Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 130
... Log Message: Unable to the registry. Installing a later version of the driver may correct this error. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct the problem. The data contain the error code. Event identifier:...0xc435010d (Service Event) Log Severity: Error (3) Log Message: The NIC Management Agent encountered a fatal error. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct the problem. Removing and reinstalling the device may correct this...
... Log Message: Unable to the registry. Installing a later version of the driver may correct this error. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct the problem. The data contain the error code. Event identifier:...0xc435010d (Service Event) Log Severity: Error (3) Log Message: The NIC Management Agent encountered a fatal error. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct the problem. Removing and reinstalling the device may correct this...
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 131
...identifier: cpqnimsg.dll - 276 (Hex)0x84350114 (Service Event) Log Severity: Warning (2) Log Message: The NIC Management Agent cannot communicate with the team and re-install the drivers and team. Event identifier: cpqnimsg.dll - 285 (Hex)0x8435011d (Service Event) Log Severity: Warning (2)... Log Message: The NIC Management Agent could not start any agents successfully. Remove all device instances associated with the Token Ring Protocol driver (CNMPROT.SYS). Event identifier: cpqnimsg.dll - 277 (Hex)0x44350115 (Service Event)...
...identifier: cpqnimsg.dll - 276 (Hex)0x84350114 (Service Event) Log Severity: Warning (2) Log Message: The NIC Management Agent cannot communicate with the team and re-install the drivers and team. Event identifier: cpqnimsg.dll - 285 (Hex)0x8435011d (Service Event) Log Severity: Warning (2)... Log Message: The NIC Management Agent could not start any agents successfully. Remove all device instances associated with the Token Ring Protocol driver (CNMPROT.SYS). Event identifier: cpqnimsg.dll - 277 (Hex)0x44350115 (Service Event)...
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 132
...the error code. Event identifier: cpqnimsg.dll - 292 (Hex)0x84350124 (Service Event) Log Severity: Warning (2) Log Message: The NIC Agent service could get the control function for agent *"%1". Event identifier: cpqnimsg.dll - 296 (Hex)0xc4350128 (Service Event) Log Severity: Error... (3) Log Message: A driver for a NIC failed to any management requests. Event identifier: cpqnimsg.dll - 297 (Hex)0x84350129 (Service Event) Log Severity: Warning (2) Log Message:...
...the error code. Event identifier: cpqnimsg.dll - 292 (Hex)0x84350124 (Service Event) Log Severity: Warning (2) Log Message: The NIC Agent service could get the control function for agent *"%1". Event identifier: cpqnimsg.dll - 296 (Hex)0xc4350128 (Service Event) Log Severity: Error... (3) Log Message: A driver for a NIC failed to any management requests. Event identifier: cpqnimsg.dll - 297 (Hex)0x84350129 (Service Event) Log Severity: Warning (2) Log Message:...
HP Insight Server Migration Software for ProLiant User Guide
Page 6
... on the NIC adapter in SMP Agent Mode 131 Error during data copy of Linux migration 132 Destination server reboots continuously with a blue screen 132 SAN-connected destination server displays blue ... of HP integrated Citrix XenServer fails 126 Mouse does not work after migrating a Hyper-V virtual machine to a ProLiant server........134 Static IP address cannot be assigned on the destination server after...Destination server boots from the SMP boot CD on a manual boot 129 Migration process...129 Drivers cannot be installed or injected onto boot disk 129 Large volumes fail with server ...
... on the NIC adapter in SMP Agent Mode 131 Error during data copy of Linux migration 132 Destination server reboots continuously with a blue screen 132 SAN-connected destination server displays blue ... of HP integrated Citrix XenServer fails 126 Mouse does not work after migrating a Hyper-V virtual machine to a ProLiant server........134 Static IP address cannot be assigned on the destination server after...Destination server boots from the SMP boot CD on a manual boot 129 Migration process...129 Drivers cannot be installed or injected onto boot disk 129 Large volumes fail with server ...
