Failure to properly follow all instructions and precautions can be found on owning a Honeywell inverter generator! You may be asked to be sure to this generator. Ambient Temp.: Serial Number: HW2000i 101440A 120V/12V 2.0kW 40oC Phase: 1 Frequency: 60Hz Engine RPM: 5000 Fuel....com © 2009 Northshore Power Systems, LLC The Honeywell Trademark is used under license from Honeywell International Inc. For your safety, and the safety of Purchase: Store/Dealer Purchased From: Generator Model Number: Generator Serial Number: Northshore Power Systems, LLC 4425 N. Please...
Failure to properly follow all instructions and precautions can be found on owning a Honeywell inverter generator! You may be asked to be sure to this generator. Ambient Temp.: Serial Number: HW2000i 101440A 120V/12V 2.0kW 40oC Phase: 1 Frequency: 60Hz Engine RPM: 5000 Fuel....com © 2009 Northshore Power Systems, LLC The Honeywell Trademark is used under license from Honeywell International Inc. For your safety, and the safety of Purchase: Store/Dealer Purchased From: Generator Model Number: Generator Serial Number: Northshore Power Systems, LLC 4425 N. Please...
Owners Manual
Page 3
...FOR PROFESSION: FEATURES INFLUENCING PRODUCT PURCHASE: BRAND REPUTATION EASE OF USE PORTABILITY SIZE / WEIGHT POWER RATING STYLE/APPEARANCE PRICE WARRANTY WHAT OTHER TYPE OF POWER EQUIPMENT ARE YOU INTERESTED IN PURCHASING IN THE FUTURE? IN-STORE ...RADIO/TV INTERNET STORE CIRCULAR PRINT WORD OF MOUTH PERSONAL INFORMATION FIRST NAME STREET ADDRESS LAST NAME CITY, STATE, ZIP PHONE COUNTRY EMAIL CHECK HERE TO RECEIVE ANNUAL MAINTENANCE REMINDERS AND SPECIAL OFFERS FROM HONEYWELL GENERATORS...
...FOR PROFESSION: FEATURES INFLUENCING PRODUCT PURCHASE: BRAND REPUTATION EASE OF USE PORTABILITY SIZE / WEIGHT POWER RATING STYLE/APPEARANCE PRICE WARRANTY WHAT OTHER TYPE OF POWER EQUIPMENT ARE YOU INTERESTED IN PURCHASING IN THE FUTURE? IN-STORE ...RADIO/TV INTERNET STORE CIRCULAR PRINT WORD OF MOUTH PERSONAL INFORMATION FIRST NAME STREET ADDRESS LAST NAME CITY, STATE, ZIP PHONE COUNTRY EMAIL CHECK HERE TO RECEIVE ANNUAL MAINTENANCE REMINDERS AND SPECIAL OFFERS FROM HONEYWELL GENERATORS...
Owners Manual
Page 4
... OTHER NONE HOUSEHOLD INTERESTS: HOME IMPROVEMENT AUTOMOTIVE WORK CAMPING OTHER THANK YOU FOR REGISTERING YOUR PRODUCT. PLEASE RETURN THIS FORM TO THE FOLLOWING ADDRESS: Northshore Power Systems, LLC 4425 N Port Washington Road Suite 105 Milwaukee, WI 53212-1082 PLEASE MAIL THIS FORM IN A SEALED ENVELOPE. 3 - CHECK HERE IF YOU DO NOT...
... OTHER NONE HOUSEHOLD INTERESTS: HOME IMPROVEMENT AUTOMOTIVE WORK CAMPING OTHER THANK YOU FOR REGISTERING YOUR PRODUCT. PLEASE RETURN THIS FORM TO THE FOLLOWING ADDRESS: Northshore Power Systems, LLC 4425 N Port Washington Road Suite 105 Milwaukee, WI 53212-1082 PLEASE MAIL THIS FORM IN A SEALED ENVELOPE. 3 - CHECK HERE IF YOU DO NOT...
