Instruction Manual
Page 8
TABLE OF CONTENTS ■ Calling a specific station 103 D Confirming the setting 105 D Settings for "UR" and "R2," depending on the communication form 105 ■ Simplex operation using the VFO 106 D Making a ...
TABLE OF CONTENTS ■ Calling a specific station 103 D Confirming the setting 105 D Settings for "UR" and "R2," depending on the communication form 105 ■ Simplex operation using the VFO 106 D Making a ...
Instruction Manual
Page 9
... MODE 161-170 D Command table 184 D Data content description 190 7 ■ Set mode description 161 D The Set mode settings 161 19 SPECIFICATIONS 197-198 8 ■ Tone control Set mode description 169 D The Tone control Set mode settings.......... 169 ■ General 197 ■ Transmitter...173 D Not using a measuring device 173 15 16 OPTION INSTALLATION 174-176 16 ■ Opening the transceiver's case 174 ■ UX-9100 1200 MHz band unit installation....... 175 17 ■ FL-430/FL-431 1st if filter installation. ....... 176 ■ UT-121 digital ...
... MODE 161-170 D Command table 184 D Data content description 190 7 ■ Set mode description 161 D The Set mode settings 161 19 SPECIFICATIONS 197-198 8 ■ Tone control Set mode description 169 D The Tone control Set mode settings.......... 169 ■ General 197 ■ Transmitter...173 D Not using a measuring device 173 15 16 OPTION INSTALLATION 174-176 16 ■ Opening the transceiver's case 174 ■ UX-9100 1200 MHz band unit installation....... 175 17 ■ FL-430/FL-431 1st if filter installation. ....... 176 ■ UT-121 digital ...
Instruction Manual
Page 22
...Be sure to check its switching action before operation. [Example] ACC socket eHSEND or uVSEND i13.8 V Switching diode Relay To a non-Icom linear amplifier *2 V SEND is used for the 144 MHz, 430 MHz, and 1200 MHz bands, and HSEND is used for the MAIN... a counter-electromotive force can change this setting in "VSEND Select" of the supplied cable. PIN No. 1 2 3 4 5 6 7 8 9 10 11 12 13 NAME DESCRIPTION SPECIFICATIONS 8 V Regulated 8 V output. Control voltage Input impedance : -3 V to 0 V : More than 2 mA MOD Modulator input. of the relay may occur. the transceiver trans-...
...Be sure to check its switching action before operation. [Example] ACC socket eHSEND or uVSEND i13.8 V Switching diode Relay To a non-Icom linear amplifier *2 V SEND is used for the 144 MHz, 430 MHz, and 1200 MHz bands, and HSEND is used for the MAIN... a counter-electromotive force can change this setting in "VSEND Select" of the supplied cable. PIN No. 1 2 3 4 5 6 7 8 9 10 11 12 13 NAME DESCRIPTION SPECIFICATIONS 8 V Regulated 8 V output. Control voltage Input impedance : -3 V to 0 V : More than 2 mA MOD Modulator input. of the relay may occur. the transceiver trans-...
Instruction Manual
Page 23
... t AF y SQLS u 13.8 V i ALC ACC 2 4 25 1 3 6 7 q 8 V w GND e HSEND r BAND t ALC y VSEND u 13.8 V D DATA2 socket information DATA2 qw e r ty Rear panel view PIN No. 1 2 3 4 5 6 NAME DESCRIPTION SPECIFICATIONS DATA IN Input terminal for data transmit. (1200 bps: AFSK/ 9600 bps: G3RUH, GMSK) Input level (1200 bps) : 100 mV Input level (9600 bps) : 0.2 to...
... t AF y SQLS u 13.8 V i ALC ACC 2 4 25 1 3 6 7 q 8 V w GND e HSEND r BAND t ALC y VSEND u 13.8 V D DATA2 socket information DATA2 qw e r ty Rear panel view PIN No. 1 2 3 4 5 6 NAME DESCRIPTION SPECIFICATIONS DATA IN Input terminal for data transmit. (1200 bps: AFSK/ 9600 bps: G3RUH, GMSK) Input level (1200 bps) : 100 mV Input level (9600 bps) : 0.2 to...
