/server/SC5275 E/os.htm http://www.support.intel/com/support/mothterboards/server/S C5275E/chassis_list.htm http://developer.intel.com/design/servers/smarttool/index.htm Intel® Entry Server Chassis SC5275-E User Guide iv Intel® Entry Server Chassis SC5275-E Quick Start User's Guide in -depth technical information about this...
User Guide
Page 5
...which may be installed in a Class B device. This is not available, provide some ESD protection by wearing an antistatic wrist Intel® Entry Server Chassis SC5275-E User Guide v Make sure the AC power cord is sold. If one is an FCC Class A device. EMC Testing Before computer ... of it . The suitability of the product and will void the UL listing and other regulatory approvals of this guide to the server before you open the chassis, add, or remove any other resource as : medical, industrial, telecommunications, NEBS, residential, alarm systems, test equipment...
...which may be installed in a Class B device. This is not available, provide some ESD protection by wearing an antistatic wrist Intel® Entry Server Chassis SC5275-E User Guide v Make sure the AC power cord is sold. If one is an FCC Class A device. EMC Testing Before computer ... of it . The suitability of the product and will void the UL listing and other regulatory approvals of this guide to the server before you open the chassis, add, or remove any other resource as : medical, industrial, telecommunications, NEBS, residential, alarm systems, test equipment...
User Guide
Page 6
... use to remove or install a jumper; Gripping the wide sides can be extremely sensitive to chassis groundany of the system, follow these steps: 1. Safety Cautions Read all cables connected to qualified personnel. Intel® Entry Server Chassis SC5275-E User Guide vi ESD and handling boards: Always handle boards carefully. After removing a board from its protective...
... use to remove or install a jumper; Gripping the wide sides can be extremely sensitive to chassis groundany of the system, follow these steps: 1. Safety Cautions Read all cables connected to qualified personnel. Intel® Entry Server Chassis SC5275-E User Guide vi ESD and handling boards: Always handle boards carefully. After removing a board from its protective...
User Guide
Page 7
...ventilated and away from strong electromagnetic fields produced by wearing an antistatic wrist strap attached to the system. Intel® Entry Server Chassis SC5275-E User Guide vii For proper cooling and airflow, always reinstall the chassis covers before turning on some electrostatic discharge (ESD) protection by electrical devices. Also, there may be ...Sicherheitshinweise in a typical office environment. Beachten Sie hierzu auch die Sicherheitshinweise zu IntelServerplatinen und -Servergehäusen unter http://support.intel.com/support/motherboards/server/safecert.htm.
...ventilated and away from strong electromagnetic fields produced by wearing an antistatic wrist strap attached to the system. Intel® Entry Server Chassis SC5275-E User Guide vii For proper cooling and airflow, always reinstall the chassis covers before turning on some electrostatic discharge (ESD) protection by electrical devices. Also, there may be ...Sicherheitshinweise in a typical office environment. Beachten Sie hierzu auch die Sicherheitshinweise zu IntelServerplatinen und -Servergehäusen unter http://support.intel.com/support/motherboards/server/safecert.htm.
User Guide
Page 15
... Drive 20 Connect Cables to the Server Board 23 Installing an Add-in Board ...24 Install the Front Bezel ...26 Install the Access Cover...27 3 Maintaining Your Server 29 Tools and Supplies Needed 29 Safety: Before You Remove the Access Cover(s 29 Warnings and Cautions...29 Replacing Fans ...31 Intel® Entry Server Chassis SC5275-E User Guide xv
... Drive 20 Connect Cables to the Server Board 23 Installing an Add-in Board ...24 Install the Front Bezel ...26 Install the Access Cover...27 3 Maintaining Your Server 29 Tools and Supplies Needed 29 Safety: Before You Remove the Access Cover(s 29 Warnings and Cautions...29 Replacing Fans ...31 Intel® Entry Server Chassis SC5275-E User Guide xv
User Guide
Page 16
... Liability 54 How to Obtain Warranty Service 55 Telephone Support...55 Returning a Defective Product 55 Figures Figure 1. Mechanical Locks ...7 Figure 3. Installing the I/O Shield 13 Intel® Entry Server Chassis SC5275-E User Guide xvi Removing the Access Cover 11 Figure 4. Screw Description...1 Figure 2. Removing the Front Bezel 12 Figure 5. Contents Replacing a Front System Fan 31 Replacing a Rear...
... Liability 54 How to Obtain Warranty Service 55 Telephone Support...55 Returning a Defective Product 55 Figures Figure 1. Mechanical Locks ...7 Figure 3. Installing the I/O Shield 13 Intel® Entry Server Chassis SC5275-E User Guide xvi Removing the Access Cover 11 Figure 4. Screw Description...1 Figure 2. Removing the Front Bezel 12 Figure 5. Contents Replacing a Front System Fan 31 Replacing a Rear...
