Instruction Manual - Page 1
INSTRUCTION MANUAL
VHF MOBILE TRANSCEIVERS
iF5010
Series
UHF MOBILE TRANSCEIVERS
iF6010
Series
Limited functions only
Instruction Manual - Page 2
This
instruction manual contains important opera ting instructions for a Class A digital device, pursuant to part 15 of the FCC Rules.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the limits for the IC-F5011, IC-F5013, IC-F5013H VHF MOBILE TRANSCEIVERS and the IC-F6011, IC-F6013, IC-F6013H UHF MOBILE ...
Instruction Manual - Page 3
... place the transceiver in areas with equipment that is not manufactured or approved by Icom. DO NOT place the transceiver against walls. BE CAREFUL!
NEVER connect the transceiver...use harsh solvents such as benzine or alcohol
when cleaning, as the dashboard. ronments.
Approved Icom optional equipment is not responsible for optimal performance when used with tem- peratures below -30...
Instruction Manual - Page 4
... ON the power 7 ■ Channel selection 7 ■ Call procedure 8 ■ Receiving and transmitting 8 ■ User Set mode 10 ■ Scrambler function 11 ■ Stun function 11 ■ Priority A channel selection 11 ■ Emergency transmission ...15 ■ Antenna 16 ■ Fuse replacement 16 ■ Cleaning 16 ■ Options 16
4 SAFETY TRAINING INFORMATION 17-19
iii
Instruction Manual - Page 5
... audio output level. Password prompt
14
NEVER connect non-specified microphones. 1 PANEL DESCRIPTION
■ Front panel
1
q
Function LED (p. 2)
Speaker
2
3
4
1
2
3
4
5
TX/RX
6
7
P0 P1 P2 P3
8
9
w
e
r
10
11
q AF VOLUME CONTROL KNOB [VOL] Rotate the knob to turn the power ON or OFF.
12
• Minimum audio level is pre-set. (p. 10)
•...
Instruction Manual - Page 6
... scan start when you put it ON hook. - Sets to 'Inaudible' mode (muted state) when you take...Automatically selects the Priority A channel when you take it OFF
hook. - Sets to 'Audible' mode (unmuted state) when you take it ON hook. -... signal during a scan. ➥ All LEDs blink while entering the power ON password. e ACTIVATED KEY INDICATORS (P0/P1/P2) Lights when a pre-programmed key ...
Instruction Manual - Page 7
... Channel A or B. ➥ To rewrite the operating channel as Priority A or Priority
3
cerning your Icom dealer or system operator for
4
CH UP AND DOWN KEYS
1 second.
5
Push to the muted state
.../DEL (TAG) KEY While scan is cancelled.
➥ Hold down to send a 'reset code' after the communication is cancelled except by pushing this key, the cancelled scan resumes after the scan...
Instruction Manual - Page 9
... other than an emergency alert, such as a security alarm for 1 second again to exit the User Set
SIREN
mode. This function can be stopped by turning OFF the transceiver
OPT 1/2/3 OUT KEYS Push to...this key to enable the function.
5 Ask your dealer for 1 second to enter the User Set mode. ing down for details.
power.
HOOK SCAN When the Hook Scan function is turned ON, the ...
Instruction Manual - Page 11
...may
2
w I f all channel indicator LEDs still blink after inputting 4 digits, the input code number may be used for password input:
Push [CH Up] or [CH Down] to sequentially select the desired
4
The ...stops when a signal is detected.
9
10
e I f the transceiver is programmed for a start up password,
differ, according to your system set up.
3
input the digit codes as identical.
Instruction Manual - Page 14
... items are preset by your preferences
lected item
and operating style. When the minimum value or "OFF" is selected, an error beep sounds if [P2] is pushed.
e P ush and hold [User Set Mode] for 1 second to 5
Horn
: OFF/ON
Signal Moni : OFF/ON
Channel indicator
Lone Worker : OFF/ON - Pushing [P3] increases...
Instruction Manual - Page 16
...certain emergency call operation.
D NOTES
Depending on the preprogramming, receiving a matching 5-tone code cancels the transmission. The repeat emergency signal is transmitted on the operating channel. Depending ...for Silent operation, you turn OFF the power. IMPORTANT: It is recommended to set an emergency channel individually to cancel the Emergency function, hold down for a specified...
Instruction Manual - Page 19
...9632; Supplied Accessories
Microphone
Microphone hanger Microphone
and screw set
hanger cable
DC power cable
Function name stickers*
...ceiver also allows overhead mounting.
3
• Mount the transceiver securely with the 4 supplied screws
to a thick surface which can support more than 1.5 kg
4
(3.3 lb).
5
Flat washer
6
7
8
9
Felt*
10
Spring washer
11
12
13
14
15
...
Instruction Manual - Page 20
... pager and code squelch capabilities....problem if possible, repaire it clean with a new rated one. *Depending on the version, only 1 fuse holder may be attached. ❑ Fuse rating: 10 A (for 1 fuse holder)/20 A (for more information regarding antennas and how to -install.
USE only a 20 A fuse. OPC-1132A : 3 m (9.8 ft) OPC-347 : 7 m (23 ft)
■ Fuse replacement
A fuse is installed...
Instruction Manual - Page 21
.... the properly installed antenna. recommended minimum distance of 37 centimeters or more between the trans- IC-F5011/IC-F5013H: The antenna is met, the installation of the antenna...This separation distance will en- IC-F6011/IC-F6013H:
14
The antenna is sufficient distance from a properly installed
7
1. 4 SAFETY TRAINING INFORMATION
Your Icom radio generates RF electromagnetic energy...