HP Insight Server Migration Software for ProLiant User Guide
Page 18
..., and all drivers (including NIC drivers) on Linux file systems are available for a Linux source server Bad blocks on the destination server. Resize is maintained in the right configuration. For more information for required post-migration configurations, for P2P migrations see the P2V post-migration tasks section. Table 1-1 Related HP products for high-volume ProLiant server installations. To...
..., and all drivers (including NIC drivers) on Linux file systems are available for a Linux source server Bad blocks on the destination server. Resize is maintained in the right configuration. For more information for required post-migration configurations, for P2P migrations see the P2V post-migration tasks section. Table 1-1 Related HP products for high-volume ProLiant server installations. To...
HP Insight Server Migration Software for ProLiant User Guide
Page 55
...to the Next wizard page. • Disk 0, Disk 1, Disk2, and so on-For each destination NIC as needed , do not enter any IP address addresses. 12. If PSP executables are available. NOTE...and then click Begin Migration. For information on how to upload PSP executables, see the Upload Drivers section. • Select a PSP to install on the destination disk after the migration is ...following options: • The destination server must be powered off after migration is complete. • The destination server must be reserved on the destination disk to -ProLiant (P2P) migrations for Windows 55...
...to the Next wizard page. • Disk 0, Disk 1, Disk2, and so on-For each destination NIC as needed , do not enter any IP address addresses. 12. If PSP executables are available. NOTE...and then click Begin Migration. For information on how to upload PSP executables, see the Upload Drivers section. • Select a PSP to install on the destination disk after the migration is ...following options: • The destination server must be powered off after migration is complete. • The destination server must be reserved on the destination disk to -ProLiant (P2P) migrations for Windows 55...
HP Insight Server Migration Software for ProLiant User Guide
Page 57
... file, and update the boot entry with administrative rights. 2. Additionally, to -ProLiant (P2P) migrations for Linux Preparing for a P2P migration The following sections list prerequisites... be re-established on the destination server, then NIC teaming must be disabled at any services or drivers that might not be immediately active ...Server 2003, Enterprise" /sos /bootlog /noexecute=optout /fastdetect multi(0)disk(0)rdisk(0)partition(1)\WINDOWS="HP SMP Preserved: Windows Server 2003, Enterprise" /userva=3030 /3gb /noexecute=optout /fastdetect 11. During migration, all required drivers...
... file, and update the boot entry with administrative rights. 2. Additionally, to -ProLiant (P2P) migrations for Linux Preparing for a P2P migration The following sections list prerequisites... be re-established on the destination server, then NIC teaming must be disabled at any services or drivers that might not be immediately active ...Server 2003, Enterprise" /sos /bootlog /noexecute=optout /fastdetect multi(0)disk(0)rdisk(0)partition(1)\WINDOWS="HP SMP Preserved: Windows Server 2003, Enterprise" /userva=3030 /3gb /noexecute=optout /fastdetect 11. During migration, all required drivers...
HP Insight Server Migration Software for ProLiant User Guide
Page 101
..., the network settings on the destination server and configure a static IP for each destination NIC as needed. 13. If PSP executables are available. Click Next. 14. • If the destination server is selected to -ProLiant (V2P) migrations 101 For information on how to upload PSP executables, see the Upload Drivers section. • Select a PSP to...
..., the network settings on the destination server and configure a static IP for each destination NIC as needed. 13. If PSP executables are available. Click Next. 14. • If the destination server is selected to -ProLiant (V2P) migrations 101 For information on how to upload PSP executables, see the Upload Drivers section. • Select a PSP to...
HP Insight Server Migration Software for ProLiant User Guide
Page 102
...HP SIM WIN Conversion ProLiant Windows. 3. Install the latest HP ProLiant Support Pack, which includes ProLiant optimized drivers, utilities, and management agents. To successfully install the ProLiant Support Pack, SNMP service must be set up at the System Settings Change window, click No. 5. View the Windows event log on the destination server... Wizard appears. Review the migration progress details. Check the network connections and reestablish NIC teaming, if necessary. 7. These options are automatically inserted during boot is highlighted and the original boot.ini entry appears ...
