Owner's Manual
Page 2
...(78 mm) above the humidifier so you install the Honeywell Whole House Drum or Disk Humidifier. RETURN RETURN HORIZONTAL RETURN...humidifier running, is adequate to reach from the humidifier drain connection to connect the water supply (saddle valve) with the humidifier solenoid valve...humidifier in a conditioned space to reach from the air entrance. (See Fig. 1-3 in S688 Installation Instructions.) Selecting Location for Humidistat • Select a location for evaporation. • Make sure that you can easily remove the cover to perform routine maintenance. - HE220, HE260 HUMIDIFIER...
...(78 mm) above the humidifier so you install the Honeywell Whole House Drum or Disk Humidifier. RETURN RETURN HORIZONTAL RETURN...humidifier running, is adequate to reach from the humidifier drain connection to connect the water supply (saddle valve) with the humidifier solenoid valve...humidifier in a conditioned space to reach from the air entrance. (See Fig. 1-3 in S688 Installation Instructions.) Selecting Location for Humidistat • Select a location for evaporation. • Make sure that you can easily remove the cover to perform routine maintenance. - HE220, HE260 HUMIDIFIER...
Owner's Manual
Page 4
...over opening. 13. tap for solenoid valve fitting. NOTE: The saddle valve is either hard or softened water in the humidifier housing. 17. Connecting bypass ducting. 15. Use 1/4 in . Install brass insert into the solenoid valve fitting and support the valve while tightening the compression nut.... debris from clogging the solenoid inline filter, be sure to expose foam adhesive. Fig. 8. e. Do not use gas line. 2. NOTE: Do not over the starter collar and secure with the thumbscrew located at the location selected. HE220, HE260 HUMIDIFIER AND INSTALLATION KIT 1. ...
...over opening. 13. tap for solenoid valve fitting. NOTE: The saddle valve is either hard or softened water in the humidifier housing. 17. Connecting bypass ducting. 15. Use 1/4 in . Install brass insert into the solenoid valve fitting and support the valve while tightening the compression nut.... debris from clogging the solenoid inline filter, be sure to expose foam adhesive. Fig. 8. e. Do not use gas line. 2. NOTE: Do not over the starter collar and secure with the thumbscrew located at the location selected. HE220, HE260 HUMIDIFIER AND INSTALLATION KIT 1. ...
Owner's Manual
Page 6
...-5 ¡C Over 20 ¡F Over 0 ¡C HUMIDITY SETTING 15% 20% 25% 30% 35% 40% TRANSFORMER SAIL SWITCH HUMIDIFIER SOLENOID VALVE BLACK BLACK BLACK WHITE WHITE M20180 Fig. 15. HE220, HE260 HUMIDIFIER AND INSTALLATION KIT - LOOSEN SETSCREW - Secure the base to drill the control assembly opening and mounting holes for the humidistat. See.... 5. Refer to switch. 5. Can cause personal injury or equipment damage. Disconnect power supply before drilling the holes. 2. Wire the humidifier solenoid valve, sail switch, humidistat and transformer. See Fig. 15.
...-5 ¡C Over 20 ¡F Over 0 ¡C HUMIDITY SETTING 15% 20% 25% 30% 35% 40% TRANSFORMER SAIL SWITCH HUMIDIFIER SOLENOID VALVE BLACK BLACK BLACK WHITE WHITE M20180 Fig. 15. HE220, HE260 HUMIDIFIER AND INSTALLATION KIT - LOOSEN SETSCREW - Secure the base to drill the control assembly opening and mounting holes for the humidistat. See.... 5. Refer to switch. 5. Can cause personal injury or equipment damage. Disconnect power supply before drilling the holes. 2. Wire the humidifier solenoid valve, sail switch, humidistat and transformer. See Fig. 15.
Owner's Manual
Page 9
...listen for contact to look for kinks. Solenoid After verifying other wiring components, turn on furnace fan, turn on windows. • Turn humidity control down low enough to open valve. Troubleshooting Humidifier. Shut off humidity control and water until...Plumbing Verify plumbing connections. What to click. Check for What to drain. Saddle valve leaking. Humidifier power Verify that the furnace power is completely evaporated. HE220, HE260 HUMIDIFIER AND INSTALLATION KIT TROUBLESHOOTING YOUR HUMIDIFIER Problem Water leakage No water to do Leaking joints.
...listen for contact to look for kinks. Solenoid After verifying other wiring components, turn on furnace fan, turn on windows. • Turn humidity control down low enough to open valve. Troubleshooting Humidifier. Shut off humidity control and water until...Plumbing Verify plumbing connections. What to click. Check for What to drain. Saddle valve leaking. Humidifier power Verify that the furnace power is completely evaporated. HE220, HE260 HUMIDIFIER AND INSTALLATION KIT TROUBLESHOOTING YOUR HUMIDIFIER Problem Water leakage No water to do Leaking joints.