ADEMCO LYNXR-I Security Systems Installation and Setup Guide ARMED READY OFF 12 3 ESCAPE AWAY RECORD VOLUME PLAY 45 6 ADD LIGHTS ON TEST BYPASS STAY 78 9 DELETE LIGHTS OFF CODE CHIME AUX 0# SELECT STATUS NO DELAY FUNCTION K14114 3/06 Rev. B
ADEMCO LYNXR-I Security Systems Installation and Setup Guide ARMED READY OFF 12 3 ESCAPE AWAY RECORD VOLUME PLAY 45 6 ADD LIGHTS ON TEST BYPASS STAY 78 9 DELETE LIGHTS OFF CODE CHIME AUX 0# SELECT STATUS NO DELAY FUNCTION K14114 3/06 Rev. B
Setup Guide
Page 4
... Stay Arming • Remote Phone Control • "Follow Me" Reminder and System Announcements SYSTEM POWER • Primary Power: Ademco K10145X10 Plug-in Transformer, 110VAC to 9VAC, 25VA output (K10145CN in EEROM • Can be uploaded, downloaded or controlled via...• Long Range Radio/Audio alarm verification SPECIAL FEATURES • Two-way voice communication • Speaker phone operation - 4 - COMMUNICATION • Ademco Low Speed • Sescoa/Radionics • Ademco Express • Ademco Contact ID • Paging feature • Internet Central Station Communication ...
... Stay Arming • Remote Phone Control • "Follow Me" Reminder and System Announcements SYSTEM POWER • Primary Power: Ademco K10145X10 Plug-in Transformer, 110VAC to 9VAC, 25VA output (K10145CN in EEROM • Can be uploaded, downloaded or controlled via...• Long Range Radio/Audio alarm verification SPECIAL FEATURES • Two-way voice communication • Speaker phone operation - 4 - COMMUNICATION • Ademco Low Speed • Sescoa/Radionics • Ademco Express • Ademco Contact ID • Paging feature • Internet Central Station Communication ...
Setup Guide
Page 7
... (+). 4. e. If disabled, however, no sounding will occur upon AC loss, since the external sounder does not operate when AC power is electrically connected and secured. ADEMCO WAVE2EX). OR a bell to RJ31X terminals 4 (red) and OR 5 (green). Remove the shorting jumper (shunt) on the terminal board. Make Powerline Carrier Device Connections - If using...
... (+). 4. e. If disabled, however, no sounding will occur upon AC loss, since the external sounder does not operate when AC power is electrically connected and secured. ADEMCO WAVE2EX). OR a bell to RJ31X terminals 4 (red) and OR 5 (green). Remove the shorting jumper (shunt) on the terminal board. Make Powerline Carrier Device Connections - If using...
Setup Guide
Page 10
... module supervision in the LYNXR-I. The 7845i-ENT/7845i and 7845CV2 can take place. - 10 - Program the device as shown below: 4-WIRE CABLE (N4632-4) BATTERY ADEMCO K4362 YEL RED BLK GRN DATA OUT NC +12 VDC GND DATA IN LRR/IP COMMUNICATIONS PORT LYNXR-I . 2. Connect the 4-wire communications cable to the...
... module supervision in the LYNXR-I. The 7845i-ENT/7845i and 7845CV2 can take place. - 10 - Program the device as shown below: 4-WIRE CABLE (N4632-4) BATTERY ADEMCO K4362 YEL RED BLK GRN DATA OUT NC +12 VDC GND DATA IN LRR/IP COMMUNICATIONS PORT LYNXR-I . 2. Connect the 4-wire communications cable to the...
Setup Guide
Page 11
...BATTERY PACK SHOWN 2. Install battery retainer. The "LOW BAT" message should clear within four hours or by a 9VAC, 25VA Plug-in Transformer, ADEMCO K10145X10 (K10145CN in the wiring diagram. BATTERY RECEPTACLE Ensure the cover is powered by entering Test Mode. LYNXR-I Installation and Setup Guide AC Power ...and Backup Battery The system is snapped closed prior to applying AC power. Use only the provided ADEMCO K10145X10 or K10145CN Transformer. The voltage reading between terminals 15 and 16 of an AC power loss, the system is supported by a long...
...BATTERY PACK SHOWN 2. Install battery retainer. The "LOW BAT" message should clear within four hours or by a 9VAC, 25VA Plug-in Transformer, ADEMCO K10145X10 (K10145CN in the wiring diagram. BATTERY RECEPTACLE Ensure the cover is powered by entering Test Mode. LYNXR-I Installation and Setup Guide AC Power ...and Backup Battery The system is snapped closed prior to applying AC power. Use only the provided ADEMCO K10145X10 or K10145CN Transformer. The voltage reading between terminals 15 and 16 of an AC power loss, the system is supported by a long...