...HP SIM WIN Conversion ProLiant Windows. 3. Install the latest HP ProLiant Support Pack, which includes ProLiant optimized drivers, utilities, and management agents. To successfully install the ProLiant Support Pack, SNMP service must be set up at the System Settings Change window, click No. 5. View the Windows event log on the destination server... Wizard appears. Review the migration progress details. Check the network connections and reestablish NIC teaming, if necessary. 7. These options are automatically inserted during boot is highlighted and the original boot.ini entry appears ...
HP Insight Server Migration Software for ProLiant User Guide
Page 134
...yellow or red sign. 4. Open a command prompt on the destination server and enter the following task to assign a driver letter to the volume so it is installed automatically on the destination server after a migration. In the device manager select view, and then select...and then select uninstall. 5. Reconfigure the NIC connected to the network to accept a static IP address. 2. Assign the driver letter in Windows Explorer. Destination server mouse and keyboard do not work after migrating a Hyper-V virtual machine to a ProLiant server Before performing a migration, uninstall Hyper-V...
...yellow or red sign. 4. Open a command prompt on the destination server and enter the following task to assign a driver letter to the volume so it is installed automatically on the destination server after a migration. In the device manager select view, and then select...and then select uninstall. 5. Reconfigure the NIC connected to the network to accept a static IP address. 2. Assign the driver letter in Windows Explorer. Destination server mouse and keyboard do not work after migrating a Hyper-V virtual machine to a ProLiant server Before performing a migration, uninstall Hyper-V...
HP Insight Server Migration Software for ProLiant User Guide
Page 135
..., click Yes. This might be unable to assign the IP address to another adapter. This detects the NIC adapter and configures the drivers for Hardware Changes. To resolve this issue: 1. After the installation is migrated from the SMP installation folder... station, click Start→Programs→HP Insight Server Migration software for ProLiant→Uninstall HP Insight Server Migration software for this issue, you have entered for ProLiant. 3. Power up the virtual machine, and then restart the installation of a different server. 2. Troubleshooting 135 For more information,...
..., click Yes. This might be unable to assign the IP address to another adapter. This detects the NIC adapter and configures the drivers for Hardware Changes. To resolve this issue: 1. After the installation is migrated from the SMP installation folder... station, click Start→Programs→HP Insight Server Migration software for ProLiant→Uninstall HP Insight Server Migration software for this issue, you have entered for ProLiant. 3. Power up the virtual machine, and then restart the installation of a different server. 2. Troubleshooting 135 For more information,...
HP Insight Server Migration Software for ProLiant User Guide
Page 146
... is required for source servers with HP iLO Management Channel Interface Drivers, 123 Deploy Agent task fails, 124, 128 destination server displays blank screen when using SMP Boot CD, 126 destination server identification fails, 126 DNS error appears in destination server after migration of domain controllers... server for P2V migration, 131 V2V, 131 Yellow bang (!) appears on NIC adapter, 135 U uninstallation troubleshooting, 135 uninstalling older version of SMP application, 135 SMP application, 135 upgrading to SMP from SMP or P2P, 13 uploading drivers, 119 V V2P (see virtual-to-ProLiant)...
... is required for source servers with HP iLO Management Channel Interface Drivers, 123 Deploy Agent task fails, 124, 128 destination server displays blank screen when using SMP Boot CD, 126 destination server identification fails, 126 DNS error appears in destination server after migration of domain controllers... server for P2V migration, 131 V2V, 131 Yellow bang (!) appears on NIC adapter, 135 U uninstallation troubleshooting, 135 uninstalling older version of SMP application, 135 SMP application, 135 upgrading to SMP from SMP or P2P, 13 uploading drivers, 119 V V2P (see virtual-to-ProLiant)...