User Guide
Page 17
... and Order Codes 5 Power Supply System Output Capability 39 Environmental Specifications 40 Power Usage Worksheet 1 43 Power Usage Worksheet 2 44 Product Certification Markings 46 Intel® Entry Server Chassis SC5275-E User Guide xvii Contents Figure 6. Attaching a Hard Drive to a Cage 21 Figure 13. Installing the Front Bezel 26 Figure 16. Replacing the AC Power Supply 33...
... and Order Codes 5 Power Supply System Output Capability 39 Environmental Specifications 40 Power Usage Worksheet 1 43 Power Usage Worksheet 2 44 Product Certification Markings 46 Intel® Entry Server Chassis SC5275-E User Guide xvii Contents Figure 6. Attaching a Hard Drive to a Cage 21 Figure 13. Installing the Front Bezel 26 Figure 16. Replacing the AC Power Supply 33...
User Guide
Page 19
...3.5-inch hard disk drives. Expansion Slot Up to seven expansion slots can be used; Cooling Two system fans inside the chassis and one power supply fan provide cooling and airflow. Hex head 6-32 x 6mm [.256] Figure 1. An optional hot...200] B. A hard drive bay cage designed to hold half-height standard removable media devices. Intel® Entry Server Chassis SC5275-E User Guide 1 1 Chassis Description 1 Chassis Description Kit Contents The chassis subassembly kit includes this product guide and a box that are externally accessible, designed to hold up to five 1-inch high,...
...3.5-inch hard disk drives. Expansion Slot Up to seven expansion slots can be used; Cooling Two system fans inside the chassis and one power supply fan provide cooling and airflow. Hex head 6-32 x 6mm [.256] Figure 1. An optional hot...200] B. A hard drive bay cage designed to hold half-height standard removable media devices. Intel® Entry Server Chassis SC5275-E User Guide 1 1 Chassis Description 1 Chassis Description Kit Contents The chassis subassembly kit includes this product guide and a box that are externally accessible, designed to hold up to five 1-inch high,...
User Guide
Page 20
Front panel controls and indicators B. 5.25-inch removable media drive bays C. 3.5-inch removable media drive bay D. Internal hard drive bay cage (behind door) E. Security lock F. USB port Intel® Entry Server Chassis SC5275-E User Guide 2 1 Chassis Description Chassis Front View A B C D E F TP00053 A.
Front panel controls and indicators B. 5.25-inch removable media drive bays C. 3.5-inch removable media drive bay D. Internal hard drive bay cage (behind door) E. Security lock F. USB port Intel® Entry Server Chassis SC5275-E User Guide 2 1 Chassis Description Chassis Front View A B C D E F TP00053 A.
User Guide
Page 21
...NIC 2 activity LED H. Hard drive activity LED I A. Table 2. Temperature or voltage non-critical fault Fatal error during POST Intel® Entry Server Chassis SC5275-E User Guide 3 NMI button D. LED Description LED Name Color Condition Power/Sleep LED Green ON Amber ON OFF LAN#1 Link/Act Green ON...activity Disconnected Hard drive activity Fault No activity System ready (not supported by all server boards) Processor or memory disabled Temperature or voltage critical fault; 1 Chassis Description Front Panel Controls and Indicators A B C D E F G H I . Sleep button F.
...NIC 2 activity LED H. Hard drive activity LED I A. Table 2. Temperature or voltage non-critical fault Fatal error during POST Intel® Entry Server Chassis SC5275-E User Guide 3 NMI button D. LED Description LED Name Color Condition Power/Sleep LED Green ON Amber ON OFF LAN#1 Link/Act Green ON...activity Disconnected Hard drive activity Fault No activity System ready (not supported by all server boards) Processor or memory disabled Temperature or voltage critical fault; 1 Chassis Description Front Panel Controls and Indicators A B C D E F G H I . Sleep button F.
User Guide
Page 22
Expansion slot covers H. Serial B port knockout J. Intel® Entry Server Chassis SC5275-E User Guide 4 Fan F. Location to install padlock loop K. Alternate Serial B port knockout B. 1 Chassis Description Chassis Rear View A B C D E F TP00834 A. AC input power connector D. Chassis intrusion switch * Items shown may be different in your chassis. ICMB or external SCSI knockout I /O ports* G. Alternate ICMB or external SCSI knockout C. Power supply E. I .
Expansion slot covers H. Serial B port knockout J. Intel® Entry Server Chassis SC5275-E User Guide 4 Fan F. Location to install padlock loop K. Alternate Serial B port knockout B. 1 Chassis Description Chassis Rear View A B C D E F TP00834 A. AC input power connector D. Chassis intrusion switch * Items shown may be different in your chassis. ICMB or external SCSI knockout I /O ports* G. Alternate ICMB or external SCSI knockout C. Power supply E. I .
