Hardware User Guide
Page 5
......29 Drive Migration ...30 C. Regulatory and Certification Information 31 Electromagnetic Compatibility Notices 33 Intel® RAID Controller RS2WC040 Hardware User's Guide v Table of Contents Preface ...iii Audience ...iii Organization ...iii Related Publication... Intel® RAID Controller RS2WC040 Hardware Installation 7 Requirements ...7 Installing the RAID Controller 7 Configuring the RAID Controller 11 Replacing a Controller ...11 Resolving a Configuration Mismatch 11 Chapter 3, Intel® RAID Controller RS2WC040 Characteristics 13 Technical Specifications ...14 Array Performance Features...
......29 Drive Migration ...30 C. Regulatory and Certification Information 31 Electromagnetic Compatibility Notices 33 Intel® RAID Controller RS2WC040 Hardware User's Guide v Table of Contents Preface ...iii Audience ...iii Organization ...iii Related Publication... Intel® RAID Controller RS2WC040 Hardware Installation 7 Requirements ...7 Installing the RAID Controller 7 Configuring the RAID Controller 11 Replacing a Controller ...11 Resolving a Configuration Mismatch 11 Chapter 3, Intel® RAID Controller RS2WC040 Characteristics 13 Technical Specifications ...14 Array Performance Features...
Hardware User Guide
Page 9
List of Tables Table 1. Array Performance Features 14 Table 4. Technical Specifications 14 Table 3. Fault Tolerance Features 15 Table 5. Electrical Characteristics 17 Intel® RAID Controller RS2WC040 Hardware User's Guide ix Jumper Description 13 Table 2.
List of Tables Table 1. Array Performance Features 14 Table 4. Technical Specifications 14 Table 3. Fault Tolerance Features 15 Table 5. Electrical Characteristics 17 Intel® RAID Controller RS2WC040 Hardware User's Guide ix Jumper Description 13 Table 2.
Hardware User Guide
Page 11
...Serial ATA technology. The SAS/SATA connector and cable are serial, point-to additional drives. The SAS interface provides improved performance, simplified cabling, smaller connectors, lower pin count, and lower power requirements than parallel SCSI. SAS controllers leverage a common...workstation storage markets. This is a RAID solution that is compatible with existing ATA firmware. Intel® RAID Controller RS2WC040 Hardware User's Guide 1 1 Overview The Intel® RAID Controller RS2WC040 is an intelligent PCI Express* 2.0-compliant SAS/SATA II RAID controller that use simplified ...
...Serial ATA technology. The SAS/SATA connector and cable are serial, point-to additional drives. The SAS interface provides improved performance, simplified cabling, smaller connectors, lower pin count, and lower power requirements than parallel SCSI. SAS controllers leverage a common...workstation storage markets. This is a RAID solution that is compatible with existing ATA firmware. Intel® RAID Controller RS2WC040 Hardware User's Guide 1 1 Overview The Intel® RAID Controller RS2WC040 is an intelligent PCI Express* 2.0-compliant SAS/SATA II RAID controller that use simplified ...
Hardware User Guide
Page 12
...Protocol (STP) support for SATA II through expander interfaces. Drives not configured as part of performance up to 5 Gb/s per lane. Intel® RAID Controller RS2WC040 The Intel® RAID Controller RS2WC040 is an extension to SATA 1.0a. The SAS RAID controllers support the SAS protocol as ...*, and Windows Vista*. • Red Hat* Enterprise Linux 4.0, and 5.0. • SuSE* Linux Enterprise Server 10 and 11. 2 Intel® RAID Controller RS2WC040 Hardware User's Guide SATA II is a PCI* Express 2.0, half-size, low profile RAID controller based on the SAS controllers supports SAS ...
...Protocol (STP) support for SATA II through expander interfaces. Drives not configured as part of performance up to 5 Gb/s per lane. Intel® RAID Controller RS2WC040 The Intel® RAID Controller RS2WC040 is an extension to SATA 1.0a. The SAS RAID controllers support the SAS protocol as ...*, and Windows Vista*. • Red Hat* Enterprise Linux 4.0, and 5.0. • SuSE* Linux Enterprise Server 10 and 11. 2 Intel® RAID Controller RS2WC040 Hardware User's Guide SATA II is a PCI* Express 2.0, half-size, low profile RAID controller based on the SAS controllers supports SAS ...
Hardware User Guide
Page 14
CIM, LEDs. • Cache options: - Configuration stored in a RAID 5 array, which optimizes performance by the RAID adapter. • Supports SSP to enable communication with transparent rebuild. SAS/SATA Features of the LSISAS2008 Controller • Provides...disks). • Support the internal SAS Sideband signal SFF-8485 (SGPIO) interface. • Auto-detection of failed drives with other SAS devices. 4 Intel® RAID Controller RS2WC040 Hardware User's Guide There must be disk activity (I /O only - RW: allow read and write I /O: Reads data directly from disk without checking ...
