Page 61
... Available settings utility Branch circuit voltage (VAC) rating (A) 100, 110, 120, 127 30 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 20 240 R/T3000 INTL 50/60 200/208, 220, 230, 16 240 1 The output voltage is 204 for this setting.
... Available settings utility Branch circuit voltage (VAC) rating (A) 100, 110, 120, 127 30 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 20 240 R/T3000 INTL 50/60 200/208, 220, 230, 16 240 1 The output voltage is 204 for this setting.
HP R/T3000 G2 UPS User Guide
Page 62
... 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model VA R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL 2880 / 2400 3300 3300 Nominal power rating (W) 2700 / 2250 3000 3000 Nominal voltage setting 120/100 204 230 Output tolerance specifications Source...Regulation -10% to +6% of nominal output voltage rating (within the guidelines of the Computer Business Equipment Manufacturers Association) ±5% of 120 V. R/T3000 INTL - - - Load segment - 2 - 1 - 2 - Specifications 62 The battery modules have a battery string voltage of nominal output voltage rating ...
... 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model VA R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL 2880 / 2400 3300 3300 Nominal power rating (W) 2700 / 2250 3000 3000 Nominal voltage setting 120/100 204 230 Output tolerance specifications Source...Regulation -10% to +6% of nominal output voltage rating (within the guidelines of the Computer Business Equipment Manufacturers Association) ±5% of 120 V. R/T3000 INTL - - - Load segment - 2 - 1 - 2 - Specifications 62 The battery modules have a battery string voltage of nominal output voltage rating ...
HP R/T3000 G2 UPS User Guide
Page 64
UPS spare parts list Item Description 1 UPS unit a) NA/JPN b) HV NA/JPN* c) INTL* 2 UPS Network Module 3 Battery module 4 Mounting rails with screws* 5 UPS/ERM mounting brackets* 6 Cord retention clips (6)* 7 Serial download cable* * not shown Spare part number - 638840-001 638841-001 638842-001 636934-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 64 To replace parts under warranty, contact an HP authorized service representative. Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts).
UPS spare parts list Item Description 1 UPS unit a) NA/JPN b) HV NA/JPN* c) INTL* 2 UPS Network Module 3 Battery module 4 Mounting rails with screws* 5 UPS/ERM mounting brackets* 6 Cord retention clips (6)* 7 Serial download cable* * not shown Spare part number - 638840-001 638841-001 638842-001 636934-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 64 To replace parts under warranty, contact an HP authorized service representative. Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts).
HP UPS R/T3000 G2 Installation Instructions
Page 2
...normal operation. IMPORTANT: Do not use of the rack rests on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for any reason. NOTE: All models ship with an L6-20 plug and one C13 extension bar. • The R/T3000... INTL model has an IEC-20-C19 input power receptacle for a country-specific cord and one component is a single-rack installation. • The racks are extended ...
...normal operation. IMPORTANT: Do not use of the rack rests on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for any reason. NOTE: All models ship with an L6-20 plug and one C13 extension bar. • The R/T3000... INTL model has an IEC-20-C19 input power receptacle for a country-specific cord and one component is a single-rack installation. • The racks are extended ...
HP UPS R/T3000 Installation Instructions
Page 2
...between the UPS communications port and the serial port on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for directions. 2. When selecting a site, consider the following factors: • Elevated operating ambient temperature-If the ...T3000h NA/JPN models ship with a nondetachable input power cord with an L6-20 plug and one C13 extension bar. • The R/T3000 INTL model has an IEC-20-C19 input power receptacle for installation: • Phillips screwdriver • 10-mm hex-nut driver The following items...
...between the UPS communications port and the serial port on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for directions. 2. When selecting a site, consider the following factors: • Elevated operating ambient temperature-If the ...T3000h NA/JPN models ship with a nondetachable input power cord with an L6-20 plug and one C13 extension bar. • The R/T3000 INTL model has an IEC-20-C19 input power receptacle for installation: • Phillips screwdriver • 10-mm hex-nut driver The following items...
