Error Prevention Guide
Page 5
...aware of downtime experienced due to memory or PCI card upgrades. Anticipate the utilization rate and distribute servers based on enterprise class servers, high availability features such as Hot-Pluggable RAID memory functionality and Hot-Plug PCI slots effectively minimize the amount of the latest ...software updates for the operating system and applications, and update software for server BIOS, drivers, and agents. • Be sure that you allow enough time...
...aware of downtime experienced due to memory or PCI card upgrades. Anticipate the utilization rate and distribute servers based on enterprise class servers, high availability features such as Hot-Pluggable RAID memory functionality and Hot-Plug PCI slots effectively minimize the amount of the latest ...software updates for the operating system and applications, and update software for server BIOS, drivers, and agents. • Be sure that you allow enough time...
HP Insight Management Agents architecture for Windows servers
Page 5
... collected Server hardware information (Product ID, serial #, board revisions) CPU configuration Memory installed PCI devices and system slots Sensor information (fans, temperature, power supplies and redundancy) Critical events (hardware errors) Management processor information BladeSystem enclosure information Source SM BIOS SM BIOS SM BIOS and System Management driver SM BIOS, Windows OS System Management driver HP...
... collected Server hardware information (Product ID, serial #, board revisions) CPU configuration Memory installed PCI devices and system slots Sensor information (fans, temperature, power supplies and redundancy) Critical events (hardware errors) Management processor information BladeSystem enclosure information Source SM BIOS SM BIOS SM BIOS and System Management driver SM BIOS, Windows OS System Management driver HP...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 39
...Utility (RBSU). • OS releases affected-All • Servers affected-All supported ProLiant servers • Description-Disabling PCI devices in RBSU might fail, or Solaris will not deploy on an HP ProLiant BL260c G5 or BL280c G6 blade server when the SATA controller is configured in Solaris 10 10/08.... • Workaround-When prompted during the Solaris installation, select non-networked. This issue is not reported if the extra drivers are added during network configuration or Solaris is unable to configure network interfaces after rebooting. After the installation is fixed with ...
...Utility (RBSU). • OS releases affected-All • Servers affected-All supported ProLiant servers • Description-Disabling PCI devices in RBSU might fail, or Solaris will not deploy on an HP ProLiant BL260c G5 or BL280c G6 blade server when the SATA controller is configured in Solaris 10 10/08.... • Workaround-When prompted during the Solaris installation, select non-networked. This issue is not reported if the extra drivers are added during network configuration or Solaris is unable to configure network interfaces after rebooting. After the installation is fixed with ...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 41
...; OS releases affected-Solaris 10 8/07, 5/08, 10/08 • Servers affected-HP ProLiant BL685c, BL685c G5, BL680c, BL480c, BL260c G5 • Description-The Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later successfully installs but fails to the following for... -r 3. For NC326i: "dev:///pci@0,0/pci8086,65e2@2/pci1166,103@0/pci103c,703c@4" "dev:/// pci@0,0/pci8086,65e2@2/pci1166,103@0/pci103c,703c@4,1" For NC325m: dev:////pci@0,0/pci8086,25e3@3/pci111d,801c@0/pci111d,801c@0/pci11 66,103@0/pci103c,170c@4,1 dev:////pci@0,0/pci8086,25e2@2/pci8086,3500@0/pci8086,3514@1/pci11...
...; OS releases affected-Solaris 10 8/07, 5/08, 10/08 • Servers affected-HP ProLiant BL685c, BL685c G5, BL680c, BL480c, BL260c G5 • Description-The Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later successfully installs but fails to the following for... -r 3. For NC326i: "dev:///pci@0,0/pci8086,65e2@2/pci1166,103@0/pci103c,703c@4" "dev:/// pci@0,0/pci8086,65e2@2/pci1166,103@0/pci103c,703c@4,1" For NC325m: dev:////pci@0,0/pci8086,25e3@3/pci111d,801c@0/pci111d,801c@0/pci11 66,103@0/pci103c,170c@4,1 dev:////pci@0,0/pci8086,25e2@2/pci8086,3500@0/pci8086,3514@1/pci11...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 52
...about this guide, 6 additional drivers, 13 AMD memory scrubber, 40 applicable OS versions, 6 applicable servers, 6 B basic installation ... succeeds but no network availability after reboot, 47 installation succeeds but server fails to boot, 47 installation terminates prematurely, 46 JumpStart reverts to...17 custom bootable ISO image creation prerequisites, 33 procedure, 33 D deploying ProLiant servers, 12 additional drivers, 13 deployment resource kit, 15 flash archives, 15 iLO virtual media, ... 30 install server preparation, 19 JumpStart preparation, 23 miniroot preparation, 21 overview, 19 Rapid ...
...about this guide, 6 additional drivers, 13 AMD memory scrubber, 40 applicable OS versions, 6 applicable servers, 6 B basic installation ... succeeds but no network availability after reboot, 47 installation succeeds but server fails to boot, 47 installation terminates prematurely, 46 JumpStart reverts to...17 custom bootable ISO image creation prerequisites, 33 procedure, 33 D deploying ProLiant servers, 12 additional drivers, 13 deployment resource kit, 15 flash archives, 15 iLO virtual media, ... 30 install server preparation, 19 JumpStart preparation, 23 miniroot preparation, 21 overview, 19 Rapid ...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 53
DiskSuite, 34 drivers additional ProLiant, 13 E Embedded Ethernet not configured, 42 Enabling ... documentation, 48 HP documentation, 48 Intel documentation, 48 overview, 48 Sun Microsystems documentation, 48 HP ProLiant Essentials Rapid Deployment Pack, 14 I iLO boot hang, 40 iLO virtual media, 14 install server, 12 install server preparation prerequisites, ... Deployment Pack, 24 JumpStart reverts to interactive configuration, 46 JumpStart server, 12 K kernel debugger, 44 known issues AMD memory scrubber, 40 disabled PCI devices, 39 iLO boot hang, 40 network configuration fails during interactive...
