Reference Manual - Page 11
Tables
OEM MANUAL:K6602771
Table 2-1 Commands Supported 28 Table 2-2 Commands Not Supported 30 Table 3-1 Summary of Fibre Channel Topology 32 Table 3-2 Specification of R_CTL/TYPE field 37 Table...47 Table 3-9 Ordered Sets 49 Table 3-10 SOF Delimiters 49 Table 3-11 EOF Delimiters 50 Table 3-12 Primitive Signals 50 Table 3-13 Primitive Sequences 51 Table 3-14 Link Service Frames 52 Table ...
Reference Manual - Page 62
... PLOGI
Bit
7
6
5
4
3
2
1
0
Byte
0
Link Service Command Code
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
0
0
2
0
0
0
0
0
0
0
0
3
0
0
0
0
0
0
0
0
4-19
Common Service Parameters
20-27
N_Port Name
28-35
Node Name
36-51
Class 1 Service Parameters(Not supported)
52-67
Class 2 Service Parameters(Not supported)
68-83
Class 3 Service Parameters
84-99
Reserved...
Reference Manual - Page 68
... FLOGI
Bit
7
6
5
4
3
2
1
0
Byte
0
Link Service Command Code
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
0
0
2
0
0
0
0
0
0
0
0
3
0
0
0
0
0
0
0
0
4-19
Common Service Parameters
20-27
N_Port Name
28-35
Node Name
36-51
Class 1 Service Parameters(Not supported)
52-67
Class 2 Service Parameters(Not supported)
68-83
Class 3 Service Parameters
84-99
Reserved...
Reference Manual - Page 78
OEM MANUAL:K6602771
Table 3-43 ACC payload for PRLI
Bit
7
6
5
4
3
2
1
0
Byte
0
Link Service Command Code
0
0
0
0
0
0
1
0
1
Page Length
0
0
0
1
0
0
0
0
2
Payload Length
0
0
0
0
0
0
0
0
3
0
0
0
1
0
1
0
0
4
Type Code or common Service parameters
0
0
0
0
1
0
0
0
5
Type Code extension
0
0
0
0
0
0
0
0
6
Originator Responder ...
Reference Manual - Page 91
... the ACA condition) with a CHECK CONDITION status. CLEAR ACA (Plan to support) The CLEAR ACA is used to clear the ACA condition.
Read Data Set One when the command specified by the CDB field will return Check condition status. OEM MANUAL:K6602771
Logical Unit Number Zero is the only valid LUN for the...
Reference Manual - Page 119
The Standard Inquiry Data is set to 0. Table 6-8 Standard Inquiry Data
Bit Byte
0
7
6
5
Peripheral Qualifier
4... (in ASCII)
"HITACHI€"
Product Identification (in ASCII)
32-35
Product Revision Level (in Table 6-10 (Supported Vital Product Data) and...is not considered as an error. The controller terminates the ...the requested inquiry data. OEM MANUAL:K6602771 No data is transferred...
Reference Manual - Page 121
... port device. OEM MANUAL:K6602771
The ISO Version (International Standard Organization Version) field is loaded with code 0H and indicates that the controller does not conform with the ANSI SCSI-2 specifications.
The WBus 32 (Wide Bus 32) bit is set to 0 and indicates that the controller does not support the Enclosure Services Diagnostic pages.The EncServ...
Reference Manual - Page 135
OEM MANUAL:K6602771 --
The value of DS bit is a "don't care" for the list ...code set to disable the saving operation.
LOG SENSE usage -- : A zero value of the drive-defined log parameters saving. On the other pages (01H-06H) is a "don't care" for a cumulative log parameter means the updating of TSD bit indicates the initiator requests the drive to the disk after it is not supported...
Reference Manual - Page 137
... counter is set to prevent further updating of the log parameter, data counter or list parameter. If the command completes correctly (except the data counter being at its own drive-defined maximum value. An LP bit of the control mode page is a list parameter. When the maximum parameter code value supported by the drive, determined by...
Reference Manual - Page 221
...be set to the application client. If the allocation length specified by the PERSISTENT RESERVE IN command is shown in response to an error or...any truncation resulting from an insufficient allocation length. OEM MANUAL:K6602771
The GENERATION field shall contain a 32-bit... RESERVE or RELEASE service action, or by a PERSISTENT RESERVE OUT command that shall be sent to zero as part of bytes in ...
Reference Manual - Page 222
...part of the APTPL bit value the generation value shall be a reservation descriptor for each element, if any, having a persistent reservation.
This shall not be incremented by a PERSISTENT RESERVE IN command, by a PERSISTENT RESERVE OUT command that performs a RESERVE or RELEASE service.... There shall be set to follow in reservation descriptor(s).
OEM MANUAL:K6602771
Table 6-73 ...
Reference Manual - Page 229
... controller supports only LU_SCOPE, when value other cases, the APTPL bit shall be ignored.
If the service action is REGISTER, REGISTER AND IGNORE EXISTING KEY, or CLEAR or if the scope is the source of the persistent reservations that is a LU_SCOPE reservation, the scope-specific address field shall be set to be registered. OEM MANUAL...
Reference Manual - Page 230
...which fields are set by the application ... in the target shall release the persistent reservation for each service action and scope value. OEM MANUAL:K6602771 If the last valid APTPL bit value received by the... ELEMENT_SCOPE
type
Ignored Ignored
Parameters
Service
Reservation action
key
reservation
key
Valid
Valid
Ignored Valid
Scope-specific address
Ignored Ignored
Valid Valid
...
Reference Manual - Page 266
... Sense Key. For the Receive Diagnostic Results command, the controller sets the Page Length to 0.
SEND DIAGNOSTIC:(1Dh) 6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19 Page: 266 / 313 OEM MANUAL:K6602771
Table 6-92 Supported Diagnostic Page (Code = 00H)
Bit 7
6
5
4
3
2
1
0
Byte
0
Page Code
0
0
0
0
0
0
0
0
1
Reserved
0
0
0
0
0
0
0
0
2
Page Length (MSB...
Reference Manual - Page 271
... Service Process is SFF-8045 support at bit 7 of Byte 1 at this time, "1" is set, and "0" is set as Byte 1 of Enclosure Status page (4Bytes), and a controller reports them to each Elements. SEND DIAGNOSTIC:(1Dh) 6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19 Page: 271 / 313 Table 6-102 Enclosure Element Description page
Bit 7
6
5
4
3
2
1
0
Byte
0
Page Code...