embedded web server user guide
Page 5
... Parameters for the Product 4-11 Viewing Fabric Information 4-12 Viewing Operating Parameters for a Fabric 4-12 Viewing Fabric Directors and Switches 4-13 Parts of the Product Cell 4-14 Product Cell Information 4-15 Parts of the Product Graphic 4-16 Viewing Fabric Topology 4-18 5 Monitoring Products Monitoring Ports 5-1 Port List 5-1 Port Operational States 5-2 Accessing Port Statistics...
... Parameters for the Product 4-11 Viewing Fabric Information 4-12 Viewing Operating Parameters for a Fabric 4-12 Viewing Fabric Directors and Switches 4-13 Parts of the Product Cell 4-14 Product Cell Information 4-15 Parts of the Product Graphic 4-16 Viewing Fabric Topology 4-18 5 Monitoring Products Monitoring Ports 5-1 Port List 5-1 Port Operational States 5-2 Accessing Port Statistics...
embedded web server user guide
Page 9
...document suite that came with the product. For the latest information, documentation, and firmware releases, please visit the following StorageWorks website: http://h18006.www1.hp.com/storage/saninfrastructure.html For information about Fibre Channel standards, visit the Fibre Channel Association website, located at http://www... operation. Intended Audience This book is part of the Release Notes that supports the Hewlett-Packard (HP) StorageWorks Director 2/64, Director 2/140, Edge Switch 2/16, Edge Switch 2/32, Edge Switch 2/24, and the Embedded Web Server (EWS) application.
...document suite that came with the product. For the latest information, documentation, and firmware releases, please visit the following StorageWorks website: http://h18006.www1.hp.com/storage/saninfrastructure.html For information about Fibre Channel standards, visit the Fibre Channel Association website, located at http://www... operation. Intended Audience This book is part of the Release Notes that supports the Hewlett-Packard (HP) StorageWorks Director 2/64, Director 2/140, Edge Switch 2/16, Edge Switch 2/32, Edge Switch 2/24, and the Embedded Web Server (EWS) application.
embedded web server user guide
Page 32
...10-100 km). If the values are not identical, the E_Port connection to -buffer credit (BB_Credit) from the navigation panel. 3. Click the Switch or Director tab (as appropriate), then click the Fabric Parameters tab. At the BB_Credit field, type a value between 2 through 600 tenths of a second...attached to a fabric element, the product and element must be set to industry specification, Fibre Channel Physical and Signaling Interface. This is 16. Choose Configure from 1 through 120 seconds). (The R_A_TOV value must be greater than the R_A_TOV value.) 2-10 embedded web server ...
...10-100 km). If the values are not identical, the E_Port connection to -buffer credit (BB_Credit) from the navigation panel. 3. Click the Switch or Director tab (as appropriate), then click the Fabric Parameters tab. At the BB_Credit field, type a value between 2 through 600 tenths of a second...attached to a fabric element, the product and element must be set to industry specification, Fibre Channel Physical and Signaling Interface. This is 16. Choose Configure from 1 through 120 seconds). (The R_A_TOV value must be greater than the R_A_TOV value.) 2-10 embedded web server ...
embedded web server user guide
Page 38
... field in four-byte, dotted-decimal format. Type a decimal port number in the Write Authorization column to the SNMP configuration have been successfully activated displays. 2-16 embedded web server user guide For each trap recipient to be sent to SNMP management stations when unauthorized stations try to prevent unauthorized viewing or...
... field in four-byte, dotted-decimal format. Type a decimal port number in the Write Authorization column to the SNMP configuration have been successfully activated displays. 2-16 embedded web server user guide For each trap recipient to be sent to SNMP management stations when unauthorized stations try to prevent unauthorized viewing or...
embedded web server user guide
Page 42
...function, they will receive a login password dialog box indicating the rights (either administrator or operator) required to continue using EWS. Use 16 alphanumeric characters or less. Type the operator password (as specified by EWS along with the message Your changes to the User Rights ...the access permissions for user name and password are implemented. Configuring the Product 3. For the Administrator set of data fields: a. c. Use 16 alphanumeric characters or less. c. Type the operator password again in the Confirm New Password field. 4. Login may need to log into ...