DiskSuite, 34 drivers additional ProLiant, 13 E Embedded Ethernet not configured, 42 Enabling ... documentation, 48 HP documentation, 48 Intel documentation, 48 overview, 48 Sun Microsystems documentation, 48 HP ProLiant Essentials Rapid Deployment Pack, 14 I iLO boot hang, 40 iLO virtual media, 14 install server, 12 install server preparation prerequisites, ... Deployment Pack, 24 JumpStart reverts to interactive configuration, 46 JumpStart server, 12 K kernel debugger, 44 known issues AMD memory scrubber, 40 disabled PCI devices, 39 iLO boot hang, 40 network configuration fails during interactive...
HP Insight Management WBEM Providers for Windows Server 2003 and Windows Server 2008 User Guide
Page 24
... Providers collect data from sources such as drivers and system firmware to populate the data model. By using scripting hosts or writing directly to distinguish between Microsoft®-provided components, HP components, and ProLiant WMI components. The Insight Providers implement the..., providing automated administrative tasks. Insight Providers architecture Architecture overview The following instrumentation: • Server providers: o Processor information and indications o Memory information and indications o PCI devices and system slots information Insight Providers architecture 24
... Providers collect data from sources such as drivers and system firmware to populate the data model. By using scripting hosts or writing directly to distinguish between Microsoft®-provided components, HP components, and ProLiant WMI components. The Insight Providers implement the..., providing automated administrative tasks. Insight Providers architecture Architecture overview The following instrumentation: • Server providers: o Processor information and indications o Memory information and indications o PCI devices and system slots information Insight Providers architecture 24
HP local I/O technology for ProLiant and BladeSystem servers
Page 6
...drivers). X x4 X8 x4 x16 x8 64/66 P CIe 100 133 P CIe 266 P CIe P CIe P CIe 2.0 P CIe P CIe 2.0 Backward compatibility PCI Express is required to take advantage of new and extended PCI Express architecture features. X P CI- The PCI Express configuration uses standard PCI plug and play and PCI Hot Plug mechanisms. PCI...illustrates the bandwidths of PCI, PCI-X, and PCI Express, which will provide sufficient I/O bandwidth migration for desktop graphics and server I/O 6 X x2 P CI- Form factors The PCI Express specification includes a range of PCI, PCI-X, and PCI Express (PCIe) ...
...drivers). X x4 X8 x4 x16 x8 64/66 P CIe 100 133 P CIe 266 P CIe P CIe P CIe 2.0 P CIe P CIe 2.0 Backward compatibility PCI Express is required to take advantage of new and extended PCI Express architecture features. X P CI- The PCI Express configuration uses standard PCI plug and play and PCI Hot Plug mechanisms. PCI...illustrates the bandwidths of PCI, PCI-X, and PCI Express, which will provide sufficient I/O bandwidth migration for desktop graphics and server I/O 6 X x2 P CI- Form factors The PCI Express specification includes a range of PCI, PCI-X, and PCI Express (PCIe) ...
HP ProLiant DL365 Generation 5 Server User Guide
Page 14
The server has detected a critical temperature level. One or more fans have failed or are not being met in another bank. The health driver has detected a cautionary temperature level. A redundant fan has failed. The PCI riser board assembly is an unsupported type, but valid memory exists in the system. The...another bank. No valid or usable memory is an unsupported type, and no valid memory exists in one or more of the fan modules. HP Systems Insight Display LED and color PPM failure (amber) DIMM failure, slot X (amber) Internal health LED color Red Red Amber DIMM failure,...
The server has detected a critical temperature level. One or more fans have failed or are not being met in another bank. The health driver has detected a cautionary temperature level. A redundant fan has failed. The PCI riser board assembly is an unsupported type, but valid memory exists in the system. The...another bank. No valid or usable memory is an unsupported type, and no valid memory exists in one or more of the fan modules. HP Systems Insight Display LED and color PPM failure (amber) DIMM failure, slot X (amber) Internal health LED color Red Red Amber DIMM failure,...
HP ProLiant DL365 Generation 5 Server User Guide
Page 117
...driver 13, 70 HP Insight Diagnostics 74 HP ProLiant Essentials Foundation Pack 72 I identification number 95 iLO 2 (Integrated Lights-Out 2) 9, 71 iLO 2 activity LED 10 iLO 2 link LED 10 IML (Integrated Management Log) 74 Important Safety Information document 78 Insight Diagnostics 74 installation services 24 installation, server...installation 28, 32 ORCA (Option ROM Configuration for Arrays) 69 OS boot problems flowchart 89 P PCI array controllers, cabling 62 PCI riser board assembly 22 PCI-X riser board 47 POST error messages 93 POST problems flowchart 88 power cord 79, 100 power distribution...
...driver 13, 70 HP Insight Diagnostics 74 HP ProLiant Essentials Foundation Pack 72 I identification number 95 iLO 2 (Integrated Lights-Out 2) 9, 71 iLO 2 activity LED 10 iLO 2 link LED 10 IML (Integrated Management Log) 74 Important Safety Information document 78 Insight Diagnostics 74 installation services 24 installation, server...installation 28, 32 ORCA (Option ROM Configuration for Arrays) 69 OS boot problems flowchart 89 P PCI array controllers, cabling 62 PCI riser board assembly 22 PCI-X riser board 47 POST error messages 93 POST problems flowchart 88 power cord 79, 100 power distribution...