Safety and Regulatory Information, Fourth Edition - HP 9000 rp4410 and HP 9000 rp4440
Page 3
...) Japan Power Cord Notice Korea RFI Statement Canada RFI Statement Australia C-Tick Label Taiwan BSMI Taiwan Battery Warning Germany Acoustics Declaration of HP servers. HP 9000 rp4410 and HP 9000 rp4440 System Safety and Regulatory Information Overview 1 HP 9000 rp4410 and HP 9000 rp4440 System Safety and Regulatory Information Overview Regulatory Compliance statements are required by users in...
...) Japan Power Cord Notice Korea RFI Statement Canada RFI Statement Australia C-Tick Label Taiwan BSMI Taiwan Battery Warning Germany Acoustics Declaration of HP servers. HP 9000 rp4410 and HP 9000 rp4440 System Safety and Regulatory Information Overview 1 HP 9000 rp4410 and HP 9000 rp4440 System Safety and Regulatory Information Overview Regulatory Compliance statements are required by users in...
Safety and Regulatory Information, Fourth Edition - HP 9000 rp4410 and HP 9000 rp4440
Page 5
HP 9000 rp4410 and HP 9000 rp4440 System Safety and Regulatory Information Overview Electrical Safety Locate the AC outlet near the server! There is a danger of used batteries according to the manufacturer's instructions and local disposal requirements. Chapter 1 5 The AC power cords/cables ...and must be provided with a proper AC protective earth (PE) ground connection. An ESD kit (HP P/N A3024-80004) is installed incorrectly. Dispose of explosion if battery is available (or supplied with the same or equivalent type recommended by the manufacturer. Electrostatic Discharge (ESD...
HP 9000 rp4410 and HP 9000 rp4440 System Safety and Regulatory Information Overview Electrical Safety Locate the AC outlet near the server! There is a danger of used batteries according to the manufacturer's instructions and local disposal requirements. Chapter 1 5 The AC power cords/cables ...and must be provided with a proper AC protective earth (PE) ground connection. An ESD kit (HP P/N A3024-80004) is installed incorrectly. Dispose of explosion if battery is available (or supplied with the same or equivalent type recommended by the manufacturer. Electrostatic Discharge (ESD...
Safety and Regulatory Information, Fourth Edition - HP 9000 rp4410 and HP 9000 rp4440
Page 7
...with your household waste disposal service or the shop where you purchased the product. This product may include a real-time clock battery or coin cell battery that may contain perchlorate and may require special handling when recycled or disposed of in a manner that it over to a designated... obtained at the time of disposal will help to conserve natural resources and ensure that protects human health and the environment. HP 9000 rp4410 and HP 9000 rp4440 System Safety and Regulatory Information Overview Disposal of waste equipment by users in private household in which case the user...
...with your household waste disposal service or the shop where you purchased the product. This product may include a real-time clock battery or coin cell battery that may contain perchlorate and may require special handling when recycled or disposed of in a manner that it over to a designated... obtained at the time of disposal will help to conserve natural resources and ensure that protects human health and the environment. HP 9000 rp4410 and HP 9000 rp4440 System Safety and Regulatory Information Overview Disposal of waste equipment by users in private household in which case the user...
Safety and Regulatory Information, Fourth Edition - HP 9000 rp4410 and HP 9000 rp4440
Page 9
...Users: This is a Class A IT (Information Technology) Product. Figure 1-1 Taiwan Battery Warning Germany Acoustics Acoustic noise: • Sound Pressure: LpAm Taiwan Battery Warning The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act are ...required to indicate the recovery marks on the batteries used in a domestic environment, radio frequency disturbance may be required to CNS 13438 (CISPR 22: 1993) Class A. HP 9000 rp4410 and HP 9000 rp4440 System Safety and Regulatory Information Overview Taiwan BSMI ...
...Users: This is a Class A IT (Information Technology) Product. Figure 1-1 Taiwan Battery Warning Germany Acoustics Acoustic noise: • Sound Pressure: LpAm Taiwan Battery Warning The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act are ...required to indicate the recovery marks on the batteries used in a domestic environment, radio frequency disturbance may be required to CNS 13438 (CISPR 22: 1993) Class A. HP 9000 rp4410 and HP 9000 rp4440 System Safety and Regulatory Information Overview Taiwan BSMI ...