Instruction Manual
Page 63
... level limit. Keyer Repeat Time (Default: 2s) When sending CW using the repeat timer, set the CW sidetone, memory keyer repeat time, dash weight, paddle specifications, keyer type, etc. • Setting contents q In the CW mode, push [MENU] to display the "M1" screen (Menu 1). Rise Time (Default: 4ms) Set the rise time...
... level limit. Keyer Repeat Time (Default: 2s) When sending CW using the repeat timer, set the CW sidetone, memory keyer repeat time, dash weight, paddle specifications, keyer type, etc. • Setting contents q In the CW mode, push [MENU] to display the "M1" screen (Menu 1). Rise Time (Default: 4ms) Set the rise time...
Instruction Manual
Page 95
... [MENU] one or more times to display the "M3" screen (Menu 3). • In the DR mode, push [MENU] once or twice to a specific individual station or a repeater, for both digital voice and low-speed data communications. i P ush [Ω](F-2) to move the cursor forwards. If all call sign memories...sign programming mode. • A cursor appears and blinks. r P ush [Z](F-1) one or more times to the "CS" screen. ✔ For your information The IC-9100 has a call sign setting). o Repeat step u to enter UR call sign. • A call sign of up to 8 digits can be over-written anytime,...
... [MENU] one or more times to display the "M3" screen (Menu 3). • In the DR mode, push [MENU] once or twice to a specific individual station or a repeater, for both digital voice and low-speed data communications. i P ush [Ω](F-2) to move the cursor forwards. If all call sign memories...sign programming mode. • A cursor appears and blinks. r P ush [Z](F-1) one or more times to the "CS" screen. ✔ For your information The IC-9100 has a call sign setting). o Repeat step u to enter UR call sign. • A call sign of up to 8 digits can be over-written anytime,...
Instruction Manual
Page 108
...To call sign Calling CQ Through an access repeater : CQCQCQ Through a zone link repeater or gateway repeater : Zone link repeater or Gateway repeater name Calling a specific station Step 3: (R2 selection) Select a zone link or gateway repeater. D1 R 1: H I R A N O 4 3 GRP3 CS C D ...CS C D R > C S U R DSET UR call sign (CQ) selection D1 U R: J G 3 Y M K UR CS C D R > C S U R DSET UR call sign (specific station) selection D1 R 2: N A R A 4 3 CS CD R>CS UR DSET R2 (destination repeater) selection D Communication Form • Local area call (pp. 101, 103) To call a station ...
...To call sign Calling CQ Through an access repeater : CQCQCQ Through a zone link repeater or gateway repeater : Zone link repeater or Gateway repeater name Calling a specific station Step 3: (R2 selection) Select a zone link or gateway repeater. D1 R 1: H I R A N O 4 3 GRP3 CS C D ...CS C D R > C S U R DSET UR call sign (CQ) selection D1 U R: J G 3 Y M K UR CS C D R > C S U R DSET UR call sign (specific station) selection D1 R 2: N A R A 4 3 CS CD R>CS UR DSET R2 (destination repeater) selection D Communication Form • Local area call (pp. 101, 103) To call a station ...
Instruction Manual
Page 112
.... (or [TRANSMIT] on the SUB Band to enter the UR call to an individual station through the internet. 8 DV MODE OPERATION ■ Calling a specific station This section describes how to enter the memory select write mode. (p. 102) [UR] [TS•GRP] [DV•DR] [MAIN DIAL] [...selec- t R otate [MAIN DIAL] to select "NOT USE✱." Making a call sign selection mode. i P ush [UR](F-4) to a specific station through your own call a specific station using the DR mode. tion mode. When the Link repeater (R2) is set to "GW," the designated gateway repeater is the same...
