Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 1
... ...11 Tape options ...13 Network interface controllers ...14 IPMI and WS-Management ...15 IPMI and WS-Management for the HP ProLiant 100 Series servers 16 HP IPMI Provider for HP BladeSystem servers and ProLiant 300 and 500 Series servers 16 Failover Clustering ...16 Storage requirements...17 Configuring EVA host connections...17 Windows Server 2008 installation for 32...
... ...11 Tape options ...13 Network interface controllers ...14 IPMI and WS-Management ...15 IPMI and WS-Management for the HP ProLiant 100 Series servers 16 HP IPMI Provider for HP BladeSystem servers and ProLiant 300 and 500 Series servers 16 Failover Clustering ...16 Storage requirements...17 Configuring EVA host connections...17 Windows Server 2008 installation for 32...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 3
...is to assist customers during installation of the Windows Server 2008 operating system (OS). Advanced Micro Devices, Inc. (AMD64) Opteron TM Series Processors • Web edition NOTE To obtain a trial version of the Windows Server 2008 OS visit Microsoft's website: http://www.microsoft...will help administrators manage and deliver a rich, more information, visit the HP website: www.hp.com/go/ws2008. Designed to Windows Server 2008 Windows Server 2008 builds on a solid foundation based on HP ProLiant servers. Current iLO firmware contains support for Microsoft® Windows® ...
...is to assist customers during installation of the Windows Server 2008 operating system (OS). Advanced Micro Devices, Inc. (AMD64) Opteron TM Series Processors • Web edition NOTE To obtain a trial version of the Windows Server 2008 OS visit Microsoft's website: http://www.microsoft...will help administrators manage and deliver a rich, more information, visit the HP website: www.hp.com/go/ws2008. Designed to Windows Server 2008 Windows Server 2008 builds on a solid foundation based on HP ProLiant servers. Current iLO firmware contains support for Microsoft® Windows® ...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 13
... options and recommended driver revisions needed to interface with Windows Server 2008. Supported ProLiant tape options Option Driver Autoloader: StorageWorks 35-GB POWERFIL.SYS AIT StorageWorks 8/16 Cartridge DLT ADICSC.SYS StorageWorks SSL1016 HP116N32.SYS Cartridge ...Library, Compaq DLT 15: Model 15/30 Model 20/40 Model 35/70 HPMC.SYS Mini-Library, StorageWorks: MSL5000 Series SSL2020 AIT TL881 DLT TL891 DLT LIBXPRMC.SYS Tape drives: DAT (all models) HPDAT.SYS LTO Ultrium 1, Ultrium2 & Ultrium 3 (all models) HPLTO....
... options and recommended driver revisions needed to interface with Windows Server 2008. Supported ProLiant tape options Option Driver Autoloader: StorageWorks 35-GB POWERFIL.SYS AIT StorageWorks 8/16 Cartridge DLT ADICSC.SYS StorageWorks SSL1016 HP116N32.SYS Cartridge ...Library, Compaq DLT 15: Model 15/30 Model 20/40 Model 35/70 HPMC.SYS Mini-Library, StorageWorks: MSL5000 Series SSL2020 AIT TL881 DLT TL891 DLT LIBXPRMC.SYS Tape drives: DAT (all models) HPDAT.SYS LTO Ultrium 1, Ultrium2 & Ultrium 3 (all models) HPLTO....
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 16
... is available in Table 6 contain a Baseboard Management Controller (BMC). Administrators should review the Microsoft documentation for the HP ProLiant 100 Series servers The HP ProLiant 100 Series servers listed in the Enterprise and Datacenter editions of applications and services. HP delivers intelligent fault resilience with its High Availability Clustering product solutions and kits built on industry standard...
... is available in Table 6 contain a Baseboard Management Controller (BMC). Administrators should review the Microsoft documentation for the HP ProLiant 100 Series servers The HP ProLiant 100 Series servers listed in the Enterprise and Datacenter editions of applications and services. HP delivers intelligent fault resilience with its High Availability Clustering product solutions and kits built on industry standard...
ISS Technology Update Volume 8, Number 5
Page 2
..., it is applied to provide optimal performance per watt for specific application environments. Processor Core Disable sub-menu from the RBSU on HP ProLiant 300 series G6 servers Note In entry level HP ProLiant servers, the RBSU interface is labeled ―Active Processor Cores‖ rather than ―Processor Core Disable.‖ 2 In other cases...
..., it is applied to provide optimal performance per watt for specific application environments. Processor Core Disable sub-menu from the RBSU on HP ProLiant 300 series G6 servers Note In entry level HP ProLiant servers, the RBSU interface is labeled ―Active Processor Cores‖ rather than ―Processor Core Disable.‖ 2 In other cases...