Owners Manual
Page 5
... ...22 Air Filter Maintenance ...23 Cleaning Spark Arrestor Screen ...24 Spark Plug Service ...25 Transporting Generator ...26 Storing Generator ...26 TROUBLESHOOTING ...27 SPECIFICATIONS AND WIRING DIAGRAMS 29 WARRANTIES ...33 NORTHSHORE POWER SYSTEMS CONSUMER LIMITED WARRANTY 33 NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY 34 INDEX ...37 MAINTENANCE PARTS 39 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com i
... ...22 Air Filter Maintenance ...23 Cleaning Spark Arrestor Screen ...24 Spark Plug Service ...25 Transporting Generator ...26 Storing Generator ...26 TROUBLESHOOTING ...27 SPECIFICATIONS AND WIRING DIAGRAMS 29 WARRANTIES ...33 NORTHSHORE POWER SYSTEMS CONSUMER LIMITED WARRANTY 33 NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY 34 INDEX ...37 MAINTENANCE PARTS 39 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com i
Owners Manual
Page 8
... properly and securely. • Be careful not to generator caused by misuse or modification is set on wet surface. • Keep the generator out of reach of vapor. Safety Messages Safety Messages Electric Shock Hazards WARNING Generators produce powerful voltage that are extremely flammable and explosive under Warranty. 2 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
... properly and securely. • Be careful not to generator caused by misuse or modification is set on wet surface. • Keep the generator out of reach of vapor. Safety Messages Safety Messages Electric Shock Hazards WARNING Generators produce powerful voltage that are extremely flammable and explosive under Warranty. 2 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
Owners Manual
Page 11
...: Power Output: Max. Record Generator Information Write down the identification information specific to your generator ready for any damage that all safety and operation instructions provided in the product manual. Ambient Temp.: Serial Number: HW2000i 101440A 120V/12V 2.0kW 40oC Phase: 1 Frequency: 60Hz Engine RPM: 5000 Fuel: Gasoline Insulation Class: F FIGURE 3: Generator Nameplate Location HW1000i / HW2000i Inverter Generator...
...: Power Output: Max. Record Generator Information Write down the identification information specific to your generator ready for any damage that all safety and operation instructions provided in the product manual. Ambient Temp.: Serial Number: HW2000i 101440A 120V/12V 2.0kW 40oC Phase: 1 Frequency: 60Hz Engine RPM: 5000 Fuel: Gasoline Insulation Class: F FIGURE 3: Generator Nameplate Location HW1000i / HW2000i Inverter Generator...
Owners Manual
Page 12
... required to be registered with local utility companies. • If generator is used at a construction site, there may electrocute utility company workers or others who contact utility lines during a power outage. Electrical current can be observed. 6 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual A transfer switch is either a manual switch, an automatic switch, or...
... required to be registered with local utility companies. • If generator is used at a construction site, there may electrocute utility company workers or others who contact utility lines during a power outage. Electrical current can be observed. 6 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual A transfer switch is either a manual switch, an automatic switch, or...
Owners Manual
Page 14
... Set Tripped Illuminates red when the generator is overloaded or if there is unregulated. The engine will automatically stop to ground wire for battery charging. DC outlet ranges from a Honeywell dealer. 2. If there is pulled...generator is running (or while recoil is no power at outlets, see AC "Troubleshooting" on page 27. 4. This outlet should not be grounded to prevent electrical shock from generator to generator for the overload. 5. Ground Terminal Connects generator to prevent generator damage. 8 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator...
... Set Tripped Illuminates red when the generator is overloaded or if there is unregulated. The engine will automatically stop to ground wire for battery charging. DC outlet ranges from a Honeywell dealer. 2. If there is pulled...generator is running (or while recoil is no power at outlets, see AC "Troubleshooting" on page 27. 4. This outlet should not be grounded to prevent electrical shock from generator to generator for the overload. 5. Ground Terminal Connects generator to prevent generator damage. 8 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator...
