Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 57
... of an ATA disk drive. NT Event ID: 1187 (Hex)0x843504a3 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: ATA RAID Logical Drive Status Change. The variable cpqIdeLogicalDriveStatus indicates the current logical drive status. User Action: If the physical drive status is failed(5),... in the status of %2. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. This trap indicates that need replacement. Log Message: ATA RAID logical drive number %6 on the "%5" in CPQIDE.MIB Symptom: IDE Logical Drive Status Change. NT Event ID: 1188 (Hex)0x843504a4 (...
... of an ATA disk drive. NT Event ID: 1187 (Hex)0x843504a3 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: ATA RAID Logical Drive Status Change. The variable cpqIdeLogicalDriveStatus indicates the current logical drive status. User Action: If the physical drive status is failed(5),... in the status of %2. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. This trap indicates that need replacement. Log Message: ATA RAID logical drive number %6 on the "%5" in CPQIDE.MIB Symptom: IDE Logical Drive Status Change. NT Event ID: 1188 (Hex)0x843504a4 (...
ProLiant Essentials Foundation Pack Installation Guide
Page 1
... configuring the hardware, boot the operating system CD to prepare the server for Arrays) or the Adaptec RAID Configuration Utility as shown on your ProLiant server. Server setup walks you through Subscriber's Choice at www.hp.com/servers/proliantessentials SmartStart Installation Guidelines SmartStart performs server setup by assisting hardware configuration and installation of...
... configuring the hardware, boot the operating system CD to prepare the server for Arrays) or the Adaptec RAID Configuration Utility as shown on your ProLiant server. Server setup walks you through Subscriber's Choice at www.hp.com/servers/proliantessentials SmartStart Installation Guidelines SmartStart performs server setup by assisting hardware configuration and installation of...
HP Insight Server Migration Software for ProLiant User Guide
Page 29
...based console Linux SMP VM Host Agent operating system running Linux Virtual machine destination on agent-less host SMP Virtual Boot CD Using the HP SIM CMS to deploy SMP Agent You can use this CD to install SMP application or SMP Source Agent, or to boot physical ...system running Windows Windows SMP VM Host Agent Virtual machine destination on host with encrypted partitions (Software RAID is not supported) • Running any post-migration steps such as Linux Support Packs installation and HP SIM discovery SMP Boot CDs • SMP Physical Boot CD-This is launched. 3. The Show...
...based console Linux SMP VM Host Agent operating system running Linux Virtual machine destination on agent-less host SMP Virtual Boot CD Using the HP SIM CMS to deploy SMP Agent You can use this CD to install SMP application or SMP Source Agent, or to boot physical ...system running Windows Windows SMP VM Host Agent Virtual machine destination on host with encrypted partitions (Software RAID is not supported) • Running any post-migration steps such as Linux Support Packs installation and HP SIM discovery SMP Boot CDs • SMP Physical Boot CD-This is launched. 3. The Show...
HP Insight Server Migration Software for ProLiant User Guide
Page 51
... it contains the boot partition and cannot be migrated. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to a single contiguous partition. Physical-to the target boot disk. You cannot migrate or select unsupported file systems. The boot partition must... (which contains the boot.ini, NTLDR, and NTDETECT.com files) is already running on the application station wizard. If SMP Source Agent is migrated to -ProLiant (P2P) migrations for Windows 51 3.
... it contains the boot partition and cannot be migrated. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to a single contiguous partition. Physical-to the target boot disk. You cannot migrate or select unsupported file systems. The boot partition must... (which contains the boot.ini, NTLDR, and NTDETECT.com files) is already running on the application station wizard. If SMP Source Agent is migrated to -ProLiant (P2P) migrations for Windows 51 3.
HP Insight Server Migration Software for ProLiant User Guide
Page 70
... boot partition is migrated to the target boot disk. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to a single contiguous partition. Volumes on dynamic disks are selected by default. If only one active volume exists, by default it contains...
... boot partition is migrated to the target boot disk. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to a single contiguous partition. Volumes on dynamic disks are selected by default. If only one active volume exists, by default it contains...
HP Insight Server Migration Software for ProLiant User Guide
Page 84
... resize NTFS partitions. 84 Using SMP for server migration If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are selected by default. Volumes stored on a common source disk must be migrated. If only one active volume exists, by default it contains the...
... resize NTFS partitions. 84 Using SMP for server migration If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are selected by default. Volumes stored on a common source disk must be migrated. If only one active volume exists, by default it contains the...
