Installation Guide
Page 19
...because of server - PCI and PCI-X expansion slots: v Six PCI expansion slots - Two PCI-X 2.0 133 MHz/64-bit slots Upgradeable microcode: System BIOS, service microprocessor, BMC, and SAS microcode Power supply: Note: To upgrade to 80% Heat output: Approximate heat output in a given location... IDE: - Height: 440 mm (17.3 in .) - Width: 424 mm (16.7 in .) - altitude: 0 to 140.4°F); Server off : 8% to two 835-watt hot-swap power supplies, install the redundant power and cooling option kit. Maximum: 0.88 kVA Notes: 1. Power consumption and heat output vary depending on the...
...because of server - PCI and PCI-X expansion slots: v Six PCI expansion slots - Two PCI-X 2.0 133 MHz/64-bit slots Upgradeable microcode: System BIOS, service microprocessor, BMC, and SAS microcode Power supply: Note: To upgrade to 80% Heat output: Approximate heat output in a given location... IDE: - Height: 440 mm (17.3 in .) - Width: 424 mm (16.7 in .) - altitude: 0 to 140.4°F); Server off : 8% to two 835-watt hot-swap power supplies, install the redundant power and cooling option kit. Maximum: 0.88 kVA Notes: 1. Power consumption and heat output vary depending on the...
Installation Guide
Page 33
... push the baffle to internal server components when the server is powered-on page 9. Installing redundant power and cooling You can install a second 835-watt hot-swap power supply. Remove the left and lift it out of the air baffle; To install the redundant power and cooling option, complete the... devices, and disconnect the power cords and all adapters. To avoid this potential problem, always use an electrostatic-discharge wrist strap or other grounding system when you work inside the server with an air duct and a single hot-swap fan, and a fan power cable. Remove the fan air...
... push the baffle to internal server components when the server is powered-on page 9. Installing redundant power and cooling You can install a second 835-watt hot-swap power supply. Remove the left and lift it out of the air baffle; To install the redundant power and cooling option, complete the... devices, and disconnect the power cords and all adapters. To avoid this potential problem, always use an electrostatic-discharge wrist strap or other grounding system when you work inside the server with an air duct and a single hot-swap fan, and a fan power cable. Remove the fan air...
User Guide
Page 17
...average stated values because of computers will not start without a RAID controller installed. - Two PCI-X 2.0 133 MHz/64-bit slots Upgradeable microcode: System BIOS, service microprocessor, BMC, and SAS microcode Power supply: Note: To upgrade to 2134 m (7000 ft) - Kit includes one x4 link...: v Minimum: 1 GB depending on the server model, some specifications might not apply. The System x3500 server 3 v Standard: One 835-watt 110 V or 240 V ac input dual-rated power supply v Upgradeable to two 835-watt hot-swap power supplies Hot-swap fans: v Three (standard) v Upgradeable to six fans ...
...average stated values because of computers will not start without a RAID controller installed. - Two PCI-X 2.0 133 MHz/64-bit slots Upgradeable microcode: System BIOS, service microprocessor, BMC, and SAS microcode Power supply: Note: To upgrade to 2134 m (7000 ft) - Kit includes one x4 link...: v Minimum: 1 GB depending on the server model, some specifications might not apply. The System x3500 server 3 v Standard: One 835-watt 110 V or 240 V ac input dual-rated power supply v Upgradeable to two 835-watt hot-swap power supplies Hot-swap fans: v Three (standard) v Upgradeable to six fans ...
User Guide
Page 19
... for PCI-X 64-bit adapters. v ServeRAID™ support The server supports ServeRAID adapters to create redundant array of the fans fails. The System x3500 server 5 Reliability, availability, and serviceability Three important server design features are reliability, availability, and serviceability (RAS). v Symmetric multiprocessing (SMP)... performance and provide SMP capability. The RAS features help to ensure the integrity of the data that is less than 835 watts and a problem occurs with the server, you can manage the functions of the power supplies, the other power supply can...
... for PCI-X 64-bit adapters. v ServeRAID™ support The server supports ServeRAID adapters to create redundant array of the fans fails. The System x3500 server 5 Reliability, availability, and serviceability Three important server design features are reliability, availability, and serviceability (RAS). v Symmetric multiprocessing (SMP)... performance and provide SMP capability. The RAS features help to ensure the integrity of the data that is less than 835 watts and a problem occurs with the server, you can manage the functions of the power supplies, the other power supply can...
User Guide
Page 56
...the connector. Read the safety information that the keys align with an air duct and a single hot-swap fan. Fan air baffle 42 IBM System x3500 Type 7977: User's Guide Hot-swap fan Turn the VRM so that begins on page v and "Installation guidelines" on page 46. Installing redundant power... and cooling You can install a second 835-watt hot-swap power-supply. To install the redundant power and cooling option, complete the following steps: 1. ...
...the connector. Read the safety information that the keys align with an air duct and a single hot-swap fan. Fan air baffle 42 IBM System x3500 Type 7977: User's Guide Hot-swap fan Turn the VRM so that begins on page v and "Installation guidelines" on page 46. Installing redundant power... and cooling You can install a second 835-watt hot-swap power-supply. To install the redundant power and cooling option, complete the following steps: 1. ...