Owner's Manual
Page 1
Owner's Manual Model 82023 1 42950-01 09/09/2011 Belle Meade Bath Ventilator with Light English Español Página 21 42950-01 20110909 ©2011 Hunter Fan Co.
Owner's Manual Model 82023 1 42950-01 09/09/2011 Belle Meade Bath Ventilator with Light English Español Página 21 42950-01 20110909 ©2011 Hunter Fan Co.
Owner's Manual
Page 2
... DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service. TO CLEAN FAN ASSEMBLY: Unplug motor cord from a tub or shower. 9. To remove motor plate, find the single tab on product for use for installation in the off the circuit breakers to the outdoors. Gently vacuum fan, motor and interior of the housing or insert a screwdriver into wall(s) or ceiling, do not damage electrical wiring...
... DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service. TO CLEAN FAN ASSEMBLY: Unplug motor cord from a tub or shower. 9. To remove motor plate, find the single tab on product for use for installation in the off the circuit breakers to the outdoors. Gently vacuum fan, motor and interior of the housing or insert a screwdriver into wall(s) or ceiling, do not damage electrical wiring...
Owner's Manual
Page 3
Check all packing materials before installation. 2 J F Turn off the power source. 3 42950-01 09/09/2011 Loosen screws. E 95044-01-096 F 95029-01-000 77481-01-000 G H 03242-01-232 95491-07-000 I x2 J 65222-01-232 K 77521...-000 M 97264-01-000 75184-01-092 N 97266-01-000 O P 76081-01-308 Before Installation 1 Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes NOTE: Remove all the parts. x4 A *B *C 3/8" Cable Connector x2 D Extra Screws * NOTE: Strain relief cable connector must be installed. If damaged, call 1-888-830-1326 for replacements. Not Included.
Check all packing materials before installation. 2 J F Turn off the power source. 3 42950-01 09/09/2011 Loosen screws. E 95044-01-096 F 95029-01-000 77481-01-000 G H 03242-01-232 95491-07-000 I x2 J 65222-01-232 K 77521...-000 M 97264-01-000 75184-01-092 N 97266-01-000 O P 76081-01-308 Before Installation 1 Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes NOTE: Remove all the parts. x4 A *B *C 3/8" Cable Connector x2 D Extra Screws * NOTE: Strain relief cable connector must be installed. If damaged, call 1-888-830-1326 for replacements. Not Included.
Owner's Manual
Page 4
3 4 I F Remove the motor/blower from the housing. 5 Remove packing material. 6 Remove the pre-loaded screw tip covers. 7 H Back out the pre-loaded screw tips until flush with the side of the housing. 8 G Remove the wiring cover screw. 4 42950-01 09/09/2011 Remove the wiring cover.
3 4 I F Remove the motor/blower from the housing. 5 Remove packing material. 6 Remove the pre-loaded screw tip covers. 7 H Back out the pre-loaded screw tips until flush with the side of the housing. 8 G Remove the wiring cover screw. 4 42950-01 09/09/2011 Remove the wiring cover.
Owner's Manual
Page 5
attaching to step C11, page 11 For Existing Construction - Use second if needed. Choose Installation Option For New Construction - attaching to joist go to step B11, page 8 For Existing Construction - Screw pre-loaded screws into the housing and secure with washer. 9 10 F C Pop out the first wiring access slug. B Insert the strain relief (not included) into joist or framing. 5 42950...
attaching to step C11, page 11 For Existing Construction - Use second if needed. Choose Installation Option For New Construction - attaching to joist go to step B11, page 8 For Existing Construction - Screw pre-loaded screws into the housing and secure with washer. 9 10 F C Pop out the first wiring access slug. B Insert the strain relief (not included) into joist or framing. 5 42950...
Owner's Manual
Page 6
A15 A016 F H Install the wiring cover plate. Connect 4" duct and vent to be purchased. 6 42950-01 09/09/2011 Make sure all wiring connections are inside the box or under the wiring cover plate. A14 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. Tape joints. A13 Route wires through the strain relief. If ducting does not fit securely, an adapter may need to the outside.
A15 A016 F H Install the wiring cover plate. Connect 4" duct and vent to be purchased. 6 42950-01 09/09/2011 Make sure all wiring connections are inside the box or under the wiring cover plate. A14 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. Tape joints. A13 Route wires through the strain relief. If ducting does not fit securely, an adapter may need to the outside.
Owner's Manual
Page 7
Make sure the wires are not pinched between the motor and the housing. A19 A20 J Secure the motor by inserting the tabs and pushing up into position. I Reinstall the motor by tightening the 2 screws. A21 ON A22 Go to step E1 OFF on the power source. A17 0 A18 0 Connect wiring harness. If the motor does not run, check the plug connection. 7 42950-01 09/09/2011 Turn on page 17 to attach grille. Test the motor. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS.