HP R/T2200 UPS User Guide
Page 3
Contents Component identification ...6 UPS front panel ...6 UPS front panel controls and LED indicators 7 UPS R/T2200 NA/JPN/TWN rear panel...8 UPS R/T2200 INTL rear panel ...9 REPO port ...10 Installation ...12 Precautions...12 Preparing to install the hardware...12 Required tools ...12 Selecting a site...12 Readying the equipment ...13 ...
Contents Component identification ...6 UPS front panel ...6 UPS front panel controls and LED indicators 7 UPS R/T2200 NA/JPN/TWN rear panel...8 UPS R/T2200 INTL rear panel ...9 REPO port ...10 Installation ...12 Precautions...12 Preparing to install the hardware...12 Required tools ...12 Selecting a site...12 Readying the equipment ...13 ...
HP R/T2200 UPS User Guide
Page 9
... switches Power sensitivity adjustment dial Ground bonding screw ERM connector For information about controlling load segments remotely, see "Power management software (on page 32)." UPS R/T2200 INTL rear panel Item 1 2 Description Load segment 1 (one IEC-320-C13 output receptacle for surge and battery backup protection) Load segment 2 (one NEMA 5-20 output receptacle...
... switches Power sensitivity adjustment dial Ground bonding screw ERM connector For information about controlling load segments remotely, see "Power management software (on page 32)." UPS R/T2200 INTL rear panel Item 1 2 Description Load segment 1 (one IEC-320-C13 output receptacle for surge and battery backup protection) Load segment 2 (one NEMA 5-20 output receptacle...
HP R/T2200 UPS User Guide
Page 20
... is inactive and does not affect UPS operation regardless of the UPS. Output voltage Input voltage range DIP switch 1 DIP switch 2 DIP switch 3 DIP switch 4 R/T2200 120 V* (NA) 108-127 V Up Up Up* Up NA/JPN/TW N 110 V 99-116 V Up Down - - 100 V* 90-106 V Down Up - - (JPN.../TWN) 120 V 108-127 V Down Down Down Down R/T2200 INTL 230 V 20-7243 V Up Up Up* Up 230 V* (INTL) 207-243 V Up Down - - 220 V 198-233 V Down Up - - 240 V 216-254 V Down Down Down Down Connecting the host computer ...
... is inactive and does not affect UPS operation regardless of the UPS. Output voltage Input voltage range DIP switch 1 DIP switch 2 DIP switch 3 DIP switch 4 R/T2200 120 V* (NA) 108-127 V Up Up Up* Up NA/JPN/TW N 110 V 99-116 V Up Down - - 100 V* 90-106 V Down Up - - (JPN.../TWN) 120 V 108-127 V Down Down Down Down R/T2200 INTL 230 V 20-7243 V Up Up Up* Up 230 V* (INTL) 207-243 V Up Down - - 220 V 198-233 V Down Up - - 240 V 216-254 V Down Down Down Down Connecting the host computer ...
HP R/T2200 UPS User Guide
Page 21
... host computer. The software user guide is available for download from the HP website (http://www.hp.com/go /rackandpower) to a host computer using HPPM, connect the Management Server to an unswitched output receptacle ("UPS R/T2200 INTL rear panel" on page 9, "UPS R/T2200 NA/JPN/TWN rear panel" on the host computer. IMPORTANT: Power management...
... host computer. The software user guide is available for download from the HP website (http://www.hp.com/go /rackandpower) to a host computer using HPPM, connect the Management Server to an unswitched output receptacle ("UPS R/T2200 INTL rear panel" on page 9, "UPS R/T2200 NA/JPN/TWN rear panel" on the host computer. IMPORTANT: Power management...
