Error Prevention Guide
Page 5
... tray or other cable routing system is available for server BIOS, drivers, and agents. Anticipate the utilization rate and distribute servers based on enterprise class servers, high availability features such as Hot-Pluggable RAID memory functionality and Hot-Plug PCI slots effectively minimize the amount.... Software Updates Stay aware of downtime experienced due to minimize the impact of Insight Manager 7. Server Design Design the server setup to memory or PCI card upgrades. If you require. 6 Error Prevention Guide Minimizing the Impact of Changes Version Control Keep track...
... tray or other cable routing system is available for server BIOS, drivers, and agents. Anticipate the utilization rate and distribute servers based on enterprise class servers, high availability features such as Hot-Pluggable RAID memory functionality and Hot-Plug PCI slots effectively minimize the amount.... Software Updates Stay aware of downtime experienced due to minimize the impact of Insight Manager 7. Server Design Design the server setup to memory or PCI card upgrades. If you require. 6 Error Prevention Guide Minimizing the Impact of Changes Version Control Keep track...
HP 2100S SCSI RAID - User Guide (337208-001)
Page 14
...software • Operating system independent configuration and RAID creation using the Storage Manager on ROM (SMOR) utility • Support for easy upgrades of controller firmware, I2O BIOS and SMOR • Event logging • Predictive caching that analyzes disk read requests made by the ... the pattern to predict which data the host is likely to -peak maximum • 2100S current (typical): 3.4A • Memory module current (typical): 0.2A 2-2 HP 2100S SCSI RAID Controller User Guide RAID 1 and RAID 5 arrays are available on a controller, the intelligent hot-spare algorithm picks...
...software • Operating system independent configuration and RAID creation using the Storage Manager on ROM (SMOR) utility • Support for easy upgrades of controller firmware, I2O BIOS and SMOR • Event logging • Predictive caching that analyzes disk read requests made by the ... the pattern to predict which data the host is likely to -peak maximum • 2100S current (typical): 3.4A • Memory module current (typical): 0.2A 2-2 HP 2100S SCSI RAID Controller User Guide RAID 1 and RAID 5 arrays are available on a controller, the intelligent hot-spare algorithm picks...
Regular Firmware Updates Essential for Optimal Performance and Functionality of HP ProLiant Servers
Page 2
... released hardware. Subscriber's Choice Subscriber's Choice is an online service that a ProLiant server is Firmware? This ensures that the system, as "firmware." HP provides regular firmware upgrades, but is also committed to creating updates as they are needed to fix an existing...ProLiant servers, hard drives, Smart Array Controllers, Remote Insight Lights-Out Edition (RILOE), Remote Insight Lights-Out Edition II (RILOE II) and Integrated Lights-Out (iLO) options have options, HP recommends checking for firmware upgrades for availability of hardware configured in Read-Only Memory (...
... released hardware. Subscriber's Choice Subscriber's Choice is an online service that a ProLiant server is Firmware? This ensures that the system, as "firmware." HP provides regular firmware upgrades, but is also committed to creating updates as they are needed to fix an existing...ProLiant servers, hard drives, Smart Array Controllers, Remote Insight Lights-Out Edition (RILOE), Remote Insight Lights-Out Edition II (RILOE II) and Integrated Lights-Out (iLO) options have options, HP recommends checking for firmware upgrades for availability of hardware configured in Read-Only Memory (...
hp server remote management card user guide
Page 17
... notification, an administrator's valuable time is kept to upgrade the firmware, a newer revision of the server. The HP Server Remote Management Card can be downloaded via email using the Simple Mail Transfer Protocol (SMTP), numeric pager, or alphanumeric pager using the Telocator Alphanumeric Protocol (TAP). Diagnostics Memory diagnostics. If enabled, this function reads continuously through...