Make sure the wires are not pinched between the motor and the housing. A19 A20 J Secure the motor by inserting the tabs and pushing up into position. I Reinstall the motor by tightening the 2 screws. A21 ON A22 Go to step E1 OFF on the power source. A17 0 A18 0 Connect wiring harness. If the motor does not run, check the plug connection. 7 42950-01 09/09/2011 Turn on page 17 to attach grille. Test the motor. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS.
Owner's Manual
Page 8
Drill a hole in the center of screws by using holes as a template. B15 B16 Insert screws, leaving space between joists B11 B12 F E Slide the mounting rails into brackets. 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. B13 B14 F 1/8" bit Mark position of each outline. Screws are not provided. 8 42950-01 09/09/2011 Attach the rails onto the screws. suspended between the screw head and the joist. New Construction -
Drill a hole in the center of screws by using holes as a template. B15 B16 Insert screws, leaving space between joists B11 B12 F E Slide the mounting rails into brackets. 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. B13 B14 F 1/8" bit Mark position of each outline. Screws are not provided. 8 42950-01 09/09/2011 Attach the rails onto the screws. suspended between the screw head and the joist. New Construction -
Owner's Manual
Page 9
Connect 4" duct and vent to be purchased. 9 42950-01 09/09/2011 Make sure all wiring connections are inside the box or under the wiring cover plate. B19 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. B20 B21 G H Install the wiring cover plate. Tape joints. If ducting does not fit securely, an adapter may need to the outside. B17 B18 Tighten screws. Route wires through the strain relief.
Connect 4" duct and vent to be purchased. 9 42950-01 09/09/2011 Make sure all wiring connections are inside the box or under the wiring cover plate. B19 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. B20 B21 G H Install the wiring cover plate. Tape joints. If ducting does not fit securely, an adapter may need to the outside. B17 B18 Tighten screws. Route wires through the strain relief.
Owner's Manual
Page 10
B24 B25 J Secure the motor by inserting the tabs and pushing up into position. Reinstall the motor by tightening the 2 screws. B26 ON B27 Go to step E1 OFF on the power source. Turn on page 17 to attach grille. If the motor does not run, check the plug connection. 10 42950-01 09/09/2011 Test the motor. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. Make sure the wires are not pinched between the motor and the housing. B22 B23 I I Connect wiring harness.
B24 B25 J Secure the motor by inserting the tabs and pushing up into position. Reinstall the motor by tightening the 2 screws. B26 ON B27 Go to step E1 OFF on the power source. Turn on page 17 to attach grille. If the motor does not run, check the plug connection. 10 42950-01 09/09/2011 Test the motor. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. Make sure the wires are not pinched between the motor and the housing. B22 B23 I I Connect wiring harness.
Owner's Manual
Page 11
accessible from above C11 EXISTING FAN NO EXISTING FAN OR Remove an existing fan and check to accommodate the new motor housing (8"x 8 1/2"). Mark position of your sheetrock. C13 Slide the mounting rails into brackets. Existing Construction - C14 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of screws by using holes as a template to mark position. 8" 8 1/2" C12 F E Cut out an opening is large enough to make sure the opening for the housing. Use the motor housing as a template. 11 42950-01 09/09/2011
accessible from above C11 EXISTING FAN NO EXISTING FAN OR Remove an existing fan and check to accommodate the new motor housing (8"x 8 1/2"). Mark position of your sheetrock. C13 Slide the mounting rails into brackets. Existing Construction - C14 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of screws by using holes as a template to mark position. 8" 8 1/2" C12 F E Cut out an opening is large enough to make sure the opening for the housing. Use the motor housing as a template. 11 42950-01 09/09/2011
Owner's Manual
Page 12
Screws are not provided. C17 Insert screws, leaving space between the screw head and the joist. C19 Tighten screws. If ducting does not fit securely, an adapter may need to the outside. Tape joints. C15 C16 Drill a hole in the center of each outline. C18 Attach the rails onto the screws. C20 Connect 4" duct and vent to be purchased. 12 Route wires through the strain relief. 42950-01 09/09/2011
Screws are not provided. C17 Insert screws, leaving space between the screw head and the joist. C19 Tighten screws. If ducting does not fit securely, an adapter may need to the outside. Tape joints. C15 C16 Drill a hole in the center of each outline. C18 Attach the rails onto the screws. C20 Connect 4" duct and vent to be purchased. 12 Route wires through the strain relief. 42950-01 09/09/2011
Owner's Manual
Page 13
C23 C24 G I H Install the wiring cover plate. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. 13 42950-01 09/09/2011 C21 Tighten the strain relief screws. Connect wiring harness. Make sure all wiring connections are inside the box or under the wiring cover plate. C22 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown.
C23 C24 G I H Install the wiring cover plate. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. 13 42950-01 09/09/2011 C21 Tighten the strain relief screws. Connect wiring harness. Make sure all wiring connections are inside the box or under the wiring cover plate. C22 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown.