HP Insight Server Migration Software for ProLiant User Guide
Page 96
... boot disk and loaded using NT Boot Loader (NTLDR). If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to be migrated. The operating system must be stored on basic disks. Select the volumes to the source server, and then install...
... boot disk and loaded using NT Boot Loader (NTLDR). If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to be migrated. The operating system must be stored on basic disks. Select the volumes to the source server, and then install...
HP Insight Server Migration Software for ProLiant User Guide
Page 104
...you must be selected. NOTE: To migrate Windows 2003 to local disks on the same server. HP SIM integration When SMP is not required. After a successful migration, manually install the ProLiant Support Pack on the same server. Access the Windows Device manager. d. Click Update driver. ...appropriate hosts discovered in HP SIM, click Show Host List. In step 6 of Windows 2000 Server or Advanced Server (with SP4) to a destination server with some source disks migrated to SAN disks presented to the Emulex HBA. g. Expand the SCSI and RAID controllers group. Click ...
...you must be selected. NOTE: To migrate Windows 2003 to local disks on the same server. HP SIM integration When SMP is not required. After a successful migration, manually install the ProLiant Support Pack on the same server. Access the Windows Device manager. d. Click Update driver. ...appropriate hosts discovered in HP SIM, click Show Host List. In step 6 of Windows 2000 Server or Advanced Server (with SP4) to a destination server with some source disks migrated to SAN disks presented to the Emulex HBA. g. Expand the SCSI and RAID controllers group. Click ...
HP Insight Server Migration Software for ProLiant User Guide
Page 132
... blue screen on the destination server. The driver for the Emulex LPe1105-HP 4Gb FC HBA. a. e. b. Click the Hardware tab, and then select Hardware profiles. After Windows boots, install the ProLiant Support Pack on the source. c. Error during data copy of Linux ...resolve this issue: 1. Right-click the device corresponding to Profile 1 Hardware Profile. 2. Click Properties. 132 Troubleshooting a. Expand the SCSI and RAID controllers group. Right-click My Computer, and then select Properties. Select SMP Source Agent Mode, and then click Delete. 3. When the Windows...
... blue screen on the destination server. The driver for the Emulex LPe1105-HP 4Gb FC HBA. a. e. b. Click the Hardware tab, and then select Hardware profiles. After Windows boots, install the ProLiant Support Pack on the source. c. Error during data copy of Linux ...resolve this issue: 1. Right-click the device corresponding to Profile 1 Hardware Profile. 2. Click Properties. 132 Troubleshooting a. Expand the SCSI and RAID controllers group. Right-click My Computer, and then select Properties. Select SMP Source Agent Mode, and then click Delete. 3. When the Windows...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 11
... latest drivers. NOTE All storage option drivers have a digital signature. This package is available on the HP website: www.hp.com/go/ws2008. Table 3. HP has updated the ProLiant Support Pack 8.00 for Windows 2000/Server 2003 6-Port SATA RAID Controller AAC.SYS 9 99 9 9 9 9 Internal 4/8 Port SAS HBA LSI_SAS.SYS 9 99 9 9 Smart Array: E200 E200i...
... latest drivers. NOTE All storage option drivers have a digital signature. This package is available on the HP website: www.hp.com/go/ws2008. Table 3. HP has updated the ProLiant Support Pack 8.00 for Windows 2000/Server 2003 6-Port SATA RAID Controller AAC.SYS 9 99 9 9 9 9 Internal 4/8 Port SAS HBA LSI_SAS.SYS 9 99 9 9 Smart Array: E200 E200i...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 18
...time and configure the boot controller order (if necessary). Use the Array Configuration Utility to use iLO virtual media with HP ProLiant ML or HP ProLiant DL servers. 2. Pre-installation tasks To prepare for installation, ensure that the server has a DVD drive (either native to ... required to configure the RAID settings for the server. Install the HP Insight Management Agents only after SNMP is supported through manual and assisted path installation options. Windows Server 2008 installation for 32-bit and 64-bit editions on ProLiant servers Server deployment of Windows...
