IBM 866631Y - Netfinity 7100 - 8666 Support and Manuals
Popular IBM 866631Y Manual Pages
Hardware Maintenance Manual - Page 8
... 141 Host Built-In Self Test (BIST) checkout . . . . . 141 I2C bus fault messages 141 Undetermined problems 142
Parts listing (Type 8666 145
Part A 145 System 146
Part B 147 System 148 Keyboards 149 Power cords 150
Related service information . . . . . 151
Safety information 152 General safety 152 Electrical safety 152
vi Hardware Maintenance Manual: Netfinity 7100 - Type 8666
Hardware Maintenance Manual - Page 36
... software settings.
26 Hardware Maintenance Manual: Netfinity 7100 - PCNTNW-NW-074 The hardware interrupt cannot be registered with another specified mode. Explanation: An attempt was not successful. Action:Verify that conflicts with the Link Support Layer (LSL). PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be set.
Explanation: An error occurred while the driver was...
Hardware Maintenance Manual - Page 39
...-17
Explanation:The SunSoft Solaris driver cannot find any more devices to the interrupt request (IRQ) that fails to match the hardware settings
add_intr_handler failed! If the problem persists, run the NETCONFIG program to respond. Action:Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the Ethernet adapter that was...
Hardware Maintenance Manual - Page 46
... access to access the Configuration/Setup Utility
program. This limited access might include changing or deleting the power-on the server.
36 Hardware Maintenance Manual: Netfinity 7100 - Administrator password
Select this choice to be changed by the user. You must replace the I/O Legacy board.
Note: If the server has a RAID adapter installed, use to: v View the...
Hardware Maintenance Manual - Page 54
... " on page 43.
44 Hardware Maintenance Manual: Netfinity 7100 - v Review the information in the server identifies hot-swap components. do not need to turn off the server to install.
Note: If you upgrade the server by installing a RAID adapter, you must configure the disk arrays after installing the drives. Type 8666
v You do not wear cufflinks while...
Hardware Maintenance Manual - Page 70
You can connect the cable-management arm after installing the power supply. If you suspect a problem with the option.
60 Hardware Maintenance Manual: Netfinity 7100 - Before you must have a rack model, before you install a power supply in "Before you continue with the power supply-installation procedure, review the following. v Read the documentation that comes with one of ...
Hardware Maintenance Manual - Page 82
... redundant pair is , the Ethernet controller will adjust to set any other network operation.
72 Hardware Maintenance Manual: Netfinity 7100 - In failover mode, if the primary Ethernet controller detects a link failure, all Ethernet traffic associated with an integrated Ethernet controller. Note that you can install in the network be Category 5 or higher.
That is...
Hardware Maintenance Manual - Page 87
... a set of Netfinity Manager services that enables you to export data collected by System Information Tool, System Profile, Software Inventory, and System Monitor to enhance the hardware systems-management capabilities of system-specific installations. For information on how to install only the Client Services for Netfinity Manager, see the Client Services for Netfinity Manager User 's Guide...
Hardware Maintenance Manual - Page 88
... and Windows 98 system requirements" on page 80.
78 Hardware Maintenance Manual: Netfinity 7100 - Managing your IBM Netfinity server with any system that is established, the Netfinity Manager has full access to Netfinity Manager services, just as a system-management console, and then install Client Services for Netfinity Manager. To use Netfinity Manager to monitor and manage...
Hardware Maintenance Manual - Page 92
... the Advanced System Management service on this system. The available installation options are: v Advanced System Management Support Click Advanced System Management Support to save these settings and open the Netfinity Manager Installation Program window.
7. Use this system. For more information on the network.
82 Hardware Maintenance Manual: Netfinity 7100 - Type in the Directory...
Hardware Maintenance Manual - Page 114
... SCO UnixWare User's Guide
Description
Detailed information on the Advanced System Management and Dynamic Connection Manager services.
Updated information on how to use Client Services for customization, installation, and distribution) software distribution manager utility (such as LAN CID, included with this directory.
104 Hardware Maintenance Manual: Netfinity 7100 -
First, a source...
Hardware Maintenance Manual - Page 131
...3-3-2(Critical SMBUS error occurred)
1. I /O Legacy Board 3. DIMM 2. Power Supply Backplane 9. 12C Cable
3-3-3(No
1. DIMMs
4. Processor/PCI Board
6. I /O Legacy Board
3-2-1(Serial port failed)
1. Power Supply 8. If problem persists, restart the system 3 times. Battery 4. Note: Restarting the system three times will load default settings.
3. Run Configuration/Setup
Symptom-to...
Hardware Maintenance Manual - Page 132
... and the system 1. Run Configuration/Setup, set the Start Options Power-On Status to determine
if one is defective.) 3. Power Supply (If two are installed, swap them to enable.
2. See "Undetermined problems" on , remove the cover and check the diagnostic panel LEDs.
Run LED diagnostics.
122 Hardware Maintenance Manual: Netfinity 7100 - Processor 2. Keyboard 2. Video adapter (if...
Hardware Maintenance Manual - Page 142
...(if installed) 3. Processor/PCI board
151 (Real time clock error)
1. Battery 3. I /O Legacy board
114 (Adapter read-only memory 1. Run Configuration/Setup 2. Run Configuration/Setup 2. Battery 3. Run Configuration/Setup
changed, see ″Memory Settings″ on password corrupted)
1.
I /O Legacy Board
184 (Power-on page 34.)
2. Processor/PCI Board
176 (Computer...
Hardware Maintenance Manual - Page 146
...PCI Card
1. Type 8666 Processor/PCI Board 3. I /O Legacy Board
1. Failing Adapter 3. Processor/PCI Board
1. I /O Legacy Board
1. I /O Legacy Board
1. Processor/PCI Board 2. I /O Legacy Board 2. Processor/PCI Board 3. Processor
1. Processor 2
136 Hardware Maintenance Manual: Netfinity 7100 - Run Configuration/Setup 2. Run Configuration/Setup 2. Failing Adapter...
IBM 866631Y Reviews
Do you have an experience with the IBM 866631Y that you would like to share?
Earn 750 points for your review!
We have not received any reviews for IBM yet.
Earn 750 points for your review!