Owner's Manual
Page 14
C29 Go to step E1 on the power source. Test the motor. If the motor does not run, check the plug connection. 14 42950-01 09/09/2011 C27 C28 ON OFF Turn on page 17 to attach grille. C25 C26 I Reinstall the motor by tightening the 2 screws. J Secure the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing.
C29 Go to step E1 on the power source. Test the motor. If the motor does not run, check the plug connection. 14 42950-01 09/09/2011 C27 C28 ON OFF Turn on page 17 to attach grille. C25 C26 I Reinstall the motor by tightening the 2 screws. J Secure the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing.
Owner's Manual
Page 15
Move the housing into the joist. 15 42950-01 09/09/2011 Existing Construction - ing (8"x 8 1/2"). If ducting does not fit securely, an adapter may need to accommodate the new motor hous- Tape joints. accessible only from below D11 EXISTING FAN D12 F Remove an existing fan and check to make sure the opening is large enough to be purchased. D15 Attach existing ducting to duct connector. F Install the housing flush with the sheetrock and secure by tightening the pre-loaded screws into position above the ceiling D13 D14 2 1 Route wires through strain relief.
Move the housing into the joist. 15 42950-01 09/09/2011 Existing Construction - ing (8"x 8 1/2"). If ducting does not fit securely, an adapter may need to accommodate the new motor hous- Tape joints. accessible only from below D11 EXISTING FAN D12 F Remove an existing fan and check to make sure the opening is large enough to be purchased. D15 Attach existing ducting to duct connector. F Install the housing flush with the sheetrock and secure by tightening the pre-loaded screws into position above the ceiling D13 D14 2 1 Route wires through strain relief.
Owner's Manual
Page 16
... the tabs and pushing up into position. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. D17 D18 G H Install the wiring cover plate. D16 Fan Motor Light 2 Pin Black White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. D20 I Connect wiring harness. Make sure the wires are inside the box or under the wiring cover plate.
... the tabs and pushing up into position. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. D17 D18 G H Install the wiring cover plate. D16 Fan Motor Light 2 Pin Black White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. D20 I Connect wiring harness. Make sure the wires are inside the box or under the wiring cover plate.
Owner's Manual
Page 17
E4 J Remove the strain relief bracket screw. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS. E2 K Connect wiring harness. Position the strain relief bracket under the motor as shown. 17 42950-01 09/09/2011 D21 Turn on the power source. If the motor does not run, check the plug connection. Attaching the Grille E1 F N Remove the thumbscrews. E3 K D22 ON OFF Test the motor.
E4 J Remove the strain relief bracket screw. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS. E2 K Connect wiring harness. Position the strain relief bracket under the motor as shown. 17 42950-01 09/09/2011 D21 Turn on the power source. If the motor does not run, check the plug connection. Attaching the Grille E1 F N Remove the thumbscrews. E3 K D22 ON OFF Test the motor.
Owner's Manual
Page 18
E7 E8 Install bulbs (not included). L Attach thumbscrews. N Screw finial into light fixture). Slide light fixture over posts. E9 M Align glass dome and push up. E5 E6 K Align posts A, B, C and D (stamped into motor housing) with posts A, B, C and D (stamped into position. 18 42950-01 09/09/2011 Complete. WARNING: To reduce the risk of electrical shock, all 4 thumbscrews MUST be properly installed.
E7 E8 Install bulbs (not included). L Attach thumbscrews. N Screw finial into light fixture). Slide light fixture over posts. E9 M Align glass dome and push up. E5 E6 K Align posts A, B, C and D (stamped into motor housing) with posts A, B, C and D (stamped into position. 18 42950-01 09/09/2011 Complete. WARNING: To reduce the risk of electrical shock, all 4 thumbscrews MUST be properly installed.
Owner's Manual
Page 19
... a new bulb. • Turn power on, replace fuse, or reset breaker. • Check all fasteners. • Check the glass to make sure it is secure. • Check the flapper to make sure it matches the wiring diagram. hunterfan.com. 19 42950-01 09/09/2011 Solution: • HUNTER Fan Bath Ventilators are secure. • Check the wiring to make sure it matches the wiring diagram. Trouble Shooting Problem: Fan...
... a new bulb. • Turn power on, replace fuse, or reset breaker. • Check all fasteners. • Check the glass to make sure it is secure. • Check the flapper to make sure it matches the wiring diagram. hunterfan.com. 19 42950-01 09/09/2011 Solution: • HUNTER Fan Bath Ventilators are secure. • Check the wiring to make sure it matches the wiring diagram. Trouble Shooting Problem: Fan...
Owner's Manual
Page 20
... your Hunter bath exhaust fan is required when requesting warranty service. Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within five years after the date of sale to you due to us , mishandling, improper installation, modifications or damage to the Hunter bath exhaust fan...
... your Hunter bath exhaust fan is required when requesting warranty service. Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within five years after the date of sale to you due to us , mishandling, improper installation, modifications or damage to the Hunter bath exhaust fan...