HP R/T2200 UPS User Guide
Page 23
...; Plug the input line cord into the UPS output receptacles. For more information about receptacle control, see "Power management software (on the UPS rear panel (INTL model only). 2. Connecting devices to the UPS CAUTION: Do not plug laser printers into a grounded (earthed) electrical outlet that is installed near the equipment and...
...; Plug the input line cord into the UPS output receptacles. For more information about receptacle control, see "Power management software (on the UPS rear panel (INTL model only). 2. Connecting devices to the UPS CAUTION: Do not plug laser printers into a grounded (earthed) electrical outlet that is installed near the equipment and...
HP R/T2200 UPS User Guide
Page 24
... not overload by 100) to : • 90% of their capacity within 4 hours • 100% of the UPS using the jumper cords included with the UPS (INTL model). If the equipment rating is available at least 24 hours before supplying backup power to charge before putting the UPS into service. Installation 24...
... not overload by 100) to : • 90% of their capacity within 4 hours • 100% of the UPS using the jumper cords included with the UPS (INTL model). If the equipment rating is available at least 24 hours before supplying backup power to charge before putting the UPS into service. Installation 24...
HP R/T2200 UPS User Guide
Page 31
... discharge. UPS operations 31 As the dial is turned clockwise, the UPS becomes more tolerant of rear panel components, see "UPS R/T2200 NA/JPN/TWN rear panel (on page 8)" or "UPS R/T2200 INTL rear panel (on page 9)." Shut down the UPS 1. For the location of variations in a safe test mode so the effects...
... discharge. UPS operations 31 As the dial is turned clockwise, the UPS becomes more tolerant of rear panel components, see "UPS R/T2200 NA/JPN/TWN rear panel (on page 8)" or "UPS R/T2200 INTL rear panel (on page 9)." Shut down the UPS 1. For the location of variations in a safe test mode so the effects...
HP R/T2200 UPS User Guide
Page 40
... (A) 20 15 Line cord Nondetachable power cord with NEMA 5-20 plug Detachable power cord with IEC-320-C20 plug UPS output specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Output receptacles 4 x NEMA 5-15R, 4 x NEMA 515/20R 8 x IEC-320-C13 Maximum current 18.3 A 9.5 A Specifications 40 Specifications UPS physical specifications Parameter Height Depth Width...
... (A) 20 15 Line cord Nondetachable power cord with NEMA 5-20 plug Detachable power cord with IEC-320-C20 plug UPS output specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Output receptacles 4 x NEMA 5-15R, 4 x NEMA 515/20R 8 x IEC-320-C13 Maximum current 18.3 A 9.5 A Specifications 40 Specifications UPS physical specifications Parameter Height Depth Width...
HP R/T2200 UPS User Guide
Page 41
Specifications 41 Power protection specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL VA 2200 2200 Nominal power Nominal voltage rating (W) setting 1600 100, 110, 120 1600 220, 230, 240 Voltage specifications Configuration setting (VAC) 100 110 120 ...
Specifications 41 Power protection specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL VA 2200 2200 Nominal power Nominal voltage rating (W) setting 1600 100, 110, 120 1600 220, 230, 240 Voltage specifications Configuration setting (VAC) 100 110 120 ...
HP R/T2200 UPS User Guide
Page 43
Spares 43 To replace parts under warranty, contact an HP authorized service representative. Spares Ordering spares To order a spare, visit the HP website (http://h61003.www6.hp.com). Spare parts list Item UPS unit NA UPS unit JPN/TWN UPS unit INTL ERM unit UPS/ERM tower stand UPS/ERM mounting hardware UPS battery Spare part number 410039-001 410040-291 410041-B31 410045-001 410042-001 415694-001 416727-001 Hardware options For information on the supported hardware options, see the HP website (http://www.hp.com/go/rackandpower).