HP Insight Management Agents architecture for Windows servers
Page 6
... information collected by the Windows OS and stored in MIB-II in the managed server. The Storage agent and Insight Management Agents are designed to the single host server. Additional information on the network, such as belonging to collect and report information ... Specification (SMI-S) Storage Providers. Multi-host storage on HP support for the network controllers. Table 4. Table 4 lists the categories and sources of the information is not reported through the NIC miniport driver. NIC agent The NIC agent collects and stores information about the network controllers installed...
... information collected by the Windows OS and stored in MIB-II in the managed server. The Storage agent and Insight Management Agents are designed to the single host server. Additional information on the network, such as belonging to collect and report information ... Specification (SMI-S) Storage Providers. Multi-host storage on HP support for the network controllers. Table 4. Table 4 lists the categories and sources of the information is not reported through the NIC miniport driver. NIC agent The NIC agent collects and stores information about the network controllers installed...
Implementing Microsoft Windows Server 2003 with Service Pack 1 on ProLiant servers integration note
Page 11
... Yes N1000325.SYS ProLiant Support Pack for Yes Microsoft Windows Server 2003 Version 7.30A Q57XP32.SYS ProLiant Support Pack for Yes Microsoft Windows Server 2003 Version 7.30A N1000325.SYS ProLiant Support Pack for Yes Microsoft Windows Server 2003 Version 7.30A 11 Table 5. Supported network interface controllers Table 5 lists supported ProLiant network interface controllers (NICs) and driver revisions supported by...
... Yes N1000325.SYS ProLiant Support Pack for Yes Microsoft Windows Server 2003 Version 7.30A Q57XP32.SYS ProLiant Support Pack for Yes Microsoft Windows Server 2003 Version 7.30A N1000325.SYS ProLiant Support Pack for Yes Microsoft Windows Server 2003 Version 7.30A 11 Table 5. Supported network interface controllers Table 5 lists supported ProLiant network interface controllers (NICs) and driver revisions supported by...
Implementing Microsoft Windows Server 2003 with Service Pack 1 on ProLiant servers integration note
Page 12
NIC NC320T PCI Express Gigabit Server Adapter NC370T PCI-X Gigabit Server Adapter NC370F PCI-X Gigabit Server Adapter Driver Location Q57XP32.SYS BXND51X.SYS BXND51X.SYS ProLiant Support Pack for Microsoft Windows Server 2003 Version 7.30A ProLiant Support Pack for Microsoft Windows Server 2003 Version 7.30A ProLiant Support Pack for Microsoft Windows Server 2003 Version 7.30A Digital Signature Yes Yes Yes NC370i PCI...
NIC NC320T PCI Express Gigabit Server Adapter NC370T PCI-X Gigabit Server Adapter NC370F PCI-X Gigabit Server Adapter Driver Location Q57XP32.SYS BXND51X.SYS BXND51X.SYS ProLiant Support Pack for Microsoft Windows Server 2003 Version 7.30A ProLiant Support Pack for Microsoft Windows Server 2003 Version 7.30A ProLiant Support Pack for Microsoft Windows Server 2003 Version 7.30A Digital Signature Yes Yes Yes NC370i PCI...
Integrating Microsoft Windows Server 2003 R2 on HP ProLiant servers
Page 6
..., and Token Ring network interface controllers (NICs). Table 9 lists supported ProLiant storage options and recommended driver revisions needed to Table 8 of this publication. Table 10 lists supported NICs and driver revisions supported by Windows Server 2003 R2. Supported hardware ProLiant servers and storage and network options Refer to interface with HP management tools. HP delivers intelligent fault resilience with its...
..., and Token Ring network interface controllers (NICs). Table 9 lists supported ProLiant storage options and recommended driver revisions needed to Table 8 of this publication. Table 10 lists supported NICs and driver revisions supported by Windows Server 2003 R2. Supported hardware ProLiant servers and storage and network options Refer to interface with HP management tools. HP delivers intelligent fault resilience with its...
