Installing Microsoft Small Business Server 2000 on an HP Netserver
Page 1
... Flow ( High Level View ) Installation Planning Sheet Installation Methods Automatic Installation - Microsoft Small Business Server 2000 Installation Guide for HP NetServers E60, E800, LC2000, and HP Server tc3100, and tc4100 NOTICE: The information in this document from SBS 4.0 to Small Business Server 2000 Tip #2. If you don't have the M.04.05 version CD-ROM and you...
... Flow ( High Level View ) Installation Planning Sheet Installation Methods Automatic Installation - Microsoft Small Business Server 2000 Installation Guide for HP NetServers E60, E800, LC2000, and HP Server tc3100, and tc4100 NOTICE: The information in this document from SBS 4.0 to Small Business Server 2000 Tip #2. If you don't have the M.04.05 version CD-ROM and you...
Product Update: BIOS Update Required With New Processor Steppings
Page 1
... the table above. System Processors Current Current BIOS Stepping Version HP Server tc3100 Intel Pentium III 1.26GHz, A1 1.4GHz * 4.06.15 HP Server tc4100 Intel Pentium III 1.13GHz, A1 1.26GHz, 1.4GHz * 4.06.15 HP Server LP1000r Intel Pentium III 1.13GHz, A1 HP Server LP2000r 1.26GHz, 1.4GHz * 4.06.15 RO HP Server tc2100 Intel Pentium III 1.13GHz, A1 1.20 1.26GHz and Intel...
... the table above. System Processors Current Current BIOS Stepping Version HP Server tc3100 Intel Pentium III 1.26GHz, A1 1.4GHz * 4.06.15 HP Server tc4100 Intel Pentium III 1.13GHz, A1 1.26GHz, 1.4GHz * 4.06.15 HP Server LP1000r Intel Pentium III 1.13GHz, A1 HP Server LP2000r 1.26GHz, 1.4GHz * 4.06.15 RO HP Server tc2100 Intel Pentium III 1.13GHz, A1 1.20 1.26GHz and Intel...
HP Surestore Drive Rail Mounting Kit Information
Page 1
... to Obtain Additional Installation Instructions Complete mass storage device installation instructions can be found in HP Servers. HP Part Number 5990-3463, Doc # 5990-3463-1 Revised July 2002 .'"&& ( !# ' Configuration Guidelines HP Server tc3100 Configuration The HP Server tc3100 can accept either of the following HP Surestore tape drives: Table 1. The kit also includes screw sub-kits for installation in both...
... to Obtain Additional Installation Instructions Complete mass storage device installation instructions can be found in HP Servers. HP Part Number 5990-3463, Doc # 5990-3463-1 Revised July 2002 .'"&& ( !# ' Configuration Guidelines HP Server tc3100 Configuration The HP Server tc3100 can accept either of the following HP Surestore tape drives: Table 1. The kit also includes screw sub-kits for installation in both...
HP Surestore Drive Rail Mounting Kit Information
Page 2
... rails: 1. Plastic Drive Rails HP Server tc4100 Configuration The HP Server tc4100 can accept any of the following HP Surestore tape drives: NOTE In any of rail Wire Rod Insert this wire rod end first Wire Rod Ends Apply pressure to middle of these server configurations, the CD-ROM is ...location P1 in the pedestal configuration and in location R3 in the rack mount configuration (see Figure 3). 2 HP Part Number 5990-3463 Repeat the installation for the HP Server tc3100 Installing the Plastic Rails (Models DAT 24i and DAT 40i) The plastic drive rails are secured to be inserted...
... rails: 1. Plastic Drive Rails HP Server tc4100 Configuration The HP Server tc4100 can accept any of the following HP Surestore tape drives: NOTE In any of rail Wire Rod Insert this wire rod end first Wire Rod Ends Apply pressure to middle of these server configurations, the CD-ROM is ...location P1 in the pedestal configuration and in location R3 in the rack mount configuration (see Figure 3). 2 HP Part Number 5990-3463 Repeat the installation for the HP Server tc3100 Installing the Plastic Rails (Models DAT 24i and DAT 40i) The plastic drive rails are secured to be inserted...
