Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 75
... Data: • sysName • cpqHoTrapFlags Storage agents 75 The Storage Agent has detected a change in the power supply status of a SAS or SATA physical drive. Log Message: The fault tolerant power supply in the %6 %7 storage system connected to %5 of the controller in...Storage System power supply status changed to [cpqSsBoxFltTolPwrSupplyStatus]." NT Event ID: 1221 (Hex)0x843504c5 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: SAS/SATA Physical Drive Status Change. User Action: If the power supply status is indicated in %4, %5 with serial number "%6", has a new status...
... Data: • sysName • cpqHoTrapFlags Storage agents 75 The Storage Agent has detected a change in the power supply status of a SAS or SATA physical drive. Log Message: The fault tolerant power supply in the %6 %7 storage system connected to %5 of the controller in...Storage System power supply status changed to [cpqSsBoxFltTolPwrSupplyStatus]." NT Event ID: 1221 (Hex)0x843504c5 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: SAS/SATA Physical Drive Status Change. User Action: If the power supply status is indicated in %4, %5 with serial number "%6", has a new status...
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 76
...1281 (Hex)0x84350501 (Service Event) Log Severity: Warning (2) Log Message: Could not read from the registry subkey. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 1282 (Hex)0x84350502 (Service Event) Log Severity: Warning (2) Log Message:... SNMP Trap: cpqSasLogDrvStatusChange - 5023 in the cpqSasLogDrvStatus variable. Rebooting the server may correct this error. NT Event ID: 1222 (Hex)0x843504c6 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: SAS/SATA Logical Drive Status Change. • cpqSasHbaHwLocation • cpqSasPhyDrvLocationString ...
...1281 (Hex)0x84350501 (Service Event) Log Severity: Warning (2) Log Message: Could not read from the registry subkey. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 1282 (Hex)0x84350502 (Service Event) Log Severity: Warning (2) Log Message:... SNMP Trap: cpqSasLogDrvStatusChange - 5023 in the cpqSasLogDrvStatus variable. Rebooting the server may correct this error. NT Event ID: 1222 (Hex)0x843504c6 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: SAS/SATA Logical Drive Status Change. • cpqSasHbaHwLocation • cpqSasPhyDrvLocationString ...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 71
MP Management Pack NIC network interface controller PCI peripheral component interface RAID redundant array of inexpensive (or independent) disks SAS serial attached SCSI SATA serial ATA SCSI small computer system interface SIM Systems Insight Manager SMH System Management Homepage SNMP Simple Network Management Protocol SP1 Service Pack 1 SQL structured query language UPS uninterruptible power system WMI Windows Management Instrumentation Acronyms and abbreviations 71
MP Management Pack NIC network interface controller PCI peripheral component interface RAID redundant array of inexpensive (or independent) disks SAS serial attached SCSI SATA serial ATA SCSI small computer system interface SIM Systems Insight Manager SMH System Management Homepage SNMP Simple Network Management Protocol SP1 Service Pack 1 SQL structured query language UPS uninterruptible power system WMI Windows Management Instrumentation Acronyms and abbreviations 71
10 Gigabit Ethernet technology for industry-standard servers
Page 2
...network architecture Current network architecture uses separate, heterogeneous networks to this standard. This is increasing bandwidth requirements per physical server grows. Although some companies may combine general IP traffic with ever more virtual machines are essential. Practically all business ... to reduce cabling High-bandwidth applications such as the network architecture of Electrical and Electronics Engineers Standards Association (IEEE-SA) in 2006 with virtual LANs (VLANs). 2 Why 10GbE technology is important Using faster multi-core processors is ...
...network architecture Current network architecture uses separate, heterogeneous networks to this standard. This is increasing bandwidth requirements per physical server grows. Although some companies may combine general IP traffic with ever more virtual machines are essential. Practically all business ... to reduce cabling High-bandwidth applications such as the network architecture of Electrical and Electronics Engineers Standards Association (IEEE-SA) in 2006 with virtual LANs (VLANs). 2 Why 10GbE technology is important Using faster multi-core processors is ...
10 Gigabit Ethernet technology for industry-standard servers
Page 8
... File System Disk Driver SCSI SCSI MP** iSCSI initiator File System Disk Driver SCSI iSCSI MP** TCP/IP Ethernet Direct attached block storage using SCSI/SAS* * Serial Attached SCSI ** Multipathing iSCSI target iSCSI SCSI TCP/IP Ethernet EEtthheerrnneett Remote block storage using iSCSI Initiators include software initiators and Host Bus Adapters...
... File System Disk Driver SCSI SCSI MP** iSCSI initiator File System Disk Driver SCSI iSCSI MP** TCP/IP Ethernet Direct attached block storage using SCSI/SAS* * Serial Attached SCSI ** Multipathing iSCSI target iSCSI SCSI TCP/IP Ethernet EEtthheerrnneett Remote block storage using iSCSI Initiators include software initiators and Host Bus Adapters...