Setup Guide
Page 22
... if a 3-digit account number (for AVM. - 22 - If ten-digit format is used to enter the correct type of phone dialing (pulse or tone), and to schedule a time driven message. Enter 0 as the 4th digit of ✻43 through ✻44, if 3+1 dialer reporting is to activate...10043;44✻. Do not fill unused spaces. The telephone message can be entered in Fields ✻43 or ✻44. (3) Option 5 or 7 (ADEMCO Contact ID® Reporting) must be used. (For an explanation of these formats, see the System Communication section of this manual.) Notes: (1) The maximum ...
... if a 3-digit account number (for AVM. - 22 - If ten-digit format is used to enter the correct type of phone dialing (pulse or tone), and to schedule a time driven message. Enter 0 as the 4th digit of ✻43 through ✻44, if 3+1 dialer reporting is to activate...10043;44✻. Do not fill unused spaces. The telephone message can be entered in Fields ✻43 or ✻44. (3) Option 5 or 7 (ADEMCO Contact ID® Reporting) must be used. (For an explanation of these formats, see the System Communication section of this manual.) Notes: (1) The maximum ...
Setup Guide
Page 24
.../restore report is still open , an "exit alarm" message will be sent. If the control detects an RF Jam condition, a "FAULT" message appears for F. With ADEMCO Contact ID® Reporting: Enter a digit in automatic advance to report. The actual report code digits that report. Entering "0" in the second box results in...
.../restore report is still open , an "exit alarm" message will be sent. If the control detects an RF Jam condition, a "FAULT" message appears for F. With ADEMCO Contact ID® Reporting: Enter a digit in automatic advance to report. The actual report code digits that report. Entering "0" in the second box results in...
Setup Guide
Page 48
... communication with 4 position DIP switch] internal style), a HAYES brand Optima 336 external, a HAYES brand Optima 24 Plus FAX96, or an Ademco CIA Modem. • Compass Downloader for Windows (at times of the call back number. Site-Initiated Remote Programming: The installer or subscriber ... office. 4. Station-Initiated Remote Programming: The operator calls the site from an IBM-compatible Personal Computer (PC), a HAYES Modem, and ADEMCO's Compass Downloader for security so that it is at the control panel). 5. Data Encryption: Data passed between the Control and downloader. 2....
... communication with 4 position DIP switch] internal style), a HAYES brand Optima 336 external, a HAYES brand Optima 24 Plus FAX96, or an Ademco CIA Modem. • Compass Downloader for Windows (at times of the call back number. Site-Initiated Remote Programming: The installer or subscriber ... office. 4. Station-Initiated Remote Programming: The operator calls the site from an IBM-compatible Personal Computer (PC), a HAYES Modem, and ADEMCO's Compass Downloader for security so that it is at the control panel). 5. Data Encryption: Data passed between the Control and downloader. 2....
Setup Guide
Page 57
... hears the handshake it waits to hear a "handshake" frequency from the receiver acknowledging that can be given by the panel, the panel will display "FC." ADEMCO Contact ID® Reporting Format Comprises a 4-digit subscriber number, 1-digit event qualifier ("new" or "restore"), 3-digit event code, and 3-digit zone number, user number, or...
... hears the handshake it waits to hear a "handshake" frequency from the receiver acknowledging that can be given by the panel, the panel will display "FC." ADEMCO Contact ID® Reporting Format Comprises a 4-digit subscriber number, 1-digit event qualifier ("new" or "restore"), 3-digit event code, and 3-digit zone number, user number, or...
Setup Guide
Page 58
... AZ SSSS Tt SSSS Bb SSSS EAC SSSS LLB SSSS OU SSSS CU SSSS Gg SSSS RZ SSSSRA Ac SSSS RLLB SSSS RTt SSSS RBb ADEMCO Contact ID® Reporting takes the following format: CCCC Q EEE GG ZZZ where: CCCC = Customer (subscriber) ID Q = Event qualifier, where: E = new event, and R = ... Log 80% Full System Inactivity Notes: (1) The following codes are logged in the ZZZ location. LRR/IP Communications Module trouble restore report is sent after two code + off (only if physically restored) - 58 - System status messages (AC Loss, Walk Test, etc.) contain zeroes in the event log upon occurrence, ...