... notification, an administrator's valuable time is kept to upgrade the firmware, a newer revision of the server. The HP Server Remote Management Card can be downloaded via email using the Simple Mail Transfer Protocol (SMTP), numeric pager, or alphanumeric pager using the Telocator Alphanumeric Protocol (TAP). Diagnostics Memory diagnostics. If enabled, this function reads continuously through...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 29
...-pin, 133 MHz, buffered, ECC, SDRAM DIMMs and ships with 8 MB standard video memory and cannot be upgraded. The EDO DIMMs and PC 100 SDRAM DIMMs from earlier HP Server models will fit into the DIMM slots in the HP Server tc3100, but the EDO DIMMs and PC 100 SDRAM will not function properly and are... parked prior to removal. Ensure you slowly pull the drive straight out. The embedded video controller is implemented using four memory slots on the system board which support...
...-pin, 133 MHz, buffered, ECC, SDRAM DIMMs and ships with 8 MB standard video memory and cannot be upgraded. The EDO DIMMs and PC 100 SDRAM DIMMs from earlier HP Server models will fit into the DIMM slots in the HP Server tc3100, but the EDO DIMMs and PC 100 SDRAM will not function properly and are... parked prior to removal. Ensure you slowly pull the drive straight out. The embedded video controller is implemented using four memory slots on the system board which support...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 108
... F fan exploded view, 96 replacing, 87 filler panels empty slots, 17 hot swap, 95 firmware upgrades, 36 flexible disk cable parts number, 101 flexible disk drive boot priority, 18 exploded view, 94 ...17 LED indicators, 4 operation status, 3 102 removing, 26 HP DiagTools utility, 69 HP Integrated Remote Assistant, 54 HP Management Solutions, 54 HP NetRaid-1M, 37 HP Remote Console, 48 HP Server configuring, 41 inrush current, 6 maintenance, 70 mass storage,...37 hard disk drives, 19-21 heatsink, 34 mass storage, 16-18 memory modules, 27-29 integrated I/O port, Setup Utility, 45 Integrated RA, 54...
... F fan exploded view, 96 replacing, 87 filler panels empty slots, 17 hot swap, 95 firmware upgrades, 36 flexible disk cable parts number, 101 flexible disk drive boot priority, 18 exploded view, 94 ...17 LED indicators, 4 operation status, 3 102 removing, 26 HP DiagTools utility, 69 HP Integrated Remote Assistant, 54 HP Management Solutions, 54 HP NetRaid-1M, 37 HP Remote Console, 48 HP Server configuring, 41 inrush current, 6 maintenance, 70 mass storage,...37 hard disk drives, 19-21 heatsink, 34 mass storage, 16-18 memory modules, 27-29 integrated I/O port, Setup Utility, 45 Integrated RA, 54...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 109
...16 SCSI installation order, 17 tape back up drive, devices, 16 memory cache, Setup Utility, 45 memory modules guidelines, 27 installing, 27-29 specifications, 105 troubleshooting problems, ... tools needed, 69 Network Interface Card (NIC), 86 network server mode, 44 NOS reconfigure, 36 sleep states, 2 Index O opening server, 13 operation status, hot swap drives, 3 optional SCSI ... power management sleep state configurations, 7 sleep states, 7 power supply applying, 5 exploded view, 96 multiple servers, 6 replacing, 88 requirements, 103 standby current, 6 powering-down, 5 powering-up, 5 power-on ...
...16 SCSI installation order, 17 tape back up drive, devices, 16 memory cache, Setup Utility, 45 memory modules guidelines, 27 installing, 27-29 specifications, 105 troubleshooting problems, ... tools needed, 69 Network Interface Card (NIC), 86 network server mode, 44 NOS reconfigure, 36 sleep states, 2 Index O opening server, 13 operation status, hot swap drives, 3 optional SCSI ... power management sleep state configurations, 7 sleep states, 7 power supply applying, 5 exploded view, 96 multiple servers, 6 replacing, 88 requirements, 103 standby current, 6 powering-down, 5 powering-up, 5 power-on ...