.... (or [TRANSMIT] on the SUB Band to enter the UR call to an individual station through the internet. 8 DV MODE OPERATION ■ Calling a specific station This section describes how to enter the memory select write mode. (p. 102) [UR] [TS•GRP] [DV•DR] [MAIN DIAL] [...selec- t R otate [MAIN DIAL] to select "NOT USE✱." Making a call sign selection mode. i P ush [UR](F-4) to a specific station through your own call a specific station using the DR mode. tion mode. When the Link repeater (R2) is set to "GW," the designated gateway repeater is the same...
Instruction Manual
Page 114
...: R1 setting is set to your access repeater's call sign setting. w P ush [CS](F-1) to display the "CS" screen (Call Sign). 8 DV MODE OPERATION ■ Calling a specific station (Continued) D Confirming the setting q In the DR mode, push [MENU] one or more times to display the "D1" screen.
...: R1 setting is set to your access repeater's call sign setting. w P ush [CS](F-1) to display the "CS" screen (Call Sign). 8 DV MODE OPERATION ■ Calling a specific station (Continued) D Confirming the setting q In the DR mode, push [MENU] one or more times to display the "D1" screen.
Instruction Manual
Page 206
...operation. ‡ Only when the 1200 MHz frequency band is required. • No. of call channels : 3CH (1 × 3 band) (4CH with UX-9100‡; 6CH × 4 bands) • N o. of Satellite memory channels : 20CH • Antenna connector : SO-239 × 3 Type-N × ...; Frequency resolution : 1 Hz • Power supply : 13.8 V DC ±15% (negative ground) • Power consumption Transmit Max. 19 SPECIFICATIONS ■ General • Frequency coverage : (unit: MHz) Receive 0.030-60.000*1*2 136.000-174.000*1*2 420.000-480.000*1*2 1240.000...
...operation. ‡ Only when the 1200 MHz frequency band is required. • No. of call channels : 3CH (1 × 3 band) (4CH with UX-9100‡; 6CH × 4 bands) • N o. of Satellite memory channels : 20CH • Antenna connector : SO-239 × 3 Type-N × ...; Frequency resolution : 1 Hz • Power supply : 13.8 V DC ±15% (negative ground) • Power consumption Transmit Max. 19 SPECIFICATIONS ■ General • Frequency coverage : (unit: MHz) Receive 0.030-60.000*1*2 136.000-174.000*1*2 420.000-480.000*1*2 1240.000...
Instruction Manual
Page 207
SPECIFICATIONS 19 ■ Receiver • Receive system HF/50/144/430 MHz band: Double superheterodyne system 1200 MHz band† : Triple superheterodyne system • Intermediate frequencies ... bands) power 15 W (50MHz band ) • Tuning accuracy : VSWR 1:1.5 or less • Insertion loss : Less than 1.0 dB (after tuning at RF power 100 W) All stated specifications are typical and subject to change without notice or obligation. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 198
SPECIFICATIONS 19 ■ Receiver • Receive system HF/50/144/430 MHz band: Double superheterodyne system 1200 MHz band† : Triple superheterodyne system • Intermediate frequencies ... bands) power 15 W (50MHz band ) • Tuning accuracy : VSWR 1:1.5 or less • Insertion loss : Less than 1.0 dB (after tuning at RF power 100 W) All stated specifications are typical and subject to change without notice or obligation. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 198
Instruction Manual
Page 211
... of issue Icom (Europe) GmbH Communication Equipment Auf der Krautweide 24, 65812 Bad Soden am Taunus, Germany Authorized representative name Y. Kind of equipment: HF/VHF/UHF TRANSCEIVER Type-designation: iC- 9100 Version (where applicable): This compliance is based on our sole responsibility that this equipment complies with the following harmonised standards, specifications or documents...
... of issue Icom (Europe) GmbH Communication Equipment Auf der Krautweide 24, 65812 Bad Soden am Taunus, Germany Authorized representative name Y. Kind of equipment: HF/VHF/UHF TRANSCEIVER Type-designation: iC- 9100 Version (where applicable): This compliance is based on our sole responsibility that this equipment complies with the following harmonised standards, specifications or documents...