HP Insight Management Agents architecture for Windows servers
Page 5
... the drives (Table 3). The storage agent supports HP SmartArray controllers as well as Fiber Channel Host Bus Adapters (HBAs) and SAS HBAs. It also provides basic information on storage controllers and their logical and physical drives. Server agent The Server agent collects the basic server information, including the server's key subsystems configurations and health information. Table...
... the drives (Table 3). The storage agent supports HP SmartArray controllers as well as Fiber Channel Host Bus Adapters (HBAs) and SAS HBAs. It also provides basic information on storage controllers and their logical and physical drives. Server agent The Server agent collects the basic server information, including the server's key subsystems configurations and health information. Table...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 13
Appendix: TCO Test Configurations and Supported Servers The following tables contain the configuration of the servers as tested. Test Configuration 1-HP ProLiant DL380 G5 Server 1 HP ProLiant DL380 G5 server 2 Quad-Core Intel® Xeon® Processor E5450 8 1GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 4 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 5 Configuration 2 Power Supply Units ROM...
Appendix: TCO Test Configurations and Supported Servers The following tables contain the configuration of the servers as tested. Test Configuration 1-HP ProLiant DL380 G5 Server 1 HP ProLiant DL380 G5 server 2 Quad-Core Intel® Xeon® Processor E5450 8 1GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 4 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 5 Configuration 2 Power Supply Units ROM...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 14
... 3-HP ProLiant BL460c G5 Server 16 HP ProLiant BL460c G5 Servers 2 Intel® Xeon® Processor L5430 4 4GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 2 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 1 Configuration ROM Revision: I23 9/29/08 iLO Revision: v1.70 pass 11 1 HP BladeSystem c7000 Enclosure 10 Fans (Rev F, 12v) 4 Power Supply Units 2 HP 1Gb...
... 3-HP ProLiant BL460c G5 Server 16 HP ProLiant BL460c G5 Servers 2 Intel® Xeon® Processor L5430 4 4GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 2 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 1 Configuration ROM Revision: I23 9/29/08 iLO Revision: v1.70 pass 11 1 HP BladeSystem c7000 Enclosure 10 Fans (Rev F, 12v) 4 Power Supply Units 2 HP 1Gb...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 13
Appendix: TCO Test Configurations and Supported Servers The following tables contain the configuration of the servers as tested. Test Configuration 1-HP ProLiant DL380 G5 Server 1 HP ProLiant DL380 G5 server 2 Quad-Core Intel® Xeon® Processor E5450 8 1GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 4 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 5 Configuration 2 Power Supply Units ROM...
Appendix: TCO Test Configurations and Supported Servers The following tables contain the configuration of the servers as tested. Test Configuration 1-HP ProLiant DL380 G5 Server 1 HP ProLiant DL380 G5 server 2 Quad-Core Intel® Xeon® Processor E5450 8 1GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 4 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 5 Configuration 2 Power Supply Units ROM...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 14
... 3-HP ProLiant BL460c G5 Server 16 HP ProLiant BL460c G5 Servers 2 Intel® Xeon® Processor L5430 4 4GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 2 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 1 Configuration ROM Revision: I23 9/29/08 iLO Revision: v1.70 pass 11 1 HP BladeSystem c7000 Enclosure 10 Fans (Rev F, 12v) 4 Power Supply Units 2 HP 1Gb...
... 3-HP ProLiant BL460c G5 Server 16 HP ProLiant BL460c G5 Servers 2 Intel® Xeon® Processor L5430 4 4GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 2 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 1 Configuration ROM Revision: I23 9/29/08 iLO Revision: v1.70 pass 11 1 HP BladeSystem c7000 Enclosure 10 Fans (Rev F, 12v) 4 Power Supply Units 2 HP 1Gb...
HP Insight Diagnostics User Guide
Page 23
... results as follows: • A SCSI hard drive containing the logical volume flashes the hard drive LED. • A SATA or SAS hard drive containing the logical volume illuminates a blue hard drive LED. Custom testing can only be related to determine the problem or use... Troubleshooting Required: A communication problem exists that may contain the volume. To cancel the test in the computer that could be performed with HP Insight Diagnostics Offline Edition. • Abnormal termination: The test terminated abnormally. Test results are indicated as follows: • Canceled: The...
... results as follows: • A SCSI hard drive containing the logical volume flashes the hard drive LED. • A SATA or SAS hard drive containing the logical volume illuminates a blue hard drive LED. Custom testing can only be related to determine the problem or use... Troubleshooting Required: A communication problem exists that may contain the volume. To cancel the test in the computer that could be performed with HP Insight Diagnostics Offline Edition. • Abnormal termination: The test terminated abnormally. Test results are indicated as follows: • Canceled: The...