Spares 43 To replace parts under warranty, contact an HP authorized service representative. Spares Ordering spares To order a spare, visit the HP website (http://h61003.www6.hp.com). Spare parts list Item UPS unit NA UPS unit JPN/TWN UPS unit INTL ERM unit UPS/ERM tower stand UPS/ERM mounting hardware UPS battery Spare part number 410039-001 410040-291 410041-B31 410045-001 410042-001 415694-001 416727-001 Hardware options For information on the supported hardware options, see the HP website (http://www.hp.com/go/rackandpower).
HP R/T2200 UPS User Guide
Page 54
... button 7 power protection specifications 41 power sensitivity adjustment dial, location 8, 9 power sensitivity adjustment dial, setting 30 powering down 31 powering up 24 problem diagnosis 37 R R/T2200 INTL 7, 9 R/T2200 NA/JPN/TWN 7, 8 rack-to-tower conversion 13, 24 rear panel components 8, 9 regulatory compliance identification numbers 46 regulatory compliance notices 46, 48 replacing the batteries...
... button 7 power protection specifications 41 power sensitivity adjustment dial, location 8, 9 power sensitivity adjustment dial, setting 30 powering down 31 powering up 24 problem diagnosis 37 R R/T2200 INTL 7, 9 R/T2200 NA/JPN/TWN 7, 8 rack-to-tower conversion 13, 24 rear panel components 8, 9 regulatory compliance identification numbers 46 regulatory compliance notices 46, 48 replacing the batteries...
HP UPS R/T3000 User Guide
Page 59
... voltage frequency (Hz) 50/60 Available settings utility voltage (VAC) 100, 110, 120, 127 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 240 R/T3000 INTL 50/60 200/208, 220, 230, 240 1 The output voltage is 204 for this setting. Branch circuit rating (A) 30 20 16 Line cord Nondetachable power...
... voltage frequency (Hz) 50/60 Available settings utility voltage (VAC) 100, 110, 120, 127 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 240 R/T3000 INTL 50/60 200/208, 220, 230, 240 1 The output voltage is 204 for this setting. Branch circuit rating (A) 30 20 16 Line cord Nondetachable power...
HP UPS R/T3000 User Guide
Page 60
...-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL VA 2880 3300 3300 Nominal power rating (W) 2700 Nominal voltage setting 100, 110, 120, 127 3000 204, 220, 230, 240 3000 204, 220, 230, 240...
...-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL VA 2880 3300 3300 Nominal power rating (W) 2700 Nominal voltage setting 100, 110, 120, 127 3000 204, 220, 230, 240 3000 204, 220, 230, 240...
HP UPS R/T3000 User Guide
Page 63
Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). To replace parts under warranty, contact an HP authorized service representative. UPS spare parts list Item Description 1 UPS unit NA/JPN * UPS unit HV NA/JPN * UPS unit INTL 2 X-slot serial card 3 Battery module * Mounting rails with screws * UPS/ERM mounting brackets * Cord retention clips * Serial download cable * not shown Spare part number 517699-001 517700-001 517701-001 419180-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 63
Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). To replace parts under warranty, contact an HP authorized service representative. UPS spare parts list Item Description 1 UPS unit NA/JPN * UPS unit HV NA/JPN * UPS unit INTL 2 X-slot serial card 3 Battery module * Mounting rails with screws * UPS/ERM mounting brackets * Cord retention clips * Serial download cable * not shown Spare part number 517699-001 517700-001 517701-001 419180-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 63
HP UPS R/T3000 User Guide
Page 79
R/T3000 INTL 11 R/T3000 models 9 R/T3000 NA 9 R/T3000h JPN 10 R/T3000h NA 10 R/T3000j JPN 9 rack-to-tower conversion 26, 35 rails, installing 14 rear panel connectors 9, ...
R/T3000 INTL 11 R/T3000 models 9 R/T3000 NA 9 R/T3000h JPN 10 R/T3000h NA 10 R/T3000j JPN 9 rack-to-tower conversion 26, 35 rails, installing 14 rear panel connectors 9, ...