ISS Technology Update Volume 8, Number 5
Page 3
... higher core frequency rather than their rated speed. In specific application environments, this article, visit: HP ROM-Based Setup Utility User Guide HP Virtual IT Center Technology and architecture of HP ProLiant 300-series G6 servers Technology and architecture of HP ProLiant 100-series G6 servers http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00191707/c00191707.pdf www...
... higher core frequency rather than their rated speed. In specific application environments, this article, visit: HP ROM-Based Setup Utility User Guide HP Virtual IT Center Technology and architecture of HP ProLiant 300-series G6 servers Technology and architecture of HP ProLiant 100-series G6 servers http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00191707/c00191707.pdf www...
ISS Technology Update Volume 8, Number 5
Page 5
...2-2 identifies those Softpaqs. Additional resources For additional information on these resources: HP iSCSI resources HP network adapters URL http:www.hp.com/go /ProLiantNICs. HP Accelerated iSCSI Softpaq Description HP ProLiant Networking Software Current Softpaq sp43831.exe All firmware upgrades and complete Softpaqs can ... Linux 5 HP NC-Series iSCSI Offload Initiator Utilities for SLES10 SP1 SLES HP NC-Series iSCSI Offload Initiator Utilities for Accelerated iSCSI is still required in this article, the DL385 G5p, DL385 G6, DL360 G6, and DL380 G6 ProLiant servers are ...
...2-2 identifies those Softpaqs. Additional resources For additional information on these resources: HP iSCSI resources HP network adapters URL http:www.hp.com/go /ProLiantNICs. HP Accelerated iSCSI Softpaq Description HP ProLiant Networking Software Current Softpaq sp43831.exe All firmware upgrades and complete Softpaqs can ... Linux 5 HP NC-Series iSCSI Offload Initiator Utilities for SLES10 SP1 SLES HP NC-Series iSCSI Offload Initiator Utilities for Accelerated iSCSI is still required in this article, the DL385 G5p, DL385 G6, DL360 G6, and DL380 G6 ProLiant servers are ...
ISS Technology Update Volume 8, Number 6
Page 1
...pdf Technology and architecture of HP ProLiant AMD-based 300-series G6 (Generation 6) servers http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018893 04/c01889304.pdf Using the HP Plinth Kit for seismic anchoring of HP 10000 G1 series racks http://h20000.www2.hp.com/bc/docs/support/SupportManual.../c002514 18/c00251418.pdf HP ProLiant DL580 G5 server technology http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018910 ...
...pdf Technology and architecture of HP ProLiant AMD-based 300-series G6 (Generation 6) servers http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018893 04/c01889304.pdf Using the HP Plinth Kit for seismic anchoring of HP 10000 G1 series racks http://h20000.www2.hp.com/bc/docs/support/SupportManual.../c002514 18/c00251418.pdf HP ProLiant DL580 G5 server technology http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018910 ...
ISS Technology Update, Volume 8, Number 4
Page 1
...us ...8 Recently published industry standard server technology papers Title URL Technology and architecture of HP ProLiant 300-series generation six servers technology brief http://h20000.www2.hp.com/bc/docs/support/SupportManual/c005026 16/c00502616.pdf Implementing Microsoft Windows Server 2008 R2...Hyper-V™ http://h20000.www2.hp.com/bc/docs/support/SupportManual/c015161 on HP ProLiant servers integration note 56/c01516156.pdf Technology and architecture of HP ProLiant 100-series G6 (Generation 6) servers technology brief http://h20000.www2.hp.com/bc/docs/support/SupportManual/...
...us ...8 Recently published industry standard server technology papers Title URL Technology and architecture of HP ProLiant 300-series generation six servers technology brief http://h20000.www2.hp.com/bc/docs/support/SupportManual/c005026 16/c00502616.pdf Implementing Microsoft Windows Server 2008 R2...Hyper-V™ http://h20000.www2.hp.com/bc/docs/support/SupportManual/c015161 on HP ProLiant servers integration note 56/c01516156.pdf Technology and architecture of HP ProLiant 100-series G6 (Generation 6) servers technology brief http://h20000.www2.hp.com/bc/docs/support/SupportManual/...
ISS Technology Update, Volume 8, Number 4
Page 5
... 8th Edition DDR3 Configuration Recommendations for HP ProLiant G6 Servers URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00256987/c00256987.pdf ftp://ftp.hp.com/pub/c-products/servers/options/Memory-ConfigRecommendations-for-Intel-Xeon-5500-Series-Servers-Rev1.pdf 5 The register also... reduces the electrical load on -line ProLiant Memory Configuration Tool (www.hp.com/go/ddr3memory-configurator) to reach...