User Guide
Page 23
... is not externally accessible. Order Code AXX6SCSIDB AXX6SATADB APT2WKTCOOLKIT AXX2ICMBKIT AXXEXTSCSICBL Intel® Entry Server Chassis SC5275-E User Guide 5 You can install up to two half-height peripherals. 3.5-inch Hard Drive Bays The chassis supports up to 18 Watts of spares and accessories, see http://www.intel.com/go/serverbuilder Table 3. The SCSI hot swap drive bay accepts...
... is not externally accessible. Order Code AXX6SCSIDB AXX6SATADB APT2WKTCOOLKIT AXX2ICMBKIT AXXEXTSCSICBL Intel® Entry Server Chassis SC5275-E User Guide 5 You can install up to two half-height peripherals. 3.5-inch Hard Drive Bays The chassis supports up to 18 Watts of spares and accessories, see http://www.intel.com/go/serverbuilder Table 3. The SCSI hot swap drive bay accepts...
User Guide
Page 24
... agency acceptable in your region. Intel® Entry Server Chassis SC5275-E User Guide 6 1 Chassis Description Power Supply The 600-Watt PFC non-redundant power supply is auto ranging for more information. Chassis Security To help prevent unauthorized entry or use of the server, the chassis includes one that is at the rear of the server. Monitoring One chassis intrusion switch is not compatible...
... agency acceptable in your region. Intel® Entry Server Chassis SC5275-E User Guide 6 1 Chassis Description Power Supply The 600-Watt PFC non-redundant power supply is auto ranging for more information. Chassis Security To help prevent unauthorized entry or use of the server, the chassis includes one that is at the rear of the server. Monitoring One chassis intrusion switch is not compatible...
User Guide
Page 25
A B A. Front bezel locked position Figure 2. 1 Chassis Description Mechanical Locks The front bezel has a two-position lock to prevent access to install padlock loop B. Location to the hard drives and the interior of the chassis. Mechanical Locks TP00055 Intel® Entry Server Chassis SC5275-E User Guide 7 A padlock loop is included with the chassis and can be installed at the rear of the chassis.
A B A. Front bezel locked position Figure 2. 1 Chassis Description Mechanical Locks The front bezel has a two-position lock to prevent access to install padlock loop B. Location to the hard drives and the interior of the chassis. Mechanical Locks TP00055 Intel® Entry Server Chassis SC5275-E User Guide 7 A padlock loop is included with the chassis and can be installed at the rear of the chassis.
User Guide
Page 27
... off all telecommunication lines connected to I/O connectors or ports on the front of the chassis. Intel® Entry Server Chassis SC5275-E User Guide 9 Follow these instructions, the UL listing will be void, and the product will most likely be non-compliant with this assembly. Tools and Supplies Needed ...
... off all telecommunication lines connected to I/O connectors or ports on the front of the chassis. Intel® Entry Server Chassis SC5275-E User Guide 9 Follow these instructions, the UL listing will be void, and the product will most likely be non-compliant with this assembly. Tools and Supplies Needed ...
User Guide
Page 28
... not available, provide some ESD protection by wearing an antistatic wrist strap attached to ESD. They can damage system parts. Intel® Entry Server Chassis SC5275-E User Guide 10 servicing should integrate and configure the server. For proper cooling and airflow, always install the access cover before opening it without the cover in this will result in...
... not available, provide some ESD protection by wearing an antistatic wrist strap attached to ESD. They can damage system parts. Intel® Entry Server Chassis SC5275-E User Guide 10 servicing should integrate and configure the server. For proper cooling and airflow, always install the access cover before opening it without the cover in this will result in...
User Guide
Page 29
...2 1 1 3 2 TP00057 Figure 3. Removing the Access Cover Intel® Entry Server Chassis SC5275-E User Guide 11 Slide the cover backward a short distance, until it stops (number 3 in the figure below). 2. For ease of installation, before beginning lay the chassis on its right side, with the left to disengage the rows of...the figure). 3. Pull the entire cover upward, straight away from the chassis, to the unlocked position (number 2 in the top and bottom edges of this chapter. 2 Setting Up the Chassis Remove the Access Cover Observe the safety and ESD precautions at the beginning...
...2 1 1 3 2 TP00057 Figure 3. Removing the Access Cover Intel® Entry Server Chassis SC5275-E User Guide 11 Slide the cover backward a short distance, until it stops (number 3 in the figure below). 2. For ease of installation, before beginning lay the chassis on its right side, with the left to disengage the rows of...the figure). 3. Pull the entire cover upward, straight away from the chassis, to the unlocked position (number 2 in the top and bottom edges of this chapter. 2 Setting Up the Chassis Remove the Access Cover Observe the safety and ESD precautions at the beginning...