UnitedLinux 1.0 Installation Notes for HP Servers
Page 1
...to the installation of UnitedLinux 1.0. Installation documentation is the engine that are installing on and then choose "Download Drivers and Software". 1 Choose the HP Server you with installation procedures that powers Linux products distributed by each of these installation notes before beginning installation of UnitedLinux 1.0 on the UnitedLinux website ... by these four companies: Conectiva S.A., The SCO Group, SuSE Linux AG, and Turbolinux, Inc. Also additional information about UnitedLinux 1.0 can be found on HP Server tc2110, HP Server tc3100, and HP Server tc4100.
...to the installation of UnitedLinux 1.0. Installation documentation is the engine that are installing on and then choose "Download Drivers and Software". 1 Choose the HP Server you with installation procedures that powers Linux products distributed by each of these installation notes before beginning installation of UnitedLinux 1.0 on the UnitedLinux website ... by these four companies: Conectiva S.A., The SCO Group, SuSE Linux AG, and Turbolinux, Inc. Also additional information about UnitedLinux 1.0 can be found on HP Server tc2110, HP Server tc3100, and HP Server tc4100.
hp server tc3100 installation sheet (English)
Page 1
... the driver diskette(s) for the NOS you have replaced HP components (for first-time installations of Intel Corporation. HP Tower Server tc3100 Installation Sheet Setting Up the HP Server tc3100 Audience Assumptions This guide is for the most current installation information. u The server should boot from a third-party). Configure the HP Server and Install the Network Operating System (NOS): u During...
... the driver diskette(s) for the NOS you have replaced HP components (for first-time installations of Intel Corporation. HP Tower Server tc3100 Installation Sheet Setting Up the HP Server tc3100 Audience Assumptions This guide is for the most current installation information. u The server should boot from a third-party). Configure the HP Server and Install the Network Operating System (NOS): u During...
hp server tc3100 installation sheet (English)
Page 4
... 11. Embedded SCSI B channel (SCSI devices) 5. PCI slot 6 6. You can also access additional information and documentation from HP's external web site, either by connecting directly or through your HP Server tc3100 Online Documentation CD-ROM. Installing a Second Processor Terminator (remove) Processor Socket Installing a Second Processor (continued) Lower Heat Sink Processor... and damage to your Online Documentation CD-ROM. Embedded SCSI A channel (external SCSI drives) 4. Boot Priority By default, the server searches for boot devices in this order: 1. PCI slot 5 7.
... 11. Embedded SCSI B channel (SCSI devices) 5. PCI slot 6 6. You can also access additional information and documentation from HP's external web site, either by connecting directly or through your HP Server tc3100 Online Documentation CD-ROM. Installing a Second Processor Terminator (remove) Processor Socket Installing a Second Processor (continued) Lower Heat Sink Processor... and damage to your Online Documentation CD-ROM. Embedded SCSI A channel (external SCSI drives) 4. Boot Priority By default, the server searches for boot devices in this order: 1. PCI slot 5 7.
hp server tc3100 internal-to-external SCSI cable kit instructions (English)
Page 1
... of the chassis to the free SCSI connector (Channel A) on the system board. External SCSI A 5. Installing the HP Server tc3100 Internal-to-external SCSI Cable Kit Installing the Optional Internal-to-external SCSI Cable The HP Server tc3100 can be configured to extend one end of the cable to remove it. 3. Route the cable straight back...
... of the chassis to the free SCSI connector (Channel A) on the system board. External SCSI A 5. Installing the HP Server tc3100 Internal-to-external SCSI Cable Kit Installing the Optional Internal-to-external SCSI Cable The HP Server tc3100 can be configured to extend one end of the cable to remove it. 3. Route the cable straight back...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 2
...furnishing, performance, or use or reliability of its software on equipment that is protected by Hewlett-Packard. Hewlett-Packard Company Network Server Division Technical Communications/MS 45SLE 10955 Tantau Avenue Cupertino, CA 95014 USA © Copyright 2001, Hewlett-Packard Company. All rights...the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels and are familiar with the HP Server tc3100. and other countries. Notice The information contained in this document is subject to change without the prior written consent of ...