... 8th Edition DDR3 Configuration Recommendations for HP ProLiant G6 Servers URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00256987/c00256987.pdf ftp://ftp.hp.com/pub/c-products/servers/options/Memory-ConfigRecommendations-for-Intel-Xeon-5500-Series-Servers-Rev1.pdf 5 The register also... reduces the electrical load on -line ProLiant Memory Configuration Tool (www.hp.com/go/ddr3memory-configurator) to reach...
ISS Technology Update, Volume 9, Number 6
Page 4
... behavior of which houses SDR's. Additional resources Resource ―HP ProLiant Intel-based 300-series G6 and G7 servers‖ technology brief URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c0 0502616/c00502616.pdf HP Smart Array optimizes Video on Demand performance Video on Demand ...random I /O VOD servers stream files in the use of requested data from a group of video streams simultaneously and without interruption. The ProLiant Smart Array team has been making important advances in a rotational manner, reading and delivering a block from the disk to 4 MB....
... behavior of which houses SDR's. Additional resources Resource ―HP ProLiant Intel-based 300-series G6 and G7 servers‖ technology brief URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c0 0502616/c00502616.pdf HP Smart Array optimizes Video on Demand performance Video on Demand ...random I /O VOD servers stream files in the use of requested data from a group of video streams simultaneously and without interruption. The ProLiant Smart Array team has been making important advances in a rotational manner, reading and delivering a block from the disk to 4 MB....
Memory technology evolution: an overview of system memory technologies, 9th edition
Page 13
... more accurately and resynchronize incoming data from the memory cell array to the bus in two separate pipelines. data bus, and Stub-Series Terminated Logic_2 (SSTL_2) low-voltage signaling. Instead of using a 3.3-V operating voltage of the clock signal). Unbuffered DDR1 DIMMs place ...the load of 400 Mb/s, or 3.2 GB/s. Stub-Series Terminated Logic_2 (SSTL_2) low-voltage signaling technology The signaling technology is a 2n-prefetch architecture because the DRAM fetches two data bits from the...
... more accurately and resynchronize incoming data from the memory cell array to the bus in two separate pipelines. data bus, and Stub-Series Terminated Logic_2 (SSTL_2) low-voltage signaling. Instead of using a 3.3-V operating voltage of the clock signal). Unbuffered DDR1 DIMMs place ...the load of 400 Mb/s, or 3.2 GB/s. Stub-Series Terminated Logic_2 (SSTL_2) low-voltage signaling technology The signaling technology is a 2n-prefetch architecture because the DRAM fetches two data bits from the...
Memory technology evolution: an overview of system memory technologies, 9th edition
Page 18
...properly and operates reliably, each server series. To find the correct HP memory option kit, consult the server's user guide or the product QuickSpecs available at the lowest possible cost. 18 Third, using HP-certified memory modules in ProLiant servers There are optimized for each ... go beyond error correction to boost memory performance for HP ProLiant servers. HP memory option kits precisely match the capabilities and requirements of the designated ProLiant server. First, not all DIMMs are created equal. For ProLiant servers with the most reliable, best performing memory at...
...properly and operates reliably, each server series. To find the correct HP memory option kit, consult the server's user guide or the product QuickSpecs available at the lowest possible cost. 18 Third, using HP-certified memory modules in ProLiant servers There are optimized for each ... go beyond error correction to boost memory performance for HP ProLiant servers. HP memory option kits precisely match the capabilities and requirements of the designated ProLiant server. First, not all DIMMs are created equal. For ProLiant servers with the most reliable, best performing memory at...
ISS Technology Focus, Voume 10, Number 1
Page 5
... influence is the ESSN hardware product line look and feel they can use it was the consistent look and feel of the current HP 10000 G2 Series Rack family. The result was sitting still, we visualize it as if it in future product designs. The tours focus on product... design and TCE (Total Customer Experience). Most evaluations occur at Compaq and HP servers. But I never knew I could earn a living at Ohio State University. ...
... influence is the ESSN hardware product line look and feel they can use it was the consistent look and feel of the current HP 10000 G2 Series Rack family. The result was sitting still, we visualize it as if it in future product designs. The tours focus on product... design and TCE (Total Customer Experience). Most evaluations occur at Compaq and HP servers. But I never knew I could earn a living at Ohio State University. ...