Integrating Microsoft Windows Server 2003 R2 on HP ProLiant servers
Page 25
....SYS HP NC7170 Gigabit Server Adapter - Supported ProLiant Network Interface Controllers NIC Driver HP NC3162 Fast Ethernet N100325.SYS (Embedded) HP NC3163 Fast Ethernet N100325.SYS (Embedded) HP NC4621 Token Ring CPQTRND5.SYS NIC HP NC6132 Gigabit Module N1000NT5.SYS HP NC6133 Gigabit Module N1000NT5.SYS HP NC6134 Gigabit N1000NT5.SYS HP NC6136 Gigabit N1000NT5.SYS HP NC6170 Gigabit Server Adapter N1000325.SYS HP NC6170 Gigabit Server...
....SYS HP NC7170 Gigabit Server Adapter - Supported ProLiant Network Interface Controllers NIC Driver HP NC3162 Fast Ethernet N100325.SYS (Embedded) HP NC3163 Fast Ethernet N100325.SYS (Embedded) HP NC4621 Token Ring CPQTRND5.SYS NIC HP NC6132 Gigabit Module N1000NT5.SYS HP NC6133 Gigabit Module N1000NT5.SYS HP NC6134 Gigabit N1000NT5.SYS HP NC6136 Gigabit N1000NT5.SYS HP NC6170 Gigabit Server Adapter N1000325.SYS HP NC6170 Gigabit Server...
Integrating Microsoft Windows Server 2003 R2 on HP ProLiant servers
Page 26
... Microsoft Windows Server 2003 Version 7.50A HP NC7781 PCI-X Gigabit Q57XP32.SYS Server LOM ProLiant Support Pack for Yes Microsoft Windows Server 2003 Version 7.50A HP NC7782 PCI-X Gigabit B57AMD64.SYS Server Adapter - Supported ProLiant Network Interface Controllers NIC Driver Location Digital signature (Y/N) HP NC7771 Gigabit Server Adapter Q57XP32.SYS ProLiant Support Pack for Yes Microsoft Windows Server 2003 Version 7.50A HP NC7771 Gigabit Server Adapter...
... Microsoft Windows Server 2003 Version 7.50A HP NC7781 PCI-X Gigabit Q57XP32.SYS Server LOM ProLiant Support Pack for Yes Microsoft Windows Server 2003 Version 7.50A HP NC7782 PCI-X Gigabit B57AMD64.SYS Server Adapter - Supported ProLiant Network Interface Controllers NIC Driver Location Digital signature (Y/N) HP NC7771 Gigabit Server Adapter Q57XP32.SYS ProLiant Support Pack for Yes Microsoft Windows Server 2003 Version 7.50A HP NC7771 Gigabit Server Adapter...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 46
...HPQnetstrategy package is causing the error (c0t0d0 in the miniroot. Add a dontuse keyword to the JumpStart profile to cause the installation to the JumpStart server. 2. Verify that is installed in the miniroot, and that any profile files it either cannot find one of the files, one of rules... one of sysidcfg and verify that your deployment configuration includes or targets the correct miniroot on the Solaris media verifies rules and any necessary NIC drivers have been installed in this case) is incomplete. • 252-The sol.sh script was unable to copy multiboot and/or x86....
...HPQnetstrategy package is causing the error (c0t0d0 in the miniroot. Add a dontuse keyword to the JumpStart profile to cause the installation to the JumpStart server. 2. Verify that is installed in the miniroot, and that any profile files it either cannot find one of the files, one of rules... one of sysidcfg and verify that your deployment configuration includes or targets the correct miniroot on the Solaris media verifies rules and any necessary NIC drivers have been installed in this case) is incomplete. • 252-The sol.sh script was unable to copy multiboot and/or x86....
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 47
... succeeds but server fails to boot If the system is not booting to configure network interfaces after the post-installation reboot, see "Network configuration fails during interactive installation." If the system is booting to GRUB, but reboots shortly after the Solaris copyright banner appears, then verify that all required NIC drivers were installed...
... succeeds but server fails to boot If the system is not booting to configure network interfaces after the post-installation reboot, see "Network configuration fails during interactive installation." If the system is booting to GRUB, but reboots shortly after the Solaris copyright banner appears, then verify that all required NIC drivers were installed...