... AZ SSSS Tt SSSS Bb SSSS EAC SSSS LLB SSSS OU SSSS CU SSSS Gg SSSS RZ SSSSRA Ac SSSS RLLB SSSS RTt SSSS RBb ADEMCO Contact ID® Reporting takes the following format: CCCC Q EEE GG ZZZ where: CCCC = Customer (subscriber) ID Q = Event qualifier, where: E = new event, and R = ... Log 80% Full System Inactivity Notes: (1) The following codes are logged in the ZZZ location. LRR/IP Communications Module trouble restore report is sent after two code + off (only if physically restored) - 58 - System status messages (AC Loss, Walk Test, etc.) contain zeroes in the event log upon occurrence, ...
Setup Guide
Page 65
...13, 38 5817 13 5827 13, 15, 20 -AAC Loss Report Code 24, 62 AC Power 11, 12 AC Restore Report Code 62 ADEMCO Express 22, 70 ADEMCO Low Speed 22, 70 Alarm Bell Timeout 20, 62 Alarm Output 4 Alarm Restore Codes 62 Alarm Restore Report Code 25 Alarm Sounder 70 ... Assign Zone Voice Descriptors 41, 62 Audible Exit Warning/Quick Exit 21, 62 Audio Alarm Verification (AAV)/Remote Phone Control ........ 27 Audio Alarm Verification (Two-Way Voice Feature 53 AUX Function 52 AUX Function/1-Button Paging 27, 62 AUX Key 27 Away Mode 51 -BBabysitter Code 50 Back Plate 5 Backlighting...
...13, 38 5817 13 5827 13, 15, 20 -AAC Loss Report Code 24, 62 AC Power 11, 12 AC Restore Report Code 62 ADEMCO Express 22, 70 ADEMCO Low Speed 22, 70 Alarm Bell Timeout 20, 62 Alarm Output 4 Alarm Restore Codes 62 Alarm Restore Report Code 25 Alarm Sounder 70 ... Assign Zone Voice Descriptors 41, 62 Audible Exit Warning/Quick Exit 21, 62 Audio Alarm Verification (AAV)/Remote Phone Control ........ 27 Audio Alarm Verification (Two-Way Voice Feature 53 AUX Function 52 AUX Function/1-Button Paging 27, 62 AUX Key 27 Away Mode 51 -BBabysitter Code 50 Back Plate 5 Backlighting...
Setup Guide
Page 70
... 1-516-921-6704 / ext. 1667 World Wide Web Address http:// www.honeywell.com/security - 70 - Communication: FORMATS SUPPORTED: ADEMCO Express, 10 characters/sec, DTMF (TouchTone) Data Tones, 1400/2300Hz ACK, 1400Hz KISSOFF. Electrical: VOLTAGE INPUT: 9VAC from plug-in...Radionics/SESCOA, 20 pulses/sec, 1800Hz Data Tone, 2300Hz ACK/KISSOFF. You may contact Technical Support via Toll Free Fax. Having this information handy will receive a reply within 24 hours. ALARM SOUNDER: Piezo = 6-14VDC, 30mA max/ Bell = 6-14VDC, 120mA max (e.g., ADEMCO's WAVE2EX). 3. Physical: 10-3/8" W x 7-1/8"...
... 1-516-921-6704 / ext. 1667 World Wide Web Address http:// www.honeywell.com/security - 70 - Communication: FORMATS SUPPORTED: ADEMCO Express, 10 characters/sec, DTMF (TouchTone) Data Tones, 1400/2300Hz ACK, 1400Hz KISSOFF. Electrical: VOLTAGE INPUT: 9VAC from plug-in...Radionics/SESCOA, 20 pulses/sec, 1800Hz Data Tone, 2300Hz ACK/KISSOFF. You may contact Technical Support via Toll Free Fax. Having this information handy will receive a reply within 24 hours. ALARM SOUNDER: Piezo = 6-14VDC, 30mA max/ Bell = 6-14VDC, 120mA max (e.g., ADEMCO's WAVE2EX). 3. Physical: 10-3/8" W x 7-1/8"...
Setup Guide
Page 72
...verbal, of the obligations of this Limited Warranty is the only warranty made by Seller on the product or, for products not having an Ademco date stamp, for 12 months from date of a burglary, robbery, fire or other events occurring without providing an alarm, but it ... risk of original purchase unless the installation instructions or catalog sets forth a shorter period, in all cases provide adequate warning or protection. www.honeywell.com/security acting through its Security & Custom Electronics business ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its own plans and...
...verbal, of the obligations of this Limited Warranty is the only warranty made by Seller on the product or, for products not having an Ademco date stamp, for 12 months from date of a burglary, robbery, fire or other events occurring without providing an alarm, but it ... risk of original purchase unless the installation instructions or catalog sets forth a shorter period, in all cases provide adequate warning or protection. www.honeywell.com/security acting through its Security & Custom Electronics business ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its own plans and...