...time and configure the boot controller order (if necessary). Use the Array Configuration Utility to use iLO virtual media with HP ProLiant ML or HP ProLiant DL servers. 2. Pre-installation tasks To prepare for installation, ensure that the server has a DVD drive (either native to ... required to configure the RAID settings for the server. Install the HP Insight Management Agents only after SNMP is supported through manual and assisted path installation options. Windows Server 2008 installation for 32-bit and 64-bit editions on ProLiant servers Server deployment of Windows...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 23
...be reported by certain storage applications for logical volumes on an HP Smart Array controller, these polices in Table 2. Description During installation...system32\drivers directory (and any other locations) or removing any effect. Description An LSI IDE RAID driver is injected, no workaround at this error occurs, download and install iLO 2 firmware ... volumes. Description A blue screen displaying a "BUGCODE_USB_DRIVER" error may display during Driver Injection on ProLiant servers (Windows Server 2008 32-bit and x64 editions) Issue Details Issue 1 The write cache...
...be reported by certain storage applications for logical volumes on an HP Smart Array controller, these polices in Table 2. Description During installation...system32\drivers directory (and any other locations) or removing any effect. Description An LSI IDE RAID driver is injected, no workaround at this error occurs, download and install iLO 2 firmware ... volumes. Description A blue screen displaying a "BUGCODE_USB_DRIVER" error may display during Driver Injection on ProLiant servers (Windows Server 2008 32-bit and x64 editions) Issue Details Issue 1 The write cache...
Implementing Microsoft Windows Server 2008 Foundation on HP ProLiant servers
Page 7
...: • Increasing server manageability • Enabling administrators to configure the RAID settings for Microsoft Windows Server 2008 Foundation Version 8.25 is supported with Windows Server 2008 Foundation on the following ProLiant series servers: • ProLiant DL300 series servers • ProLiant ML300 series servers The HP ProLiant Easy Set-up CD is supported with Windows Server 2008...
...: • Increasing server manageability • Enabling administrators to configure the RAID settings for Microsoft Windows Server 2008 Foundation Version 8.25 is supported with Windows Server 2008 Foundation on the following ProLiant series servers: • ProLiant DL300 series servers • ProLiant ML300 series servers The HP ProLiant Easy Set-up CD is supported with Windows Server 2008...
ISS Technology Focus, Number 11
Page 2
... hot-add new DIMMs, all without taking down the server. • In 2003, HP introduced Hot Plug RAID memory in ProLiant DL760 G2 servers to protect against uncorrectable memory errors that would otherwise result in a server failure. The future: HP Advanced Memory Error Detection Technology The higher occurrence of memory errors has increased the...
... hot-add new DIMMs, all without taking down the server. • In 2003, HP introduced Hot Plug RAID memory in ProLiant DL760 G2 servers to protect against uncorrectable memory errors that would otherwise result in a server failure. The future: HP Advanced Memory Error Detection Technology The higher occurrence of memory errors has increased the...
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 3
...5 Utilities available for configuring an array ...5 Comparison of the utilities ...5 Support for standard configuration tasks 6 Support for advanced configuration tasks 6 HP Smart Array Advanced Pack ...8 About SAAP ...8 Required hardware ...8 Option ROM Configuration for Arrays 10 About ORCA ...10 Using the ORCA menu-driven... the rebuild priority or expand priority 19 Setting the accelerator ratio...19 Expanding an array ...20 Migrating RAID level or stripe size ...20 HP Array Configuration Utility ...22 About ACU...22 Accessing ACU in the offline environment...22 Launching ACU with...
...5 Utilities available for configuring an array ...5 Comparison of the utilities ...5 Support for standard configuration tasks 6 Support for advanced configuration tasks 6 HP Smart Array Advanced Pack ...8 About SAAP ...8 Required hardware ...8 Option ROM Configuration for Arrays 10 About ORCA ...10 Using the ORCA menu-driven... the rebuild priority or expand priority 19 Setting the accelerator ratio...19 Expanding an array ...20 Migrating RAID level or stripe size ...20 HP Array Configuration Utility ...22 About ACU...22 Accessing ACU in the offline environment...22 Launching ACU with...
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 4
... ...74 Script file options ...75 XML support ...88 ACU scripting warning messages ...91 ACU scripting error messages ...91 HP Array Diagnostics and SmartSSD Wear Gauge Utility 96 About the utility ...96 Reported information ...96 Installing the utility ...98 ...Fault-tolerance methods...109 RAID 0-No fault tolerance...109 RAID 1 and RAID 1+0 (RAID 10) ...110 RAID 1 (ADM) and RAID 10 (ADM 111 RAID 5-distributed data guarding 113 RAID 6 (ADG)-Advanced Data Guarding 113 RAID 50 ...115 RAID 60 ...116 Comparing the hardware-based RAID methods 116 Selecting a RAID method...117 Alternative fault...