...function, they will receive a login password dialog box indicating the rights (either administrator or operator) required to continue using EWS. Use 16 alphanumeric characters or less. Type the operator password (as specified by EWS along with the message Your changes to the User Rights ...the access permissions for user name and password are implemented. Configuring the Product 3. For the Administrator set of data fields: a. c. Use 16 alphanumeric characters or less. c. Type the operator password again in the Confirm New Password field. 4. Login may need to log into ...
embedded web server user guide
Page 53
...spare ports. When you define a zone member by port number, use the 16-digit WWN of the managed product. Using Port Numbers To identify a zone member by a port number, any device attached through n, with the Switch or Director manufacturer's name before the WWN. The advantage of identifying a zone member by... 1 NOTE: Port numbers cannot be assigned to ports are using the HAFM Product Manager, not EWS. Port numbers can be used for the Switch or Director is assigned to Open Fabric 1.0 mode. For example: 10:00:08:00:88:40:C0:D4 In EWS the WWN displays with n representing...
...spare ports. When you define a zone member by port number, use the 16-digit WWN of the managed product. Using Port Numbers To identify a zone member by a port number, any device attached through n, with the Switch or Director manufacturer's name before the WWN. The advantage of identifying a zone member by... 1 NOTE: Port numbers cannot be assigned to ports are using the HAFM Product Manager, not EWS. Port numbers can be used for the Switch or Director is assigned to Open Fabric 1.0 mode. For example: 10:00:08:00:88:40:C0:D4 In EWS the WWN displays with n representing...
embedded web server user guide
Page 68
...operational, online, offline, port failure, segmented E_Port, testing, or not installed. 4-6 embedded web server user guide G_port - Valid only on the Edge Switch 2/24. • Operational State - This field indicates the beaconing status for the port as either a Fabric Loop Port or a Fabric Port. ...The Port Properties page provides the following information: • Port Number - The port's 16-digit WWN. • Attached Port WWN - Fibre Channel WWN identifier of the device attached to another switch's E_Port through an ISL. - The physical port number. • Port Name - This...
...operational, online, offline, port failure, segmented E_Port, testing, or not installed. 4-6 embedded web server user guide G_port - Valid only on the Edge Switch 2/24. • Operational State - This field indicates the beaconing status for the port as either a Fabric Loop Port or a Fabric Port. ...The Port Properties page provides the following information: • Port Number - The port's 16-digit WWN. • Attached Port WWN - Fibre Channel WWN identifier of the device attached to another switch's E_Port through an ISL. - The physical port number. • Port Name - This...
embedded web server user guide
Page 76
...manually to view the Topology page. (The hyperlink is found only on the Edge Switch 2/16, Edge Switch 2/32, Edge Switch 2/24, Director 2/64, and Director 2/140.) Other HP high availability fabric Directors and Switches and non-HP products do not have this capability. For more information, see Parts of the ...has the following parts: • A graphic representation of the device and its status. Each device on page 4-16. • Information about other switches in the fabric through in the product cells reflects the state of the window. For more information, see the next...
...manually to view the Topology page. (The hyperlink is found only on the Edge Switch 2/16, Edge Switch 2/32, Edge Switch 2/24, Director 2/64, and Director 2/140.) Other HP high availability fabric Directors and Switches and non-HP products do not have this capability. For more information, see Parts of the ...has the following parts: • A graphic representation of the device and its status. Each device on page 4-16. • Information about other switches in the fabric through in the product cells reflects the state of the window. For more information, see the next...
embedded web server user guide
Page 77
... ID of the product used in the fabric. WWN of the product used in the fabric. Availability Available for any product. The following HP high availability fabric Directors and Switches only: • Edge Switch 2/16 • Edge Switch 2/32 • Edge Switch 2/24 • Director 2/64 • Director 2/140 embedded web server user guide 4-15 IP addresses of the product.
... ID of the product used in the fabric. WWN of the product used in the fabric. Availability Available for any product. The following HP high availability fabric Directors and Switches only: • Edge Switch 2/16 • Edge Switch 2/32 • Edge Switch 2/24 • Director 2/64 • Director 2/140 embedded web server user guide 4-15 IP addresses of the product.
embedded web server user guide
Page 78
...in the fabric have a generic product graphic. Edge Switch 2/24 - You can click the graphic to the device's Default Page. 4-16 embedded web server user guide All other HP Directors and Switches in the graphic is one of the product. Edge Switch 2/32 - Generic product. The generic product graphic ...product. • A graphic representing the status of the product. • An icon representing the appearance of the following HP high availability fabric Directors and Switches, the graphic shows an icon that represents the actual product. Edge Switch 2/16 - Director 2/140 -
...in the fabric have a generic product graphic. Edge Switch 2/24 - You can click the graphic to the device's Default Page. 4-16 embedded web server user guide All other HP Directors and Switches in the graphic is one of the product. Edge Switch 2/32 - Generic product. The generic product graphic ...product. • A graphic representing the status of the product. • An icon representing the appearance of the following HP high availability fabric Directors and Switches, the graphic shows an icon that represents the actual product. Edge Switch 2/16 - Director 2/140 -
embedded web server user guide
Page 92
Choose the Node List tab; Figure 5-4: Node List tab view Information displayed for each node includes: • Port - The 16-digit WWN assigned to -buffer credit the attached node has available. • Data Field Size - Fibre Channel address, which is shown only if there ... can process. • FC Address - Otherwise, all node attachments or N_Ports that shows a list of public and private loop-attached devices. For the Edge Switch 2/24, this value is a single attached device on a loop for the port. The Node List tab view displays information about all Fibre Channel address information...