Installation Guide, Sixth Edition - HP 9000 rp4410/rp4440
Page 3
... Additional Controls and Indicators 27 Front Bezel 28 Front and Top Covers 29 Hot-Swappable Chassis Fan Units 32 I/O Baseboard Assembly 34 System Battery 38 Installing Power Supplies and Disk Drives 40 Installing Processors 43 Installing Memory 51 Hot-Pluggable PCI/PCI-X 57 Converting SCSI From Simplex to... Duplex 66 Installing the Server Into a Rack, Non-HP rack, or Pedestal 72 HP Rack 72 Non-HP Rack 72 Pedestal Mount 72 Connecting the Cables 73 AC Input Power 73 Core I/O Connections 73 Applying Standby Power to ...
... Additional Controls and Indicators 27 Front Bezel 28 Front and Top Covers 29 Hot-Swappable Chassis Fan Units 32 I/O Baseboard Assembly 34 System Battery 38 Installing Power Supplies and Disk Drives 40 Installing Processors 43 Installing Memory 51 Hot-Pluggable PCI/PCI-X 57 Converting SCSI From Simplex to... Duplex 66 Installing the Server Into a Rack, Non-HP rack, or Pedestal 72 HP Rack 72 Non-HP Rack 72 Pedestal Mount 72 Connecting the Cables 73 AC Input Power 73 Core I/O Connections 73 Applying Standby Power to ...
Installation Guide, Sixth Edition - HP 9000 rp4410/rp4440
Page 7
HP 9000 rp4410 and rp4440 Servers with Bezel 24 Figure 1-7. Accessing T-25 Screws 22 Figure 1-5. Pedestal-Mounted Server 23 Figure 1-6. Accessing the Control Panel 24 Figure 1-8. Hot-Swappable I /O Baseboard Locking Lever 36 Figure 1-17. System Battery Location on Server Rear 74 Figure 1-41. Volume Filler ... Replacing the Top Cover 31 Figure 1-14. Slot ID Numbering 58 Figure 1-33. Ports on I /O Baseboard Assembly Removal 37 Figure 1-18. HP 9000 rp4410 and rp4440 Servers (Rear View 15 Figure 1-4. DVD or CD-RW/DVD LED Indicators 28 Figure 1-11. I /O Fans (Units 0 and...
HP 9000 rp4410 and rp4440 Servers with Bezel 24 Figure 1-7. Accessing T-25 Screws 22 Figure 1-5. Pedestal-Mounted Server 23 Figure 1-6. Accessing the Control Panel 24 Figure 1-8. Hot-Swappable I /O Baseboard Locking Lever 36 Figure 1-17. System Battery Location on Server Rear 74 Figure 1-41. Volume Filler ... Replacing the Top Cover 31 Figure 1-14. Slot ID Numbering 58 Figure 1-33. Ports on I /O Baseboard Assembly Removal 37 Figure 1-18. HP 9000 rp4410 and rp4440 Servers (Rear View 15 Figure 1-4. DVD or CD-RW/DVD LED Indicators 28 Figure 1-11. I /O Fans (Units 0 and...
Installation Guide, Sixth Edition - HP 9000 rp4410/rp4440
Page 38
... 30.) Step 3. Remove the I /O baseboard. 38 Chapter 1 Replace with the identical or equivalent battery. These values must be reset after replacing a battery. Battery Notice This product contains a Lithium battery (HP part number 1420-0386). Follow the manufacturer's recommendations. Locate the system battery on the I /O baseboard assembly from the chassis. (See "Removing the Top Cover" on page...
... 30.) Step 3. Remove the I /O baseboard. 38 Chapter 1 Replace with the identical or equivalent battery. These values must be reset after replacing a battery. Battery Notice This product contains a Lithium battery (HP part number 1420-0386). Follow the manufacturer's recommendations. Locate the system battery on the I /O baseboard assembly from the chassis. (See "Removing the Top Cover" on page...
Installation Guide, Sixth Edition - HP 9000 rp4410/rp4440
Page 39
...the Top Cover" on the back of the battery is installed with the plus (+) sign. Replace the I/O baseboard assembly. (See "Replacing the I /O Baseboard Battery Step 5. The battery is designated by the plus (+) sign facing up the battery holder retaining clip with a flat-head screwdriver... and push on page 31.) Chapter 1 39 Step 6. Lift up the battery holder retaining clip with a flat-head screwdriver...
...the Top Cover" on the back of the battery is installed with the plus (+) sign. Replace the I/O baseboard assembly. (See "Replacing the I /O Baseboard Battery Step 5. The battery is designated by the plus (+) sign facing up the battery holder retaining clip with a flat-head screwdriver... and push on page 31.) Chapter 1 39 Step 6. Lift up the battery holder retaining clip with a flat-head screwdriver...