Critical factors in intra-rack power distribution planning for high-density systems
Page 12
...HP ProLiant DL360 G5 server Monitored PDU Fixed cord Extension Bar Table 3 shows the difference in the 1 + 1 power supply configuration option. In one PCI-E card, two 36 GB hard drives, system utilization estimated at 40% Total VA required 8.5 kVA Two 3.0-GHz processors, 16 GB memory, two PCI-E cards, four 146-GB SAS... "For more information" section for a high-density server system based on HP ProLiant DL 360 G5 servers. Table 3. HP ProLiant DL360 G5 server power distribution configurations No. The ProLiant DL 360 G5 is nearly at maximum configuration and estimated to run ...
...HP ProLiant DL360 G5 server Monitored PDU Fixed cord Extension Bar Table 3 shows the difference in the 1 + 1 power supply configuration option. In one PCI-E card, two 36 GB hard drives, system utilization estimated at 40% Total VA required 8.5 kVA Two 3.0-GHz processors, 16 GB memory, two PCI-E cards, four 146-GB SAS... "For more information" section for a high-density server system based on HP ProLiant DL 360 G5 servers. Table 3. HP ProLiant DL360 G5 server power distribution configurations No. The ProLiant DL 360 G5 is nearly at maximum configuration and estimated to run ...
HP Insight Management WBEM Providers for Windows Server 2003 and Windows Server 2008 User Guide
Page 25
Profile Name DSP1004-Base Server Profile (specialized) Version 1.0 ...• Storage providers o Storage controller information and indications o Ultra3 and Ultra320 SCSI o SmartArray 5x and 6x o SAS/SATA information o Fibre Channel HBA information o Tape information o Host Discovered Resources (HDR) information (OS volumes) ...Enclosure information for c-Class blades o Management processor provider-Management processor information o Software inventory provider-Installed HP software information o Indications to event log provider-Insight Provider indications that are logged to the Windows...
Profile Name DSP1004-Base Server Profile (specialized) Version 1.0 ...• Storage providers o Storage controller information and indications o Ultra3 and Ultra320 SCSI o SmartArray 5x and 6x o SAS/SATA information o Fibre Channel HBA information o Tape information o Host Discovered Resources (HDR) information (OS volumes) ...Enclosure information for c-Class blades o Management processor provider-Management processor information o Software inventory provider-Installed HP software information o Indications to event log provider-Insight Provider indications that are logged to the Windows...
HP Insight Management WBEM Providers for Windows Server 2003 and Windows Server 2008 User Guide
Page 28
... Profile Name Version P00105-HP Base Server 1.1 Profile P00106-HP CPU Profile 1.0 P00107-HP CPU 1.0 Consolidated Status Profile P00108-HP CPU Physical 1.0 Asset Profile P00109-HP Record Log 1.1 Profile P00110-HP Memory Profile 1.0 P00111-HP Memory 1.0 Physical Asset Profile P00113-HP Consolidated 1.0 Status Profile P00114-HP Base Server 1.2 Physical Asset Profile P00115-HP Fan Physical 1.0 Asset Profile P00116-HP Power Supply 1.0 Physical Asset...
... Profile Name Version P00105-HP Base Server 1.1 Profile P00106-HP CPU Profile 1.0 P00107-HP CPU 1.0 Consolidated Status Profile P00108-HP CPU Physical 1.0 Asset Profile P00109-HP Record Log 1.1 Profile P00110-HP Memory Profile 1.0 P00111-HP Memory 1.0 Physical Asset Profile P00113-HP Consolidated 1.0 Status Profile P00114-HP Base Server 1.2 Physical Asset Profile P00115-HP Fan Physical 1.0 Asset Profile P00116-HP Power Supply 1.0 Physical Asset...
HP Insight Management WBEM Providers for Windows Server 2003 and Windows Server 2008 User Guide
Page 38
NIC network interface controller PCI peripheral component interface POST Power-On Self Test PSP ProLiant Support Pack ROM read-only memory SAS serial attached SCSI SATA serial ATA SCSI small computer system interface SMASH System Management Architecture for Server Hardware SMH System Management Homepage SMI-S Storage Management Initiative Specification SNMP Simple Network Management Protocol WBEM Web-Based Enterprise Management WMI Windows Management Instrumentation Acronyms and abbreviations 38
NIC network interface controller PCI peripheral component interface POST Power-On Self Test PSP ProLiant Support Pack ROM read-only memory SAS serial attached SCSI SATA serial ATA SCSI small computer system interface SMASH System Management Architecture for Server Hardware SMH System Management Homepage SMI-S Storage Management Initiative Specification SNMP Simple Network Management Protocol WBEM Web-Based Enterprise Management WMI Windows Management Instrumentation Acronyms and abbreviations 38
Drive technology overview
Page 1
... drive capacity...4 Disk drive performance...4 Reliability ...5 Drive qualification process...6 Interconnect technology ...7 Serial Attached SCSI (SAS) ...7 SAS-2 ...8 Second generation Serial ATA (SATA 8 Interconnect bandwidths and drive throughput 8 Improved performance and reliability with RAID 9 Advanced controllers ...9 Solid state drives for servers...9 HP solid state drive reliability requirements 10 NAND over provisioning and wear-levelling 10 Power...