Owners Manual
Page 20
... stop the engine automatically before the crankcase oil gets below the safety line. HW1000i / HW2000i Inverter Generator Owner's Manual Turn off and unplug all equipment to the ON position. AC Operation AC Operation AC Operation NOTE: DC power and AC power can be improved by installing a smaller diameter main fuel jet in the appliance and...
... stop the engine automatically before the crankcase oil gets below the safety line. HW1000i / HW2000i Inverter Generator Owner's Manual Turn off and unplug all equipment to the ON position. AC Operation AC Operation AC Operation NOTE: DC power and AC power can be improved by installing a smaller diameter main fuel jet in the appliance and...
Owners Manual
Page 21
...Single/Double) Fan, Ceiling* Fan, Window* Furnace* Hair Dryer Heater, Portable Typical Running Watts 3500 500-1440 50-1210 10 900-1200 120 / 30 or less 150 / 30 or less 50 785 1200-2400 (using generator. Disconnect the appliance and determine whether the problem is overloaded. See Table... energy consumption) 1800-5000 60 / 100 65-175 55-250 750* 1200-1875 750-1500 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 15 ance you will need to power life support devices or life support appliances. • Never use only UL-listed, three-prong extension cords....
...Single/Double) Fan, Ceiling* Fan, Window* Furnace* Hair Dryer Heater, Portable Typical Running Watts 3500 500-1440 50-1210 10 900-1200 120 / 30 or less 150 / 30 or less 50 785 1200-2400 (using generator. Disconnect the appliance and determine whether the problem is overloaded. See Table... energy consumption) 1800-5000 60 / 100 65-175 55-250 750* 1200-1875 750-1500 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 15 ance you will need to power life support devices or life support appliances. • Never use only UL-listed, three-prong extension cords....
Owners Manual
Page 22
...require a higher wattage output than the inverter generator will produce. CAUTION Do not run power cords under carpet, rugs, or other materials where heat might build up to three times normal running watts for starting this appliance. Examples of the generator. Appliance Wattage Information Appliance Wattage Information ...furnace blowers. Typical Appliance Running Wattages *Allow up or cord damage may go unnoticed. 16 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual Be sure the appliance power rating does not exceed that have motors requires more...
...require a higher wattage output than the inverter generator will produce. CAUTION Do not run power cords under carpet, rugs, or other materials where heat might build up to three times normal running watts for starting this appliance. Examples of the generator. Appliance Wattage Information Appliance Wattage Information ...furnace blowers. Typical Appliance Running Wattages *Allow up or cord damage may go unnoticed. 16 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual Be sure the appliance power rating does not exceed that have motors requires more...
Owners Manual
Page 33
... to reset circuit breaker. Add fuel (page 22). Pump fuel in the carburetor. (HW2000i model only) Clean or replace air filter (page 23). Replace circuit breaker. Replace defective cord set . HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 27 No power at receptacles PROBABLE CAUSE Engine switch or fuel valve off. Drain fuel tank...
... to reset circuit breaker. Add fuel (page 22). Pump fuel in the carburetor. (HW2000i model only) Clean or replace air filter (page 23). Replace circuit breaker. Replace defective cord set . HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 27 No power at receptacles PROBABLE CAUSE Engine switch or fuel valve off. Drain fuel tank...
Owners Manual
Page 35
... 2000 100 60 120 12-18 104q / 40q 14q / -10q 5000** OHV 4-cycle 125 1.5 / 5.7 0.48 / 450 0.024-0.028 / 0.6-0.7 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 29 SPECIFICATIONS AND WIRING DIAGRAMS Model HW1000i DIMENSIONS Length [in / mm] 18.1 / 459.7 Height [in / mm] 15.1 / 383....5 Width [in / mm] 9.6 / 243.8 Dry Weight [lb / kg] 30 / 13.6 POWER OUTPUT Rated (AC) [watts] 900 Rated (DC) [watts] 60 Frequency* [hertz] 60 Voltage (AC)* [volts] 120 Voltage (DC)* [volts] 12-18 OPERATING TEMPERATURE...
