Owner's Manual
Page 14
Advanced Installation System setup 13 Wiring 21 Troubleshooting 24 Customer assistance 26 Limited warranty 27
Advanced Installation System setup 13 Wiring 21 Troubleshooting 24 Customer assistance 26 Limited warranty 27
Owner's Manual
Page 15
SETUP WIRING ASybsotuetmyosuertunpew thermostat Step 1 Press System & Fan. RTH7600 0120 20 System & Fan Schedule Clock & More M27522 Step 2 Press and hold the center key until the screen changes (approximately 5 seconds). 0120 20 System Fan Done M27523 ASSISTANCE TROUBLESHOOTING 13 69-2206EF-01
SETUP WIRING ASybsotuetmyosuertunpew thermostat Step 1 Press System & Fan. RTH7600 0120 20 System & Fan Schedule Clock & More M27522 Step 2 Press and hold the center key until the screen changes (approximately 5 seconds). 0120 20 System Fan Done M27523 ASSISTANCE TROUBLESHOOTING 13 69-2206EF-01
Owner's Manual
Page 16
Press DONE to previous selections made. NOTE: Some functions in the following pages may not appear due to save & exit. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 14 Function Setting 0120 20 Go Back Next Done M27524 Press NEXT to advance to next function. Press s t to change Function Settings. SETUP WIRING Advanced Installation Guide ACbhoauntgiynogursentetwingthsermostat See pages 15-20 to change setting.
Press DONE to previous selections made. NOTE: Some functions in the following pages may not appear due to save & exit. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 14 Function Setting 0120 20 Go Back Next Done M27524 Press NEXT to advance to next function. Press s t to change Function Settings. SETUP WIRING Advanced Installation Guide ACbhoauntgiynogursentetwingthsermostat See pages 15-20 to change setting.
Owner's Manual
Page 17
See page 14 to page 16. December) 0150 Date Setting Press s/t to change the current date: 01 - 31 ASSISTANCE TROUBLESHOOTING 15 69-2206EF-01 Function Settings & Options 0120 Year Setting (first two digits) Press s/t to change the first two digits of the year: 20 = ... last two digits of the year: 01 - 99 (i.e., 2001 - 2099) 0140 Month Setting Press s/t to change the current month: 01 - 12 (i.e., January - SETUP WIRING RTH7600 ASybsotuetmyosuertunpew thermostat NOTE: If you set the time and date as shown on page 10, press NEXT to function 0170 and go to navigate between...
See page 14 to page 16. December) 0150 Date Setting Press s/t to change the current date: 01 - 31 ASSISTANCE TROUBLESHOOTING 15 69-2206EF-01 Function Settings & Options 0120 Year Setting (first two digits) Press s/t to change the first two digits of the year: 20 = ... last two digits of the year: 01 - 99 (i.e., 2001 - 2099) 0140 Month Setting Press s/t to change the current month: 01 - 12 (i.e., January - SETUP WIRING RTH7600 ASybsotuetmyosuertunpew thermostat NOTE: If you set the time and date as shown on page 10, press NEXT to function 0170 and go to navigate between...
Owner's Manual
Page 18
...), 1 cooling stage (wire on Y). 10 Heat/Cool Multiple stages: 1 heat stage (wire on Y and Y2). out central air conditioning. 6 Cool only: Central air condi- ASSISTANCE TROUBLESHOOTING 69-2206EF-01 16 Function Settings & Options 0170 Select System Press s/t to navigate between functions. tioning. 2 Heat pump: Heat pump with central air condi- tioning...
...), 1 cooling stage (wire on Y). 10 Heat/Cool Multiple stages: 1 heat stage (wire on Y and Y2). out central air conditioning. 6 Cool only: Central air condi- ASSISTANCE TROUBLESHOOTING 69-2206EF-01 16 Function Settings & Options 0170 Select System Press s/t to navigate between functions. tioning. 2 Heat pump: Heat pump with central air condi- tioning...
Owner's Manual
Page 19
SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to the O/B terminal (see page 23). Function Settings & Options 0180 Heating Fan Control Press s/t to select your heating system & fan control: 0 Gas ... connected a wire labeled "O" to the O/B terminal (see page 22). 1 Heating changeover valve: Use this setting if you connected a wire labeled "B" to navigate between functions. ASSISTANCE TROUBLESHOOTING 17 69-2206EF-01
SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to the O/B terminal (see page 23). Function Settings & Options 0180 Heating Fan Control Press s/t to select your heating system & fan control: 0 Gas ... connected a wire labeled "O" to the O/B terminal (see page 22). 1 Heating changeover valve: Use this setting if you connected a wire labeled "B" to navigate between functions. ASSISTANCE TROUBLESHOOTING 17 69-2206EF-01
Owner's Manual
Page 20
... high-efficiency furnace: Hot water system or gas furnace (more than 90% efficiency). 1 Gas/oil steam or gravity system: Steam or gravity heat systems. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 18 Function Settings & Options 0240 Heating Cycle Press s/t to select your heating system: 9 Electric furnace: Electric heating systems. 5 Gas or oil furnace...
... high-efficiency furnace: Hot water system or gas furnace (more than 90% efficiency). 1 Gas/oil steam or gravity system: Steam or gravity heat systems. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 18 Function Settings & Options 0240 Heating Cycle Press s/t to select your heating system: 9 Electric furnace: Electric heating systems. 5 Gas or oil furnace...
Owner's Manual
Page 21
ASSISTANCE TROUBLESHOOTING 19 69-2206EF-01 SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to daylight saving time (2007 and beyond, for areas that do not use the new 2007 DST calendar). 2 On: Auto-change to ...