...furnishing, performance, or use or reliability of its software on equipment that is protected by Hewlett-Packard. Hewlett-Packard Company Network Server Division Technical Communications/MS 45SLE 10955 Tantau Avenue Cupertino, CA 95014 USA © Copyright 2001, Hewlett-Packard Company. All rights...the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels and are familiar with the HP Server tc3100. and other countries. Notice The information contained in this document is subject to change without the prior written consent of ...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 3
... (PS/2) for Mouse and Keyboard 7 Serial Port ...7 Parallel Port ...8 USB...8 Standard Video ...9 Standard SCSI ...9 Standard LAN ...10 3 Installing and Configuring...11 Opening and Closing the HP Server tc3100 11 Opening the Upper Bezel ...12 Opening the Lower Bezel (Cold Swap Model 12 Opening the Side Panel...13 Mass Storage...14 Guidelines...14 Boot...
... (PS/2) for Mouse and Keyboard 7 Serial Port ...7 Parallel Port ...8 USB...8 Standard Video ...9 Standard SCSI ...9 Standard LAN ...10 3 Installing and Configuring...11 Opening and Closing the HP Server tc3100 11 Opening the Upper Bezel ...12 Opening the Lower Bezel (Cold Swap Model 12 Opening the Side Panel...13 Mass Storage...14 Guidelines...14 Boot...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 4
...and Mouse ...36 Uninterruptible Power Supply (UPS 37 Configuring the HP Server tc3100 ...37 HP Server Navigator CD-ROM ...37 Contents of the HP Server Navigator CD-ROM 37 Obtaining HP Server Navigator Release History 38 Accessing the HP Server Navigator CD-ROM 38 Viewing the Readme File...38 BIOS Setup...On Self Test (POST) ...45 No Error Messages Displayed...46 POST Error Messages ...46 Clearing the CMOS Configuration ...47 HP Management Solutions ...48 HP Server DiagTools ...49 HP TopTools ...50 5 Error Messages ...53 Power-On Self Test (POST) Error Codes 53 Beep Codes ...62 6 ...
...and Mouse ...36 Uninterruptible Power Supply (UPS 37 Configuring the HP Server tc3100 ...37 HP Server Navigator CD-ROM ...37 Contents of the HP Server Navigator CD-ROM 37 Obtaining HP Server Navigator Release History 38 Accessing the HP Server Navigator CD-ROM 38 Viewing the Readme File...38 BIOS Setup...On Self Test (POST) ...45 No Error Messages Displayed...46 POST Error Messages ...46 Clearing the CMOS Configuration ...47 HP Management Solutions ...48 HP Server DiagTools ...49 HP TopTools ...50 5 Error Messages ...53 Power-On Self Test (POST) Error Codes 53 Beep Codes ...62 6 ...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 7
Table 1-1 describes the LED indicators. Front Panel The front panel of the HP Server tc3100. HP Server tc3100 with Hot Swap Hard Drives 1 Figure 1-1. See Figure 1-1 and Figure 1-2. 1 Controls and Indicators This chapter describes the controls, ports, and indicators on the front and rear of the HP Server tc3100 provides the controls and indicators commonly used when operating the server. HP Server tc3100 with Cold Swap Hard Drives Figure 1-2.
Table 1-1 describes the LED indicators. Front Panel The front panel of the HP Server tc3100. HP Server tc3100 with Hot Swap Hard Drives 1 Figure 1-1. See Figure 1-1 and Figure 1-2. 1 Controls and Indicators This chapter describes the controls, ports, and indicators on the front and rear of the HP Server tc3100 provides the controls and indicators commonly used when operating the server. HP Server tc3100 with Cold Swap Hard Drives Figure 1-2.
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 17
...PCI cards are accessible from the front lower bezel. HP Server tc3100 Enclosure 11 Ensure the metal of the HP Server tc3100. Figure 3-1. The tc3100 is also available with SCSI cold swap hard drives. 3 Installing and Configuring Opening and Closing the HP Server tc3100 This section describes how to shock hazard from telephone ...open and close the front bezel, lower bezel, and side panel of the wrist strap contacts your skin. Figure 3-1 shows the HP Server tc3100 with SCSI hot swap hard drives. · The key lock, power button, and system and LAN status indicators are short-...