... 2000 100 60 120 12-18 104q / 40q 14q / -10q 5000** OHV 4-cycle 125 1.5 / 5.7 0.48 / 450 0.024-0.028 / 0.6-0.7 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 29 SPECIFICATIONS AND WIRING DIAGRAMS Model HW1000i DIMENSIONS Length [in / mm] 18.1 / 459.7 Height [in / mm] 15.1 / 383....5 Width [in / mm] 9.6 / 243.8 Dry Weight [lb / kg] 30 / 13.6 POWER OUTPUT Rated (AC) [watts] 900 Rated (DC) [watts] 60 Frequency* [hertz] 60 Voltage (AC)* [volts] 120 Voltage (DC)* [volts] 12-18 OPERATING TEMPERATURE...
Owners Manual
Page 39
...known to an authorized Honeywell Generator Dealer. GENERATOR SERVICE Do not return your original receipt from date of merchantability or fitness for service. WARRANTIES NORTHSHORE POWER SYSTEMS CONSUMER LIMITED WARRANTY Honeywell Inverter Generator Effective November 1, 2008 LIMITED WARRANTY Northshore Power Systems, LLC, ...limited to this product intended to : Northshore Power Systems, LLC Attention: Product Warranty and Service Dept. 4425 N Port Washington Road Suite 105 Milwaukee WI 53212-1082 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 33 This ...
...known to an authorized Honeywell Generator Dealer. GENERATOR SERVICE Do not return your original receipt from date of merchantability or fitness for service. WARRANTIES NORTHSHORE POWER SYSTEMS CONSUMER LIMITED WARRANTY Honeywell Inverter Generator Effective November 1, 2008 LIMITED WARRANTY Northshore Power Systems, LLC, ...limited to this product intended to : Northshore Power Systems, LLC Attention: Product Warranty and Service Dept. 4425 N Port Washington Road Suite 105 Milwaukee WI 53212-1082 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 33 This ...
Owners Manual
Page 40
...or improper maintenance of your inverter generator to you retain all scheduled maintenance. NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY Honeywell Inverter Generator WARRANTY STATEMENT The U.S. ...B. Purge valves 8. Claims. Warranty claims shall be performed at an authorized NSP Honeywell generator dealer. 34 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual Length of the Emission Control Warranty. NSP warrants to the original ...
...or improper maintenance of your inverter generator to you retain all scheduled maintenance. NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY Honeywell Inverter Generator WARRANTY STATEMENT The U.S. ...B. Purge valves 8. Claims. Warranty claims shall be performed at an authorized NSP Honeywell generator dealer. 34 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual Length of the Emission Control Warranty. NSP warrants to the original ...
Owners Manual
Page 41
...-1082 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 35 NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY 5. QUESTIONS If you have questions regarding your emissions warranty rights and responsibilities, you should contact the Warranty and Service department at NSP. Any replacement part that is equivalent in the Honeywell Generator Owner's Manual...
...-1082 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 35 NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY 5. QUESTIONS If you have questions regarding your emissions warranty rights and responsibilities, you should contact the Warranty and Service department at NSP. Any replacement part that is equivalent in the Honeywell Generator Owner's Manual...
Owners Manual
Page 46
Northshore Power Systems, LLC 4425 N. makes no representation or warranties with respect to this product Honeywell International Inc. Port Washington Rd., Suite 105 Milwaukee, WI 53212-1082 USA TEL 1-888-494-3571 www.honeywellgenerators.com P/N: 101435B January 2009 c 2009 Northshore Power Systems, LLC The Honeywell Trademark is used under license from Honeywell International Inc.
Northshore Power Systems, LLC 4425 N. makes no representation or warranties with respect to this product Honeywell International Inc. Port Washington Rd., Suite 105 Milwaukee, WI 53212-1082 USA TEL 1-888-494-3571 www.honeywellgenerators.com P/N: 101435B January 2009 c 2009 Northshore Power Systems, LLC The Honeywell Trademark is used under license from Honeywell International Inc.