Choose the Node List tab; Figure 5-4: Node List tab view Information displayed for each node includes: • Port - The 16-digit WWN assigned to -buffer credit the attached node has available. • Data Field Size - Fibre Channel address, which is shown only if there ... can process. • FC Address - Otherwise, all node attachments or N_Ports that shows a list of public and private loop-attached devices. For the Edge Switch 2/24, this value is a single attached device on a loop for the port. The Node List tab view displays information about all Fibre Channel address information...
embedded web server user guide
Page 110
.... If spaces are : • 0-15 for the Edge Switch 2/16 • 0-23 for the Edge Switch 2/24 • 0-31 for the Edge Switch 2/32 • 0-63 for the Director 2/64 • 0-127 and 132-144 for the switch location is invalid. Enter a contact with 0-255 characters and ...re-submit. Error Messages Message Error 10: Invalid Switch Location Description The value entered for the Director 2/140...
.... If spaces are : • 0-15 for the Edge Switch 2/16 • 0-23 for the Edge Switch 2/24 • 0-31 for the Edge Switch 2/32 • 0-63 for the Director 2/64 • 0-127 and 132-144 for the switch location is invalid. Enter a contact with 0-255 characters and ...re-submit. Error Messages Message Error 10: Invalid Switch Location Description The value entered for the Director 2/140...
embedded web server user guide
Page 111
... must be entered as an integer in the range of 1-60. Error Messages Message Error 14: Invalid Port Name Error 15: Invalid BB Credit Error 16: Invalid R_A_TOV Error 15: Invalid BB Credit Error 16: Invalid R_A_TOV Description The value entered for the individual port may contain 0-24 characters.
... must be entered as an integer in the range of 1-60. Error Messages Message Error 14: Invalid Port Name Error 15: Invalid BB Credit Error 16: Invalid R_A_TOV Error 15: Invalid BB Credit Error 16: Invalid R_A_TOV Description The value entered for the individual port may contain 0-24 characters.
embedded web server user guide
Page 124
... client. Error Messages Message Error 155: Cannot Remove Active Member From List Error 156: Cannot Disable Fabric Binding while Switch is Online Error 201: Change Authorization Request Failed Error 202: Invalid Change Authorization ID Description This member cannot be removed...have been entered correctly and re-submit. Contact your service representative with further problems. A-16 embedded web server user guide Deactivating fabric binding is attached and re-submitting the request. The switch will not accept a change request from the membership list, then there are several ...
... client. Error Messages Message Error 155: Cannot Remove Active Member From List Error 156: Cannot Disable Fabric Binding while Switch is Online Error 201: Change Authorization Request Failed Error 202: Invalid Change Authorization ID Description This member cannot be removed...have been entered correctly and re-submit. Contact your service representative with further problems. A-16 embedded web server user guide Deactivating fabric binding is attached and re-submitting the request. The switch will not accept a change request from the membership list, then there are several ...
embedded web server user guide
Page 126
The value entered for the Director 2/140 A port may be a reduction in the number of the zone set to be an eport, gport, or fport. Reduce the size of zones in the zone set has outgrown the size limitations imposed by your Director or Switch. This can be configured to meet CLI requirements...range supported by the Command Line Interface. Valid values are: • 0-15 for the Edge Switch 2/16 • 0-23 for the Edge Switch 2/24 • 0-31 for the Edge Switch 2/32 • 0-63 for the Director 2/64 • 0-127 and 132-144 for the port number is invalid The port type configured...