...PCI cards are accessible from the front lower bezel. HP Server tc3100 Enclosure 11 Ensure the metal of the HP Server tc3100. Figure 3-1. The tc3100 is also available with SCSI cold swap hard drives. 3 Installing and Configuring Opening and Closing the HP Server tc3100 This section describes how to shock hazard from telephone ...open and close the front bezel, lower bezel, and side panel of the wrist strap contacts your skin. Figure 3-1 shows the HP Server tc3100 with SCSI hot swap hard drives. · The key lock, power button, and system and LAN status indicators are short-...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 20
.... The standard SCSI cable has five 68-pin, highdensity connectors for the cold swap and hot swap drive cages. Mass Storage The HP Server tc3100 comes standard with an IDE CD-ROM and a flexible disk drive with cabling provided. Guidelines · General Guidelines o Use care when... tape backup or to connect to external mass storage devices or to 5 hard disk drives. o Channel A can hold up and out of the HP Server tc3100, occupy shelves 8 and 7 respectively. See Figure 3-5 and Figure 3-6. o The embedded dual-channel Ultra-3 SCSI controller includes connectors for the common tray...
.... The standard SCSI cable has five 68-pin, highdensity connectors for the cold swap and hot swap drive cages. Mass Storage The HP Server tc3100 comes standard with an IDE CD-ROM and a flexible disk drive with cabling provided. Guidelines · General Guidelines o Use care when... tape backup or to connect to external mass storage devices or to 5 hard disk drives. o Channel A can hold up and out of the HP Server tc3100, occupy shelves 8 and 7 respectively. See Figure 3-5 and Figure 3-6. o The embedded dual-channel Ultra-3 SCSI controller includes connectors for the common tray...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 21
... hot swap hard drives starting from the bottom drive cage in the boot order. If there are all empty slots in the HP Server tc3100. On each empty disk location. This is especially important if you are automatically assigned SCSI addresses by highest to lowest priority. Channel...the cold swap or hot swap drive cage have a unique address. If there are installing a board that requires a higher priority in the HP Server tc3100. The server's boot order should be considered when selecting a boot device. Embedded SCSI B channel (SCSI Devices) 5. o The cold swap SCSI back...
... hot swap hard drives starting from the bottom drive cage in the boot order. If there are all empty slots in the HP Server tc3100. On each empty disk location. This is especially important if you are automatically assigned SCSI addresses by highest to lowest priority. Channel...the cold swap or hot swap drive cage have a unique address. If there are installing a board that requires a higher priority in the HP Server tc3100. The server's boot order should be considered when selecting a boot device. Embedded SCSI B channel (SCSI Devices) 5. o The cold swap SCSI back...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 22
...internal backup tape. Installed Mass Storage Devices Table 3-1 lists the number and types of mass storage devices that may be changed using the server's (BIOS) Setup Utility and the SCSI Select Utility. See "BIOS Setup Utility" later in this chapter. they are only enough ...remove connectors carefully, and avoid displacing any of up to an accessory board, see "Installing a Disk Array Controller Board" later in the HP Server tc3100. however, there are ESD sensitive. Embedded LAN For information about booting off of the wrist strap contacts your skin. The flexible disk, CD...
...internal backup tape. Installed Mass Storage Devices Table 3-1 lists the number and types of mass storage devices that may be changed using the server's (BIOS) Setup Utility and the SCSI Select Utility. See "BIOS Setup Utility" later in this chapter. they are only enough ...remove connectors carefully, and avoid displacing any of up to an accessory board, see "Installing a Disk Array Controller Board" later in the HP Server tc3100. however, there are ESD sensitive. Embedded LAN For information about booting off of the wrist strap contacts your skin. The flexible disk, CD...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 25
...external mass storage devices to an external SCSI connector. Figure 3-8. Chapter 3 Installing and Configuring Figure 3-7. It requires a second SCSI cable, HP Server tc3100 Internal/External SCSI Cable Kit, PN: P1774A. 1. Removing IO Locking Bracket 19 This allows you and slide out. See Figure 3-8. a.... Installing Additional Cabling Installing Optional Internal to External SCSI Cable The HP Server tc3100 can be configured to extend one of its SCSI channels (channel A) to the second channel of the server's embedded SCSI controller.