Installation Guide, Sixth Edition - HP 9000 rp4410/rp4440
Page 40
...cord receptacle and attached to install a hot-swappable power supply. Step 10. c. Verify that you installed the system battery correctly once you installed the system battery correctly. See "Hot-Pluggable PCI/PCI-X" on page 75). Each hot-swappable power supply requires a separate power ...cord, installed in place. 40 Chapter 1 Power Supply Load Order The supported configuration of an HP 9000 rp4410 or rp4440 server requires a minimum of the HP 9000 rp4410 ...
...cord receptacle and attached to install a hot-swappable power supply. Step 10. c. Verify that you installed the system battery correctly once you installed the system battery correctly. See "Hot-Pluggable PCI/PCI-X" on page 75). Each hot-swappable power supply requires a separate power ...cord, installed in place. 40 Chapter 1 Power Supply Load Order The supported configuration of an HP 9000 rp4410 or rp4440 server requires a minimum of the HP 9000 rp4410 ...
Installation Guide, Sixth Edition - HP 9000 rp4410/rp4440
Page 101
... ac input power, 73 ARP Ping, 79 attention button (doorbell), 57, 64 LED, 57, 64, 65 B backplane SCSI accessing, 67 battery system, remove and replace, 38 booting HP-UX LVM maintenance mode, 90 single-user mode, 89 using boot console handler (BCH), 89 C cables, to connect power and LAN, 73...the LAN, 74 console accessing host with GUI, 85 accessing host with TUI, 84 determining connection method, 78 problems, troubleshooting, 94 setup, 75 contacting HP, 99 controls CD/DVD controls, 27 disk drive controls, 27 front panel controls and indicators, 24 core I/O connections, 73 external, 16 internal, ...
... ac input power, 73 ARP Ping, 79 attention button (doorbell), 57, 64 LED, 57, 64, 65 B backplane SCSI accessing, 67 battery system, remove and replace, 38 booting HP-UX LVM maintenance mode, 90 single-user mode, 89 using boot console handler (BCH), 89 C cables, to connect power and LAN, 73...the LAN, 74 console accessing host with GUI, 85 accessing host with TUI, 84 determining connection method, 78 problems, troubleshooting, 94 setup, 75 contacting HP, 99 controls CD/DVD controls, 27 disk drive controls, 27 front panel controls and indicators, 24 core I/O connections, 73 external, 16 internal, ...
Installation Guide, Sixth Edition - HP 9000 rp4410/rp4440
Page 102
... MP See iLO MP N network connectivity, 74 NMI button, 26 O operating system booting and shutting down HP-UX, 89 booting HP-UX in LVM maintenance mode, 90 booting HP-UX in single-user mode, 89 booting to HP-UX, 89 booting using BCH, 89 supported, 89 verifying server configuration, 90 will boot or will... damaged equipment, 21 S safety information, 18 SCSI simplex to duplex, 66 security access settings, 84 risk with DHCP enabled, 84 set up, 84 shut down HP-UX, 90 site preparation, verifying, 20 standby power, 74 static IP address assigning with ARP Ping, 79 assigning with LC command, 81 system...
... MP See iLO MP N network connectivity, 74 NMI button, 26 O operating system booting and shutting down HP-UX, 89 booting HP-UX in LVM maintenance mode, 90 booting HP-UX in single-user mode, 89 booting to HP-UX, 89 booting using BCH, 89 supported, 89 verifying server configuration, 90 will boot or will... damaged equipment, 21 S safety information, 18 SCSI simplex to duplex, 66 security access settings, 84 risk with DHCP enabled, 84 set up, 84 shut down HP-UX, 90 site preparation, verifying, 20 standby power, 74 static IP address assigning with ARP Ping, 79 assigning with LC command, 81 system...