The value entered for the Director 2/140 A port may be a reduction in the number of the zone set to be an eport, gport, or fport. Reduce the size of zones in the zone set has outgrown the size limitations imposed by your Director or Switch. This can be configured to meet CLI requirements...range supported by the Command Line Interface. Valid values are: • 0-15 for the Edge Switch 2/16 • 0-23 for the Edge Switch 2/24 • 0-31 for the Edge Switch 2/32 • 0-63 for the Director 2/64 • 0-127 and 132-144 for the port number is invalid The port type configured...
embedded web server user guide
Page 146
... to which a device sends frames destined for addresses not on the same physical network (for network users and manages access to a Director or Switch or Switch port. file server A computer that data. FPM See fibre port module. Assembly removed and replaced in frame relay technology. See active...that use the same or different protocols. (2) In TCP/IP, the address of the Director or Switch is faster than read-only memory, but slower than random access memory (D). Glossary-16 embedded web server user guide FLASH memory is provided through the Product Manager application. FRU ...
... to which a device sends frames destined for addresses not on the same physical network (for network users and manages access to a Director or Switch or Switch port. file server A computer that data. FPM See fibre port module. Assembly removed and replaced in frame relay technology. See active...that use the same or different protocols. (2) In TCP/IP, the address of the Director or Switch is faster than read-only memory, but slower than random access memory (D). Glossary-16 embedded web server user guide FLASH memory is provided through the Product Manager application. FRU ...
embedded web server user guide
Page 167
... to allow devices to access the LAN for data transmission (D). trap host Simple network management protocol (SNMP) management workstation that provides a port to connect a Director or Switch to a 4/16 Mbps token ring local area network (LAN) (D). A token (unique sequence of applications among devices on a high-speed local area network (LAN) communication environment (D). See...
... to allow devices to access the LAN for data transmission (D). trap host Simple network management protocol (SNMP) management workstation that provides a port to connect a Director or Switch to a 4/16 Mbps token ring local area network (LAN) (D). A token (unique sequence of applications among devices on a high-speed local area network (LAN) communication environment (D). See...
embedded web server user guide
Page 171
... table 2-13 administrator rights 2-20 administrator-level ID 2-19 alert symbols 4-4 ARP table 2-13 attached port WWN 4-6 audience ix authorization traps 2-16 B BB_Credit 2-4, 2-10, 4-12, 5-10 Beacon tab view 6-2, 6-5 beaconing 4-6 activation 6-2 ports 6-5 binding overview 3-4 block configuration 4-6, ...light 5-9 CLI 1-2 enable and disable 2-17 tab view 2-17 codes, error event 5-9 command line interface 2-17 community name 2-16 Configure page 2-1 configure ports 2-2 configuring fabric parameters 2-9 identification 2-5 network information 2-12 product identification 2-5 SNMP 2-15 zone sets ...
... table 2-13 administrator rights 2-20 administrator-level ID 2-19 alert symbols 4-4 ARP table 2-13 attached port WWN 4-6 audience ix authorization traps 2-16 B BB_Credit 2-4, 2-10, 4-12, 5-10 Beacon tab view 6-2, 6-5 beaconing 4-6 activation 6-2 ports 6-5 binding overview 3-4 block configuration 4-6, ...light 5-9 CLI 1-2 enable and disable 2-17 tab view 2-17 codes, error event 5-9 command line interface 2-17 community name 2-16 Configure page 2-1 configure ports 2-2 configuring fabric parameters 2-9 identification 2-5 network information 2-12 product identification 2-5 SNMP 2-15 zone sets ...
embedded web server user guide
Page 172
...2-6, 4-10 destination domain ID 4-19 devices on loop 5-10 diagnostic, loopback 6-7 Diagnostics tab view 6-7 diamond, red meaning of 4-17 Director 2/140 2-2 Director speed 4-12 disable CLI 2-17 host control 2-18 zone set 3-15 zoning 3-9 discard changes 3-15 distance capability 4-8 document conventions x ...Web Server benefits of 1-4 description 1-1 interface terminology 1-3 login 1-8 starting 1-7 tasks 1-1 where to start 1-7 enable authorization traps 2-16 CLI 2-17 host control 2-18 engineering change level 4-10 Enter Network Password dialog box 1-8, 2-19 equipment symbols xi Error Detection Time...
...2-6, 4-10 destination domain ID 4-19 devices on loop 5-10 diagnostic, loopback 6-7 Diagnostics tab view 6-7 diamond, red meaning of 4-17 Director 2/140 2-2 Director speed 4-12 disable CLI 2-17 host control 2-18 zone set 3-15 zoning 3-9 discard changes 3-15 distance capability 4-8 document conventions x ...Web Server benefits of 1-4 description 1-1 interface terminology 1-3 login 1-8 starting 1-7 tasks 1-1 where to start 1-7 enable authorization traps 2-16 CLI 2-17 host control 2-18 engineering change level 4-10 Enter Network Password dialog box 1-8, 2-19 equipment symbols xi Error Detection Time...