...external mass storage devices to an external SCSI connector. Figure 3-8. Chapter 3 Installing and Configuring Figure 3-7. It requires a second SCSI cable, HP Server tc3100 Internal/External SCSI Cable Kit, PN: P1774A. 1. Removing IO Locking Bracket 19 This allows you and slide out. See Figure 3-8. a.... Installing Additional Cabling Installing Optional Internal to External SCSI Cable The HP Server tc3100 can be configured to extend one of its SCSI channels (channel A) to the second channel of the server's embedded SCSI controller.
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 29
... Figure 3-12. Do not stack drives. The EDO DIMMs and PC 100 SDRAM DIMMs from earlier HP Server models will fit into the DIMM slots in an electrostatic protected container. Ensure you . 3. Memory Modules The HP Server's main memory is provided with at least one 128 MB DIMM. NOTE Use only PC 133 (133... to stop spinning to ensure the drive heads are not supported. 23 Wait about an inch to disconnect from HewlettPackard. Place the drive in the HP Server tc3100, but the EDO DIMMs and PC 100 SDRAM will not function properly and are parked prior to 4 GB (1 GB x 4) of the drive, while you ...
... Figure 3-12. Do not stack drives. The EDO DIMMs and PC 100 SDRAM DIMMs from earlier HP Server models will fit into the DIMM slots in an electrostatic protected container. Ensure you . 3. Memory Modules The HP Server's main memory is provided with at least one 128 MB DIMM. NOTE Use only PC 133 (133... to stop spinning to ensure the drive heads are not supported. 23 Wait about an inch to disconnect from HewlettPackard. Place the drive in the HP Server tc3100, but the EDO DIMMs and PC 100 SDRAM will not function properly and are parked prior to 4 GB (1 GB x 4) of the drive, while you ...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 30
...4 DIMM slots). · DIMM sizes may be mixed on the HP Server Online Documentation CD-ROM · HP Customer Service CAUTION Use an anti static service kit (3M 8501/8502/8503 or equivalent). Guidelines · The HP Server tc3100 uses only PC 133 (133 MHz) buffered, ECC, SDRAM DIMMs..., which are electrically different from the HP Server to install the additional DIMM memory. 4. Chapter 3 Installing and Configuring To ensure you...
...4 DIMM slots). · DIMM sizes may be mixed on the HP Server Online Documentation CD-ROM · HP Customer Service CAUTION Use an anti static service kit (3M 8501/8502/8503 or equivalent). Guidelines · The HP Server tc3100 uses only PC 133 (133 MHz) buffered, ECC, SDRAM DIMMs..., which are electrically different from the HP Server to install the additional DIMM memory. 4. Chapter 3 Installing and Configuring To ensure you...
hp server tc3100 operation and maintenance guide (English, v1.1)
Page 32
...displays an error message or appears blank and sounds beep codes. Removing DIMMs You may get a blank screen. NOTE If you power up the server and return it to the system board and press the DIMM firmly and evenly into the slot until the retaining latches close , the DIMM is... you may need to remove a DIMM module to downsize your memory configuration or to bend or break the DIMM connector during installation. Processors The HP Server tc3100 ships with both hands and use even pressure so as not to replace a defective DIMM. Both primary and secondary processor sockets are embedded in ...
...displays an error message or appears blank and sounds beep codes. Removing DIMMs You may get a blank screen. NOTE If you power up the server and return it to the system board and press the DIMM firmly and evenly into the slot until the retaining latches close , the DIMM is... you may need to remove a DIMM module to downsize your memory configuration or to bend or break the DIMM connector during installation. Processors The HP Server tc3100 ships with both hands and use even pressure so as not to replace a defective DIMM. Both primary and secondary processor sockets are embedded in ...