User Service Guide, Fifth Edition - HP 9000 rp4410/4440
Page 5
... Unit 68 Replacing a Hot-Swappable Fan Unit 69 I/O Baseboard Assembly...69 Removing the I/O Baseboard Assembly 69 Replacing the I/O Baseboard Assembly 71 System Battery...72 Battery Notice...72 Replacing the System Battery...72 Installing Power Supplies and Disk Drives 74 Installing Hot-Swappable Power Supplies 74 Power Supply Load Order...74 Installing Hot-Pluggable... Duplex 97 Safety Information...97 Accessing the SCSI Backplane...97 Converting to Duplex...97 Replacing the Removed Modules 101 Installing the Server Into a Rack, Non-HP Rack, or Pedestal 102 Table of Contents 5
... Unit 68 Replacing a Hot-Swappable Fan Unit 69 I/O Baseboard Assembly...69 Removing the I/O Baseboard Assembly 69 Replacing the I/O Baseboard Assembly 71 System Battery...72 Battery Notice...72 Replacing the System Battery...72 Installing Power Supplies and Disk Drives 74 Installing Hot-Swappable Power Supplies 74 Power Supply Load Order...74 Installing Hot-Pluggable... Duplex 97 Safety Information...97 Accessing the SCSI Backplane...97 Converting to Duplex...97 Replacing the Removed Modules 101 Installing the Server Into a Rack, Non-HP Rack, or Pedestal 102 Table of Contents 5
User Service Guide, Fifth Edition - HP 9000 rp4410/4440
Page 8
... I/O Baseboard Assembly...175 Removing the I/O Baseboard Assembly 175 Replacing the I/O Baseboard Assembly 177 Removing and Replacing the I/O Baseboard Locking Lever 180 System Battery...180 Battery Notice...180 Replacing the System Battery...181 Removing and Replacing PCI/PCI-X Cards 182 PCI/PCI-X Configurations...182 PCI/PCI-X Card Path Logging 184 OLA...185 OLR...189...
... I/O Baseboard Assembly...175 Removing the I/O Baseboard Assembly 175 Replacing the I/O Baseboard Assembly 177 Removing and Replacing the I/O Baseboard Locking Lever 180 System Battery...180 Battery Notice...180 Replacing the System Battery...181 Removing and Replacing PCI/PCI-X Cards 182 PCI/PCI-X Configurations...182 PCI/PCI-X Card Path Logging 184 OLA...185 OLR...189...
User Service Guide, Fifth Edition - HP 9000 rp4410/4440
Page 11
.../O Baseboard LEDs, Buttons, and Sensors 39 2-1 Airflow Through HP 9000 rp4410 and rp4440 Servers 48 3-1 HP 9000 rp4410 and rp4440 Servers (Top View 51 3-2 HP 9000 rp4410 and rp4440 Servers with Bezel Removed (Front View 52 3-3 HP 9000 rp4410 and rp4440 Servers (Rear View 52 3-4 Accessing T-25 Screws...Hot-Swappable Power Supply Fan (Unit 2 68 3-16 I/O Baseboard Locking Lever...70 3-17 I/O Baseboard Assembly Removal 71 3-18 System Battery Location on the Extender Board 83 3-28 16-DIMM Memory Extender Board Minimum Configuration 85 3-29 32-DIMM Memory Extender Board Minimum Configuration...
.../O Baseboard LEDs, Buttons, and Sensors 39 2-1 Airflow Through HP 9000 rp4410 and rp4440 Servers 48 3-1 HP 9000 rp4410 and rp4440 Servers (Top View 51 3-2 HP 9000 rp4410 and rp4440 Servers with Bezel Removed (Front View 52 3-3 HP 9000 rp4410 and rp4440 Servers (Rear View 52 3-4 Accessing T-25 Screws...Hot-Swappable Power Supply Fan (Unit 2 68 3-16 I/O Baseboard Locking Lever...70 3-17 I/O Baseboard Assembly Removal 71 3-18 System Battery Location on the Extender Board 83 3-28 16-DIMM Memory Extender Board Minimum Configuration 85 3-29 32-DIMM Memory Extender Board Minimum Configuration...
User Service Guide, Fifth Edition - HP 9000 rp4410/4440
Page 12
... Removal and Replacement 174 6-21 I/O Baseboard Locking Lever...176 6-22 I/O Baseboard Removal...177 6-23 S5102 Dipswitch Setting...178 6-24 Accessing the S5102 Dipswitch 178 6-25 Battery Location on the I/O Baseboard 181 6-26 Slot ID Numbering...183 6-27 PCI/PCI-X OLX Divider Layout 186 6-28 PCI-X Card Latch Opening Sequence 186 6-29...
... Removal and Replacement 174 6-21 I/O Baseboard Locking Lever...176 6-22 I/O Baseboard Removal...177 6-23 S5102 Dipswitch Setting...178 6-24 Accessing the S5102 Dipswitch 178 6-25 Battery Location on the I/O Baseboard 181 6-26 Slot ID Numbering...183 6-27 PCI/PCI-X OLX Divider Layout 186 6-28 PCI-X Card Latch Opening Sequence 186 6-29...