... drive capacity...4 Disk drive performance...4 Reliability ...5 Drive qualification process...6 Interconnect technology ...7 Serial Attached SCSI (SAS) ...7 SAS-2 ...8 Second generation Serial ATA (SATA 8 Interconnect bandwidths and drive throughput 8 Improved performance and reliability with RAID 9 Advanced controllers ...9 Solid state drives for servers...9 HP solid state drive reliability requirements 10 NAND over provisioning and wear-levelling 10 Power...
Drive technology overview
Page 2
...larger than accessing main memory. Typical intended applications for Entry drives are designed for mission-critical applications. 2 Categories of server disk drives HP has refined and expanded its drive family to offer three distinct classes of different environments. This technology brief reviews the ... reliability in single drives, the options available to connect the drives to meet both Serial ATA (SATA) and Serial Attached SCSI (SAS) interfaces. The cost per bit. Flash memory technology, which has previously been used as boot disks for storing and retrieving permanent,...
...larger than accessing main memory. Typical intended applications for Entry drives are designed for mission-critical applications. 2 Categories of server disk drives HP has refined and expanded its drive family to offer three distinct classes of different environments. This technology brief reviews the ... reliability in single drives, the options available to connect the drives to meet both Serial ATA (SATA) and Serial Attached SCSI (SAS) interfaces. The cost per bit. Flash memory technology, which has previously been used as boot disks for storing and retrieving permanent,...
Drive technology overview
Page 3
... disk drives This section identifies basic characteristics of hard drives. HP Enterprise drives provide maximum reliability, highest performance, scalability, and error management under the most SAS-based StorageWorks and HP Integrity server products as well. Categories of drives designed for use in ...reliability intended for implementations that affect them. Mission critical - Technological advances continue to fit mechanically and electrically with HP ProLiant servers or storage products. The smaller 2.5-inch drives can be supported by -side comparison of the three classes of...
... disk drives This section identifies basic characteristics of hard drives. HP Enterprise drives provide maximum reliability, highest performance, scalability, and error management under the most SAS-based StorageWorks and HP Integrity server products as well. Categories of drives designed for use in ...reliability intended for implementations that affect them. Mission critical - Technological advances continue to fit mechanically and electrically with HP ProLiant servers or storage products. The smaller 2.5-inch drives can be supported by -side comparison of the three classes of...
Drive technology overview
Page 7
...-effective solution for industry-standard servers 2nd Gen. Comparison of the link available to each device, which each drive has its own high-speed serial communication channel to -point serial interface, with SATA controllers. 7 In fact, SATA and SAS drives can be used to ... be mixed) worldwide unique ID set at HP option kitting configuration sites. However, SAS devices cannot be mixed in a single enclosure. SAS inherits the proven SCSI command set 1 per link 2-6 typical ATA 16,256 (SAS fabric) 512 - 2048 practical Unlimited (SAS fabric) 512 - 2048 practical SCSI SCSI ...
...-effective solution for industry-standard servers 2nd Gen. Comparison of the link available to each device, which each drive has its own high-speed serial communication channel to -point serial interface, with SATA controllers. 7 In fact, SATA and SAS drives can be used to ... be mixed) worldwide unique ID set at HP option kitting configuration sites. However, SAS devices cannot be mixed in a single enclosure. SAS inherits the proven SCSI command set 1 per link 2-6 typical ATA 16,256 (SAS fabric) 512 - 2048 practical Unlimited (SAS fabric) 512 - 2048 practical SCSI SCSI ...
Drive technology overview
Page 8
... 8 The SATA specification was initially released in three variants: 1.5 Gb/s 1.5 Gb/s with HP ProLiant G6 servers in the SAS expanders. It is based on a disk controller. The 6 Gb/s SAS-2 interface and SAS-2 compliant drives provides little or no performance advantage over standard 3 Gb/s SAS when used in the desktop and consumer markets. SATA 1.5 Gb/s with...
... 8 The SATA specification was initially released in three variants: 1.5 Gb/s 1.5 Gb/s with HP ProLiant G6 servers in the SAS expanders. It is based on a disk controller. The 6 Gb/s SAS-2 interface and SAS-2 compliant drives provides little or no performance advantage over standard 3 Gb/s SAS when used in the desktop and consumer markets. SATA 1.5 Gb/s with...