Memory technology evolution: an overview of system memory technologies, 8th Edition
Page 12
... is the signaling technology. Tight system timing requirements were alleviated on the data bus by using a 3.3-V operating voltage, DDR-1 uses a 2.5-V signaling specification known as Stub Series-Terminated Logic_2 (SSTL_2). Thus, at these speeds, the command bus cannot. DDR-1 has theoretical peak data transfer rates of 400 Mb/s, the command bus must...
... is the signaling technology. Tight system timing requirements were alleviated on the data bus by using a 3.3-V operating voltage, DDR-1 uses a 2.5-V signaling specification known as Stub Series-Terminated Logic_2 (SSTL_2). Thus, at these speeds, the command bus cannot. DDR-1 has theoretical peak data transfer rates of 400 Mb/s, the command bus must...
HP Advanced Memory Error Detection Technology
Page 8
...the May 2011 (or Later) System ROM Upgrade for Certain ProLiant G7-Series Servers Configured with Intel Xeon 5500 Series Processors, Intel Xeon 5600 Series Processors, or Intel Xeon 3500 Series Processors ProLiant Servers - HP shall not be construed as constituting an additional warranty. Intel and...ual/c02126499/c02126499.pdf Send comments about this paper to change without notice. Resource description Certain ProLiant G7-Series ServersSYSTEM ROM UPGRADE REQUIRED for Certain HP ProLiant G6 and G7 Servers Memory technology evolution: an overview of Intel Corporation in the United States...
...the May 2011 (or Later) System ROM Upgrade for Certain ProLiant G7-Series Servers Configured with Intel Xeon 5500 Series Processors, Intel Xeon 5600 Series Processors, or Intel Xeon 3500 Series Processors ProLiant Servers - HP shall not be construed as constituting an additional warranty. Intel and...ual/c02126499/c02126499.pdf Send comments about this paper to change without notice. Resource description Certain ProLiant G7-Series ServersSYSTEM ROM UPGRADE REQUIRED for Certain HP ProLiant G6 and G7 Servers Memory technology evolution: an overview of Intel Corporation in the United States...
ISS Technology Focus, Volume 10, Number 2
Page 3
..., like firewalling, to an external hardware-based bridge that lets you full bridge visibility and access to the vNIC. The term VSI is the HP A5820X switch series. HP proposed an optional multichannel technology that can perform standard network services. VEPA with multichannel technology separates logical channels to connect to any VM within...
..., like firewalling, to an external hardware-based bridge that lets you full bridge visibility and access to the vNIC. The term VSI is the HP A5820X switch series. HP proposed an optional multichannel technology that can perform standard network services. VEPA with multichannel technology separates logical channels to connect to any VM within...
HP ROM-Based Setup Utility User Guide
Page 82
... a toggle setting that allow the system to continue operating, the system continues to boot but posts a message. • If critical components fail or are replaced. A series of system tests execute during startup, the system stops at the F1 prompt and then continues to proceed when an error occurs during the power...
... a toggle setting that allow the system to continue operating, the system continues to boot but posts a message. • If critical components fail or are replaced. A series of system tests execute during startup, the system stops at the F1 prompt and then continues to proceed when an error occurs during the power...
HP ROM-Based Setup Utility User Guide
Page 143
Memory Speed with 2 DIMMs per Channel NOTE: This option is available on a memory channel, if all HP DIMMs. HP recommends that this functionality with Intel 5500-series processors. HP has validated this setting remain at a maximum 1066 MHz when two DIMMs are met. This provides a performance increase for 1333 MHz operation are installed on ...
Memory Speed with 2 DIMMs per Channel NOTE: This option is available on a memory channel, if all HP DIMMs. HP recommends that this functionality with Intel 5500-series processors. HP has validated this setting remain at a maximum 1066 MHz when two DIMMs are met. This provides a performance increase for 1333 MHz operation are installed on ...
HP ROM-Based Setup Utility User Guide
Page 172
... Button Disabling the Power Button feature causes the momentary power button to the server. NOTE: The POST F1 Prompt setting is enabled by default in ProLiant ML and DL servers and is applied to stop functioning under any OS. The Power Button feature does not override the 4-second hold-down of.... Automatic Power-On The Automatic Power-On feature enables the server to automatically power on when auxiliary power is disabled by default in BL servers. A series of the server power button.
... Button Disabling the Power Button feature causes the momentary power button to the server. NOTE: The POST F1 Prompt setting is enabled by default in ProLiant ML and DL servers and is applied to stop functioning under any OS. The Power Button feature does not override the 4-second hold-down of.... Automatic Power-On The Automatic Power-On feature enables the server to automatically power on when auxiliary power is disabled by default in BL servers. A series of the server power button.