User Service Guide, Fifth Edition - HP 9000 rp4410/4440
Page 72
... rack until it stops. Remove the I /O Baseboard Assembly" (page 69). 4. See "Removing the I /O baseboard assembly from the Rack" (page 58). 2. Locate the system battery on the system battery and how to observe this warning can explode if mistreated. You must reset these steps: 1. See "Extend the Server from the chassis. See "Removing...
... rack until it stops. Remove the I /O Baseboard Assembly" (page 69). 4. See "Removing the I /O baseboard assembly from the Rack" (page 58). 2. Locate the system battery on the system battery and how to observe this warning can explode if mistreated. You must reset these steps: 1. See "Extend the Server from the chassis. See "Removing...
User Service Guide, Fifth Edition - HP 9000 rp4410/4440
Page 73
...system. Unplug the power cord. Installing Additional Components 73 c. Replace the top cover. To verify that you installed the system battery correctly once you installed the system battery correctly. 10. d. If necessary, reconfigure the iLO MP. See "Console Setup" (page 104). Run the DATE command ... and date are now correct, you set the time and date, follow these steps: a. b. Figure 3-18 System Battery Location on . The battery is designated by the plus (+) sign facing up the battery holder retaining clip with a flat-head screwdriver and push on the back of the...
...system. Unplug the power cord. Installing Additional Components 73 c. Replace the top cover. To verify that you installed the system battery correctly once you installed the system battery correctly. 10. d. If necessary, reconfigure the iLO MP. See "Console Setup" (page 104). Run the DATE command ... and date are now correct, you set the time and date, follow these steps: a. b. Figure 3-18 System Battery Location on . The battery is designated by the plus (+) sign facing up the battery holder retaining clip with a flat-head screwdriver and push on the back of the...
User Service Guide, Fifth Edition - HP 9000 rp4410/4440
Page 180
... plate on the lever). 4. Replace the I /O Baseboard Assembly" (page 177). See "Replacing the I /O baseboard assembly. WARNING! Replace the battery with the mounting hole on the metal plate that is installed and operating correctly. Follow the manufacturer's recommendations. To set the time and date or... I/O baseboard assembly or installed a new I /O baseboard locking lever is positioned on the locking lever using the iLO MP, see the HP Integrity and HP 9000 iLO MP Operations Guide. 14. Using the system console, set up the iLO MP as needed. See "Removing the I /O ...
... plate on the lever). 4. Replace the I /O Baseboard Assembly" (page 177). See "Replacing the I /O baseboard assembly. WARNING! Replace the battery with the mounting hole on the metal plate that is installed and operating correctly. Follow the manufacturer's recommendations. To set the time and date or... I/O baseboard assembly or installed a new I /O baseboard locking lever is positioned on the locking lever using the iLO MP, see the HP Integrity and HP 9000 iLO MP Operations Guide. 14. Using the system console, set up the iLO MP as needed. See "Removing the I /O ...
User Service Guide, Fifth Edition - HP 9000 rp4410/4440
Page 181
... the server out from the chassis. Remove the I /O Baseboard 5. These values need to be reset after replacing the battery. Locate the system battery on the battery holder retaining clip with a flat head screwdriver and sliding the battery into its socket. 6. Lift up on the I /O baseboard assembly from the chassis. See "Removing the I /O baseboard. See...
... the server out from the chassis. Remove the I /O Baseboard 5. These values need to be reset after replacing the battery. Locate the system battery on the battery holder retaining clip with a flat head screwdriver and sliding the battery into its socket. 6. Lift up on the I /O baseboard assembly from the chassis. See "Removing the I /O baseboard. See...
User Service Guide, Fifth Edition - HP 9000 rp4410/4440
Page 182
...active slot location. Reset the server time and date, and restore the iLO MP configuration settings. Removing and Replacing PCI/PCI-X Cards HP 9000 rp4410 and rp4440 servers can contain up to I /O baseboard to blink and act as the removed card. This operation is always initiated ...slots. • Online Addition (OLA) Installing new PCI/PCI-X expansion cards in the server. 182 Removing and Replacing Components Two of the battery is installed with the new card. This action requires suspending the associated driver. NOTE: The positive terminal of these cards are numbered from ...
...active slot location. Reset the server time and date, and restore the iLO MP configuration settings. Removing and Replacing PCI/PCI-X Cards HP 9000 rp4410 and rp4440 servers can contain up to I /O baseboard to blink and act as the removed card. This operation is always initiated ...slots. • Online Addition (OLA) Installing new PCI/PCI-X expansion cards in the server. 182 Removing and Replacing Components Two of the battery is installed with the new card. This action requires suspending the associated driver. NOTE: The positive terminal of these cards are numbered from ...