CIM, LEDs. • Cache options: - Configuration stored in a RAID 5 array, which optimizes performance by the RAID adapter. • Supports SSP to enable communication with transparent rebuild. SAS/SATA Features of the LSISAS2008 Controller • Provides...disks). • Support the internal SAS Sideband signal SFF-8485 (SGPIO) interface. • Auto-detection of failed drives with other SAS devices. 4 Intel® RAID Controller RS2WC040 Hardware User's Guide There must be disk activity (I /O only - RW: allow read and write I /O: Reads data directly from disk without checking ...
Hardware User Guide
Page 24
Array Performance Features Specification Host data transfer rate Drive data transfer rate Maximum scatter / gather Intel® RAID Controller RS2WC040 Up to 5.0 Gb/s per PCI Express* lane Up to 16 RAID arrays per controller Drives not configured as ... to host SAS/SATA bus speed SAS/SATA ports Physical and virtual drive support Firmware Compatible devices Cabling Redundant configuration Enclosure management Enclosure support Intel® RAID Controller RS2WC040 LSI*SAS2008 PCI*Express-SAS/SATA I/O Processor chip, 150MHz +3.3 V, +12 V Low profile, extended half-length (6.6" x 2.731") ...
Array Performance Features Specification Host data transfer rate Drive data transfer rate Maximum scatter / gather Intel® RAID Controller RS2WC040 Up to 5.0 Gb/s per PCI Express* lane Up to 16 RAID arrays per controller Drives not configured as ... to host SAS/SATA bus speed SAS/SATA ports Physical and virtual drive support Firmware Compatible devices Cabling Redundant configuration Enclosure management Enclosure support Intel® RAID Controller RS2WC040 LSI*SAS2008 PCI*Express-SAS/SATA I/O Processor chip, 150MHz +3.3 V, +12 V Low profile, extended half-length (6.6" x 2.731") ...
Hardware User Guide
Page 25
... Features Specification Self Monitoring Analysis and Reporting Technology (SMART) support Drive Replacement Drive Rebuild Using Hot Spares Intel® RAID Controller RS2WC040 • Detects up to 70% of predictable disk drive failures • Monitors the internal performance of all motors, heads, and drive electronics. • Auto detection of failure • Hot plug •...
... Features Specification Self Monitoring Analysis and Reporting Technology (SMART) support Drive Replacement Drive Rebuild Using Hot Spares Intel® RAID Controller RS2WC040 • Detects up to 70% of predictable disk drive failures • Monitors the internal performance of all motors, heads, and drive electronics. • Auto detection of failure • Hot plug •...
Hardware User Guide
Page 26
Specification Self Monitoring Analysis and Reporting Technology (SMART) support Error Checking and Indication Intel® RAID Controller RS2WC040 • Detects up to 70% of predictable disk drive failures • Monitors the internal performance of all motors, heads, and drive electronics. • Parity generation and checking, automatic consistency checking • Patrol reads • Activity and fault LEDs • Multiple retries • Logs in NVRAM, event log, CIM, S.M.A.R.T, Intel® RAID Web Console 2 16 Intel® RAID Controller RS2WC040 Hardware User's Guide
Specification Self Monitoring Analysis and Reporting Technology (SMART) support Error Checking and Indication Intel® RAID Controller RS2WC040 • Detects up to 70% of predictable disk drive failures • Monitors the internal performance of all motors, heads, and drive electronics. • Parity generation and checking, automatic consistency checking • Patrol reads • Activity and fault LEDs • Multiple retries • Logs in NVRAM, event log, CIM, S.M.A.R.T, Intel® RAID Web Console 2 16 Intel® RAID Controller RS2WC040 Hardware User's Guide
Hardware User Guide
Page 31
... 4. Remove the cover(s). The power button on the Resource CD and/or at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Intel® RAID Controller RS2WC040 Hardware User's Guide 21 English Read all caution and safety statements in this : 1. Unplug ...all peripheral devices connected to the system. Turn off all AC power cords from the system or from the back of the instructions. For proper cooling and airflow, always reinstall the chassis covers before performing...
... 4. Remove the cover(s). The power button on the Resource CD and/or at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Intel® RAID Controller RS2WC040 Hardware User's Guide 21 English Read all caution and safety statements in this : 1. Unplug ...all peripheral devices connected to the system. Turn off all AC power cords from the system or from the back of the instructions. For proper cooling and airflow, always reinstall the chassis covers before performing...