Owner's Manual
Page 1
Set & $ave Programmable Thermostat installation and operation manual English Form# 42711-01 20091118 ©2009 Hunter Fan Co. 1 Model 44260
Set & $ave Programmable Thermostat installation and operation manual English Form# 42711-01 20091118 ©2009 Hunter Fan Co. 1 Model 44260
Owner's Manual
Page 3
Table of Contents Important Information 5 Tools 6 Uninstalling the Existing Unit 7 Installing the Thermostat 12 installing the wall plate 12 connecting the wires 16 attaching the thermostat 18 Settings 22 Methods of Operation 26 manual operation 28 default programs 32 creating custom programs 34 Icons and Features 38 Wiring 49 Troubleshooting 52 3
Table of Contents Important Information 5 Tools 6 Uninstalling the Existing Unit 7 Installing the Thermostat 12 installing the wall plate 12 connecting the wires 16 attaching the thermostat 18 Settings 22 Methods of Operation 26 manual operation 28 default programs 32 creating custom programs 34 Icons and Features 38 Wiring 49 Troubleshooting 52 3
Owner's Manual
Page 4
Your new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for choosing a Hunter programmable thermostat. Set & Save Programmable Thermostat Model 44260 Congratulations! Thank you for complete operation instructions. 4
Your new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for choosing a Hunter programmable thermostat. Set & Save Programmable Thermostat Model 44260 Congratulations! Thank you for complete operation instructions. 4
Owner's Manual
Page 6
Tools This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your new thermostat, you will need the following supplies: Flat-head screwdriver Small Phillips-head screwdriver Hammer Electric drill and 3/16" bit Two 1.5 Volt (AA) size alkaline batteries 6
Tools This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your new thermostat, you will need the following supplies: Flat-head screwdriver Small Phillips-head screwdriver Hammer Electric drill and 3/16" bit Two 1.5 Volt (AA) size alkaline batteries 6
Owner's Manual
Page 13
Position the new wall plate on the Hunter wall plate, or if there are no existing holes, visually level the wall plate and mark the wall for two holes. 13 If the existing holes do not match those on the wall and pull the labeled wires through the opening. 3. installing the thermostat INSTALLING THE WALL PLATE 1. Remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2.
Position the new wall plate on the Hunter wall plate, or if there are no existing holes, visually level the wall plate and mark the wall for two holes. 13 If the existing holes do not match those on the wall and pull the labeled wires through the opening. 3. installing the thermostat INSTALLING THE WALL PLATE 1. Remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2.
Owner's Manual
Page 15
Tap the plastic anchors into the anchors. Verify that the wall plate is visually level and securely tighten both screws. 15 Insert the mounting screws through the opening. Remove the wall plate and drill two 3/16" holes where marked. 5. installing the thermostat, cont. 4. Reposition the wall plate on the wall, pulling the wires through the wall plate and into the holes until they are flush with the wall. 6.
Tap the plastic anchors into the anchors. Verify that the wall plate is visually level and securely tighten both screws. 15 Insert the mounting screws through the opening. Remove the wall plate and drill two 3/16" holes where marked. 5. installing the thermostat, cont. 4. Reposition the wall plate on the wall, pulling the wires through the wall plate and into the holes until they are flush with the wall. 6.
Owner's Manual
Page 17
... should be wrapped in 2. If you have both an RH and RC wire. If you do not remove, the terminal screws. Jumper G RC RH Y W place. installing the thermostat, cont.
... should be wrapped in 2. If you have both an RH and RC wire. If you do not remove, the terminal screws. Jumper G RC RH Y W place. installing the thermostat, cont.
Owner's Manual
Page 19
... the ENABLE position. Locate the System Type switch on the back of the thermostat. Select either STD (Standard) or HP (Heat Pump) to cooling mode.) 2. installing the thermostat, cont. System type -
... the ENABLE position. Locate the System Type switch on the back of the thermostat. Select either STD (Standard) or HP (Heat Pump) to cooling mode.) 2. installing the thermostat, cont. System type -
Owner's Manual
Page 21
Restore power at the electrical panel or furnace. 21 Press the thermostat onto the wall plate and press to snap the bottom tab into place properly, the unit may be damaged. Note: Do not force the thermostat onto the wall plate, as the terminal pins may not work. 5. Insert two AA alkaline batteries. 6. If the thermostat does not snap into place. Place the top of the thermostat over the two tabs on the wall plate. installing the thermostat, cont. 4.
Restore power at the electrical panel or furnace. 21 Press the thermostat onto the wall plate and press to snap the bottom tab into place properly, the unit may be damaged. Note: Do not force the thermostat onto the wall plate, as the terminal pins may not work. 5. Insert two AA alkaline batteries. 6. If the thermostat does not snap into place. Place the top of the thermostat over the two tabs on the wall plate. installing the thermostat, cont. 4.
Owner's Manual
Page 41
... span setting. (Up will decrease your system is RESET, the span cycle will revert to adjust the system ON/OFF cycle rate. When batteries are installed, or the unit is cycling too fast or too slowly. allows you to 2. 41 Press and hold both the Up and Down buttons until the...
... span setting. (Up will decrease your system is RESET, the span cycle will revert to adjust the system ON/OFF cycle rate. When batteries are installed, or the unit is cycling too fast or too slowly. allows you to 2. 41 Press and hold both the Up and Down buttons until the...
Owner's Manual
Page 43
... power shortage mode. After removing the batteries, program and time settings will be erased. The system will turn off until new AA alkaline batteries are installed. If all battery power is left, the battery icon will flash alone on the display and your system will remain off . When the batteries are... detected as weak, the icon will resume normal operation after new batteries are installed. The thermostat will flash until new batteries are installed. 43 Low battery warning - ICONS AND FEATURES, cont. 4.
... power shortage mode. After removing the batteries, program and time settings will be erased. The system will turn off until new AA alkaline batteries are installed. If all battery power is left, the battery icon will flash alone on the display and your system will remain off . When the batteries are... detected as weak, the icon will resume normal operation after new batteries are installed. The thermostat will flash until new batteries are installed. 43 Low battery warning - ICONS AND FEATURES, cont. 4.
Owner's Manual
Page 53
... as much as a 4-minute delay before the system turns on or off . 5 a. Replace the batteries. 5 e. Wait. If applicable, make sure the furnace blower door is installed between the RC and RH terminals. 6. Replace batteries. 53 The display will come on or off to the system. 5 d. Check the circuit breakers and switches...
... as much as a 4-minute delay before the system turns on or off . 5 a. Replace the batteries. 5 e. Wait. If applicable, make sure the furnace blower door is installed between the RC and RH terminals. 6. Replace batteries. 53 The display will come on or off to the system. 5 d. Check the circuit breakers and switches...