ASSISTANCE TROUBLESHOOTING 19 69-2206EF-01 SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to daylight saving time (2007 and beyond, for areas that do not use the new 2007 DST calendar). 2 On: Auto-change to ...
Owner's Manual
Page 22
SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to save and exit setup. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 20 Function Settings & Options 0500 Furnace Filter Press s/t to set the desired Change reminder interval: Reminder 0 Off (no reminder) 1 Reminder after 10-...
SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to save and exit setup. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 20 Function Settings & Options 0500 Furnace Filter Press s/t to set the desired Change reminder interval: Reminder 0 Off (no reminder) 1 Reminder after 10-...
Owner's Manual
Page 23
... must connect both R and RH wires, remove metal jumper. Connect the R wire to the Rc terminal, and the RH wire to the C terminal. WIRING ASSISTANCE TROUBLESHOOTING RC Rc 2 R R 2 W W Y Y G G C C 3 Y2 Y2 W2 W2 M28076 21 69-2206EF-01 If your old thermostat had only 1 C or C1 wire, connect it to the R terminal...
... must connect both R and RH wires, remove metal jumper. Connect the R wire to the Rc terminal, and the RH wire to the C terminal. WIRING ASSISTANCE TROUBLESHOOTING RC Rc 2 R R 2 W W Y Y G G C C 3 Y2 Y2 W2 W2 M28076 21 69-2206EF-01 If your old thermostat had only 1 C or C1 wire, connect it to the R terminal...
Owner's Manual
Page 24
... match letters on new thermostat. 2. SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES HEAT PUMP WIRE HOLE HEAT PUMP C Aux Aux OYG G E Y L O/B RC R R M28104 ASSISTANCE TROUBLESHOOTING 69-2206EF-01 22 Match each other. 4. Use a screwdriver to each labeled wire with same letter on thermostat, see page 23. Push any excess wire...
... match letters on new thermostat. 2. SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES HEAT PUMP WIRE HOLE HEAT PUMP C Aux Aux OYG G E Y L O/B RC R R M28104 ASSISTANCE TROUBLESHOOTING 69-2206EF-01 22 Match each other. 4. Use a screwdriver to each labeled wire with same letter on thermostat, see page 23. Push any excess wire...
Owner's Manual
Page 25
... pumps only) Leave metal jumper in place, connecting R & Rc terminals. If another wire is no C wire). If E and Aux terminals do not each other. 2 3 ASSISTANCE TROUBLESHOOTING 35 5 6 46 M28077 23 69-2206EF-01 SETUP WIRING Wiring-heat pump RTH7600 Alternate wiring (for help .
... pumps only) Leave metal jumper in place, connecting R & Rc terminals. If another wire is no C wire). If E and Aux terminals do not each other. 2 3 ASSISTANCE TROUBLESHOOTING 35 5 6 46 M28077 23 69-2206EF-01 SETUP WIRING Wiring-heat pump RTH7600 Alternate wiring (for help .
Owner's Manual
Page 26
... light is on when Control to make sure it is set to match heat is set to match your heating equipment (see page 17). ASSISTANCE TROUBLESHOOTING 69-2206EF-01 24 Fan does not Check Function 0180: Heating Fan turn on If thermostat is in Emergency Heat mode the red light is..., please try the following suggestions. It shows that the thermostat is normal. Most problems can be corrected quickly and easily. SETUP WIRING Advanced Installation Guide Troubleshooting If you have difficulty with your heating and cooling equipment (see page 16).
... light is on when Control to make sure it is set to match heat is set to match your heating equipment (see page 17). ASSISTANCE TROUBLESHOOTING 69-2206EF-01 24 Fan does not Check Function 0180: Heating Fan turn on If thermostat is in Emergency Heat mode the red light is..., please try the following suggestions. It shows that the thermostat is normal. Most problems can be corrected quickly and easily. SETUP WIRING Advanced Installation Guide Troubleshooting If you have difficulty with your heating and cooling equipment (see page 16).
Owner's Manual
Page 27
... for the system to restart safely, without damage to respond. Press SYSTEM to set lower than the Inside temperature. mode ASSISTANCE TROUBLESHOOTING 25 69-2206EF-01 Press SYSTEM to set higher not respond than the Inside temperature. Check circuit breaker and reset if necessary... sure power switch at heating & cooling system is on the screen Compressor protection feature is set system to Heat. SETUP WIRING Troubleshooting RTH7600 Heating or cool- Make sure the temperature is closed securely. Wait 5 minutes for the system to the compressor. Make sure ...
... for the system to restart safely, without damage to respond. Press SYSTEM to set lower than the Inside temperature. mode ASSISTANCE TROUBLESHOOTING 25 69-2206EF-01 Press SYSTEM to set higher not respond than the Inside temperature. Check circuit breaker and reset if necessary... sure power switch at heating & cooling system is on the screen Compressor protection feature is set system to Heat. SETUP WIRING Troubleshooting RTH7600 Heating or cool- Make sure the temperature is closed securely. Wait 5 minutes for the system to the compressor. Make sure ...
Owner's Manual
Page 28
Advanced Installation Guide Customer assistance For assistance with this product, please visit http://DIYthermostats.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. SETUP WIRING ASSISTANCE TROUBLESHOOTING 69-2206EF-01 26
Advanced Installation Guide Customer assistance For assistance with this product, please visit http://DIYthermostats.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. SETUP WIRING ASSISTANCE TROUBLESHOOTING 69-2206EF-01 26