... ...74 Script file options ...75 XML support ...88 ACU scripting warning messages ...91 ACU scripting error messages ...91 HP Array Diagnostics and SmartSSD Wear Gauge Utility 96 About the utility ...96 Reported information ...96 Installing the utility ...98 ...Fault-tolerance methods...109 RAID 0-No fault tolerance...109 RAID 1 and RAID 1+0 (RAID 10) ...110 RAID 1 (ADM) and RAID 10 (ADM 111 RAID 5-distributed data guarding 113 RAID 6 (ADG)-Advanced Data Guarding 113 RAID 50 ...115 RAID 60 ...116 Comparing the hardware-based RAID methods 116 Selecting a RAID method...117 Alternative fault...
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 5
...you use, remember the following factors when you use of drive space, all logical drives in an array with a suitable fault-tolerance (RAID) method. Where the utility can Any machine that uses a be used supported browser CPQONLIN Menu-based English Software CD or Web Any time... capacity. Overview of array configuration tools Utilities available for configuring an array To configure an array on an HP Smart Array controller, three utilities are available: • HP Array Configuration Utility (ACU)-An advanced utility that enables you to perform many complex configuration tasks • ...
...you use, remember the following factors when you use of drive space, all logical drives in an array with a suitable fault-tolerance (RAID) method. Where the utility can Any machine that uses a be used supported browser CPQONLIN Menu-based English Software CD or Web Any time... capacity. Overview of array configuration tools Utilities available for configuring an array To configure an array on an HP Smart Array controller, three utilities are available: • HP Array Configuration Utility (ACU)-An advanced utility that enables you to perform many complex configuration tasks • ...
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 6
... A "+" indicates the feature or task is not supported. For more information, see the controller user guide or the HP website (http://www.hp.com/products/smartarray). Some of these symbols: + -The ACU format supports this task. - -The ACU format does... CLI + +1 +/- +/- -1 + + ACU Scripting Overview of the logical drive + Create multiple logical drives per array + Set the stripe size + Migrate the RAID level or stripe size + Expand an array + Set the expand priority, migrate priority, and accelerator ratio + Extend a logical drive + Set the boot controller +...
... A "+" indicates the feature or task is not supported. For more information, see the controller user guide or the HP website (http://www.hp.com/products/smartarray). Some of these symbols: + -The ACU format supports this task. - -The ACU format does... CLI + +1 +/- +/- -1 + + ACU Scripting Overview of the logical drive + Create multiple logical drives per array + Set the stripe size + Migrate the RAID level or stripe size + Expand an array + Set the expand priority, migrate priority, and accelerator ratio + Extend a logical drive + Set the boot controller +...
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 7
... redundant controllers) Shrink an array (restripe the data on an array to occupy fewer +/-2 physical drives, then remove the excess drives from the array) Split a RAID 1 array or recombine a split array (offline only) +/- 1Scripting is the most efficient method for this task. 2The task is supported only from the Configuration screen...
... redundant controllers) Shrink an array (restripe the data on an array to occupy fewer +/-2 physical drives, then remove the excess drives from the array) Split a RAID 1 array or recombine a split array (offline only) +/- 1Scripting is the most efficient method for this task. 2The task is supported only from the Configuration screen...
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 8
...list of additional and advanced controller features embedded in ACU. HP Smart Array Advanced Pack About SAAP SAAP is standard on the HP Smart Array P812 Controller.) SAAP 1.0 provides the following features: • RAID 6 (ADG) • RAID 60 (ADG) • Advanced Capacity Expansion • ... and deleting individual LUNs To access SAAP features, you must purchase a license key from HP. Required hardware For a list of the following additional features: • RAID 1 (ADM) • RAID 10 (ADM) • Capability for advanced configuration tasks (on page 6)." To install the...
...list of additional and advanced controller features embedded in ACU. HP Smart Array Advanced Pack About SAAP SAAP is standard on the HP Smart Array P812 Controller.) SAAP 1.0 provides the following features: • RAID 6 (ADG) • RAID 60 (ADG) • Advanced Capacity Expansion • ... and deleting individual LUNs To access SAAP features, you must purchase a license key from HP. Required hardware For a list of the following additional features: • RAID 1 (ADM) • RAID 10 (ADM) • Capability for advanced configuration tasks (on page 6)." To install the...